PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Computer Programs And Programming”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

A method of mapping protein sumoylation sites by mass spectrometry using a modified small ubiquitin-like modifier 1 (SUMO-1) and a computational program.

Post-translational modification by small ubiquitin-like modifier 1 (SUMO-1) is a highly conserved process from yeast to humans and plays important regulatory roles in many cellular processes. Sumoylation occurs at certain internal lysine residues of target proteins via an isopeptide bond linkage. Unlike ubiquitin whose carboxyl-terminal sequence is RGG, the tripeptide at the carboxyl terminus of SUMO is TGG. The presence of the arginine residue at the carboxyl terminus of ubiquitin allows tryptic digestion of ubiquitin conjugates to yield a signature peptide containing a diglycine remnant attached to the target lysine residue and rapid identification of the ubiquitination site by mass spectrometry. The absence of lysine or arginine residues in the carboxyl terminus of mammalian SUMO makes it difficult to apply this approach to mapping sumoylation sites. We performed Arg scanning mutagenesis by systematically substituting amino acid residues surrounding the diglycine motif and found that a SUMO variant terminated with RGG can be conjugated efficiently to its target protein under normal sumoylation conditions. We developed a Programmed Data Acquisition (PDA) mass spectrometric approach to map target sumoylation sites using this SUMO variant. A web-based computational program designed for efficient identification of the modified peptides is described.

Amino Acid Sequence↗

Description of a computer program to assess cancer antigen 15.3, carcinoembryonic antigen, and tissue polypeptide antigen information during monitoring of metastatic breast cancer.

It is time-consuming to process and compare the clinical and marker information registered during monitoring of breast cancer patients. To facilitate the assessment, we developed a computer program for interpreting consecutive measurements. The intraindividual biological variation, the analytical precision profile, the cutoff limit, and the detection limit for each marker are entered and stored in the program. The assessment procedure for marker signals considers the analytical and biological variation of the applied markers. The software package contains a database that can store the interpretation of the measurements as evaluation codes together with patient demographics, information about treatment type, dates for treatment periods, control periods, and evaluation codes for clinical activity of disease. The consecutive concentrations for a patient are imported temporarily into the program from outside sources and presented graphically. Marker concentrations to be compared are selected with the computer mouse and the significance of the difference is calculated by the program. The program has an option for calculating the lead time of marker signals vs clinical information. The program facilitates the monitoring of individual breast cancer patients with tumor marker measurements. It may also be implemented in trials investigating the utility of potential new markers in breast cancer as well as in other malignancies.

Antibiotics, Antineoplastic↗

Incidence density matching with a simple SAS computer program.

Incidence density matching is the method of choice for selecting controls in nested case-control studies, but its use has been limited by its computational complexity. We describe incidence density matching in nested case-control studies with a simple and flexible SAS computer program. The program contains no restrictions on the number of matching factors, although it is usually only necessary to match on age (in incidence density fashion) and on gender. The program is illustrated with data from an historical cohort study of the mortality experience of workers at an asbestos textile manufacturing plant.

Case-Control Studies↗

AAQUANT: a computer program for quantitative amino acid analysis of proteins and peptides.

Quantitative amino acid analysis is an important tool used in the characterization and structural determination of peptides and proteins. A new computer program, AAQUANT, has been developed specifically to aid researchers in analyzing amino acid composition data. AAQUANT calculates amino acid recoveries, including 95% confidence intervals, following acid hydrolysis of peptides and proteins, and also includes useful routines to locate regions of a specified amino acid composition in known protein sequences, compute amino acid composition reports of known protein sequences, generate proteolytic digestion maps of proteins, and create and edit protein sequence data files. This report describes the AAQUANT routines, and demonstrates the use of the program.

Amino Acid Sequence↗

Design and analysis of accelerated degradation tests for the stability of biological standards II. A flexible computer program for data analysis.

The accelerated degradation test is commonly used to predict the stability of a biological standard during long-term storage at low temperature. A flexible computer program is described which has been written to analyse degradation test results by the method of maximum likelihood. In addition to predicting the degradation rate at low temperature, the program furnishes estimates of statistical precision and it carried out a test of goodness of fit of the data to the assumed Arrhenius equation model.

Biological Products↗

Quantitative forensic evaluation of bite marks with the aid of a shape analysis computer program: Part 2; "SCIP" and bite marks in skin and foodstuffs.

In a previous paper 1, we have shown that the use of an interactive shape analysis computer program ("SCIP") and the derivation of a quantitative Similarity Index 1 greatly facilitated the comparison of experimental flat wax bite marks with the dentition of various 'suspects' and the identification of the agent producing the bite. In this study, "SCIP" was employed in an attempt to quantify the comparison, in the form of the Similarity Index (S.I.), between the "offender's" teeth and the bite marks produced on foodstuffs and on human skin, under experimental conditions. The use of "SCIP" and the S.I. is recommended as a routine means of eliminating suspects in bite mark cases. If a reasonable number of reference points have been registered in the bitten material and particularly if the perpetrator has any unusual features in the anterior dentition, the matching of the bite mark with the actual offender is a possibility with this method.

Bites, Human↗

Computer program for evaluation, physicochemical characterization and optimization of competitive protein binding assays: comparison of four curve-fitting models in peptide and steroid radioimmunoassays.

A modular construced computer program for evaluation, physicochemical characterization and optimization of compititive protein binding assays is put forward. The program allows standard curve fitting by the following models: spline approximation, semi-logarithmic interpolation, logit-log regression and logit-log interpolation. The suitability of these models was studied in a series of routine steroid radioimmunoassays (deoxycorticosterone, deoxycortisol, cortisol and aldosterone) and peptide radioimmunoassays (angiotensin I and angiotensin II). The spline approximation model was used as an approximate reference model. In all assays the logit-log interpolation model exhibited the best correlation with the spline approximation model. In the steroid assays the logit-log regression model was found to be inferior to the other models; in the peptide assays it was equal to or superior to the semi-logarithmic interpolation model. The study on the physicochemical parameters of the antigen-antibody reactions demonstrated that affinity of steroid antibodies was much lower than that of the peptide antibodies. Consequently the degree of antibody saturation at zero dose in the routine peptide assays was greater than 50% and in the routine steroid assays was less than 50%. The relationship of assay characteristics to the applicability of particular curve-fitting models is discussed.

Adrenal Cortex Hormones↗

Simple computer program for a low-cost desk-top calculator applied to the evaluation of gas-liquid chromatographic analyses of 17-ketosteroids and pregnanes.

A simple computer program consisting of 445 steps for a low-cost desk-top calculator (Hewlett-Packard 97) to be applied in chromatographic analyses of 17-ketosteroids and pregnanes from human urine samples is described. This program permits the calculation of peak factors following the chromatographic separation of an external standard mixture containing up to ten different fractions, the subsequent printout of the constants and their transcription to magnetic data cards for later retrieval when making calculations for unknown samples. After manual input of sample constants (such as total and aliquot volumes, recovery as determined by addition of radioactive tracer steroid, internal standard) and peak factors via the data card, the individual peak heights of the samples are automatically converted to milligrams of steroid in 24-h urine and each is stored separately. All fractions can be recalled later and printed out in the order of detection or can be transformed into several diagnostically valuable parameters such as the total sum of 17-ketosteroids and pregnanes excreted, the group sums of androgens, of 11-substituted steroids and of pregnanes, the individual percentages of both the fractions and the group sums, and the ratios of aetiocholanolone-androsterone and of pregnanetriol-pregnanediol. Finally, an extension subprogram can automatically generate a plot to illustrate the steroid excretion pattern in a comprehensive fashion.

17-Ketosteroids↗

[Fatigue estimation of visual display terminal (VDT) workers by physiological data--preliminary study of a new computer program for VDT work analysis].

The methods for assessing VDT workload based on individual capabilities are necessary to evaluate general fatigue by VDT work. We have developed a new computer program for assessing data entry performance of each individual. Four healthy male volunteers conducted a data entry task at their own pace using this program under a controlled environment. They performed the task for 30 minutes twice with 10 minutes rest between them. As a result, the average number of inputs was 133.2 characters/min in the first task and 129.1 characters/min after taking the rest. The error rate was 8.6% and 10.6% in each task. This program was useful to evaluate their data entry performance. We also reported our concern with a drop in nasal skin temperature that was observed during these VDT tasks.

Adult↗

PRIMROSE: a computer program for generating and estimating the phylogenetic range of 16S rRNA oligonucleotide probes and primers in conjunction with the RDP-II database.

We describe PRIMROSE, a computer program for identifying 16S rRNA probes and PCR primers for use as phylogenetic and ecological tools in the identification and enumeration of bacteria. PRIMROSE is designed to use data from the Ribosomal Database Project (RDP) to find potentially useful oligonucleotides with up to two degenerate positions. The taxonomic range of these, and other existing oligonucleotides, can then be explored, allowing for the rapid identification of suitable oligonucleotides. PRIMROSE includes features to allow user-defined sequence databases to be used. An in silico trial of the program using the RDP database identified oligonucleotides that described their target taxa with a degree of accuracy far greater than that of equivalent currently used oligonucleotides. We identify oligonucleotides for subdivisions of the Proteobacteria and for the Cytophaga-Flexibacter-Bacteroides (CFB) division. These oligonucleotides describe up to 94.7% of their target taxon with fewer than 50 non-target hits, and the authors recommend that they be investigated further. A comparison with PROBE DESIGN within the ARB software package shows that PRIMROSE is capable of identifying oligonucleotides with a higher specificity. PRIMROSE has an intuitive graphical user interface and runs on the Microsoft Windows 95/NT/2000 operating systems. It is open source and is freely available from the authors.

Algorithms↗

[Computer program for antiglaucomatous surgeries analysis].

Computer analysis of long-term results of the surgical treatment of glaucoma needs suitable program for database data download retrospectively and prospectively as well. We composed a universal database program Glaucoma Access 97 for patients' follow-up in glaucoma surgery centers. Data about 1073 antiglaucomatous filtering surgeries from the period 1990-2000 were downloaded. The program permits to download data about the patients before the surgery, details about the operation procedure, and from the follow-up visits into the database using special software questionnaire sheets. Outcome from the database may be data about long-term IOP compensation, visual acuity changes, and treatment after the surgery. Evaluation of the data allows to follow up the successfulness of the treatment of specified groups of patients and to compare results of surgeons and individual departments as well.

Databases as Topic↗

[The Caceres-USPHS (version HP-3) computer program. Evaluation of automatic analysis of 40,000 ECG (author's transl)].

The main features of Caceres-USPHS (version HP-3) program for automatic analysis of the ECG are reviewed. Our experience at the Ospedale Regionale di Udine has now reached a total of 40,000 tracings analyzed by such a program and with an HP 1530-A computer system. In a detailed study of 1,000 consecutive computer-analyzed tracings reviewed by three experienced cardiologists, 534 were normal and 466 abnormal. A high degree of specificity was detected in the normal group (only 1.5% of false negatives) while the sensivity was rather low. In the abnormal group there were 18.1% of false positives and while the agreement was 100% in complete bundle branch block and some types of infarction, it was 56% in atrial fibrillation and 47% in incomplete right bundle branch block. Program errors were more common in measurements and pattern recognition; they were unusual in the program logic (0.3%). A significant improvement over comparable data obtained one year previously was attributed to a better quality control in data recording and to increase physician acceptance of the program diagnostic criteria. On the current and past figures of accuracy, it is concluded that the version HP-3 of Caceres-USPHS program represents a step forward in computer-derived ECG interpretation. However more progress is still needed for a larger and more profitable clinical application of this ECG computer program.

Computers↗

Computer programs for nucleic acids studies. Atomic coordinates of helices and their graphic display.

For the purpose of calculation of NMR and other physiocochemical properties of nucleic acids, a computer program in FORTRAN language has been written. This program provides the printout of the Cartesian and cylindrical coordinates of all atoms of a double-stranded helix of nucleic acid in either A, A' or B conformation with any specified base sequence up to 50 nucleotides or longer. In addition, the interatomic distances between any two atoms or distances (with both perpendicular and parallel components) from the centers of the base rings to any atom in the helix can be calculated. This information has been used for the calculation of the ring current effects of the 1H chemical shift of two short helices. Satisfactory agreement has been found in the comparison between the present data and that obtained from model construction and from the table prepared by Arter and Schmidt. The structure of the helix can also be illustrated in graphic form on a Tektronix 4006 CRT terminal. The presentation can be manipulated, such as selection, enlargement, translation and rotation.

Computers↗

MAPAG: a computer program to construct 2- and 3-dimensional antigenic maps.

The contact area between an antibody (Ab) and the antigen (Ag) is called antigenic determinant or epitope. The first step in the characterization of an Ag by using monoclonal antibodies (MAb) is to map the relative distribution of the corresponding epitopes on the Ag surface. The computer program MAPAG has been devised to automatically construct antigenic maps. MAPAG is fed with a binary matrix of experimental data indicating the ability of paired MAb to bind or not simultaneously to the Ag. The program is interactive menu-driven and allows the user an easy data handling. MAPAG utilizes iterative processes to construct and to adjust the final map, which is graphically shown as a 2- or a 3-dimensional model. Additionally, the antigenic map obtained can be optionally modified by the user or readjusted by the program. The suitability of MAPAG was illustrated by running experimental data from literature and comparing antigenic maps constructed by the program with those elaborated by the investigators without the assistance of a computer. Furthermore, since some MAb could present negative allosteric effects leading to misinterpretation of data, MAPAG has been provided with an approximate reasoning module to solve such anomalous situations. Results indicated that the program can be successfully employed as a simple, fast and reliable antigenic model-builder.

Algorithms↗

PEDMEANS: a computer program for the interpretation of pediatric electrocardiograms.

The interpretation pediatric electrocardiograms (ECGs) is complicated because of the strong age-dependency of the diagnostic criteria. We wanted to develop and evaluate a computer program for the interpretation of pediatric 12-lead ECGs. Continuous age-dependent normal limits were established based on ECGs from 1,912 healthy Dutch children. Additionally, a reference interpretation was obtained for 1,718 ECGs recorded at the Sophia Children's Hospital. The total set of ECGs was divided in a training set of 1076 ECGs and a test set of 642 ECGs. All ECGs were recorded at a sampling rate of 1,200 Hz. Based on the normal limits and the training set, diagnostic rules were formalized in an iterative process by using expert interviews and automatic rule induction. The resultant rules were evaluated on the test set. The performance of the program, on our study population, appears to justify its use in a clinical setting. Preferably, the program should also be evaluated in other clinical centers.

Algorithms↗

PINTRACE: a computer program for assessment of pin positions in routine radiographs of femoral neck fractures.

A new method for determination of pin positions in internally fixated femoral neck fractures is described. In AP and lateral radiographs of the hip, measurements are made of the cervicofemoral angles, the diameter of the femoral head and neck, and the distances from the central femoral neck axis to each pin. From these values the positions of the fixation pins in defined straight AP and lateral projections are determined by geometric calculations. A computer program in BASIC was developed to perform the calculations and to produce graphic displays of cross-sections of the femoral head and neck with the corrected pin positions indicated. For routine radiographic examinations with unknown inclination angles of the X-ray beams, the error of the method is less than 5% of the femoral head diameter. With conventional methods of determining pin positions the error can exceed 25% of the femoral head diameter.

Algorithms↗

PROBFIND: a computer program for selecting oligonucleotide probes from peptide sequences.

Synthetic oligonucleotides have proven to be extremely useful probes for screening cDNA and genomic libraries. Selection of the appropriate probe can be more easily and accurately achieved with the use of the computer program PROBFIND. The user enters the amino acid sequence from a file or from the keyboard, selects the minimum length allowed for the probe and the maximum allowable degeneracy. The computer prints a list of the sequences of potential probes which meet these minimum specifications and the location of the corresponding sequence in the protein to the screen and to a file. The user may modify the specifications for length and degeneracy at any time during the output of data, which allows for rapid selection of the desired probe. The program is interactive, accepts any file format with only a single modification of the file, is written in BASIC, and requires less than 6 kbytes of memory. This makes the program easy to use and adaptable even to unsophisticated microcomputers.

Amino Acid Sequence↗

HLA-D typing with lymphoblastoid cell lines. VII. A computer program for data analysis.

When lymphoblastoid cell lines (LCL) are substituted for peripheral blood lymphocytes from human typing cell donors in HLA-D typing experiments, a data analysis program must be designed to distinguish the effect of allo-reactivity from those peculiar to LCL, mainly the "autologous-stimulation" effect. The computer program described in this report was created specifically for such an analysis. The rationale for the design of this program is presented in the preceding report (see this issue).

Cell Line↗