Glass laboratory water stills: design and performance. B. Performance.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Pot-culture experiments were carried out to estimate the role of non-hydraulic root signals (nHRS) and the relation of these signals to drought tolerance and grain yield formation under drought stress in six wheat varieties. These were two modern hexaploid wheat (Triticum aestivum L., AABBDD) Plateau602 and Longchun8139-2, two diploid wheat (Triticum monococcum L., AB) MO1 and MO4, and two tetraploid wheat (Triticum dicoccum Schuebl L., AABB) DM22 and DM31. In the two diploid relatives, the nHRS was switched on and off at a soil water content (SWC) of approximately 53-45% field water capacity (FWC). In contrast, in the modern hexaploid varieties, Longchun8139-2 and Plateau602 the nHRS occurred between a SWC of about 71 and 35% FWC, a much wider soil moisture range. The two tetraploid relatives, DM22 and DM31, were generally intermediate. The nHRS threshold range in SWC also narrowed as all six varieties went through successive developmental stages from shooting to grain filling. The two hexaploid wheat varieties had the longest duration of survival after the water supply ceased, and the best yield stability under drought stress, similar to with tetraploid wheat varieties; the diploid wheat varieties were least robust. These two parameters were both significantly correlated with the nHRS soil moisture threshold range (r=0.9456** and 0.8608*, respectively). Based on these patterns, we propose a "triple Z" model to describe the features of non-hydraulic stomatal sensitivity versus soil drought in wheat growth.
Explore the source record for details and available documents.
Problems encountered in obtaining reliable analytical data by HPLC for the free nucleotide constituents of plant tissues are considered and methods of overcoming them experimentally assessed. Major problems include suppression of residual phosphatase activity during extraction, and removal of pigments, phenolics, alkaloids, and other uv-absorbing nonnucleotides, prior to HPLC. An optimal combination of extraction and pre-HPLC purification techniques is discussed which, in combination with HPLC by anion exchange, yields quantitatively reliable data. The optimized procedure involves extraction with a monophasic mixture of methanol: chloroform:formic acid:water and purification of the nucleotide extract by a batch treatment with poly-N-vinylpyrrolidone, followed by ligand-exchange chromatography. The main HPLC separation uses mu Bondapak NH2 in a linear phosphate gradient and gives good resolution of all the commonly occurring plant nucleotides in a single chromatographic run.
Immobilized artificial membrane (IAM) HPLC supports have been used to immobilize the enzymes alpha-chymotrypsin and trypsin. The enzymes were trapped in hydrophobic cavities on the support and were not covalently attached to the IAM surface. The resulting IAM-enzyme supports retained the hydrolytic activity of the immobilized enzymes: the IAM-trypsin support catalyzed the hydrolysis of N alpha-benzoyl-DL-arginine-p-nitroanilide (BAPNA), and the IAM-alpha-chymotrypsin support (IAM-ACHT) catalyzed the hydrolysis of a number of substrates, including tryptophan methyl ester. The activities of both supports were decreased by known enzyme inhibitors and the activity of the IAM-ACHT was affected by changes in pH and temperature. When a substrate was chromatographed on an IAM-ACHT HPLC, the hydrolytic activity of the immobilized enzyme could be determined from the resulting substrate/product ratios. These data were obtained either directly from the IAM-ACHT chromatogram or from the chromatogram produced by a coupled column system. The results of this study indicate that IAM-immobilized alpha-chymotrypsin and trypsin can be used as chromatographic probes for the qualitative determination of enzyme/substrate and enzyme/inhibitor interactions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A peak tracking algorithm for peptide analysis has been developed based on a normalised spectral overlay method which directly compares the UV spectra of any two chromatographic peaks. Additionally, the algorithm compares the spectrum of each peak in the first chromatogram with the spectra of every peak in the second chromatogram to determine the best cross-match. The sensitivity of the technique was further enhanced by incorporation of the primary and secondary derivative spectra for cross-match normalisation. The utility of the software was demonstrated by its application to the analysis of tryptic digests of porcine growth hormone. Peptide solutes could be identified and tracked in chromatograms generated with various column types, gradient times, mobile phase types and temperatures. These results therefore constitute the initial stages of development of a more robust approach to the optimisation of the resolution, detection and characterisation of peptides and proteins separated by HPLC techniques.
An automated on-line method is described that involves a first LC separation on a large column, evaporation of a 6-ml fraction in an on-line solvent evaporator, a second LC separation using a different mobile phase, fractionating the components of interest and transfer to GC through the in-line vaporizer/overflow interface. The method is designed for the injection of a large amount of food extract (e.g. up to 200 mg of fat) and is applied to the analysis of mineral oil material in a linseed oil.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Tests of HPLC columns with restricted access, polymer covered alumina, polymer, and different ODS phases showed that base-acid compatible ODS columns gave the best peak shapes of cortisol, internal standard, as well as of plasma/serum (P/S) matrix components. Further trials with cortisol in P/S showed that three separation steps were essential in order to obtain chromatographic data which were superior to immunoassay data. Also, sufficient confidence in results required determination of each sample with two newly developed separation methods: (a) pre-separation with a restricted access column, concentration of the desired cut with a 20 mm base-acid compatible ODS column, and analysis with a 250 mm column filled with the same ODS; (b) pre-separation with an ultrafilter followed by the last two steps in (a). For detection UV was preferred over fluorescence. This twin multistep chromatography showed that immunoassays were very treacherous in that they produced a spectrum of results ranging from good to untenable without any warning whatever about functionality. The measurement of official controls, with reference values derived via gas chromatography-isotope dilution mass spectrometry, also demonstrated the superiority of the double HPLC method.
A phase separator is described that is suitable for post-column HPLC applications. It operates with commonly used HPLC eluents and immiscible organic solvents as long as the two phases remain immiscible. It is compatible with gradient elution systems. Separation efficiency is routinely better than 0.8, which ensures that analyte peak heights are about 95% of the maximum height under these conditions. An application for the detection of pethidine, cocaine, methadone, piritramide and dipipanone at 0.8-1.8 ng on-column loadings is described.
A reversed-phase HPLC method for the analysis of degradation products of the model aspartyl tripeptides Phe-Asp-GlyNH2 and Gly-Asp-PheNH2 after incubation at pH 2 and 10 was developed. Most of the compounds could be separated with a gradient of acetonitrile in water containing 0.1% trifluoroacetic acid. Resolution of the isomeric pairs L-Phe-alpha-L-Asp-GlyNH2/L-Phe-beta-L-Asp-GlyNH2 and L-Phe-alpha-D-Asp-GlyOH/L-Phe-beta-D-Asp-GlyOH was achieved with a gradient of acetonitrile in phosphate buffer, pH 5.0. Under acidic conditions the major degradation pathway was cleavage of the peptide backbone amide bonds yielding dipeptides and amino acids, C-terminal deamidation as well as formation of succidinimyl peptides. At alkaline pH both deamidation of the C-terminal amide as well as isomerization and concomitant enantiomerization of Asp were observed. The peaks were identified both by reference substances and by online electrospray mass spectrometry. The results were compared to a previous developed capillary electrophoresis method. Diastereomeric pairs ofpeptides that could not be separated by capillary electrophoresis were resolved by HPLC while the separation of corresponding pairs of alpha- and beta-Asp peptides was not always achieved by HPLC in contrast to capillary electrophoresis illustrating that both techniques can be complimentary in peptide analysis.
An HPLC method on C18 column using a gradient mobile phase is proposed for the separate determination of residual benzoyl peroxide (BP) and benzoic acid (BA) in flour and wheat products. The recoveries obtained were quite excellent, from 96.0 to 99.3% for BP added to the flour, and 91.3% for BA added to the flour. Analysis of 10 samples of commercial foods such as flour and wheat products, detected 0.7 microg/g of BP in imported noodles. Furthermore, we successfully verified the existence of BP by LC-MS. These methods are simple and reliable for determination and verifying the amount of BP and BA in foods since now the use of BP as a food additive is permitted in many countries.
Nepsilon-Monomethyllysine was identified in the serum, urine, brain, and liver samples of rats treated per os with L-deprenyl. The identification procedure included reaction with Fmoc chloride, clean-up, and analysis using HPLC-UV-MS. Oral administration of (-)-N-14C-methyl-N-propynyl(2-phenyl-1-methyl)ethylammonium hydrochloride L-deprenyl) to rats resulted in transfer of the radiolabelled methyl group to the Nepsilon-amino group of the endogenous lysine. The radiolabelled Nepsilon-monomethyllysine was urinary eliminated together with the other radiolabelled deprenyl metabolites, such as deprenyl-N-oxide and methamphetamine. The presence of Nepsilon-monomethyllysine has also been traced, and its concentrations were compared in the serum, liver and brain of rats subjected to L-deprenyl treatment. Methyl group transfer from the L-deprenyl to endogenous compounds; and the urinary elimination of their products may offer a vital way to eliminate or to decrease the degree of drug transmethylation to the lysine constituents of blood vessels' proteins.
Explore the source record for details and available documents.
Gradient chromatofocusing is a recently developed chromatographic technique that overcomes the limitations of conventional chromatofocusing. This technique employs a HPLC gradient system and simple low-molecular-mass buffer components to generate linear or other function pH gradients on ion-exchange columns. Results of the present work show a superior separation of beta-lactoglobulin A and B in gradient chromatofocusing compared to salt gradient chromatography using the same DEAE column, with an optimized resolution of 2.3 obtained with gradient chromatofocusing compared to 1.1 obtained with NaCl gradients at constant pH. A significant advantage of the gradient chromatofocusing technique over the conventional chromatofocusing technique is its ability to employ a relatively wide range of buffer concentrations in the mobile phase, the effect of which is studied in the present work. Five proteins (conalbumin, ovalbumin, bovine serum albumin, beta-lactoglobulin A and B) are chromatographed on a DEAE-polymethacrylate HPLC anion-exchange column using the same approximately linear pH gradient profile but different mobile phase buffer concentrations. Results show a significant effect of buffer concentration on peak width, separation factor and resolution. For example, resolution increases from 1.5 to 2.3 in the separation of beta-lactoglobulin A and B when the concentration of each of the components in the 100% elution buffer is increased from 6.25 to 25.0 mM (with the same outlet pH gradient). This separation trend is also seen in the chromatography of ovalbumin from a commercial source, noting a progressive increase in resolution of two peaks in the sample (resolution increased from 0.7 to 2.4) when the concentration of each of the components in the 100% elution buffer is increased from 6.25 to 37.5 mM (same outlet pH gradient). The gains in the resolution are attributed to an increase in the separation factor, since the peak widths are generally noted to also increase with increased buffer concentration. These results point to a significant interplay between buffer concentration and pH, which is not effectively exploited in either conventional chromatofocusing or in conventional ion-exchange chromatographic procedures employing salt gradient elution at constant pH. Gradient chromatofocusing has the ability of optimizing both parameters, thus providing it with unique capabilities in protein separations.