PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens.

A current review of the application of solid-phase microextraction (SPME) to the analysis of ignitable liquids and explosive residues is presented along with experimental results demonstrating the relative effects of controllable variables. Variables discussed include fiber chemistry, adsorption and desorption temperatures, extraction and desorption times, fiber sampling placement (direct, headspace, and partial headspace) and matrix effects, including water content. SPME is shown to be an inexpensive, rapid and sensitive method for the analysis of ignitable liquids and high explosives residues from solid debris samples and from aqueous samples. Explosives are readily detected at parts per trillion concentrations and ignitable liquids are reproducibly detected at levels below those using conventional methods.

Chemistry Techniques, Analytical↗

[Preparation of a solid-phase microextraction fiber coated with gamma-Al2O3 and determination of volatile organic compounds in aqueous and gaseous samples].

A method for the preparation of a novel gamma-Al2O3 coated layer on fibers for solid-phase microextraction (SPME) was developed. The adsorption and desorption properties of the coated fibers were studied by the extraction of some volatile organic compounds such as benzene, toluene, ethylbenzene and xylene isomers (BTEXs) from aqueous samples. The calibration graphs were linear in the range 0.01 mg/L to 3 mg/L and the detection limits for BTEX compounds were between 1 microg/L and 10 microg/L. Also the gamma-Al2O3 coated fibers exhibited a good thermal stability (to 350 degrees C ) and reproducibility with relative standard deviation of 8.3%. It can be used to determine organic compounds in the real gaseous samples.

Aluminum Oxide↗

Electrochemical solid-phase microextraction of anions and cations using polypyrrole coatings and an integrated three-electrode device.

A method for the extraction, transfer and desorption of anions and cations under controlled potential conditions employing a new integrated three-electrode device is described. The device, containing working, reference and counter electrodes, was prepared from tubes that could be moved vertically with respect to each other. In this way, a small amount of solvent, held by capillary force, remained between the electrodes when the device was lifted out of a solution after an extraction. This design allowed the potential control to be maintained at all times. With the new integrated device, it was possible to perform potential controlled desorption into vials containing as little as 200 microl of solution. The required ion exchange capacity was obtained by electrodeposition of a polypyrrole coating on the surface of the glassy carbon working electrode. Solid-phase microextractions of several cations or anions were performed simultaneously under potentiostatic control by doping the polypyrrole coating with different anions such as perchlorate and p-toluenesulfonate. The efficiency of the extractions, which could be altered by varying the potential of the working electrode, could be increased by 150 to 200% compared to extractions using normal solid-phase microextraction conditions under open circuit conditions. A constant potential of +1.0 V and -0.5 V with respect to the silver pseudo reference electrode, was found to be well-suited for the extraction of samples containing ppm concentrations of anions (chloride, nitrite, bromide, nitrate, sulfate and phosphate) and cations (cadmium, cobalt and zinc), respectively.

Journal Article↗

Combining solid-phase microextraction and on-line preconcentration-capillary electrophoresis for sensitive analysis of pesticides in foods.

The combined use of solid-phase microextraction (SPME) and different on-line preconcentration strategies for ultrasensitive capillary electrophoresis-ultraviolet (CE-UV) analysis of five pesticides in a single run is investigated. Normal stacking mode (NSM), field-enhanced sample injection (FESI), and stacking with matrix removal (SWMR) are explored to increase the sensitivity of the CE-UV analysis of a selected group of pesticides (cyprodinil, cyromazine, pyrifenox, pirimicarb, and pyrimethanil). It could be observed that reverse polarity-stacking with matrix removal (RP-SWMR) provided the best results in terms of sensitivity (enhancement was up to 272-fold compared with normal injection). The separation buffer consisted of 0.4 mM cetyltrimethylammonium chloride (CTAC), 0.4 M acetic acid at pH 4 containing 5% v / v 2-propanol. This approach was then combined with SPME to determine the pesticides in water, apple, and orange juice. The combination of both preconcentration procedures allowed the determination of these pesticides at concentrations down to 2.5 microg / L in water and 3.1 microg / L in juices (i.e., levels well below the maximum residue limits allowed for these compounds). To our knowledge, this is the first report showing the great possibilities of the combined use of SPME, on-line sample preconcentration, and CE for pesticide analysis.

Carbamates↗

Headspace solid phase microextraction for screening for the presence of resins in Egyptian archaeological samples.

The aim of this study was to use headspace solid phase microextraction (SPME) to reveal the presence of resin in archaeological samples, such as mummification balms, from ancient Egypt. Experiments were first performed with fresh resins of known origin. The SPME fibre readily extracted mono- and sesquiterpenes and, to a lesser extent, diterpenes. Using mass spectra and retention indices of constitutive compounds, qualitative analysis of the volatile fraction allowed us to differentiate resins or gum-resins such as myrrh, olibanum, galbanum, labdanum, mastic, and conifer resins. SPME was then successfully applied to archaeological samples from ancient Egypt in which the presence of resins was detected. Volatile components were desorbed and trapped according to the same SPME procedure as was applied to fresh resins, after a sample preparation consisting of a fine grinding.

Journal Article↗

Optimisation of solid-phase microextraction coupled to HPLC-UV for the determination of organochlorine pesticides and their metabolites in environmental liquid samples.

A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-mum polydimethylsiloxane-divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-mum PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.

Chromatography, High Pressure Liquid↗

Surface characterization of commercial fibers for solid-phase microextraction and related problems in their application.

The surfaces of commercially available polydimethylsiloxane (PDMS) and Carboxen-PDMS fibers for solid-phase microextraction (SPME) were investigated by optical and electron microscopy. Damage to the coating as well as contamination of new fibers and a highly variable number of pores in Carboxen-PDMS coatings were observed. Together with the contamination of the fibers during their use with metallic particles originating from the SPME fiber holder they are possible explanations for the problems encountered in the analysis of organolead, organotin and organosulfur compounds, such as artifact formation and low repeatability.

Journal Article↗

Application of solid-phase microextraction in the investigation of protein binding of pharmaceuticals.

Protein-drug interactions of seven common pharmaceuticals were studied using solid-phase microextraction (SPME). SPME can be used in such investigations on the condition that no analyte depletion occurs. In multi-compartment systems (e.g. a proteinaceous matrix) only the free portion of the analyte is able to partition into the SPME fiber. In addition if no sample depletion occurs, the bound drug-free drug equilibria are not disturbed. In the present study seven pharmaceuticals (quinine, quinidine, naproxen, ciprofloxacin, haloperidol, paclitaxel and nortriptyline) were assayed by SPME. For quantitative purposes SPME was validated first in the absence of proteins. Calibration curves were constructed for each drug by HPLC-fluorescence and HPLC-UV analysis. SPME was combined to HPLC off-line, desorption occurring in HPLC inserts filled with 200 microL methanol. Binding of each drug to human serum albumin was studied independently. Experimental results were in agreement with literature data and ultrafiltration experiments, indicating the feasibility of the method for such bioanalytical purposes.

Binding, Competitive↗

Determination of dichlorvos by on-line microwave-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-electron-capture detection.

The pretreatment technique of microwave-assisted extraction on-line headspace solid-phase microextraction (MAE-HS-SPME) was designed and studied for one-step in-situ sample preparation prior to the chromatographic analysis of a pesticide on vegetables. The pesticide on chopped vegetables was extracted into an aqueous solution with the aid of microwave irradiation and then directly onto the SPME fiber in headspace. After being collected on to the SPME fiber and desorbed in the GC injection port, the pesticide (dichlorvos) was analyzed with a GC-electron-capture detection system. The optimum conditions for obtaining extraction efficiency, such as the pH, the polarity modifier, and the salt added in sample solution, the microwave irradiation, as well as the desorption parameters were investigated. Experimental results indicated that the proposed MAE-HS-SPME technique attained the best extraction efficiency of 106% recovery under the optimized conditions, i.e. irradiation of extraction solution (10% aqueous ethylene glycol) at pH 5.0 with medium microwave power for 10 min. Desorption at 220 degrees C for 3 min offered the best detection result. The detection was linear at 5-75 microg/l with correlation coefficient of 0.9985. Detection limit was obtained at approximately 1.0 microg/l level based on S/N=3. The proposed method provided a very simple, fast, and solvent-less procedure to collect pesticides directly from vegetables for GC determination. Its application was illustrated by the analysis of trace dichlorvos in vegetables.

Chromatography, Gas↗

Optimisation of a solid-phase microextraction procedure for the determination of triazines in water with gas chromatography-mass spectrometry detection.

A procedure based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry, operating in the chemical ionisation mode, was developed and optimised in order to determine 10 triazines in water samples. Five different SPME fibers available for analysis [polydimethylsiloxane (PDMS) 100 microm, polyacrylate (PA) 80 microm, PDMS-divinylbenzene (DVB) 65 microm, Carbowax (CW)-DVB 65 microm, and Carboxen (CAR)-PDMS 75 microm] were tested, and PDMS-DVB was selected. To enhance the sensitivity of the SPME, variables affecting adsorption and desorption steps such as temperature, time, pH and ionic strength of the solution were optimised. Detection limits obtained were ranged between 2 and 17 ng l(-1), and precision values were below 8% for the selected PDMS-DVB fiber. The optimised method was applied to real water samples and no triazines were detected.

Gas Chromatography-Mass Spectrometry↗

Role of solid-phase microextraction in the identification of highly volatile pheromones of two Rhinoceros beetles Scapanes australis and Strategus aloeus (Coleoptera, Scarabaeidae, Dynastinae).

Solid-phase microextraction (SPME) samplings from live insects or natural secretion allowed one to identify the aggregation pheromones of the pest beetles Scapanes australis and Strategus aloeus by efficient and rapid isolation of their highly volatile (72 < M(r) < 116) components. S. australis male pheromone was identified as a 84:12:4 (w/w) mixture of 2-butanol [67:33 (R)-(-):(S)-(+) ratio], 3-hydroxy-2-butanone and 2,3-butanediol [43:17:40 (R,R)-(-):(S,S)-(+):meso ratio], and S. aloeus pheromone as a 95.5:4.0:0.5 (w/w) mixture of 2-butanone, 3-pentanone and sec.-butyl acetate by GC-MS using conventional and chiral capillary columns. This is the first report of Scarabaeidae pheromones based on such small and common molecules.

Animals↗

Determination of distribution coefficients of priority polycyclic aromatic hydrocarbons using solid-phase microextraction

The determination of distribution coefficients is important for prediction of the chemical pathways of organic compounds in the environment. Solid-phase microextraction (SPME) is a convenient and effective method to measure the distribution of chemicals in a two-phase system. In the present study, the SPME distribution coefficient (K(spme)) of 16 priority aromatic hydrocarbons (PAHs) was determined with 100-microm poly(dimethylsiloxane) (PDMS) and 85-microm polyacrylate (PA) fibers. The partition coefficients and LeBas molar volumes were used to describe the linearity of the log K(spme) values of PAHs. Also, the validation of the distribution coefficient was examined using different sample volumes. The extraction time was dependent on the types of PAHs, and 20 min to 60 h was needed to reach equilibrium. The determined log K(spme) values ranged from 3.02 to 5.69 and from 3.37 to 5.62 for 100-microm PDMS and 85-microm PA fibers, respectively. Higher K(spme) values of low-ring PAHs were observed using 85-microm PA fiber. Good linear relationships between log K(ow) and log K(spme) for PAHs from naphthalene to benzo[alpha]pyrene and from naphthalene to chrysene for 100-microm PDMS and 85-microm PA fibers, respectively, were obtained. The correlation coefficients were 0.969 and 0.967, respectively. The linear relationship between log K(spme) and the LeBas molar volume was only up to benz[alpha]anthracene for 85-microm PA fiber and up to chrysene for 100-microm PDMS fiber. Moreover, the effect of sample volume can be predicted using the partition coefficient theory and excellent agreement was obtained between the experimental and theoretical absorbed amounts of low-ring PAHs. This result shows that the determined log K(spme) is more accurate than the previous method for estimating analytes with log K(ow) < 6 as well as for predicting the partitioning behaviors between SPME fiber and water.

Journal Article↗

In-tube solid-phase microextraction coupled to capillary LC for carbamate analysis in water samples.

Recently, the on-line sample preparation technique, intube solid-phase microextraction (SPME), was successfully implemented with a Hewlett-Packard 1100 HPLC system for analysis of carbamates in water samples. This paper describes the coupling of in-tube SPME to capillary LC and explores its utility as a sample preparation method in that format, relative to conventional LC. The Hewlett-Packard HPLC system was upgraded to a capillary LC system using commercially available accessories from LC Packings. The combination of in-tube SPME with a capillary LC system was expected to build on the merits of both in-tube SPME and the capillary LC to generate a sensitive method with an easy, effective, and efficient sample preparation. Due to the relatively large effective injection volume of the in-tube SPME technique (30-45 microL), on-column focusing was employed in order to achieve good chromatographic efficiency. Excellent sensitivity was achieved with very good method precision. For all carbamates studied, the RSD of retention time was between 0.5 and 0.8% under 4 microL/min microgradient conditions. The RSD of peak area counts was between 1.5 and 4.6%. The detection limits for all carbamates studied were less than 0.3 microg/L and, for carbaryl, just 0.02 microg/L (20 ppt). Compared with the conventional in-tube SPME/LC method, the LODs were lowered for carbaryl, propham, methiocarb, promecarb, chlorpropham, and barban, by factors of 24, 45, 42, 81, 62, and 56, respectively. The optimized method was successfully applied to the analysis of carbamates in surface water samples.

Carbamates↗

Solid phase microextraction (SPME) of orange juice flavor: odor representativeness by direct gas chromatography olfactometry (D-GC-O).

The sensorial quality of solid phase microextraction (SPME) flavor extracts from orange juice was measured by direct gas chromatogrphy-olfactometry (D-GC-O), a novel instrumental tool for evaluating odors from headspace extracts. In general, odor impressions emerging from SPME extracts poorly resembled that of the original orange juice. In an attempt to improve the sensorial quality of extracts, sample equilibration and exposure times were varied on Carboxen/polydimethylsiloxane (CAR/PDMS) and divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibers. Best sensorial results were obtained with the DVB/CAR/PDMS fiber exposed for the shortest time; a trained panel of eight assessors judged its odor as the most representative of the reference orange juice. The analysis of odor active compounds by classical GC-O accounted for odor characteristics revealed by D-GC-O. A principal component analysis (PCA) was applied on SPME and headspace extracts using flavor recoveries as variables. Interestingly, PCA discriminated samples according to their odor representations described by D-GC-O analysis. This paper provides the first comprehensive methodology to "smell" SPME extracts and "evaluate" their sensorial quality. This method will enable future investigations to further improve SPME performance.

Beverages↗

Detection of tricyclic antidepressants in whole blood by headspace solid-phase microextraction and capillary gas chromatography.

A simple method for the extraction of four tricyclic antidepressants from whole blood by headspace solid-phase microextraction (SPME) is presented. The whole blood samples contain four drugs (amitriptyline, chlorimipramine, imipramine, and trimipramine) and are heated at 100 degrees C in a septum-capped vial in the presence of distilled water and NaOH solution; a polydimethylsiloxane-coated SPME fiber is exposed to the headspace of the vial to allow adsorption of the drugs before capillary gas chromatography (GC) with flame-ionization detection. The headspace SPME-GC produces intense peaks for each drug with very little background noise. Recoveries of the four drugs by the present method are 5.3-12.9%. The calibration curves for the drugs show linearity in the range of 31-1000 ng/0.5 mL. The detection limits of each drug are 16-25 ng/0.5 mL. Imipramine is detectable from rat blood 5 h after oral administration of imipramine (500 mg/kg body weight); the concentration is 1.44 +/- 0.209 micrograms/mL.

Amitriptyline↗

Fully automated determination of amphetamines and synthetic designer drugs in hair samples using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

This study describes a fully automated procedure using alkaline hydrolysis and headspace (HS) solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatographic (GC)-mass spectrometric (MS) detection of amphetamine, methamphetamine, methylendioxyamphetamine, methylendioxymethamphetamine, methylendioxyethylamphetamine, methylendioxyphenylbutanamine, and methylmethylendioxyphenylbutanamine in human hair samples. Ten milligrams of hair is washed with deionized water, petroleum ether, and dichloromethane. After the addition of deuterated internal standards the sample is hydrolyzed with sodium hydroxide and directly submitted to HS-SPME. After the absorption of analytes for an on-fiber derivatization procedure the fiber is directly placed into the HS of a second vial containing N-methyl-bis(trifluoroacetamide) before GC-MS analysis. The limits of detection are determined between 0.01 and 0.17 ng/mg. Absolute analyte recoveries are in the range between 0.3% and 7.5%. Linearity is proven over a range from 0.1 to 50 ng/mg with coefficients of correlation from 0.998 to 1. In comparison with conventional methods of hair analysis, this fully automated HS-SPME-GC-MS procedure is substantially faster and easier to perform without using solvents. It uses minimal sample amounts and has the same degree of sensitivity and reproducibility.

Amphetamines↗

Coating of solid-phase microextraction fibers with chemically bonded silica particles: selective extraction of polycyclic aromatic hydrocarbons from drinking water samples.

In this study, solid-phase microextraction fibers coated with modified silica particles (5 pm dp) bonded to methyl (C1), hexyl (C6), octyl (C8), and polymeric octadecyl (C18) groups are prepared and evaluated. Selective extraction of polycyclic aromatic hydrocarbons (PAHs) from river water is used to demonstrate the selective behavior of the fibers as a function of the alkyl chains bonded to the silica phase. Scanning electron micrography suggests that the coating structure consists in a monolayer of particles bonded to the surface of the fiber. The behavior of the fibers upon the extraction of PAHs from water samples is compared with the use of standard polydimethylsiloxane fibers that are commercially available.

Journal Article↗

Solid-phase microextraction for predicting the bioavailability of 2,4,6-trinitrotoluene and its primary transformation products in sediment and water.

Disposable solid-phase microextraction fibers (SPMEs) were used to measure the availability of 2,4,6-trinitrotoluene (TNT) and its two primary transformation products, 2-amino-4,6-dinitrotoluene (2ADNT) and 4-amino-2,6-dinitrotoluene (4ADNT). The SPMEs (85-microm polyacrylate) and sediment-dwelling oligochaetes (Tubifex tubifex) were exposed to TNT-spiked sediment, to TNT-spiked sediment amended with activated carbon, and to TNT-, 2ADNT-, and 4ADNT-spiked water. Sediment concentration was a poor predictor of bioavailability in unamended and carbon-amended sediments (r2 = 0.14-0.73) The activated carbon amendment reduced the bioavailability of compounds in carbon-amended sediment, causing the relationships between Tubifex concentrations and sediment concentrations to differ significantly between unamended and carbon-amended sediment for all compounds. In contrast, SPME TNT concentrations predicted Tubifex TNT concentrations (r2 = 0.54-0.79). and regression models did not differ significantly among the three TNT-spiked matrices. The SPME 2ADNT and 4ADNT concentrations also were predictive of Tubifex 2ADNT and 4ADNT concentrations (r2 = 0.44-0.90). Relationships between Tubifex concentrations and SPME concentrations were the same between unamended and carbon-amended TNT-spiked sediments for 2ADNT and 4ADNT; however, the relationship in sediment (pooled data) differed from the relationship found in 2ADNT- and 4-ADNT-spiked water. The SPMEs provided carbon amendment-independent measures of ADNT availability in sediment and matrix-independent measures of TNT availability among the three matrices. The SPMEs show promise for predicting bioavailable organic compounds in sediment and water.

Animals↗