PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “RADIO WAVES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Exposure limits for ultra-short wave radiation in work environments.

Exposure limit values for ultra-short wave radiation of humans were derived on the basis of epidemiological survey and experimental exposure of rabbits. Eighteen male rabbits were divided into 4 groups randomly. Three groups were irradiated with ultra-short waves (100 MHz) at 35, 1.5-3.5, and 0.07 mW/cm2 power density in an E-polarized TEM Cell at 24 +/- 4 degrees C ambient temperature. The last group in a sham chamber served as controls. Irradiation was performed 3 hours per day, 5 days per week for 24 weeks. Thermal effects occurred in the group irradiated at 35 mW/cm2. The thermal threshold limit value was set at 1.5 mW/cm2. An epidemiological survey was carried out on 136 factory workers and TV operators exposed over one year to ultra-short wave radiation at 0.2 mW/cm2. They were compared with 108 controls. The only complaint of the exposed group was neurosis. The exposure limit value (ELV) to short wave radiation was set at 0.2 mW/cm2 by using a 15- and 20-fold safety factor.

Animals↗

Repolarization abnormalities after catheter ablation of accessory atrioventricular connections with radiofrequency current.

The purpose of this study was to evaluate the serial changes in T wave configuration in patients undergoing successful radiofrequency catheter ablation of accessory atrioventricular (AV) connections. Twenty-nine consecutive patients with overt preexcitation and 16 patients with a concealed accessory atrioventricular (AV) connection were included. An electrocardiogram (ECG) was recorded before ablation and 15 min, 1 or 2 days and 1 and 3 months after ablation. Postablation T wave abnormalities occurred in 22 (76%) of the 29 patients who had overt pre-excitation but in none of the 16 patients with a concealed accessory AV connection. The T wave abnormalities were not related to myocardial necrosis or echocardiographic abnormalities. The ECG location and severity of T wave changes were dependent on the accessory AV connection location and degree of baseline pre-excitation, respectively. Fourteen of 19 patients with a posteriorly located AV connection (left, right or septal) had T wave inversion or flattening in the inferior leads and 3 patients had precordial T wave peaking. Two patients with an anteroseptal AV accessory connection had both inferior T wave inversion or flattening and precordial T wave peaking. Among seven patients with a manifest left lateral accessory AV connection, two had lateral T wave inversion or flattening and two had precordial T wave peaking. There was 95% concordance between the directional change of the T wave after ablation and the direction of the delta wave on the baseline ECG.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[GSM 1,800 MHz radiofrequency electromagnetic fields induced clustering of membrane surface receptors and interference by noise magnetic fields].

OBJECTIVE: To investigate the possible effect of exposure to GSM 1,800 MHz radiofrequency electromagnetic fields (RF EMF) on epidermal growth factor (EGF) receptor and its possible interference by noise magnetic fields (MF). METHODS: Chinese hamster lung fibroblasts (CHL) were exposed to 1,800 MHz RF EMF (modulated by 217 Hz or 50 Hz, or unmodulated), 2 microT noise MF, and RF EMF combined with 2 microT noise MF for 15 min, respectively. The specific absorption rates (SARs) of RF EMF were 0.1, 0.5, 1.0, 2.0 and 4.0 W/kg. Commercial EGF (1 ng/ml) treatment was used as positive control. EGF receptors on the cell membrane were observed under a laser scanning confocal microscope after indirect immunofluorescence staining. RESULTS: EGF receptor clustering was induced after exposure to GSM 1,800 MHz RF EMF modulated by 217 Hz or 50 Hz MF at SARs of 0.5, 1.0, 2.0, 4.0 W/kg for 15 min as induced by 1 ng/ml EGF, but not at SAR of 0.1 W/kg. And no EGF receptor clustering was found in cells after exposure to unmodulated RF EMF or 2 microT noise MF. In addition, superposition of 2 microT noise MF could inhibit the EGF receptor clustering induced by GSM 1,800 MHz RF EMF. CONCLUSION: EGF receptor clustering in CHL cells can be induced by GSM 1,800 MHz RF EMF at the lowest SAR of 0.5 W/kg and inhibited by noise MF. The modulation of wave may play an important role in the inducement of receptor clustering after RF exposure.

Animals↗

A novel method for estimating the focal size of two confocal high-intensity focused ultrasound transducers.

Estimating the focal size and position of a high-intensity focused ultrasound (HIFU) transducer remains a challenge since traditional methods, such as hydrophone scanning or schlieren imaging, cannot tolerate high pressures, are directional, or provide low resolution. The difficulties increase when dealing with the complex beam pattern of a multielement HIFU transducer array, e.g., two transducers facing each other. In the present study we show a novel approach to the visualization of the HIFU focus by using shockwave-generated bubbles and a diagnostic B-mode scanner. Bubbles were generated and pushed by shock waves toward the HIFU beam, and were trapped in its pressure valleys. These trapped bubbles moved along the pressure valleys and thereby delineated the shape and size of the HIFU beam. The main and sidelobes of 1.1- and 3.5 MHz HIFU beams were clearly visible, and could be measured with a millimeter resolution. The combined foci could also be visualized by observing the generation of sustained inertial cavitation and enhanced scattering. The results of this study further demonstrate the possibility of reducing the inertial cavitation threshold by the local introduction of shock wave-generated bubbles, which might be useful when bubble generation and cavitation-related bioeffects are intended within a small region in vivo.

Equipment Design↗

Spontaneous and nitrosourea-induced primary tumors of the central nervous system in Fischer 344 rats exposed to frequency-modulated microwave fields.

In a 2-year bioassay, we exposed Fischer 344 rats to a frequency-modulated (FM) signal (836.55 MHz +/- 12.5 KHz deviation) simulating radiofrequency exposures in the head of users of hand-held mobile phones. We tested for effects on spontaneous tumorigenicity of central nervous system (CNS) tumors in the offspring of pregnant rats and also for modified incidence of primary CNS tumors in rats treated with a single dose of the neurocarcinogen ethylnitrosourea (ENU) in utero. ENU dosage (4 mg/kg) was selected to give an expected brain tumor incidence of 10-15% over the mean life span of 26 months. Pregnant dams (n = 102) were randomly assigned to six groups. Their offspring were treated as cohorts in each of the six groups (n = 90 per group; total, n = 540): Sham ENU/Sham Field, Sham ENU/Field Exposed, ENU/Sham Field, ENU/Field Exposed, ENU/Cage Control, and Sham ENU/Cage Control. Intermittent field exposures began on gestation day 19 and continued until weaning at 21 days, resuming thereafter at 31 days and continuing until experiment termination at 731-734 days. Energy absorption rates (SARs) in the rats' brains were similar to localized peak brain exposures of a phone user (female, 236 g, 1.0 W/kg; male, 450 g, 1.2 W/kg). Of the original 540 rats, 168 died before the termination of the experiment. In these rats, ENU significantly reduced survival from a mean of 708 days in three groups without ENU treatment to 645 days in three groups treated with ENU (P < 0.0005). There were no effects on survival attributable to FM field exposure in either ENU-treated or in sham-treated groups. Spontaneous CNS tumor incidence in control groups was 1.1-4.4% but sharply higher in rats receiving ENU (14.4-22.2%; P < 0.0001). No FM field-mediated changes were observed in number, incidence, or histological type of either spontaneous or ENU-induced brain tumors, nor were gender differences detected in tumor numbers. These negative findings with FM fields contrast with our study using standard digital phone fields pulsed on and off at 50/se, where a trend was noted toward reduced incidence of both spontaneous and ENU-induced CNS tumors (W. R. Adey et al., Radiat. Res., 152: 293-302, 1999). Although consistent but not attaining significance in the experiment overall (spontaneous CNS tumors, P < 0.08 one-tailed; P < 0.16 two-tailed; ENU-induced CNS tumors, P < 0.08 one-tailed, P < 0.16 two-tailed), the trend was significant (P < 0.015 one-tailed, P < 0.03, two-tailed) in rats that received ENU and died prior to experiment termination, with a primary brain tumor as the cause of death. We discuss differences in the signaling structure of digital and FM fields. Certain bioeffects induced by either amplitude-modulated or pulsed radiofrequency fields at athermal levels have not been seen with fields of similar average power but unvarying in intensity (continuous wave or frequency-modulated fields).

Animals↗

[Diagnostic thermoradiolocation in neurosurgery].

From the examination of 915 patients with neurosurgical pathology the authors showed the possibility of mediated thermoimaging of localized lesions in the brain, spinal cord, and peripheral nerves. The combination of local and distant thermoasymmetries which are realized through reflex mechanisms of vegetovascular innervation is a characteristic feature of the thermovision syndromes in the infrared wave bands. It was proved experimentally and clinically that radiothermometry in the millimeter and centimeter wave bands yields information on the temperature of the surface and deep-seated cerebral tissues through the hairs on the head.

Brain Injuries↗

Simple RF matching circuit for conversion of electrosurgical units or laboratory amplifiers to hyperthermia treatment devices.

An inexpensive combination RF matching network and power meter circuit is described for matching a broad range of load impedances to an arbitrary source impedance and providing accurate indication of net real power delivered to the load. A schematic is included with component values calculated for an operating frequency of 500 kHz. Specific design equations are given to facilitate frequency or impedance scaling. While general in nature, the matchbox design is intended for safe use with any generator capable of 100-250 W of continuous wave power at an operating frequency between 0.1-10 MHz for inducing localized hyperthermia of biological tissues. Capacitively or resistively coupled RF current heating then may be accomplished using a wide variety of electrode configurations, depending only on tumor geometry and not on matching considerations.

Amplifiers, Electronic↗

Pilot experiments on temperature cycling in rats exposed repetitively to radiofrequency radiation (RFR).

A series of temperature cycling experiments during Radiofrequency Radiation (RFR) exposure of rats was performed. It is evident that this type of exposure procedure permits the introduction of high doses of electromagnetic energy into biological systems while the systems are maintained at physiologically acceptable temperatures. Experiments were carried out at various power densities (50-200 mW/cm2) using continuous wave (CW) and pulsed radiation while the carrier frequency was maintained at 2.06 GHz. It was observed that single-day RFR exposures at power levels used in this series produced no observable effect on temperature regulation of rats in terms of heat dissipation efficiency.

Animals↗

Further studies of human whole-body radiofrequency absorption rates.

Further studies of human whole-body radiofrequency (RF) absorption rates were carried out using a TEM-cell exposure system. Experiments were done at one frequency near the grounded resonance frequency (approximately 40 MHz), and at several below-resonance frequencies. Absorption rates are small for the K and H orientations of the body, even when grounded. For the body trunk in an E orientation, the absorption rate of a sitting person is about half of the rate for the same person standing with arms at the sides; the latter in turn is about half the rate for the same subject standing with arms over the head. Two-body interactions cause no increase in absorption rates for grounded people. They do, however, increase the absorption rates for subjects in an E orientation in free space; the largest interaction occurs when one subject is lambda/2 behind the other (as seen by the incident wave). When these results are applied to practical occupational exposure situations, the whole-body specific absorption rate does not exceed the ANSI limit of 0.4 W/kg for exposures permitted by the ANSI standard (C95.1-1982) at frequencies from 7 to 40 MHz.

Adult↗

[Effect of decimeter waves on the functional status of spinal alpha-motor neurons in patients with neurologic syndromes of lumbar osteochondrosis].

Patients with neurological syndromes of lumbar osteochondrosis were subjected to clinico-electromyographic examination to study whether it is possible to regulate the function of spinal alpha-motoneurons by decimetric waves (DMW). The effect of DMW on the excitability of alpha-motoneurons was found to depend on their initial function. The neurophysiological mechanisms underlying the therapeutic action of DMW in this pathology are analyzed.

Adult↗

Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

PURPOSE: To investigate the effects of high dielectric material padding on RF field distribution in the human head at 7.0 T, and demonstrate the feasibility and effectiveness of RF passive shimming and focusing with such an approach. MATERIALS AND METHODS: The intensity distribution changes of gradient-recalled-echo (GRE) and spin-echo (SE) images of a human head acquired with water pads (dielectric constant = 78) placed in specified configurations around the head at 7.0 T were evaluated and compared with computer simulation results using the finite difference time domain (FDTD) method. The contributions to the B(1) field distribution change from the displacement current and conductive current of a given configuration of dielectric padding were determined with computer simulations. RESULTS: MR image intensity distribution in the human head with an RF coil at 7.0 T can be changed drastically by placing water pads around the head. Computer simulations reveal that the high permittivity of water pads results in a strong displacement current that enhances image intensity in the nearby region and alters the intensity distribution of the entire brain. CONCLUSION: The image intensity distribution in the human head at ultra-high field strengths can be effectively manipulated with high permittivity padding. Utilizing this effect, the B(1) field inside the human head of a given RF coil can be adjusted to reduce the B(1) field inhomogeneity artifact associated with the wave behavior (RF passive shimming) or to locally enhance the signal-to-noise ratio (SNR) in targeted regions of interest (ROIs; RF field focusing).

Brain↗

An improved approximation for the Rayleigh wave equation.

We derive a simple expression, which gives an approximate value of the Rayleigh wave velocity in an isotropic solid. This approximation is five times better than that given by Viktorov. The velocity equation can be easily inverted in order to obtain an accurate determination of the elastic constants. This procedure can be worthwhile for elastic microanalysis of bulk materials by scanning acoustic microscopy.

Models, Theoretical↗

Performance and use of current sheet antennae for RF-hyperthermia of a phantom monitored by 3 tesla MR-thermography.

Several MR-compatible current sheet antennae (CSA) of different height (h) (16 cm (l) x 8 cm (w) x 1-5 cm (h)) were built for simulated RF (96 MHz) hyperthermia of a medium-sized (12l) tissue-equivalent phantom inside a 3 tesla whole body tomograph. Prior to use, efficiencies of the CSA were determined by network analysis and by calorimetry. Depending on the height h of the CSA and on the thickness d(bolus) of the water bolus used for RF-coupling of the CSA to the lossy medium, their efficiency varied between 20-70% and the CSA with h = 3 cm was selected for simulated RF hyperthermia. During heating, spatial temperature distributions (20-42 degrees C) of five slices (voxel size 2 x 2 x 10mm(3)) were recorded intermittently within 4 s/slice by measuring the temperature dependent shift of the (1)H resonance frequency (125.32 MHz). A phased array consisting of two identical CSA produced distinctly different spatial temperature distributions at 0 and 180 degrees phase difference between both RF channels feeding the antennae. Within a one-dimensional heat diffusion model, the specific absorption rate (SAR) of the electromagnetic wave generated by a single antenna was deduced from the experimental data resulting in a penetration depth (1/e(2)) of approximately 4 cm.

Biophysical Phenomena↗

High frequency SAW devices based on third harmonic generation.

We demonstrate the third harmonic generation in a ZnO/Si layered structure to obtain high frequency SAW devices. This configuration eliminates the need of high lithography resolution and allows easy integration of such devices and electronics on the same wafer. A theoretical study was carried out for the determination of the phase velocity and the electromechanical coupling coefficient (K(2)) dispersion curves of the surface acoustic waves. These results are also in agreement with those measured on a SAW filter designed for the third harmonic generation and the operating frequency is up to 2468 MHz.

Acoustics↗

Generator study of brainstem auditory evoked potentials by a radiofrequency lesion method in rats.

The generators of brainstem auditory evoked potentials (BAEPs) in rats were investigated experimentally. Discrete lesions of the brainstem auditory pathway were made unilaterally using a stereotaxic radiofrequency coagulation method, and the BAEPs were recorded before and after the lesions to observe the alterations. The waves of the BAEPs were affected by the lesions as follows: (1) all of the BAEP waves were attenuated or eliminated by a lesion of the auditory nerve; (2) wave II was abolished or attenuated in amplitude following a lesion of the cochlear nucleus; (3) marked reduction or abolition of wave III occurred with some effect on waves IV and V following lesions of the superior olivary complex; (4) the following trough in the wave III was significantly attenuated by lesions of the lateral lemniscus that were associated with inconsistent changes in waves IV and V; (5) no waves were affected significantly by a lesion of the inferior colliculus. The method of radiofrequency lesion using stereotaxic localization proved to be a simpler and more rapid procedure for determining the generators of BAEPs in animals than other surgical lesion methods.

Animals↗

Electroretinography of short-wavelength-sensitive cones with a LED built-in electrode and its normal values.

To record electroretinograms (ERG) produced by short-wavelength-sensitive cone mechanisms (SWS-cone ERG), the authors used three kinds (blue, green, and red) of light-emitting diode (LED) which were built into a contact lens electrode assembly. The LEDs were used as both stimulus and background light sources. ERG was recorded using blue LED after 10 min of yellow light adaptation produced by green and red LEDs. Duration of photo-stimulation was either 2 or 100 ms. ERG recorded in normal human subjects showed two positive waves with 2 ms photo-stimulation. Amplitude of the former positive wave (b1-wave) was attenuated when the luminance of yellow background increased, and the latter positive wave (b2-wave) was attenuated when the color of photo-stimulation was green or red. These findings suggest that middle-wavelength-sensitive and long-wavelength-sensitive cone mechanisms generated the former positive wave (b1-wave) and SWS-cone mechanisms generated the latter positive wave (b2-wave). Ratio of b2-wave-amplitude to b1-wave-amplitude with 2 ms photo-stimulation measured on 39 normal subjects ranged from 0.5 to 2.0. It was concluded that this three-colored LED built-in electrode was useful for recording SWS-cone ERG.

Adolescent↗

Epineurial capping via Surgitron and the reduction of stump neuromas in the rat.

Stump neuromas and recurrent neuromas are common problems following amputation and neuroma excision, respectively. Epineurial capping by microsuture has been shown to be somewhat effective in the reduction of the size of stump neuromas and in their confinement away from a weightbearing area. The present study shows that epineurial capping by coagulation of the epineurium with a radiofrequency wave Surgitron forms an effective seal around the proximal stumps of severed axons in rats. This seal effectively reduced axon proliferation but did not completely inhibit neuroma formation. Removal of the distal stump did not significantly affect neuroma formation in the proximal stump.

Amputation Stumps↗