PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Counterpulsation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

The evolution of counterpulsation techniques.

Assisted circulation techniques are an outgrowth of extracorporeal pump oxygenator systems developed in the mid 1950s. But the differences in physiology of total perfusions and of parital perfusions for assisting circulation delayed the clinical application of the intra-aortic balloon. The problems and risks in providing circulation assistance and the approaches used to overcome them are discussed. The various counterpulsation techniques are described and data presented to demonstrate the increased survival in patients with myocardial infarction and cardiogenic shock.

Assisted Circulation↗

Update on skeletal muscle ventricles as aortic diastolic counterpulsators.

Skeletal muscle ventricles are constructed from canine latissimus dorsi muscle. These skeletal muscle ventricles can be placed subcutaneously on the chest wall or inside the chest cavity. Skeletal muscle ventricles are connected to the descending thoracic aorta and activated to pump blood as aortic diastolic counterpulsators. The skeletal muscle ventricle in 1 animal pumped blood in the circulation for 27 months. Skeletal muscle ventricles can also function effectively under the condition of low cardiac output. Although thrombus has been detected in some skeletal muscle ventricles, thromboembolism to distal organs has been detected only rarely during the past few years. This research appears promising; however, skeletal muscle ventricle rupture remains a problem and currently accounts for about 30% of the mortality in the long-term experiments. It occurs at the site between the skeletal muscle ventricle outlet and the Dacron sewing ring that is necessary to connect conduits from the skeletal muscle ventricle to the animal's circulation. We believe that skeletal muscle ventricle rupture is likely to be a solvable problem. Once a solution has been found, skeletal muscle ventricles may be ready for clinical use in patients with chronic congestive heart failure.

Animals↗

[Newly-developed catheter for cardio-renal assist during intraaortic balloon counterpulsation].

A new catheter was developed for the cardio-renal assist during intra-aortic balloon counterpulsation. The catheter consists of both a large balloon of conventional IAB (TMP balloon) located at the distal end of the catheter and an additional small balloon 10 cm distant from the large balloon with common lumen and single shaft. Experimental study was carried out in the mock circulatory system simulating the descending aorta employing a conventional IAB catheter as a control. It was demonstrated that the flow in the mid portion between both balloons could be increased maximally by as much as 28% of that of the control under the continuous flow and 214% under the pulsatile flow. The double balloon catheter was considered to improve the renal perfusion as well as the coronary perfusion.

Assisted Circulation↗

Experimental study of extraaortic balloon counterpulsation as a bridge to other mechanical assists.

A special extraaortic balloon was developed that can be placed around the ascending aorta. This balloon can easily support the heart temporarily in a median sternotomy field, especially in cases in which it is difficult to use intraaortic balloon pumping because of peripheral arterial disease. The goal of this study was to judge the applicability of this extraaortic balloon counterpulsation. An extraaortic balloon was placed around the ascending aorta of eight adult canines. Two heart failure models were used in this study: group A-moderate heart failure; group B-severe heart failure. In group A, the aortic systolic pressure was significantly reduced (9.3%, p < 0.01), but in group B, there was no significant change. In group A, there was a significant increase in cardiac output (12.0%, p < 0.01), but in group B, there was no significant change. The endocardial viability ratio in both groups significantly increased (group A: 11.3%, p < 0.01; group B: 11.9%, p < 0.05). An extraaortic balloon around the ascending aorta is easily applicable through a median sternotomy, and can be used as a bridge to more powerful mechanical assists when intraaortic balloon pumping cannot be used.

Animals↗

Intra-aortic balloon counterpulsation timing.

Intra-aortic balloon counterpulsation is a product of an endeavor begun more than 3 decades ago. First the concept, then applications of inflating a nonthrombogenic balloon within the aorta during diastole were explored. The intra-aortic balloon is timed to inflate with aortic valve closure. Two options are available for deflation timing: (1) conventional timing, where deflation is estimated to be completed at some point during isovolumetric contraction, prior to ejection; and (2) R wave deflation, also known as real timing, where deflation is triggered by each QRS complex to occur during isovolumetric contraction or early systole. Although clinical implementation of both conventional and real timing was introduced in 1968, limited information about these methods of deflation is currently available. This article elucidates the differences between these models and suggests implications for clinical practice and further research.

Blood Pressure↗

[Short and intermediate term clinical outcome in patients with cardiogenic shock treated with aortic counterpulsation].

BACKGROUND: Despite improvements in coronary care, cardiogenic shock (CS) remains the leading cause of death in patients with dramatic cardiac diseases of which acute myocardial infarction (AMI) is the most frequent event. Conventional therapy for CS with coronary care unit (CCU) monitoring and vasopressor agents to support blood pressure has historically been associated with an 80% to 90% mortality rate in large series. Intra-aortic balloon pump (IABP) therapy for shock results in initial favourable clinical and haemodynamic responses, but ultimately, in most patients, death is merely delayed and hospital mortality still exceeds 80%. In several recent non-randomised series, coronary revascularisation performed early in the course of CS with the use of coronary artery by-pass grafting (CABG) or coronary angioplasty (PTCA) resulted in an apparent reduction in the hospital mortality rate to less than 50% in selected patients with shock. OBJECTIVES: This study reviews our experience of cardiogenic shock treatment at a time when standard care included aggressive use of the intra-aortic balloon pump counterpulsation, cardiac catheterisation, coronary angioplasty and/or coronary artery by-pass grafting, ventricular septal defect and mitral incompetence repair. METHODS: We retrospectively analysed 20 patients (13 M and 7 F, with an average age of 62 years and a half) affected by cardiogenic shock consecutively admitted to our CCU between October 1, 1992 and April 1, 1995. Fifteen patients (pts) were hospitalised for AMI, shock and pump failure (2 of them with pulmonary oedema), all with admittance delay less than 24 hours. Five patients were hospitalised for AMI with shock and mechanical defects, of which 3 pts with AMI and ventricular septal rupture and 2 pts with AMI and mitral regurgitation. All patients underwent IABP, coronary angiography (CA) and then were treated with PTCA, CABG and cardiac surgery or medical treatment. RESULTS: On the whole, 7 pts died (35%): 4 of shock, 1 of haemorrhagic complications, 1 of septic shock in the CCU, and 1 of heart failure after CABG in cardiosurgery. One more patient died of heart failure two months after discharge (late mortality 5%). Out of the 15 patients hospitalised with AMI, shock and pump failure, 13 patients with AMI and CS less than 24 hrs were treated as follows: 1 patient was successfully submitted to emergency CABG and 12 patients to PTCA of the infarct related artery (IRA). Eight patients enjoyed a good outcome, but 1 patient died of haemorrhagic complications and 4 with a persistently occluded IRA also died (3 in the CCU and 1 after CABG). Of the 2 remaining pts with AMI, shock and pulmonary oedema, 1 patient underwent CABG with success and 1 patient with the 3-vessel disease was submitted to PTCA with reperfusion of the IRA, but he died from reocclusion three days later. Out of the 5 patients with AMI, shock and mechanical defects, 3 patients with AMI and septal ventricular rupture underwent cardiac surgery and CABG with early and late success. One of the 2 patients with AMI, shock and mitral regurgitation underwent cardiac surgery with valve repair and CABG and had a good outcome, the other died from septic complications in the CCU. CONCLUSIONS: IABP is an useful device for stabilising patients in cardiogenic shock and safely performing angiography as well as PTCA, CABG or surgical correction of all mechanical complications with a more stable haemodynamic balance. Therefore, IABP is an useful tool to improve successful coronary revascularisation after direct PTCA or direct CABG. These data also suggest that the combination of successful coronary revascularisation and intra-aortic balloon pumping can improve survival in pts with cardiogenic shock complicating AMI with early pump failure.

Aged↗

Computer analysis of external counterpulsation by use of a nonlinear mathematical model of the cardiovascular system.

A pressure system externally applied to the limbs of a patient has been proven effective in assisting circulation in animal and clinical studies. In this study a nonlinear mathematical model of the cardiovascular system is utilized to determine the effectiveness of high-frequency components in the external pressure waveform. The development of the model, the method of analysis, and the results acquired with the model are presented in this report, demonstrating its suitability for the study of external counterpulsation.

Animals↗

Counterpulsation with a new pulsatile assist device (PAD) in open-heart surgery.

A new pulsatile assist device that converts roller pump flow to pulsatile flow has been developed and proven effective through clinical testing. The PAD is also a hemodynamically effective arterial counterpulsator both before and after cardiopulmonary bypass. The PAD has been found to be an important adjunct to the care of critically ill patients undergoing open-heart surgery. In addition, in selected patients, the PAD is a reasonable alternative to the elective use of intra-aortic balloon pumping.

Adolescent↗

Percutaneous transluminal coronary angioplasty for rest angina pectoris requiring intravenous nitroglycerin and intraaortic balloon counterpulsation.

In selected patients with medically refractory rest angina, percutaneous transluminal coronary angioplasty (PTCA) might be a reasonable alternative to coronary artery bypass graft surgery. Between January 1987 and November 1989, 1 operator at a Veterans Administration center performed PTCA on 73 vessels in 56 patients with rest angina of sufficient severity to require intravenous nitroglycerin in all 56 and intraaortic balloon counter-pulsation (IABP) in 18. Of the 56 patients, 17 (30%) had 1-vessel disease, 14 (25%) had 2-vessel disease and 25 (45%) had 3-vessel disease; 14 (25%) had greater than or equal to 1 prior bypass surgery, 35 (62.5%) were within 30 days of an acute infarction, 12 (21%) had left ventricular ejection fraction less than 0.50 and 7 (12.5%) were greater than 70 years of age. PTCA was successful in 61 (84%) vessels and 47 (84%) patients (greater than or equal to 1 vessel plus relief of angina). During index hospitalization, there were 2 deaths (3.6%), 4 myocardial infarctions (7.2%), 4 emergent bypass surgeries (7.2%) and 1 semiemergent bypass (1.8%) for technically unsuccessful PTCA. In follow-up from 3 to 36 months, there has been 1 additional myocardial infarction (1.8%), 1 late death (1.8%), 2 repeat PTCAs (3.6%), 6 crossovers to bypass (10.7%) and 38 patients (68%) have remained cardiac-event free. Although this angioplasty cohort is small and selected, these data raise the possibility that a prospective randomized comparison of PTCA versus bypass surgery might be feasible and appropriate in a subset of unstable angina patients who require intravenous nitroglycerin or IABP.

Adult↗

Outcome and complications of prolonged intraaortic balloon counterpulsation in cardiac patients.

The risks and benefits of prolonged intraaortic balloon support for the management of refractory congestive heart failure and ischemia were studied in patients with end-stage heart disease who needed support for greater than or equal to 5 days. Fifty-two insertions were performed by the percutaneous femoral route in 49 patients. The duration of insertion ranged from 5 to 46 days (mean 11.3). Clinical outcome including hemodynamic parameters and complications were recorded. Mean systemic arterial pressure did not change with balloon insertion (74 +/- 19 vs 76 +/- 11 mm Hg; p = not significant). Both the mean pulmonary artery and pulmonary arterial wedge pressures decreased (33 +/- 8 to 26 +/- 9 mm Hg [p less than 0.01], and 25 +/- 8 to 17 +/- 6 mm Hg [p less than 0.01], respectively). Over time, both parameters tended to increase, but remained significantly less than those before insertion. Cardiac index increased from 1.6 +/- 0.4 to 2.2 +/- 0.5 liters/min/m2 on insertion and continued to increase to 2.7 +/- 0.5 liters/min/m2 (p less than 0.01) before removal. Definite balloon catheter infection developed in 7 patients, and hemorrhage occurred in an additional 7. Eleven patients had vascular compromise, with loss of pulse in 6, thrombosis of the femoral artery in 1, and pseudoaneurysm in 2. Lacerated femoral artery occurred in 1 patient, and mesenteric artery thrombosis in another. Twenty patients died from progressive heart failure and multiorgan system failure, and 19 survived to receive left ventricular assist device and heart transplantation. Only 10 patients were weaned off the balloon. In conclusion, prolonged intraaortic balloon pump support may be successfully used in end-stage heart disease.

Adolescent↗