PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biodegradable Delivery Systems”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

[Dendritic systems for drug delivery applications].

Dendrimers are synthetic, highly branched and nanometer-sized macromolecules that offer potential application to various fields. They have uniform size and molecular weight, wide internal cavity and modifiable surface functionality that made them very attractive for biological and drug delivery applications. Commercially available PAMAM (polyamidoamine) dendrimers are most frequently used for construction of delivery system by modification of surface amino groups. One of the examples is anticancer drug-PAMAM conjugate with folic acid (FA) for targeting. DNA linked FA-PAMAM and FITC-PAMAM conjugates have been recently developed. Polyester dendrimers are expected to be biodegradable and less toxic to cells. An example is shown. Lastly, construction of a delivery system using caged compounds for photochemical release of drug is described.

Biocompatible Materials↗

Innovations in avoiding particle clearance from blood by Kupffer cells: cause for reflection.

Therapeutic applications of drug carrier systems following intravenous administration have been limited because of the pronounced tendency of these carriers to localize primarily in Kupffer cells. Recently, attempts have been made to design colloids and drug carrier systems that can be disguised as "self" and remain unrecognizable, at least to a certain extent, by the hepatic macrophages. This review is designed to provide a critical view on fundamentals, current progress, limitations, and future prospects of such engineered colloids and drug carrier systems for intravenous route of administration.

Binding Sites↗

Release of bioactive human growth hormone from a biodegradable material: poly(epsilon-caprolactone).

We have characterized the biodegradable material poly(epsilon-caprolactone) (PCL) as a delivery system for recombinant human growth hormone (hGH). Two contrasting methods for the manufacture of the biomaterial were investigated: namely, solvent casting and solvent casting particulate leaching; the latter yielded porous PCL discs. The degree of porosity, which was assessed by scanning electron microscopy, could be controlled by incorporating selected concentrations of particulate sodium chloride during the manufacturing process. Bioactive hGH released from the PCL preparations was quantified with a highly sensitive and precise bioassay which was based upon hGH activation of rat lymphoma Nb2 cells. Eluates obtained from control discs of PCL which had not been loaded with hGH proved to be nontoxic when tested on these cells. The release of bioactive hGH from hormone-loaded nonporous discs of PCL was found to be a direct function of the initial hormone loading dose. Increased porosity of the discs manufactured by solvent casting particulate leaching increased the delivery of hGH from discs which had been immersion loaded. However, hGH release after surface loading was independent of porosity. Hormone concentrations were also assessed by immunoassay so that the ratios of bio- to immunoactivity (B:I ratio) of the hormone release could be determined. We found that the B:I ratio of the hormone after release from unstored discs was identical to that of the hormone prior to its incorporation into the PCL, demonstrating that the mild incorporation procedures utilized had not adversely affected the structural integrity of the hormone. However, if the hormone-loaded discs were stored at 37 degrees C prior to elution, the B:I ratios of the hGH released decreased indicating that this compromised the bioactive site.

Animals↗

Artificial cells in medicine and biotechnology.

Since the feasibility of artificial cells was first demonstrated in 1957 [Chang (1, 2)], an increasing number of approaches to their preparation and use have become available. Thus artificial cell membranes can now be formed using a variety of synthetic or biological materials to produce desired variations in their permeability, surface properties, and blood compatibility. Almost any material can be included within artificial cells. These include enzyme systems, cell extracts, biological cells, magnetic materials, isotopes, antigens, antibodies, vaccines, hormones, adsorbents, and others. Since cells are the fundamental units of living organisms, it is not surprising that artificial cells can have a number of possible applications. This is especially so since artificial cells can be "tailor-made" to have very specialized functions. A number of potential applications suggested earlier have now reached a developmental stage appropriate for clinical trial or application. These clinical applications include the use of such cells as a red blood cell substitute, in hemoperfusion, in an artificial kidney or artificial liver, as detoxifiers, in an artificial pancreas, and so on. Artificial red blood cells based on lipid-coated fluorocarbon or crosslinked hemoglobin are being investigated in a number of centers. The principle of the artificial cells is also being used in biotechnology to immobilize enzymes and cells. Developments in biotechnology have also resulted in the use of the principle underlying the artificial cell to help produce interferons and monoclonal antibodies; to create immunosorbents; to develop an artificial pancreas; and to bring enzyme technology usefully into biotechnology and biomedical applications. Artificial cells are also being used as drug delivery systems based on slow release, on magnetic target delivery, on biodegradability, on liposomes, or other approaches. The present status and recent advances will be emphasized in this paper.

Animals↗

Influence of formulation on the physicochemical properties of casein microparticles.

Casein microparticles (CAS/MP) have a potential clinical use for targeting drugs. However, the use of organic solvents in their preparation is undesirable. This study was designed to investigate the influence of preparation procedures in aqueous media on the formulation and physicochemical properties of CAS/MP. The first stage involved the influence of the coacervating agents (lactic acid, succinic anhydride, succinic acid and tartaric acid). The second stage studied was the influence of the ionic strength and the third, the influence of adding a thickener, hydroxypropyl cellulose or hydroxypropyl methycellulose (HPC or HPMC), and a plasticizing agent (gelatin). Some physicochemical properties of CAS/MP were evaluated. While the infrared and the thermal analysis showed that all coacervating agents were appropriate for coacervation, the scanning electron microscopy studies showed that the external morphology of the particles was more homogeneous when lactic acid was used. Utilizing lactic acid as the coacervating agent, there was a trend effect of adding NaCl implying that the increasing of the ionic strength resulted in better stability. Finally, the addition of 0.1% HPC plus either 0.25 or 0.5% gelatin resulted in homogeneous formulations. In conclusion, the use of lactic acid plus 0.1% HPC and 0.25% gelatin results in biodegradable and homogeneous CAS/MP, presenting a potentially useful drug delivery system.

Animals↗

Core-cross-linked polymeric micelles as paclitaxel carriers.

Cross-linkable di- and triblock copolymers of poly(epsilon-caprolactone) (PCL) and monomethoxyl poly(ethylene glycol) (MPEG) were synthesized. These amphiphilic copolymers self-assembled into nanoscale micelles capable of encapsulating hydrophobic paclitaxel in their hydrophobic cores in aqueous solutions. To further enhance their thermodynamic stability, the micelles were cross-linked by radical polymerization of the double bonds introduced into the PCL blocks. Reaction conditions were found to significantly affect both the cross-linking efficiency and the micelle size. The encapsulation of paclitaxel into the micelles was confirmed by the proton nuclear magnetic resonance (1H NMR) spectroscopy. Encouragingly, paclitaxel-loading efficiency of micelles was enhanced significantly upon micelle core-cross-linking. Both the micelle size and the drug loading efficiency increased markedly with increasing the PCL block lengths, no matter if the micelles were core-cross-linked or not. However, paclitaxel-loading did not obviously affect the micelle size or size distribution. The cross-linked micelles exhibited a significantly enhanced thermodynamic stability against dilution with aqueous solvents. The efficient cellular uptake of paclitaxel loaded in the nanomicelles was demonstrated by confocal laser scanning microscopy (CLSM) imaging. This new biodegradable nanoscale carrier system merits further investigations for parenteral drug delivery.

3T3 Cells↗

Prolonged regional nerve blockade by controlled release of local anesthetic from a biodegradable polymer matrix.

BACKGROUND: Prolonged nerve blockade is potentially useful in the management of many acute and chronic pain problems. Aside from infusions via an indwelling catheter, most currently available nondestructive techniques for prolonging local anesthetic action cannot provide more than 1-2 days of blockade. Bioerodible polymer matrixes have been used to deliver a variety of drugs in patients and animals for periods lasting weeks to years. Previously, dibucaine and bupivacaine were incorporated into copolymers of 1,3 bis(p-carboxyphenoxy) propane-sebacic acid anhydride (1:4), and demonstrated sustained release in vitro following incubation of the drug-polymer matrixes in phosphate-buffered solution (pH 7.4, 37 degrees C). METHODS: In the present study, cylindrical pellets made from polymer matrixes incorporated with bupivacaine-HCl were implanted surgically along the sciatic nerves of rats. Neural block was assessed by direct observation of motor skills and by leg-withdrawal latency to a hot surface. Biochemical and histologic examinations were performed 2 weeks after implantation. RESULTS: Sensory and motor blockade was produced for periods ranging from 2 to 6 days. Contralateral control legs receiving polymer implants without drug showed no block. Blockade was reversible, and animals appeared to recover sensory and motor function normally. Biochemical indexes of nerve and muscle function were indistinguishable from contralateral controls. CONCLUSIONS: This biodegradable polymer system provides a promising new alternative for the delivery of local anesthetics to peripheral nerves to produce prolonged blockade for the management of acute and chronic pain.

Anesthetics, Local↗

Two clinical trials of an intraocular steroid delivery system for cataract surgery.

PURPOSE: To determine the safety and efficacy of an intraocular dexamethasone drug delivery system (Surodex) in the treatment of inflammation following cataract surgery. METHODS: Surodex is a biodegradable polymer that releases dexamethasone for 7 to 10 days after placement in the anterior segment. Study 1 was a prospective, randomized, double-masked Phase II clinical trial of 90 cataract surgical patients that compared treatment with Surodex to treatment with a placebo drug delivery system and to no anti-inflammatory drug treatment at all. Study 2 was a separate prospective, randomized, double-masked study of 60 cataract surgical patients that compared treatment with Surodex to topical dexamethasone (eye drop) therapy. RESULTS: In the first study, Surodex was superior to placebo in suppressing postsurgical inflammation throughout the 60-day postoperative period, as judged by masked-evaluator, slit-lamp grading of cell and flare. The differences were statistically significant from postoperative day 3 through postoperative week 3. The majority of Surodex patients did not require topical steroid by 2 weeks after surgery (93%) or by 2 months after surgery (88%). In the second study, Kowa laser flare meter readings were lower in Surodex patients throughout the 90-day postoperative period. The results were statistically significant at 4, 8, and 15 days following surgery. There were no significant adverse complications of Surodex in either study. CONCLUSION: Surodex was safe and effective in suppressing postcataract surgery inflammation and appears to be a promising alternative to topical steroids.

Aged↗

Biodegradable chitosan matrix for the controlled release of steroids.

Chitosan, a polysaccharide, having structural characteristics similar to glycosaminoglycans, seems to be nontoxic and bioabsorbable. This study highlights the use of chitosan matrix for controlled drug delivery systems. The steroid drugs, namely testosterone, progesterone and beta-oestradiol were mixed with chitosan and the films were prepared by evaporation technique. The in vitro release profile of these steroids from the film matrix was monitored, as a function of time, in phosphate buffered saline (PBS, pH 7.4) at 37 degree C using a U-V-spectrophotometer. The degradation, of these chitosan and drug loaded chitosan films, was also investigated by weight loss and tensile strength studies. The steroid release from chitosan films was compared with the release of these drugs from their microbeads. It appears, the films and the microbeads stayed intact during the dissolution study of 90 days and the possibility of using these systems in contraceptive applications and novel drug delivery systems are discussed.

Biocompatible Materials↗

Nebulization of biodegradable nanoparticles: impact of nebulizer technology and nanoparticle characteristics on aerosol features.

Nanoparticles may be effective drug delivery systems for use in various pulmonary therapeutic schemes. This study investigated the effect of nebulization technology and nanoparticle characteristics on the features of aerosol generation. Suspensions of biodegradable nanoparticles consisting of commercially available poly(lactide-co-glycolide) and novel comb polymers were nebulized with a jet, ultrasonic, and piezo-electric crystal nebulizer. The effects of the nanoparticle suspensions on the aerosol droplet size, as well as the nanoparticle size before and after nebulization, were characterized via laser diffraction. While the individual nanoparticle suspensions showed no clinically relevant influence on aerosol droplet size, as compared to control experiments, an enhanced nanoparticle aggregation within the droplets was observed. This aggregation was further characterized by fluorescence and scanning electron microscopy. Dependency of aggregation on nebulizer technology and nanoparticle characteristics was noted. Nanoparticles exhibiting the highest surface hydrophobicity were particularly susceptible to aggregation when nebulized with a jet nebulizer. Aggregation was reduced with nanoparticles exhibiting a more hydrophilic surface or when using ultrasonic nebulizers. We conclude that the biodegradable nanoparticles contained in the suspensions did not affect the aerosol droplet size in a clinically relevant manner; however, both the nanoparticle characteristics and the technique of aerosol generation influence nanoparticle aggregation occurring during aerosolization.

Aerosols↗

Local intraluminal infusion of biodegradable polymeric nanoparticles. A novel approach for prolonged drug delivery after balloon angioplasty.

BACKGROUND: Several perfusion balloon catheters are under investigation for local drug delivery; however, sustained tissue drug levels are difficult to achieve with these techniques. To overcome this problem, sustained-release, biodegradable nanoparticles represent a potential alternative for prolonged local delivery. METHODS AND RESULTS: A biodegradable polylactic-polyglycolic acid (PLGA) copolymer was used to formulate nanoparticles. Fluorescent-labeled nanoparticles were intraluminally administered in a single, 180-second infusion after balloon injury in the rat carotid model. Localization and retention at different time points and biocompatibility of nanoparticles were evaluated. To evaluate the potential of the system in the prevention of neointimal formation, dexamethasone was incorporated into the particles and delivered locally as above. Nanoparticles were seen in the three layers of the artery at 3 hours and 24 hours. At 3 days, they were mainly present in the adventitial layer, decreasing at 7 days, with no fluorescent activity at 14 days. The PLGA nanoparticles appeared to be fully biocompatible. In the dexamethasone nanoparticle study, a significant amount of dexamethasone was present in the treated segment for up to 14 days after a single infusion, with no plasma levels detected after the first 3 hours. There was a 31% reduction in intima-media ratio in animals treated with local dexamethasone nanoparticles compared with control. CONCLUSIONS: Nanoparticles successfully penetrated into the vessel wall and persisted for up to 14 days after a short, single intraluminal infusion. Local administration of nanoparticles with incorporated dexamethasone significantly decreased neointimal formation. This methodology appears to have important potential for clinical applications in local drug delivery.

Angioplasty, Balloon, Coronary↗

Development of enteric-coated pectin-based matrix tablets for colonic delivery of theophylline.

The present work was aimed at developing a new colonic drug delivery system which takes advantage of the combined approaches of a specifically colon-biodegradable pectin matrix with a pH-sensitive Eudragit S100 polymeric coating. The developed system was able to suitably retard the onset of drug release and to provide a colon-specific delivery, thus overcoming the problems of pectin solubility in the upper gastrointestinal tract and low site-specificity of simple pH-dependent systems. Due to the poor compactability properties of pectin, it was used in mixture with Emdex, a hydrophilic directly-compressible material, in order to make it possible to prepare tablets by direct compression. Theophylline (TP) was used as model drug due to its suitable pharmacokinetic properties for colonic delivery and good absorption in the large intestine. The effects of varying the type of pectin (low and high methoxylated, or amidated), the pectin:Emdex ratio and the level of the pH-dependent polymeric coating on drug release behavior were investigated. Release tests were performed using sequential liquids simulating the physiological variation of pH and the effect of the presence or not of pectinolytic enzymes into the simulated colonic medium was evaluated. Thirty percent (w/w) was the the minimum content of Emdex for obtaining directly compressible tablets with sufficient hardness to withstand the coating process and 27% (w/w) was the minimum coating amount for obtaining an adequate lag time before the onset of drug release. After lag time, linear nearly zero-order profiles were obtained whose slope (i.e. the drug release rate) depended on both the Emdex content and the pectin type. Comparison of the results obtained in the presence or not of pectynolitic enzymes allowed selection of the high methoxylated pectin as the most interesting candidate for specific colonic delivery since it was the least water-soluble and the most susceptible to enzymatic degradation, thus assuring a greater site-specificity of drug release. Finally, the importance of using appropriate dissolution test conditions to adequately characterize the drug release profiles from delivery systems endowed with a microflora-activated drug release triggering mechanism has been demonstrated.

Bronchodilator Agents↗

Polymers, drug release, and drug-eluting stents.

Implantable biomaterials mainly serve as physical support devices, carriers for bioactive molecules and guidance for tissue growth. For any application within or outside the cardiovascular area, biomaterials are subject to an extended set of requirements in order to establish safe application. These requirements mainly include acceptable biocompatibility and, if the material is to be degraded within the body, safe degradation characteristics. During degradation, biocompatible polymers are broken down into molecules that are metabolized and removed from the body via normal metabolic pathways. Major applications of these polymers include targeted drug delivery systems, resorbable sutures and orthopedic fixation devices. In the cardiovascular area they include biodegradable cardiovascular stents and drug-eluting stent (DES) coatings. This review focuses on general aspects of local drug delivery by implantable polymeric devices, with special emphasis on drug-eluting stents.

Absorbable Implants↗

Drug delivery to tumors of the central nervous system.

Contemporary treatment of malignant brain tumors has been hampered by problems with drug delivery to the tumor bed. Inherent boundaries of the central nervous system, such as the blood-brain barrier or the blood-cerebrospinal fluid barrier, and a general lack of response to many chemotherapeutic agents have led to alternative treatment modalities. In general, all these modalities have sought to either disrupt or bypass the physiologic brain barriers and deliver the drug directly to the tumor. This article reviews past, as well as current, methods of drug delivery to tumors of the central nervous system. Special emphasis is placed on biodegradable polymers that can release chemotherapeutic agents against malignant gliomas. A variety of other nonchemotherapeutic drugs, including antiangiogenesis and immunotherapeutic agents, are presented in the context of new polymer technology. Finally, future directions in drug delivery are discussed with an overview on new advances in emerging biotechnology.

Antineoplastic Agents↗

Controlled release of bioactive TGF-beta 1 from microspheres embedded within biodegradable hydrogels.

Transforming growth factor-beta1 (TGF-beta1) is of great relevance to cartilage development and regeneration. A delivery system for controlled release of growth factors such as TGF-beta1 may be therapeutic for cartilage repair. We have encapsulated TGF-beta1 into poly(DL-lactide-co-glycolide) (PLGA) microspheres, and subsequently incorporated the microspheres into biodegradable hydrogels. The hydrogels are poly(ethylene glycol) based, and the degradation rate of the hydrogels is controlled by the non-toxic cross-linking reagent, genipin. Release kinetics of TGF-beta1 were assessed using ELISA and the bioactivity of the released TGF-beta1 was evaluated using a mink lung cell growth inhibition assay. The controlled release of TGF-beta1 encapsulated within microspheres embedded in scaffolds is better controlled when compared to delivery from microspheres alone. ELISA results indicated that TGF-beta1 was released over 21 days from the delivery system, and the burst release was decreased when the microspheres were embedded in the hydrogels. The concentration of TGF-beta1 released from the gels can be controlled by both the mass of microspheres embedded in the gel, and by the concentration of genipin. Additionally, the scaffold permits containment and conformation of the spheres to the defect shape. Based on these in vitro observations, we predict that we can develop a microsphere-loaded hydrogel for controlled release of TGF-beta1 to a cartilage wound site.

Absorbable Implants↗

Preparation of insulin nanoparticles and their encapsulation with biodegradable polyelectrolytes via the layer-by-layer adsorption.

To develop a new polypeptide delivery system, insulin nano-aggregates with sizes of 100-230nm were prepared by the salting out method with NaCl and encapsulated via the layer-by-layer (LbL) adsorption to provide the insulin nanoparticles shelled with two oppositely charged polyelectrolytes. Poly(alpha,beta-l-malic acid) (PMA) and water-soluble chitosan (WSC) as the weak polyelectrolytes with good biodegradability and biocompatibility in vivo were chosen to be the encapsulating materials of the LbL adsorption. In the preparation of the insulin nano-aggregates, the NaCl concentration and pH in the medium obviously affected yield and particle size of the insulin nano-aggregates. After eight adsorption cycles of the polyelectrolytes on the insulin nano-aggregates, the insulin-polyelectrolyte nanoparticles with the sizes of 100-250nm were obtained with about 20% insulin loss. The insulin release from the nanoparticles was mostly pH-dependent owing to sensitivity of the weak polyelectrolytes to pH. Insulin was hardly released from the nanoparticles in a medium at pH 4-5 while it could be released at pH 7.4, corresponding to the pH of the human blood and the body fluid. A burst effect was also observed although it could be reduced via increasing the polyelectrolyte layers of PMA and WSC assembled on insulin nano-aggregates.

Adsorption↗

[Studies on a kind of new biodegradable material--polycaprolactone and developments in medical area].

Nowadays, there are more and more researches on characters and applications of polycaprolactone (PCL). This paper reviews the researches of polycaprolactone, including its synthesis, physical and chemical properties, biodegradation, absorption properties, and its applications in clinical use and drug delivery systems. PCL can be from open ring polymerizaion. It is a kind of semi-crystalline polymer, and has good flexibility. The degradation reaction of PCL is hydrolysis. PCL is not cumulated in the body, and can be totally excreted. It can be used as suture, material for fixation of bone fracture, vector of drug, etc. PCL is widely used in medical area because of its safety, low toxicity, biodegradability.

Biodegradation, Environmental↗

Characterization of soluble, salt-loaded, degradable PLGA films and their release of tetracycline.

A local drug delivery system has been designed to release tetracycline over a period of 30 days from poly (lactide-co-glycolide) films. Incorporation of either soluble salt excipients or low molecular weight polymeric species has been found to modulate the release kinetics of the system. The following research describes the fabrication of the delivery system, monitors tetracycline release from the system, and fully characterizes the degradation of the polymer films via scanning electron microscopy, gel permeation chromatography, differential scanning calorimetry, Fourier-transform infrared spectroscopy, and X-ray diffraction techniques. Results show that the modulation via use of salts occurs without changing the inherent degradation rate of the system. We suggest that this phenomenon may be due to the increased amount of swelling and uptake of buffer by the films loaded with soluble salt. Uptake, therefore, may be creating microscopic pores that permit further diffusion of tetracycline from the polymer matrix as well as allow the free monomers to leave the system, thereby preventing autocatalysis within the system.

Biodegradation, Environmental↗