PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “WASTES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Dry anaerobic digestion of differently sorted organic municipal solid waste: a full-scale experience.

This paper presents a comparison of dry anaerobic digestion reactors fed with differently sorted municipal organic solid wastes. One reactor was fed with source sorted organic wastes and a second reactor was fed with mixed organic wastes consisting of grey wastes, mechanically selected municipal solid wastes and sludge. The two reactors utilised the same process (Valorga) and operational conditions at full scale. The results of the study emphasise the influence of the kind of treated material on the process performances, especially in terms of biogas and methane production, thus, energy reclamation. The reactor treating the source sorted organic waste and the reactor treating the mixed organic wastes generated some 200 m3 and 60 m3 of biogas per ton of waste treated, respectively, while the specific methane production was some 0.40 and 0.13 m3CH4/kgTVS, respectively. The mass balance and the final fate of the digested material from the two reactors were also clearly different. As for the costs, these were some 29 Euro per ton of treated waste (50% for personnel) and 53 Euro/ton for disposing of the rejected materials. Incomes were some 100 Euro/ton (on average) and an other 15 Euro/ton came from green certificates. The initial investment was 16 million Euros.

Anaerobiosis↗

Dioxin emission factors for the incineration of different medical waste types.

Previous research works showed that to protect public health, hospital incinerators should be provided with equipment to reduce atmospheric emissions. Most hospital incinerators do not possess such equipment, so efficient methodologies should be developed to evaluate the safety of incineration procedures. Emission factors can be used for an easy estimation of the parameters defined in legislation. Nevertheless, the actual knowledge is very scarce, mainly because previously published emission factors do not include enough information about the incinerated waste types and the respective proportion in incinerated mixture. The existence of different waste classifications also reduces the usefulness of previously published results. This study reports the first dioxin emission factors estimated for the incineration of medical waste, segregated in different types according to the classification of the Portuguese legislation. The main purpose was to evaluate the influence of waste type on emission factors, assessing how useful they are if not associated to the composition of the incinerated mixture. The study also allowed analyzing the correspondence between different waste classifications that are being used, comparing the estimated emission factors with the sole results previously published for specific waste types but segregated according to a different classification. The influence of the incinerated waste type and segregation practices on the concentration and amount of emitted dioxin was assessed, as well as the influence of segregation practices on the amount of wastes that must be incinerated. To estimate eventual hazards for human health, dioxin concentrations in combustion gas flow were compared with the respective legal limits.

Air Pollutants↗

Vermicomposting of different types of waste using Eisenia foetida: a comparative study.

A study (100 days duration) was conducted to evaluate the efficiency of an exotic earthworm species (epigeic-Eisenia foetida) for decomposition of different types of organic substrates (kitchen waste, agro-residues, institutional and industrial wastes including textile industry sludge and fibres) into valuable vermicompost. The percentage of, nitrogen, phosphorous and potassium in vermicompost was found to increase while pH and total organic carbon declined as a function of the vermicomposting period. 4.4-5.8-fold increases in TKN was observed in different feed mixtures at the end of vermicomposting period. The increase in TKN for different feed substrates was found in the order: textile sludge>textile fibre=institutional waste>agro-residues>kitchen waste. Available Phosphorus increased 1.4 to 6.5-fold in different feed mixtures in comparison to control. Reduction in TOC was highest in agro-residues (3-fold) followed by kitchen waste (2.2-fold), institutional waste (1.7-fold) and textile industrial wastes (sludge, 1.5-fold and fibre, 1.68-fold) in earthworm-inoculated pots than control. The data reveals that vermicomposting (using E. foetida) is a suitable technology for the decomposition of different types of organic wastes (domestic as well as industrial) into value-added material.

Animals↗

Drip-feed bioreactor for the treatment of concentrated wastes with minimal dilution.

Avoiding substrate inhibition is a significant challenge in designing biological treatment systems for concentrated or toxic wastes. Substrate inhibition is commonly avoided by diluting the waste before treatment, however, dilution of a waste before treatment is not always feasible. In the case of radioactive mixed wastes and chemical warfare materiel (CWM), dilution presents regulatory and safety concerns. In this study, we investigated a "drip-feed" reactor configuration as an alternative approach for the biological treatment of concentrated waste streams with minimal dilution and complete containment. In the drip-feed reactor undiluted waste is slowly fed to biomass in a reactor at a rate sufficient to maintain activity, but at a low enough rate so that bacterial degradation maintains the reactor concentration below the toxic threshold. The reactor has no effluent, but rather fills as the undiluted waste is fed to the reactor, which has the advantage of preventing the release of hazardous material into the environment during treatment. Volatile releases are prevented with the use of condensers. The drip-feed bioreactor configuration was tested under aerobic conditions, at 25 degrees C, using a 10% acetonitrile feed solution. The treatment of acetonitrile to less than 0.1 mg l(-1) was achieved with a dilution factor of only 3.4. The acetonitrile degradation reaction was pH sensitive, where the optimal pH range for the biodegradation process was approximately between 6.5 and 7.1 and the biodegradation rate declined precipitously above pH 7.2. The applicability of the drip-feed reactor configuration to the treatment of mixed wastes and CWM is discussed.

Acetonitriles↗

Thermal treatment of toxic metals of industrial hazardous wastes with fly ash and clay.

Waste generated from galvanizing and metal finishing processes is considered to be a hazardous due to the presence of toxic metals like Pb, Cu, Cr, Zn, etc. Thermal treatment of such types of wastes in the presence of clay and fly ash can immobilizes their toxic metals to a maximum level. After treatment solidified mass can be utilized in construction or disposed off through land fillings without susceptibility of re-mobilization of toxic metals. In the present investigation locally available clay and fly ash of particular thermal power plant were used as additives for thermal treatment of both of the wastes in their different proportions at 850, 900 and 950 degrees C. Observed results indicated that heating temperature to be a key factor in the immobilization of toxic metals of the waste. It was noticed that the leachability of metals of the waste reduces to a negligible level after heating at 950 degrees C. Thermally treated solidified specimen of 10% waste and remaining clay have shown comparatively a higher compressive strength than clay fired bricks used in building construction. Though, thermally heated specimens made of galvanizing waste have shown much better strength than specimen made of metal finishing waste. The lechability of toxic metals like Cr, Cu, Pb and Zn became far below from their regulatory threshold after heating at 950 degrees C. Addition of fly ash did not show any improvement either in engineering property or in leachability of metals from the solidified mass. X-ray diffraction (XRD) analysis of the solidified product confirmed the presence of mixed phases of oxides of metals.

Aluminum Silicates↗

Quantification and classification of ship scraping waste at Alang-Sosiya, India.

Alang-Sosiya located on the Western Coast of Gulf of Cambay, is the largest ship recycling yard in the world. Every year on average 365 ships having a mean weight (2.10x10(6)+/-7.82x10(5) LDT) are scrapped. This industry generates a huge quantity of solid waste in the form of broken wood, rubber, insulation materials, paper, metals, glass and ceramics, plastics, leather, textiles, food waste, chemicals, paints, thermocol, sponge, ash, oil mixed sponges, miscellaneous combustible and non-combustible. The quantity and composition of solid waste was collected for a period of three months and the average values are presented in this work. Sosiya had the most waste 15.63 kg/m(2) compared to Alang 10.19 kg/m(2). The combustible solid waste quantity was around 83.0% of the total solid waste available at the yard, which represents an average weight of 9.807 kg/m(2); whereas, non-combustible waste is 1.933 kg/m(2). There is not much difference between the average of total solid waste calculated from the sampling data (96.71 MT/day) and the data provided by the port authorities (96.8 MT/day).

India↗

Improvement of nuclide leaching resistance of paraffin waste form with low density polyethylene.

Low-level liquid borate wastes have been immobilized with paraffin wax using a concentrate waste drying system (CWDS) in Korean nuclear power plants. The possibility for improving chemical durability of paraffin waste form was suggested in this study. A small amount of low density polyethylene (LDPE) was added to increase the leaching resistance of the existing paraffin waste form. The influence of LDPE on the leaching behavior of waste form was investigated by performing leaching test according to ANSI/ANS-16.1 procedure during 325 days. It was observed that the leaching of nuclides immobilized within paraffin waste form made a marked reduction although little content of LDPE was added to waste form. The acceptance criteria of paraffin waste form associated with leachability index (LI) and compressive strength after the leaching test were fully satisfied with the help of LDPE.

Cesium Radioisotopes↗

Prioritising objectives for waste reprocessing: a case study in secondary lead refining.

Secondary lead refining produces a sulphidic slag that also contains varying quantities of lead. Initially, the objectives of this project were to treat the slag in order to recover the valuable lead as well as to render the slag environmentally benign. However, in keeping with the principles of clean technology and, specifically, the approach of clean production, the project was redefined with the following priorities: waste characterisation; waste minimisation through process improvement; waste modification; identification of slag treatment methods. Characterisation of the waste facilitated an overall process understanding and aided in identifying process deficiencies. Process improvement was aimed at reducing both the quantity of slag produced as well as the lead loss to the slag. Waste characterisation combined with local hazardous waste regulations enabled desirable waste modifications to be identified. These waste adaptations were implemented through process modification. Lastly, treatment methods for the slag were identified.

Humans↗

Thermophilic anaerobic digestion of industrial orange waste.

Thermophilic anaerobic digestion of industrial orange waste (pulp and peel) with subsequent aerobic post-treatment of the digestate was evaluated. Methane production potential was first determined in batch assays and the effects of operational parameters such as hydraulic retention times (HRT) and organic loading rates (OLR) on process performance were studied through semi-continuous digestion. In batch assays, methane production potential of about 0.49 m(3) kg(-1) volatile solids (VS)(added waste) was achieved. In semi-continuous digestion, loading at 2.8 kgVS m(-3) d(-1) (2.9 kg total solids (TS) m(-3) d(-1)) and HRT of 26 d produced specific methane yields of 0.6 m(3) kg(-1) VS (added waste) (0.63 m(3) kg(-1) VS(added waste)). Operating at a higher OLR of 4.2 kgVS m(-3) d(-1) (4.4 kg TS m(-3) d(-1)) and 40 d HRT produced 0.5 m(3) of methane kg(-1) VS (added waste) (0.63-0.52 m(3) kg(-1) TS (added waste). Up to 70% of TS of industrial orange waste (11.6% TS) was methanised. Further increase in OLR to 5.6 kg VS m(-3) d(-1) (5.9 kg TS m(-3) d(-1); HRT of 20 d) resulted in an unstable and non-functional digester process shown directly through complete cessation of methanogenesis, drop in methane content, reduced pH and increase in volatile fatty acid (VFA) concentrations, especially acetate and soluble chemical oxygen demand. A pH adjustment (from an initial 3.2 to ca. 8) for the low pH orange waste was necessary and was found to be a crucial factor for stable digester operation as the process showed a tendency to be inhibited due to accumulation of VFAs and decrease in digester pH. Aerobic post-treatment of digestate resulted in removal of ammonia and VFAs.

Anaerobiosis↗

Mathematical-statistical models of generated hazardous hospital solid waste.

This research work was carried out under the assumption that wastes generated from hospitals in Irbid, Jordan were hazardous. The hazardous and non-hazardous wastes generated from the different divisions in the three hospitals under consideration were not separated during collection process. Three hospitals, Princess Basma hospital (public), Princess Bade'ah hospital (teaching), and Ibn Al-Nafis hospital (private) in Irbid were selected for this study. The research work took into account the amounts of solid waste accumulated from each division and also determined the total amount generated from each hospital. The generation rates were determined (kilogram per patient, per day; kilogram per bed, per day) for the three hospitals. These generation rates were compared with similar hospitals in Europe. The evaluation suggested that the current situation regarding the management of these wastes in the three studied hospitals needs revision as these hospitals do not follow methods of waste disposals that would reduce risk to human health and the environment practiced in developed countries. Statistical analysis was carried out to develop models for the prediction of the quantity of waste generated at each hospital (public, teaching, private). In these models number of patients, beds, and type of hospital were revealed to be significant factors on quantity of waste generated. Multiple regressions were also used to estimate the quantities of wastes generated from similar divisions in the three hospitals (surgery, internal diseases, and maternity).

Environmental Monitoring↗

Toxicological characterization of the new water cleaning product and its waste by-product.

Water extracts genotoxicity of the coagulant produced from industrial waste (red mud and waste base) and its waste mud remained after waste water treatment by the coagulation/flocculation process were studied. Tests were conducted in order to confirm nontoxicity of this new product prior to commercial production and usage and also to recommend a safe way for a handling and disposal of the remaining waste material. The toxicity investigation included (i) determining frequency of the cell survival, (ii) the Ames assays, (iii) micronucleus assay, and (iv) cell proliferation kinetics (expressed as mitotic index). These techniques were also employed in toxicity testing of the different concentrations of metal salts, zinc chloride, and lead nitrate in this case since these two elements were present in high concentrations in the waste water intended for the purification with the new coagulant. Mixture of metal salts in the concentrations that represent maximum allowed values for water extracts of technological waste was also tested. Two strains of Salmonella typhimurium, TA98, and TA100 were used for determining cytotoxicity and for the Ames test, while the cytogenetic investigations were performed on human peripheral blood lymphocytes. Water extracts of the coagulant and its waste mud did not induce a significant increase of the micronuclei in human peripheral blood lymphocytes. They also did not disturb lymphocyte proliferation kinetics in vitro. As regards lead nitrate it proved not to be cytotoxic on bacterial strains in the tested concentration range (1-100 mg/L), whereas zinc chloride showed cytotoxic effect for the concentrations above 25 mg/L. The Ames test results for the noncytotoxic concentrations of these metals were negative. Comparing to the negative control a significantly higher number of the micronuclei was determined after the treatment of the whole blood with 100 mg/L of zinc chloride, as well as with 10 and 100 mg/L of lead nitrate. A linear, dose dependent increase was obtained for both salts. Similar results were obtained on the basis of the mitotic index.

Cell Division↗

Dissemination of vancomycin-resistant enterococci harboring vanA through disposal of waste derived from industrial production of vancomycin.

We demonstrated the occurrence of vancomycin-resistant enterococci (VRE) in waste derived from the industrial production of vancomycin and their dissemination through disposal of such waste into a sewage treatment plant. Bacteriological counts on a medium selective for enterococci (Slanetz-Bartley agar) revealed the presence of high numbers of presumptive VRE (approximately 10(6) CFU/ml) in the waste originating from the fermentation biomass used for vancomycin production. The waste was also found to contain active residues of vancomycin (64-1,024 microg/ml) by bioassays using a vancomycin-susceptible enterococcal strain. Randomly amplified polymorphic DNA (RAPD) analysis of 65 presumptive VRE isolates from the waste allowed distinction of four genotypes, two of which (A and D) belonged to the genus Enterococcus, most likely E. faecium, and harbored the vanA gene conferring high-level vancomycin resistance. The same VRE strains found in the waste occurred also in the biological tanks and the final effluent of the sewage treatment plant receiving the waste, as demonstrated by the detection of undistinguishable pulsed-field gel electrophoresis (PFGE) patterns in VRE isolated from these sources. These results indicate the need to assess the possible dissemination of VRE and other antibiotic-resistant bacteria through disposal of waste derived from antibiotic production.

Anti-Bacterial Agents↗

Managing radioactively contaminated infectious waste at a large biomedical facility.

Proper management of infectious waste containing radioactive material depends on three program elements. First, screening methods are required to identify medical waste containing radioactive material. Second, a means of managing the volume of waste identified has to be developed. Management includes identifying the radioisotopes, dealing with the physical requirements of the waste (e.g., the need for cold storage), and treating the material as a mixed waste. Finally, methods to limit production of waste at its source must be implemented. This includes educating the radioactive material users, enabling them with the means of reducing waste volume, and giving them feedback on how well they are implementing the waste reduction practices.

Academic Medical Centers↗

Radioactive waste minimization at a large academic medical facility.

The University of Texas Medical Branch (UTMB) at Galveston is a large academic medical center with about 12,700 employees, 350 radioisotope research labs and 200 permitted radioactive materials users. Consequently, UTMB generates a fairly large amount of radioactive waste. The majority of this waste contains short-lived radionuclides, such as 32P, 33P, and 35S, which are held for decay and then disposed at a sanitary landfill. However, some waste, including long-lived waste and stock vials, is compacted into drums and stored in a warehouse facility, on-site, until disposal at a low-level radioactive waste (LLRW) facility. Space in the warehouse is limited but disposal is currently cost prohibitive. A reevaluation of our program was conducted to see if volumes of LLRW requiring disposal at a commercial LLRW facility could be reduced. A reevaluation of the waste streams resulted in the shifting of most of the material that was being drummed for shipment to a LLRW facility to disposal by landfill or incineration. Materials that were previously assumed to be radioactive are now being evaluated prior to disposal to determine if they may be disposed of as non-radioactive waste. Following the initial evaluation, the amount of compacted dry solids assumed to contain long-lived radionuclides was reduced. The space that was saved due to the decrease in drumming for disposal is now used to hold the increased volume of decay-in-storage material. The monetary savings will amount to about $45,000 per year. This program is currently being expanded to reduce other waste streams at the university.

Academic Medical Centers↗

An industry perspective on commercial radioactive waste disposal conditions and trends.

The United States is presently served by Class-A, -B and -C low-level radioactive waste and naturally-occurring and accelerator-produced radioactive material disposal sites in Washington and South Carolina; a Class-A and mixed waste disposal site in Utah that also accepts naturally-occurring radioactive material; and hazardous and solid waste facilities and uranium mill tailings sites that accept certain radioactive materials on a site-specific basis. The Washington site only accepts low-level radioactive waste from 11 western states due to interstate Compact restrictions on waste importation. The South Carolina site will be subject to geographic service area restrictions beginning 1 July 2008, after which only three states will have continued access. The Utah site dominates the commercial Class-A and mixed waste disposal market due to generally lower state fees than apply in South Carolina. To expand existing commercial services, an existing hazardous waste site in western Texas is seeking a Class-A, -B and -C and mixed waste disposal license. With that exception, no new Compact facilities are proposed. This fluid, uncertain situation has inspired national level rulemaking initiatives and policy studies, as well as alternative disposal practices for certain low-activity materials.

Decision Making↗

[Gravimetric characterization of potentially infectious material in urban solid waste in southern Belo Horizonte, Minas Gerais State, Brazil].

This study investigated potentially infectious waste (feces, urine, blood, body fluids) in the composition of total municipal solid waste. From August to September 2002, solid waste samples from southern Belo Horizonte, capital of the State of Minas Gerais, were collected and sent to the solid waste treatment and disposal site at BR-040 for segregation and quantification. Sharps (objects that can cause cuts or puncture wounds) made up 0.02+/-0.02% of the collected waste, while non-sharps accounted for 5.47+/-1.11%. In the sharps category, the majority were razor blades (0.01+/-0.01%), while among non-sharps the most frequent components were toilet paper (3.00+/-0.90%), diapers (2.21+/-1.08%), and sanitary napkins (0.22+/-0.12%). Household infectious waste was twice the total amount of waste (infectious + common) from healthcare units. The study was discussed in light of the health hazards and safety aspects for formal and informal waste collectors.

Brazil↗

[Clinical waste disposal].

Public health centers and private practitioners are responsible for the disposal of waste generated by their activities. In spite of the quantities being small, it may be hazardous for patients, clinicians, technician's safety and the environment. This issue is not driven by the lack of appropriate rules. There are plenty of terminology. Evaluation of the risks allows the appropriate protective measures to be put in place. A dedicated organization for handling each type of waste is required. Because not all waste may be hazardous, a health scientist must identify and categorize the risk factors associated with the waste. Waste disposal is handled in two ways. One according to the level of hazard, the other as domestic waste. The waste handling is managed in three phases: diagnostic, data collection and decision making. The supervisory staff must advise and train all people who may come into contact with such waste.

Europe↗

[Cause-specific mortality in an area of Campania with numerous waste disposal sites].

OBJECTIVE: To investigate cause-specific mortality in an area of Campania region, in the surroundings of Naples, characterized by many toxic waste dumping grounds sites and by widespread burning of urban wastes. DESIGN: The study area was characterized by examining the spatial distribution of waste disposal sites and toxic waste dumping grounds, using a geographic information system (GIS). Mortality (1986-2000) was studied in the three municipalities of Giugliano in Campania, Qualiano and Villaricca, encompassing a population of about 150,000 inhabitants. Mortality rates of the population resident in the Campania region were used in order to generate expected figures. OUTCOMES: Causes of death of a priori interest where those previously associated to residence in the neighbourhood of (toxic) waste sites, including lung cancer, bladder cancer, leukemia and liver cancer. RESULTS: Overall 39 waste sites, 27 of which characterized by the likely presence of toxic wastes, were identified in the area of interest. A good agreement was found between two independent surveys of the Regional Environmental Protection Agency and of the environmentalist association Legambiente. Cancer mortality was significantly increased, with special reference to malignant neoplasm of lung, pleura, larynx, bladder, liver and brain. Circulatory diseases were also significantly in excess and diabetes showed some increases. CONCLUSIONS: Mortality statistics provide preliminary evidence of the disease load in the area. Mapping waste dumping grounds provides information for defining high risk areas. Improvements in exposure assessment together with the use of a range of health data (hospital discharge cards, malformation notifications, observations of general practitioners) will contribute to second generation studies aimed at inferring causal relationships.

Cause of Death↗