PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Mobile Applications”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Administration of macrophage colony-stimulating factor mobilized both CD11b+CD11c+ cells and NK1.1+ cells into peripheral blood.

We attempted the phenotypic characterization of peripheral blood (PB) cells after daily administration of macrophage colony-stimulating factor (M-CSF) in mice. The number of CD11b+ cells was increased by M-CSF treatment (2- and 5-day injections). Notably, CD11bbrightCD11cdim, CD11b+CD11c+ and CD11b+CD80+ cells were significantly increased by 2-day treatment of M-CSF. On the other hand, the number of NK1.1+ cells was not changed by the 2-day treatment, but it was significantly increased by the 5-day treatment. However, the numbers of CD3+ and NK1.1+CD3+ cells were not changed by M-CSF treatment. Then, mononuclear cells (MNCs) were separated from the PB of mice treated with saline or M-CSF, and they were incubated with GM-CSF + IL-4 or IL-2. Compared with the saline-treated one (S-MNCs), the MNCs of M-CSF-treated mice (M-MNCs) showed strong proliferation by the GM-CSF + IL-4 stimulation. The MNCs could stimulate proliferation of allo-T cells in the mixed lymphocyte reaction (MLR), especially the M-MNCs showed strong reaction. On the other hand, the stimulation by IL-2 induced strong cell growth of MNCs. And M-CSF treatment enhanced this response. Furthermore, the M-MNCs (stimulated by IL-2 in vitro) exhibited greater cytotoxicity against Yac-1 cells than the S-MNCs. In conclusion, we found that administration of M-CSF mobilized CD11b+, CD11b+CD11c+, CD11b+CD80+, and NK1.1+cells into PB. And the injection of M-CSF facilitates the generation of dendritic and natural killer cells from PB cells in vitro. These results suggest that the mobilized cells may provide for application of immunotherapy.

Animals↗

Identification of trimethyllead in urine by high-performance liquid chromatography with column switching and chemical reaction detection and by liquid chromatography-mass spectrometry.

Incorporated tetraalkyllead compounds are metabolized in the liver and the highly toxic trialkyllead species are excreted via the urine. The procedure for the determination of these metabolites in urine consists of solid-phase enrichment, reversed-phase pre-column high-performance liquid chromatography (HPLC) and chemical reaction detection. As urine is a very complex matrix, it must be questioned whether the retention time alone is a sufficient criterion for the identification of the analytes. For the trimethyllead ion the validity of the results was examined by selectivity checks of the chemical reaction detector, by the application of different stationary and mobile phases in single and dual pre-column HPLC systems and by the use of thermospray LC-mass spectrometry as an independent method. The results demonstrated that the recommended method is accurate for the determination of trimethyllead in urine samples.

Chromatography, High Pressure Liquid↗

Method for the separation of the unconjugates and conjugates of chenodeoxycholic acid and deoxycholic acid by two-dimensional reversed-phase thin layer chromatography with methyl beta-cyclodextrin.

A simple and efficient method for the separation of individual unconjugated bile acids and their glycine- and taurine-amidated, 3-sulfated, 3-glucosylated and 3-glucuronidated conjugates is described. The method involves the use of a two-dimensional (2D) reversed-phase (RP) high-performance thin-layer chromatographic (HPTLC) technique with methyl beta-cyclodextrin (Me-beta-CD). Five major unconjugated bile acids, chenodeoxycholic acid (CDCA), deoxycholic acid (DCA), ursodeoxycholic acid and lithocholic acid, and their conjugates were examined as the solutes. A high degree of separation of individual bile acids in each homologous series was achieved on a RP-HPTLC plate by developing with aqueous methanol in the first dimension and the same solvent system containing Me-beta-CD in the second dimension. In particular, all of the six 'difficult-to-separate' pairs, unconjugated CDCA and DCA and their conjugated forms with glycine, taurine, sulfuric acid, D-glucose and D-glucuronic acid, were effectively resolved by adding Me-beta-CD in the aqueous mobile phases with the formers having larger mobilities than the latter. The application of this 2D inclusion RP-HPLC method to the separation of glycine-conjugated bile acids in human bile is also described. The present method would be useful for separating and characterizing these bile acids present in biological materials.

Bile↗

[Acute pulmonary edema during nicardipine and salbutamol therapy for preterm labor in twin pregnancy].

We report the case of a 38-year-old parturient at 30 weeks 2 days term of a multiple pregnancy who experienced acute pulmonary edema more than 48 hours after tocolytic treatment with nicardipine and salbutamol. The patient was transferred from a level 1 perinatal center to a level 3 perinatal center by the Grenoble mobile intensive care unit in application of the in utero transfer protocol for preterm labor before 33 weeks with twin pregnancy. This case illustrates the risk of tocolytic treatment and potential adverse effects in the event of preterm labor on twin pregnancy. The question of associating a second tocolytic after failure of the first is also raised.

Adult↗

Simultaneous determination of free and conjugated bile acids in human gastric juice by high-performance liquid chromatography.

A high-performance liquid chromatographic procedure has been developed for the simultaneous assay of the major free bile acids and the corresponding glycine and taurine conjugates in man. No preliminary fractionation into the free, glyco- and tauro-conjugated forms was required. An Ultrasphere ODS column with UV detection at 210 nm and methanol-acetate buffer gradient elution were used. The retention volume of the conjugates was dependent on the sodium acetate concentration in the mobile phase. The method is applicable to the quantification of intragastric bile acids with satisfactory sensitivity, selectivity and precision. Unconjugated and conjugated bile acids present in the gastric juice of patients with bile reflux gastritis were determined directly after Sep-Pak C18 cartridge purification.

Bile Acids and Salts↗

Analysis of filter-paper-absorbed, finger-stick blood samples for chloroquine and its major metabolite using high-performance liquid chromatography with fluorescence detection.

Methodology has been developed to facilitate the collection, transport, and analysis of blood samples in studies of chloroquine absorption and metabolism. The method utilizes high-performance liquid chromatography (HPLC) with fluorescence detection to quantify chloroquine and its major metabolite, desethylchloroquine, in 100-microliters quantities of blood collected on filter paper. Detection limits are 5 ng/ml for both analytes. No loss of either analyte occurred from filter-paper-collected blood spots stored over a twelve-weeks' period at room temperature. Filter-paper-collected, finger-stick blood spots give values for each analyte comparable to corresponding determinations on venous, whole-blood samples. The HPLC mobile phase selected has general applicability to the separation of antimalarial drugs. The methodology permits effective assessment of chloroquine prophylaxis compliance and parasite drug resistance in remote, malaria-endemic regions.

Blood Specimen Collection↗

Ultrasensitive investigations of biological systems by fluorescence correlation spectroscopy.

Fluorescence correlation spectroscopy (FCS) extracts information about molecular dynamics from the tiny fluctuations that can be observed in the emission of small ensembles of fluorescent molecules in thermodynamic equilibrium. Employing a confocal setup in conjunction with highly dilute samples, the average number of fluorescent particles simultaneously within the measurement volume (approximately 1 fl) is minimized. Among the multitude of chemical and physical parameters accessible by FCS are local concentrations, mobility coefficients, rate constants for association and dissociation processes, and even enzyme kinetics. As any reaction causing an alteration of the primary measurement parameters such as fluorescence brightness or mobility can be monitored, the application of this noninvasive method to unravel processes in living cells is straightforward. Due to the high spatial resolution of less than 0.5 microm, selective measurements in cellular compartments, e.g., to probe receptor-ligand interactions on cell membranes, are feasible. Moreover, the observation of local molecular dynamics provides access to environmental parameters such as local oxygen concentrations, pH, or viscosity. Thus, this versatile technique is of particular attractiveness for researchers striving for quantitative assessment of interactions and dynamics of small molecular quantities in biologically relevant systems.

Biological Transport, Active↗

Application of the NMR-MOUSE to food emulsions.

The application of the NMR-MObile Universal Surface Explorer (NMR-MOUSE) to study food systems is evaluated using oil-in-water emulsions, and the results are compared to those obtained using a conventional low-field NMR (LF-NMR) instrument. The NMR-MOUSE is a small and portable LF-NMR system with a one-sided magnet layout that is used to replace the conventional magnet and probe on a LF-NMR instrument. The high magnetic field gradients associated with the one-sided MOUSE magnet result in NMR signal decays being dominated by molecular diffusion effects, which makes it possible to discriminate between the NMR signals from oil and water. Different data acquisition parameters as well as different approaches to the analysis of the NMR data from a range of oil-in-water emulsions are evaluated, and it is demonstrated how the concentration of oil and water can be determined from the NMR-MOUSE signals. From these model systems it is concluded that the NMR-MOUSE has good potential for the quantitative analysis of intact food products.

Emulsions↗

Development of a wet-chemical method for the speciation of iron in atmospheric aerosols.

The ability to quantify the chemical and physical forms of transition metals in atmospheric particulate matter (PM) is essential in determining potential human health and ecological effects. A method for the speciation of iron in atmospheric PM has been adapted which involves extraction in a well-defined solution followed by oxidation state specific detection. The method was applied to a suite of environmental aerosols. Ambient atmospheric aerosols in an urban area of St. Louis (the St. Louis-Midwest Supersite) were collected on Teflon substrates and were leached in one of four different solutions: (1) >18.0 Momega water; (2) 140 microM NaCl solution; (3) pH = 7.4 NaHCO3 solution; and (4) pH = 4.3 acetate buffering system. Fe(ll) was determined directly using the Ferrozine method as adapted to liquid waveguide spectrophotometry using a 1 m path-length cell. Fe(lll) was determined similarly after reduction to Fe(ll). It was found that, at low ionic strength, pH exerted a major influence on Fe(ll) solubility with the greatest Fe(ll) concentration consistently found in the pH = 4.3 acetate buffer. Soluble Fe(lll) (as defined by a 0.2 microm filter) varied little with extractant, which implies that most of the Fe(lll) detected was colloidal. To characterize well-defined materials for future reference, NIST standard reference materials were also analyzed for soluble Fe(ll) and Fe(lll). For all SRMs tested, a maximum of 2.4% of the total iron (Urban Dust 1649a) was soluble in pH = 4.3 acetate buffer. For calibration curves covering the ranges of 0.5-20 microg/L Fe(ll), excellent linearity was observed in all leaching solutions with R2 values of > 0.999. Co-located filters were used to test the effect of storage time on iron oxidation state in the ambient particles as a function of time. On two samples, an average Fe(ll) decay rate of 0.89 and 0.57 ng Fe(ll) g(-1) PM day(-1) was determined from the slope of the regression, however this decrease was determined not to be significant over 3 months (95% confidence). As an application of this method to mobile source emissions, size-resolved PM10 samples were collected at the inlet and outlet of the Caldecott Motor Vehicle Tunnel in northern California. These samples indicate that the coarse fraction (PM10-PM2.5) contains almost 50% of the total soluble Fe(ll) in the aerosol.

Aerosols↗

In vivo percutaneous absorption of hydrocortisone: multiple-application dosing in man.

Percutaneous absorption of hydrocortisone was measured in six healthy adult men from whom informed consent had been obtained. The study compared a single topical dose to multiple-topical dose treatments (one vs three applications) on the same day. 14C-Labeled hydrocortisone in acetone was applied to 2.5 cm2 of ventral forearm skin and protected with a nonocclusive polypropylene chamber. The amount of 14C measured in urine collected over 7 days was used to determine hydrocortisone absorption. The treatments, performed 2 to 3 weeks apart, each utilized adjacent sites on the same individuals. A single dose of 13.33 micrograms/cm2 delivered 0.056 microgram/cm2 of hydrocortisone through the skin. When the single dose was tripled to 40 micrograms/cm2, the amount delivered through the skin increased by nearly three times, from 0.056 to 0.140 micrograms/cm2; the expected delivery was 3 x 0.056 micrograms/cm2 = 0.168 microgram/cm2. Three serial doses of 13.33 micrograms/cm2 (total, 40 micrograms/cm2) were also expected to deliver 0.168 micrograms/cm2 with or without soap and water washing between doses, but the observed amount of hydrocortisone delivered through the skin significantly exceeded our expectations. This indicates that multiple-dosing treatments resulted in a significant increase in bioavailability. It is postulated that increased vehicle application and washing dissolved and mobilized previously dosed hydrocortisone and increased bioavailability.

Administration, Cutaneous↗

Technology insight: Use of ventricular assist devices in children.

Mechanical circulatory support systems for the treatment of end-stage heart failure are now available for a wide variety of clinical situations and support times. Extracorporeal membrane oxygenation and centrifugal pump circuits have been most widely used in children, particularly in small infants. These systems are preferred for support after cardiac operations and for use in patients who have concomitant respiratory failure, but are suitable for short-term application only and intensive care is obligatory. True ventricular assist devices (VADs) qualify for long-term application and allow patients full mobilization. These features are important in patients awaiting heart transplantation as well as in those with myocarditis and cardiomyopathy, who might achieve complete cardiac recovery. Pneumatic pulsatile VADs have been available in pediatric sizes since 1992. At our institution, VAD use lasting from several days to 14 months in 70 infants and children with myocarditis and cardiomyopathy has led to a notable rise in survival in the past 5 years. We have been able to discharge 78% of the infants under 1 year old. In this review we present current VAD experience in children in the light of improvements in decision making, device technology, implantation techniques, and in coagulation monitoring and anticoagulation.

Cardiac Surgical Procedures↗

Plaster of Paris: the forgotten hand splinting material.

This article examines the concept of tissue adaptation in response to the application of plaster of Paris splints and casts. A review of the history of plaster of Paris and its composition, its working properties, and precautions for its use introduces the reader to this oft-forgotten material. Four designs are described for plaster of Paris application-circumferential padded casts, digital unpadded casts, plaster slabs, and contour molds. The discussion of clinical application of plaster of Paris covers joint tightness, arthritis, contracted joints due to spasticity, muscle-tendon tightness, skin tightness, skin and joint tightness, and edema reduction. In addition, a new application called casting motion to mobilize stiffness (CMMS), developed by the author, is discussed. The use of plaster of Paris to improve postoperative flexor tendon glide is also discussed. This review article intends to stimulate the reader to use plaster of Paris splinting or casting more frequently to solve clinical problems.

Calcium Sulfate↗

The validity and applicability of the Chinese version of the Quebec User Evaluation of Satisfaction With Assistive Technology for people with spinal cord injury.

The Quebec User Evaluation With Assistive Technology (Version 2.0; QUEST 2.0) has become an important outcome assessment to capture user satisfaction in the field of assistive technology. The purpose of this study is to investigate the psychometric properties of the Chinese version of the QUEST 2.0 (C-QUEST) in terms of content and substantive and factor validity and to explore its applicability on user satisfaction on mobility and equipment among Chinese people with spinal cord injury. A group of six expert members were invited to evaluate the content validity and translation quality of the 12-item C-QUEST. The revised version, along with the brief version of the World Health Organization Quality of Life Questionnaire (WHOQOL-BREF [HK]), was administered on user satisfaction of people with spinal cord injury in the community. The content validity and item performance were evaluated to be satisfactory. Exploratory factor analysis with varimax rotation agreed with the bidimensional structure of Device and Services in the construct of user satisfaction (61.06% variance explained). Items in WHOQOL-BREF (HK) were shown to have positive and moderate correlations with C-QUEST Device items (r = .412-.567, p < .05) but no significant associations with the Services items (p > .05). The 12-item C-QUEST was shown to be a valid and relevant instrument to capture the user satisfaction among Chinese people with spinal cord injury in the context of mobility and seating equipment.

Adult↗

Development of a nucleoside analog UV light sensor.

Conjugation of the photosensitive nucleoside (E)-5-(2-methoxycarbonylethenyl)cytidine to biotin provided a means to attach this analogue to microparticles for dosimetry applications that require UV sensor mobility.

Biosensing Techniques↗

Using personal digital assistants to access drug information.

The use of personal digital assistants (PDAs) to access drug information in a health system is described. Given the widespread use of PDAs at an 872-bed university health system, an opportunity existed to provide current drug information to physicians via these devices. As part of the health system's intranet, extensive online content had been made available through a browser; extension to PDAs was a natural next step. There were two primary requirements: the ability to synchronize information with the database server when a PDA was used and the development of content and applications by using existing staff. Mobile enterprise software was chosen that supports multiple PDA platforms, is easy to use, and does not require programming skills. The software works through customized "channels," or collections of information from a content provider. The customized channel service works over the Internet. Two channels of content were created, an ambulatory care channel and an inpatient care channel. The ambulatory care channel contains a list of preferred ambulatory care agents, poison control information, the locations of outpatient pharmacies, drug information, and safety tips for prescribing. The inpatient channel contains the inpatient formulary, current news and events, information on currrent drug shortages and recalls, pharmacy contact information, and medication safety tips. When a user synchronizes his or her PDA, the software contacts the department's intranet servers and processes the request. The data are compressed and downloaded to the user's PDA. A university health system successfully used PDAs to access drug and other information.

Clinical Pharmacy Information Systems↗

Postoperative thoracotomy. Effect of transcutaneous electrical nerve stimulation on forced vital capacity.

The purpose of this study was to measure the effects of transcutaneous electrical nerve stimulation on patients who had undergone thoracotomies, using the objective physiological measurement of forced vital capacity. Twenty-one patients were randomly assigned to an experimental group (n = 11) or a control group (n = 10). Each group performed three trials of forced vital capacity testing over a 20-minute period. In addition, the experimental group was given a 10-minute treatment of transcutaneous electrical nerve stimulation at the sites of greatest pain. The data indicated a statistically significant increase in forced vital capacity during the stimulation (p less than .01), suggesting that transcutaneous electrical nerve stimulation during application improves chest expansion and mobility in patients who have had thoracotomies.

Adolescent↗

Clinical measurements to assess cardiopulmonary function.

Physical therapists perform measurements of the cardiovascular and pulmonary systems that are used to generate exercise prescriptions and to assess the effects of treatment interventions. The purpose of this article is to describe methods that are used routinely in clinical settings to evaluate heart rate, blood pressure, breathing patterns, respiratory muscle strength, chest mobility, and breath sounds. The application of subjective ratings performed by patients is discussed. In the interpretation of results of measurements, clinicians should consider both biological and technical sources of variability. Research studies are needed to establish both intrarater and interrater reliability of many of these measurements used in physical therapy practice.

Blood Pressure Determination↗

Mechanics of the external fixation test in the lumbar spine. A roentgen stereophotogrammetric analysis.

STUDY DESIGN: By implanting tantalum indicators percutaneously during application of pedicular screws, lumbosacral mobility could be studied with roentgen stereophotogrammetric analysis in seven patients having a diagnostic external fixation test. OBJECTIVES: To determine the mechanical effects on the segmental mobility during an external fixation test of the lumbar spine. SUMMARY OF BACKGROUND DATA: External pedicular fixation test of the lumbar spine has been reported a valuable prognostic instrument in fusion for low back pain. METHODS: A Magerl external fixation device was applied in seven patients with low-grade spondylolysis-olisthesis. By using roentgen stereophotogrammetric technique, the intervertebral translations in the lumbosacral segment were determined. Each patient had three separate examinations; with the frame fixed, with the frame loosened, and without frame 6 weeks after screw removal. RESULTS: With the external frame fixed, the sagittal intervertebral translations were significantly reduced, in three cases to a level beneath the accuracy of the measuring method. One patient had the same immobilizing effect even with the frame loosened while for the others loosening of the frame meant regained mobility of the segment. CONCLUSION: The properties of the external fixator give an adequate mechanical basis for the prognostic external fixation test in lumbar fusion.

Adult↗