PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Digital subtraction angiography (DSA) of the extracranial cerebral vessels: a direct comparison between intravenous and intra-arterial DSA.

Fifty patients being investigated for ischaemic cerebrovascular disease underwent both intravenous digital subtraction angiography (IV-DSA) and intra-arterial arch digital subtraction angiography (arch-DSA) to enable a direct comparison to be made between the two techniques. The overall quality of the images obtained by arch-DSA was better than that obtained by IV-DSA, but there was no significant difference between the number and gradation of stenoses detected by the two techniques. No significant stenosis was missed by IV-DSA and the technique was found to be sufficiently accurate for it to be used as a screening procedure for carotid bifurcation stenoses suitable for carotid endarterectomy. The advantages and limitations of both techniques are discussed.

Adult↗

[Comparison of digital subtraction angiography, CT angiography, and ultrasonic Doppler examination in the evaluation of penile arterial lesions].

BACKGROUND: CT angiography reconstructed by a multidetector-row helical CT scanner is a newly developed form of imaging. We compared CT angiography and ultrasonic Doppler examination with digital subtraction angiography (DSA) in the diagnosis of arterial lesion. METHOD: Eighteen patients with arteriogenic erectile dysfunction (ED) underwent color Doppler study, DSA, and CT angiography after providing informed consent. The CT angiography images were obtained by a multidetector-row helical CT scanner, Asteion TSX021A (TOSHIBA). We injected prostaglandin E1 into the penile cavernous body, and then rapidly infused nonionic contrast medium into the antecubital vein. DSA and CT angiography images of the bilateral internal pudendal arteries and cavernous arteries were examined for stenotic lesions or occlusion. We also compared the peak systolic blood flow velocity in the cavernous artery measured by color Doppler ultrasound with CT angiography and DSA. RESULTS: The CT angiography and color Doppler studies were performed on an outpatient basis, but DSA required hospitalization. In the 36 internal pudendal arteries, DSA represented 22 normal arteries and 14 stenosis or occlusions. CT angiography showed 15 normal arteries and 21 occlusions. For the diagnosis of stenosis or occlusion in the internal pudendal artery, the CT angiography image had a good agreement, with a sensitivity of 1.00, specificity of 0.68, and accuracy of 0.81. For diagnosis in the cavernous artery, CT angiography image also showed a good agreement with DSA; however, the quality of the images of fine arteries was better in the DSA images. The inferior view and internal view of the pelvis in CT angiography were helpful for visualizing the internal pudendal artery, especially at the pubic bone. There was insufficient correlation between peak systolic blood flow velocity and DSA findings. There were no serious complications involved in either examination. CONCLUSIONS: CT angiography has not yet reached the same level as DSA in the evaluation of fine arteries. However, CT angiography can produced images sufficient for the diagnosis of arteriogenic ED with some advantages. We believe that with improvement, CT angiography will become an adequate replacement for DSA in the diagnosis of penile arterisl lesion.

Adult↗

Radiation dose to patients and personnel during intraoperative digital subtraction angiography.

BACKGROUND AND PURPOSE: The use of intraoperative angiography to assess the results of neurovascular surgery is increasing. The purpose of this study was to measure the radiation dose to patients and personnel during intraoperative angiography and to determine the effect of experience. METHODS: Fifty consecutive intraoperative angiographic studies were performed during aneurysmal clipping or arteriovenous malformation resection from June 1993 to December 1993 and another 50 from December 1994 to June 1995. Data collected prospectively included fluoroscopy time, digital angiography time, number of views, and amount of time the radiologist spent in the room. Student's t-test was used to assess statistical significance. Effective doses were calculated from radiation exposure measurements using adult thoracic and head phantoms. RESULTS: The overall median examination required 5.2 minutes of fluoroscopy, 55 minutes of operating room use, 40 seconds of digital angiographic series time, and four views and runs. The mean room time and the number of views and runs increased in the second group of patients. A trend toward reduced fluoroscopy time was noted. Calculated effective doses for median values were as follows: patient, 76.7 millirems (mrems); radiologist, 0.028 mrems; radiology technologist, 0.044 mrems; and anesthesiologist, 0.016 mrems. CONCLUSION: Intraoperative angiography is performed with a reasonable radiation dose to the patient and personnel. The number of angiographic views and the radiologist's time in the room increase with experience.

Adolescent↗

Mechanism of the re-buildup phenomenon in moyamoya disease--analysis of local cerebral hemodynamics with intra-arterial digital subtraction angiography.

The authors investigated the mechanism of the re-buildup phenomenon on electroencephalogram in 14 patients of moyamoya disease with superficial temporal artery-middle cerebral artery anastomosis. Visualization of the lateral view of the common carotid angiography was performed with intra-arterial digital subtraction angiography (IA-DSA), using a 4/sec x 3 sec + 2/sec x 5 sec + 1/sec x 5 sec film sequence. The catheter tip was inserted into C5/6 level and 250 mgI/ml of iopamidol was used as the contrast agent; 6 ml in total was injected over 1.5 seconds. Circulation times of the common carotid artery (C3 portion)-ascending parietal vein (delta TTPs) and common carotid artery-internal cerebral vein (delta TTPD) were measured before hyperventilation (HV), immediately after HV, and 3 minutes after HV during pre- and postoperative periods. delta TTPD in the preoperative period was prolonged by HV and was normalized at 3 minutes after HV but delta TTPs were prolonged immediately after and 3 minutes after HV. In the postoperative period, however, these values did not change significantly immediately after and 3 minutes after HV. These findings indicate that delayed cerebral blood flow response to HV is a pathogenetic factor of the re-buildup phenomenon in moyamoya disease.

Adolescent↗

Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography.

The sensitivities and specificities of three-dimensional time-of-flight MR angiography (3D-TOF MRA) and 3D digital subtraction angiography (3D-DSA) were compared for evaluation of cerebral aneurysms after endosaccular packing with Guglielmi detachable coils (GDCs). Thirty-three patients with 33 aneurysms were included in this prospective study. 3D-TOF MRA and 3D-DSA were performed in the same week on all patients. Maximal intensity projection (MIP) and 3D reconstructed MRA images were compared with 3D-DSA images. The diameters of residual/recurrent aneurysms detected on 3D-DSA were calculated on a workstation. In 3 (9%) of 33 aneurysms, 3D-TOF MRA did not provide reliable information due to significant susceptibility artifacts on MRA. The sensitivity and specificity rates of MRA were 72.7 and 90.9%, respectively, for the diagnosis of residual/recurrent aneurysm. The diameters of residual/recurrent aneurysms that could not be detected by MRA were significantly smaller than those of detected aneurysms (mean 1.1 vs mean 2.3 mm). In one aneurysm of the anterior communicating artery (ACoA), the relationship between the residual aneurysm and the ACoA was more evident on MRA than DSA images. MRA can detect the recurrent/residual lumen of aneurysms treated with GDCs of up to at least 1.8 mm in diameter. 3D-TOF MRA is useful for follow-up of intracranial aneurysms treated with GDCs, and could partly replace DSA.

Adult↗

Patency and flow velocity profiles in the internal carotid artery assessed by digital subtraction angiography and Doppler studies three months following endarterectomy.

Pulsed Doppler spectral analysis and intravenous digital subtraction angiography have been carried out in 55 patients, three months after a total of 60 carotid endarterectomies. Five patients were operated on both sides and there were no re-operations. There were no re-stenoses and only one of the 60 internal carotid arteries was occluded. Spectral spreading of of the Doppler signal at the site of the endarterectomy was found in 52% of the internal carotid arteries, whereas wall irregularities were demonstrated in 25% by intravenous digital subtraction angiography. A stenosis or occlusion was found in 11 (18%) of the 60 ipsilateral external carotid arteries.

Carotid Artery Diseases↗

Multidetector CT angiography of the aortoiliac system and lower extremities: a prospective comparison with digital subtraction angiography.

OBJECTIVE: Our objective was to determine whether multidetector CT (MDCT) angiography is an accurate and reliable method of revealing atheroocclusive disease of the aortoiliac system and the lower extremities compared with digital subtraction angiography (DSA). SUBJECTS AND METHODS: Forty-one patients with ischemic legs underwent both MDCT angiography and DSA of the aortoiliac system and the legs. The arterial supply of the legs was divided into 35 segments. Three independent observers rated each segment according to the maximal degree of arterial stenosis. Consensus interpretation was used to calculate the sensitivity and specificity of MDCT angiography in showing arterial occlusions and stenoses of at least 75%. Intertechnique agreement was measured for each anatomic segment, and interobserver agreement was calculated for both techniques. Agreement was quantified using the kappa statistic. RESULTS: The sensitivity and specificity of MDCT angiography for depicting arterial occlusions and stenoses of at least 75% were 88.6% and 97.7%, and 92.2% and 96.8%, respectively. Substantial intertechnique agreement (kappa > 0.4) was present in 102 (97.1%) of 105 arterial segments. Substantial interobserver agreement was present in 104 (99.0%) of 105 comparisons for both MDCT angiography and DSA with an average kappa value of 0.84 for CT and 0.78 for DSA. MDCT angiography showed more patent segments than DSA (1192 vs 1091). All nine segments seen on DSA and not seen on MDCT angiography were in the calves. Of 110 segments seen on MDCT angiography and not seen on DSA, 100 (90.9%) were in the calves. CONCLUSION: MDCT angiography was accurate in showing arterial atheroocclusive disease with reliability similar to DSA. MDCT angiography showed more vascular segments than DSA, particularly within calf vessels.

Adult↗

Absolute volumetric blood flow measurements using dual-energy digital subtraction angiography.

In recent years, as a solution to the well-documented problems associated with visual interpretation of coronary arteriograms, more physiologic means of assessing coronary artery stenosis are being investigated. Absolute arterial blood flow assessed as a function of time can be a valuable aid in the analysis of functional significance of arterial lesions and obstructions. An absolute volumetric blood flow measurement technique using a motion immune dual-energy subtraction technique is being investigated, where the kVp and filtration are switched at 30 Hz. The low- and high-energy images are corrected for scatter and veiling glare before subtraction. In this technique, the absolute arterial blood flow is calculated by combining the videodensitometric analysis of spatial and temporal aspects concerning the contrast propagation through the arterial bed using tissue suppressed energy subtracted images. The blood flow measurement technique was validated using a pulsatile pump and a flow chamber imaged over a Humanoid chest phantom. A 20-MHz Doppler flow probe was used to validate the measurement of phasic volumetric blood flow. The measured (M) and known (K) mean blood flow for the entrance vessel technique and the videodensitometric calibration technique were related by M = 1.14K - 0.12 ml/s (r2 = 0.98) and M = 1.12K - 0.23 ml/s (r2 = 0.90), respectively. The results indicate that phasic volumetric blood flow can be measured using a CCD camera in conjunction with real time dual-energy subtraction.

Angiography, Digital Subtraction↗

Dynamic k-space filling for bolus chase 3D MR digital subtraction angiography.

A bolus chase three-dimensional (3D) MR digital subtraction angiography (MRDSA) technique was implemented using dynamic k-space filling. This technique permits rapid 3D arterial imaging of the entire lower extremity at multiple stations using a single intravenous injection. Image acquisition at the first (most proximal) station starts from the edge of k-space and ends in the center of k-space (edge-center order). Image acquisition for middle stations starts from the edge of k-space, arrives at the center of k-space at the middle of data acquisition, and ends at the edge of k-space (edge-center-edge order). Image acquisition for the last station starts from the center of k-space and ends at the edge of k-space (center-edge order). This dynamic k-space filling minimizes contrast dose and motion artifacts. Bolus chase 3D MRDSA was performed on four normal volunteers and three patients using a multiple-phase 3D fast gradient-echo sequence, 25-ml gadolinium dose, and a prototype stepping table. Total bolus chase 3D acquisition time was 46 s. Mask subtraction using both complex and magnitude subtraction was performed. Complex subtraction was found to be necessary for proper delineation of arteries below the aortic bifurcation. Diagnostic results were consistently obtained for all subjects.

Adult↗

[Digital subtraction angiography in traumatology].

The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure.

Angiography↗

[Intravenous digital subtraction angiography for imaging pulmonary vessels].

The experience in venous digital subtraction angiography (DSA) of the pulmonary vessels is presented in order to evaluate the new method. The results of angiographic examinations in 30 patients could be classified as follows: embolic lung disease (n = 13), atelectatic disease of left lower lobe (n = 3), findings of arteritis in right upper lobe (n = 1), arteriographic alterations due to chronic pulmonary emphysema (n = 2), normal lung vessels (n = 10), and failure of examination (n = 1). Using this new angiographic method it was possible to analyze embolic clots in the subsegmental arteries and total occlusions of the peripheral small vessels. The advantage of DSA compared with the conventional technique is evident: No complications due to transcardial catheters, short examination period, easy handling of the technique, and small number of images.

Adult↗

Nonselective digital subtraction angiography. Compact contrast material bolus for improved image quality.

Digital subtraction angiography (DSA) examinations of major aortic branch vessels traditionally have been performed with aortic injections of dilute contrast material (70-150 mg I/mL) over approximately 2 seconds. This study examines a technique employing rapid boluses of undiluted contrast material (282-300 mg I/mL) in small volumes and compares the quality of the images to those obtained using conventional methods. Twenty intra-aortic DSA angiograms of the renal arteries were performed in 10 patients. In each patient, both compact bolus and conventional injections were performed. Injections of 12 or 15 mL of diatrizoate meglumine-60% at 30 mL/second (duration = 0.4 or 0.5 seconds) were compared with injections of 24 or 30 mL of diatrizoate meglumine-30% at 12 mL/second (duration = 2 seconds). Aside from injection technique and image projection, no other variables were altered, and the iodine loads were the same for the two injections in each patient. The images were paired and rated by four radiologists without knowledge of the technical parameters. The radiologists overwhelmingly preferred the images corresponding to the compact bolus technique (Chi-square analysis P less than .001). Visualization of the main renal arteries and the intrarenal branches was improved (P less than .001 for both). A reduction in misregistration artifact is suggested but not statistically significant. We conclude that image quality in nonselective, intra-arterial DSA can be improved without an increase in iodine dosage by the rapid administration of undiluted contrast material in small volumes.

Adult↗

Digital subtraction angiography of the kidney.

Intravenous and intra-arterial digital subtraction angiography (DSA) was performed in 88 patients: 34 with tumours, 10 with renal trauma, 26 with suspected renovascular hypertension, 6 with vascular impression on the renal pelvis, 8 with nephrolithiasis and 4 with sonographically abnormal kidneys. Venous and arterial DSA always gave diagnostically useful images. Intravenous DSA is valuable in patients with suspected renovascular hypertension or after vascular surgery, percutaneous transluminal angioplasty and transcatheter embolisation. Arterial DSA is preferable to venous DSA in other clinical situations, particularly in the evaluation of renal tumours, and may be recommended in preference to conventional angiography.

Adult↗

Intra-arterial digital subtraction angiography of the head and neck.

Intra-arterial digital subtraction angiography (IA DSA) was compared with conventional film/screen angiography in 70 patients with suspected atherosclerotic disease or intracranial disease. It was found that, although the contrast detectability of IA DSA was superior to that of conventional angiography, its spatial resolution was not as great. In all 70 cases, however, the spatial resolution of IA DSA was satisfactory for diagnosis, and it is concluded that the increased spatial resolution of conventional angiography should be necessary only in rare circumstances. The main disadvantage of IA DSA is the smaller field size, and it has several advantages over conventional film/screen angiography: (a) it is safer, since less contrast material is needed to visualize large vessels; (b) costs are lower since the magnetic recording tape and hard copies result in a savings of between $45 and $140 per examination; and (c) there is less need for darkroom personnel and film storage.

Aorta, Thoracic↗

A high frame-rate digital subtraction angiography imaging technique for evaluation of aortofemoral runoff.

Intravenous digital subtraction angiography was used to obtain a complete aortofemoral runoff examination of high diagnostic quality in a single patient session in eight patients. Using a 9-inch (22.9-cm) image intensifier, oblique and posteroanterior projections were obtained from the level of the aortic bifurcation to the tibial artery trifurcation. This technique is based upon the administration of one-half of the usual dose of contrast agent combined with a high frame-rate imaging technique and postacquisition integration to increase the signal-to-noise ratio. It is easily performed on an outpatient basis, lowers patient risk, and allows a significant savings of time, film, and cost compared with the conventional intra-arterial aortofemoral runoff examination.

Aortography↗

Tomosynthesis applied to digital subtraction angiography.

This extension of our previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, we describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed.

Angiography↗