PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture Precision Attachment”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

An 8-year follow-up of removable partial denture treatment performed by the Public Dental Health Service in a Swedish county.

The aim of the present study was to evaluate clasp-retained removable partial dentures (RPDs) made in the Public Dental Health Service (PDHS) in Orebro County in 1989. Records from all 25 PDHS clinics concerning RPDs from 1989 were collected after eight years and available information was registered. The entire material consisted of 447 RPDs (both attachment-retained and clasp-retained RPDs) in 387 patients. Of the 316 clasp-retained RPDs that were traceable, 208 were followed from 1989 to 1997. In most instances, information on diagnoses, alternative treatments and design of the RPDs was lacking. One hundred and thirty-two (42%) of the 316 clasp-retained RPDs were judged to still be in use in 1997 while 75 were not in use. The main reason for ceased use was dislike by the patient. There were 108 clasp-retained RPDs that were not possible to follow from 1989 to 1997 because there were no notes regarding follow-ups in the records. The most common technical complications noted in the records during the observation period were clasp fractures and loosened artificial teeth.

Dental Clasps↗

Mandibular overdentures anchored to single implants: a five-year prospective study.

STATEMENT OF PROBLEM: It is unknown what minimum number of implants are required to satisfactorily support and retain a mandibular overdenture. PURPOSE: The purpose of this study was to evaluate a treatment modality by using mandibular overdentures anchored to single implants in a geriatric patient population. MATERIAL AND METHODS: Twenty-one patients with a mean age of 74.2 years were treated with single implants inserted at the mandibular midline according to the standard two-stage surgical technique. O-Ring or ball attachments were connected to the implants and served as overdenture anchorage. Implant success rate, improvement of oral comfort and function, condition of the peri-implant soft tissues, Periotest values, and the interproximal marginal bone level were evaluated for up to 5 years after delivery of the overdentures. RESULTS: None of the implants were lost during the follow-up period. A mean marginal bone loss of 1.42 +/- 0.56 mm was noted at 60 months. Plaque Index was consistently high around the abutments at all reevaluation intervals but was associated with a low Gingival Index. Pocket Depth averaged 2.41 +/- 0.17 mm for the entire follow-up period. Remarkable improvement of oral comfort and function were evidenced with the overdenture treatment. CONCLUSION: Rehabilitation with mandibular overdentures anchored to a single implant can be a therapeutic alternative for elderly patients experiencing discomfort and functional difficulties with conventional mandibular dentures.

Aged↗

A retrospective evaluation of treatments with implant-supported maxillary overdentures.

BACKGROUND: Considerably lower success rates have been presented for implant-supported overdentures in the maxilla compared with the mandible. PURPOSE: The aim of the study was to report the outcome of implant-supported maxillary overdentures from one clinic. METHODS: All patients treated with implant-supported maxillary overdentures in the Department of Prosthetic Dentistry, Central Hospital, Skövde, Sweden, between 1993 and 2002 were identified from patient charts and included in the study. All patients had a rigid cast gold alloy bar designed with ball attachments retaining an overdenture. RESULTS: Twenty-seven subjects were included, of whom 13 were originally planned for overdenture treatment (group 1) and the other 14 for a fixed prosthesis (group 2). The mean observation period was 5.7 years for subjects in group 1 and 5.5 years for those in group 2. One hundred forty-five implants were placed, and the majority of the failures were diagnosed as early ones and were found in group 2. The cumulative implant survival rate after 5 years was 77% in group 1 and 46% in group 2. The probability of having implant failure was almost three times higher among subjects in group 2 compared with subjects in group 1. Most technical and biologic complications were related to the retention system. CONCLUSION: Maxillary implant-supported overdentures show a high implant failure rate, but fewer implant failures occurred for patients originally planned for overdenture treatment.

Aged↗

Comparison of retention and release periods for implant overdenture attachments.

The aim of this study was to compare the retention and release periods of the Nobel Biocare bar and clip (NBC), Nobel Biocare ball (NB), Zest anchor (ZA), Zest magnet (ZM), and Sterngold ERA (SE) attachments on an implant-retained overdenture model. The attachments were tested using two permanently placed Brånemark implants on a test model that was attached to an Instron machine (cross-head speed 50.8 mm/minute). Each attachment had one part embedded in a denture-like housing, and the other part screwed into the implants. Dislodging tensile forces were applied to the housings in two directions simulating function: vertical and oblique. Eight tests were done in two directions with three samples of each attachment. The dislodging forces generated measurements of the peak load, break load, and displacement at peak load and break load. Release periods were calculated using displacements between the peak load and break load and the cross-head speed. Results showed the NBC to be significantly most retentive for the break load when subjected to vertical and oblique forces with mean values and standard deviations of 2104.5 +/- 506.7 g and 1958.1 +/- 165.4 g, respectively. Next most retentive was the SE, followed by the ZA and NB. The ZM was significantly least retentive (127.8 +/- 7.0 g and 143.5 +/- 19.7 g). For the release period, results showed the NBC to have significantly the fastest release period for vertical and oblique forces (1.86 x 10(-3) and 7.35 x 10(-4) minutes). The ZM significantly had the slowest release period for those forces (3.02 x 10(-2) and 2.35 x 10(-2) minutes). The data suggested that the NBC could be selected when a higher degree of retention and fast release period are desired. The next most retentive was the SE; ZM was the least retentive and had the slowest release period.

Dental Abutments↗

Effect of implant angulation upon retention of overdenture attachments.

INTRODUCTION: Overdentures supported and retained by endosteal implants depend upon mechanical components to provide retention. Ball attachments are frequently described because of simplicity and low cost, but retentive capacity of these components may be altered by a lack of implant parallelism. PURPOSE: The aim of this in vitro study was to investigate the retention of gold and titanium overdenture attachments when placed on ball abutments positioned off-axis. METHODS AND MATERIALS: Four ball abutments were hand-tightened onto ITI dental implants and placed in an aluminum fixture that allowed positioning of the implants at 0 degrees, 10 degrees, 20 degrees, and 30 degrees from a vertical reference axis. Gold and titanium matrices were then coupled to the ball abutments at various angles and then subjected to pull tests at a rate of 2 mm/second; the peak loads of release (maximum dislodging forces) were recorded and subjected to statistical analyses. A balanced and randomized factorial experimental design testing procedure was implemented. RESULTS: Statistically significant differences in retention of gold matrices were noted when ball abutments were positioned at 20 degrees and 30 degrees , but not at 0 degrees and 10 degrees. Statistically significant differences were noted among the titanium matrices employed for the testing procedure, as well as for the 4 ball abutments tested. Angle was not a factor affecting retention for titanium matrices. CONCLUSIONS: (1) The gold matrices employed for the testing procedures exhibited consistent values in retention compared to titanium matrices, which exhibited large variability in retention. (2) Angle had an effect upon the retention of gold matrices, but not for titanium matrices.

Analysis of Variance↗

Effects of resistance form on attachment strength of resin-retained castings.

This study evaluated the effects of tooth preparation design on resistance to dislodgment of a resin-bonded fixed partial denture (RBFPD). The variations of tooth preparation tested included axial coverage, retentive grooves, and an occlusal rest. Patterns of the tooth preparation designs were prepared and cast in a base metal alloy. Retainer patterns were waxed to refractory casts of metal dies, cast, finished and then bonded to the dies. The complete assemblies were loaded to failure on an Instron mechanical testing machine, and analysis indicated that retainers with occlusal rests were the most resistant. Grooves provided no statistically significant increase in resistance to failure of the cement. Increased axial coverage did not increase resistance to dislodgment. Successful fixed partial dentures (FPDs) depend on cast retainers to resist displacement of the restoration during function. Introduction of resin-bonded restorations opened the possibility of FPDs with minimal reduction of abutments. Specific questions concerning long term success and tooth preparation designs were prominent concerns. The influence of resistance form on overall stability of a restoration was also of particular interest. Buonocore established the foundation for retention of composite resins to acid-pitted enamel. Rochette used this technology to bond perforated cast metal splints to periodontally compromised teeth. A mechanical interlock was created as composite resin engaged these perforations and sustained the cast splint to acid-etched enamel. Howe adapted this design for replacement of anterior teeth by adding porcelain to a metal ceramic framework and then bonding the framework to abutments without tooth preparations. The advantages of these procedures were their conservative nature, esthetics, and ease of rebonding after dislodgment. Livaditis and Thompson adapted the procedure proposed by Tanaka of corrosion-pitting the bonding surface of a base metal alloy. They increased the surface area to be bonded, eliminated the perforations to improve rigidity of the framework, and described tooth preparation modifications of the abutments. They suggested an occlusal rest, establishment of guide planes through axial reduction, and a proximal extension to the facial surface to resist lingual displacement. Simonson, et al., based their anterior tooth preparation design on the configuration suggested by Livaditis which included a slight chamfer finish line plus reduction of the lingual surface to provide a thicker metal framework. Barrack introduced an inlay type tooth preparation for the occlusal rest plus shallow vertical proximal grooves, and Meiers used grooves as an esthetic alternative to proximal extensions. Clinical studies and surveys have identified specific variables involved with success and failure, while in vitro studies have evaluated framework designs, bonding agents, and methods for pitting the metal surface. This study evaluated resistance of RBFPDs to dislodgment of different tooth preparation designs.

Analysis of Variance↗

Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures.

The aim of this retrospective study was to examine the condition and success rate of various designs of removable partial dentures 10 years after placement. Seventy-four patients treated with 101 mainly conical crown-retained dentures (CCRDs), clasp-retained removable partial dentures (RPDs), or a combination of conical crown and clasp-retained dentures (CRPDs) were reexamined. Prosthetic findings were compared to baseline values at insertion and checked for factors that may affect them. Overall, 36.6% of the prostheses were regarded as successes, 23.8% as partial successes, and 39.6% as failures. Also, only one-third of the prostheses showed neither hygienic problems nor technical failures. The statistical analysis identified no single parameter as significantly affecting the success rate of the partial dentures. Prostheses supported by several abutment teeth had improved success, and RPDs had a higher failure rate (66.7%) than CCRDs (33.3%) and CRPDs (44.8%); however, because of the limited number of RPDs these differences were not statistically significant. Although the prostheses were unsupervised in service, the 60.4% overall success rate of the dentures was somewhat higher than in other studies on precision-retained prostheses.

Chi-Square Distribution↗