PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Workflow”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

An AI-assisted Clinical Decision Support System for Green Classification of Cystocele on Dynamic Transperineal Ultrasound.

Green classification of cystocele on dynamic transperineal ultrasound (TPUS) remains operator-dependent because it requires manual frame selection and landmark-based assessment of the Valsalva maneuver. We developed a workflow-oriented AI-assisted clinical decision support system for automated urethrovesical junction localization and dynamic Green classification and prospectively evaluated its standalone and reader-support performance. This diagnostic accuracy and reader study included 881 patients from a tertiary referral hospital, comprising a retrospective development cohort (n = 688) and an independent prospective test cohort (n = 193). A nested subset of 67 prospective patients was used for a reader study involving two junior and two intermediate radiologists under unaided and AI-assisted conditions. In the complete prospective test cohort, Green-AttGRU achieved a macro-averaged AUC of 0.939 (95% CI, 0.897-0.971) and an overall accuracy of 0.902 (95% CI, 0.860-0.943). In the reader study, overall accuracy increased from 0.761 to 0.821 without AI to 0.851-0.881 with AI, while macro-F1 increased from 0.660 to 0.777 to 0.820-0.860. Overall inter-reader agreement increased from a Fleiss' κ of 0.453 to 0.786, and pooled median interpretation time decreased from 26.7 s to 9.9 s. These findings support the preliminary feasibility of the system as a workflow-oriented decision-support tool for dynamic TPUS interpretation.

Humans↗

Site-specific gene integration by recombinase-mediated cassette exchange in anhydrobiotic Pv11 cells.

Pv11 cells, derived from Polypedilum vanderplanki, uniquely tolerate complete desiccation (anhydrobiosis). Although a CRISPR/Cas9-based precise integration method (CRIS-PITCh) has been developed for Pv11 cells, a CRISPR-free strategy that fixes both the genomic locus and transgene copy number has not yet been established. Here, we implement recombinase-mediated cassette exchange (RMCE) in Pv11 cells and generate master cell lines that retain anhydrobiosis following genetic engineering. We first evaluated the activity of multiple site-specific recombinases in Pv11 cells using a transient two-plasmid reporter assay. Flp, Cre, and Bxb1 recombinases all excised a test cassette and activated a green fluorescent protein (GFP) reporter, whereas phiC31 integrase mediated recombination at the DNA sequence level but did not induce reporter expression under our construct configuration. To enable genomic RMCE, we inserted an FRT/FRT3-landing pad (LP) into a previously identified genomic safe-harbor locus using CRIS-PITCh and isolated clonal master cell lines by single-cell sorting. Using the established master line, Flp-based RMCE achieved site-specific cassette exchange at the LP, producing HaloTag fluorescence and drug resistance upon successful exchange. In addition, the expected post-exchange sequence was confirmed by sequencing. We further established an all-in-one RMCE vector combining the Flp recombinase and donor cassette on a single plasmid. Together, these results demonstrate locus-defined, single-copy transgene integration in anhydrobiotic Pv11 cells via RMCE and provide a standardized, CRISPR-free workflow for routine genetic manipulation in this unique cell line. This workflow facilitates both fundamental research and applied biotechnological applications using desiccation-tolerant cells.

Anhydrobiosis↗

Multi-detector computed tomography and 3-dimensional imaging in a multi-vendor picture archiving and communications systems (PACS) environment.

RATIONALE AND OBJECTIVES: To show the impact of the introduction of multi-detector computed tomography (CT) on radiologic workflow and to demonstrate how this reflects on picture archiving and communications systems (PACS) requirements. MATERIALS AND METHODS: Production measurements were obtained from different CT scanners (first two single-slice CT scanners; from December 2001 single and 4-slice CT; from April 2002 single and 16-slice CT) in number of patients from the radiologic information system. Implications on our PACS were recorded in terms of images and studies stored. Furthermore, our PACS design was made so that optimal use of 3-dimensional imaging within the radiologic workflow was possible. Finally, the number of non-diagnosed studies were recorded every day since the start of the transition to a filmless radiology department. RESULTS: This PACS design achieved a high level of integration between simple viewing and advanced 3-dimensional imaging and is optimized for handling large amounts of data. Overall increase of patients scanned with CT from January 2002-December 2003 was 54%. The number of series increased by 286% from December 2001-April 2003 and by 130% from April 2002-December 2003. From January 2002-February 2003, the number of images per patient increased from 175 to 450 (157%). Non-diagnosed studies decreased from about 100-120 before to practically zero after PACS implementation. CONCLUSION: PACS significantly increases productivity because of availability of the images and elimination of certain manual tasks. These results show that although the amount of examinations increases significantly with the introduction of MDCT, simultaneous introduction of PACS and filmless operation allows radiologists to handle the growth in workload.

Efficiency↗

Functional screening and single-cell cultivation of marine CO2-fixing bacteria via flow-mode Raman-activated cell sorting.

Most marine CO2-fixing microorganisms remain uncultivated due to strong culture bias and low throughput of conventional approaches, which fail to link in situ function with isolated strains and render slow-growing or low-abundance taxa virtually inaccessible. This study presents an integrated single-cell workflow that incorporates 13C-NaHCO3 labeling, high-throughput flow-mode Raman-activated cell sorting (RACS) and microwell cultivation for the isolation of active CO2-fixing bacteria from the Yellow Sea. Function-guided sorting was achieved by monitoring the 13C-induced Raman shifts of carotenoids (ν1 band: ∼1507 to ∼ 1503.78 cm-1 at 24 h). Genomic and physiological analyses identified Paraburkholderia aromaticivorans FR-4 as a novel facultative chemoautotrophic nitrite-oxidizing bacterium (NOB). Its genome encodes complete nitrite oxidation and Calvin cycle pathways, together with key carbon acquisition genes (carbonic anhydrase, bicarbonate transporter). FR-4 grows autotrophically using NO2- as the electron donor and CO2/HCO3- as the carbon source, confirming its ability to couple nitrite oxidation with carbon fixation, while retaining metabolic flexibility for heterotrophic growth. By directly linking in situ carbon-fixing activity, genotype, and phenotype, this workflow provides a targeted strategy for exploring elusive marine CO2-fixing bacteria and overcomes critical limitations of conventional cultivation.

Carbon-fixing↗

Age-associated variation in lipid composition and nutritional quality of the invasive bivalve Anadara kagoshimensis from the Sea of Azov.

This study examined age-associated variation in lipid composition and nutritional quality in the invasive clam Anadara kagoshimensis from the Sea of Azov. Fatty acid and sterol compositions were determined by gas chromatography in clams assigned by sclerochronology to five age classes (2-6 years). Several lipid-quality indices, including PUFA/SFA, IA, IT, hH, and HPI, exhibited their most favorable mean values in the 4-year group. The highest condition index (13.7) and the lowest n-3/n-6 ratio (1.1) were observed in the small and unbalanced group of 6-year-old clams. An exploratory linear discriminant analysis (LDA) workflow was used to examine whether primary lipid variables and mathematically derived composite features could enhance age-group separation. LDA based on primary variables yielded 78% leave-one-out classification within the present dataset. Data-driven composite-feature construction increased the within-dataset classification to 100% and graphical group separation to 85%, the values with yet restricted predictive accuracy due to the limited dataset. The results provide baseline information on age-associated lipid variation in A. kagoshimensis and illustrate a proof-of-concept workflow that can be tested in future studies using larger, balanced samples and special validation approaches.

Arcidae↗

Imaging technologies and techniques.

Equipment manufacturers provide contrast-specific detection techniques that have excellent sensitivity and excellent agent-to-tissue specificity along with helpful tools that improve workflow efficiency dramatically. Excellent contrast agents have been approved for LV opacification and are available worldwide. Techniques designed for low-MI imaging offer real-time acquisition capabilities and lead to faster examinations. Techniques designed for medium-MI imaging offer better sensitivity than low-MI techniques while maintaining the benefit of rapid image acquisition. Techniques designed for high-MI imaging offer the best sensitivity with longer acquisition times. These techniques are viable means for imaging contrast agents tailored to clinical needs. Progress by contrast agent manufacturers, equipment manufacturers, and physicians will continue to drive improvements in the areas of detection and clinical workflow for improved patient care.

Coronary Circulation↗

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (ρ = 0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2 ≈ 12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2 ≈ 41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (≈1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans↗

PANAMA-enabled high-sensitivity dual nanoflow LC-MS metabolomics and proteomics analysis.

High-sensitivity nanoflow liquid chromatography (nLC) is seldom employed in untargeted metabolomics because current sample preparation techniques are inefficient at preventing nanocapillary column performance degradation. Here, we describe an nLC-based tandem mass spectrometry workflow that enables seamless joint analysis and integration of metabolomics (including lipidomics) and proteomics from the same samples without instrument duplication. This workflow is based on a robust solid-phase micro-extraction step for routine sample cleanup and bioactive molecule enrichment. Our method, termed proteomic and nanoflow metabolomic analysis (PANAMA), improves compound resolution and detection sensitivity without compromising the depth of coverage as compared with existing widely used analytical procedures. Notably, PANAMA can be applied to a broad array of specimens, including biofluids, cell lines, and tissue samples. It generates high-quality, information-rich metabolite-protein datasets while bypassing the need for specialized instrumentation.

Proteomics↗

A randomized, controlled trial evaluating the impact of a computerized rounding and sign-out system on continuity of care and resident work hours.

BACKGROUND: Adoption of limits on resident work hours prompted us to develop a centralized, Web-based computerized rounding and sign-out system (UWCores) that securely stores sign-out information; automatically downloads patient data (vital signs, laboratories); and prints them to rounding, sign-out, and progress note templates. We tested the hypothesis that this tool would positively impact continuity of care and resident workflow by improving team communication involving patient handovers and streamlining inefficiencies, such as hand-copying patient data during work before rounds ("prerounds"). STUDY DESIGN: Fourteen inpatient resident teams (6 general surgery, 8 internal medicine) at two teaching hospitals participated in a 5-month, prospective, randomized, crossover study. Data collected included number of patients missed on resident rounds, subjective continuity of care quality and workflow efficiency with and without UWCores, and daily self-reported prerounding and rounding times and tasks. RESULTS: UWCores halved the number of patients missed on resident rounds (2.5 versus 5 patients/team/month, p = 0.0001); residents spent 40% more of their prerounds time seeing patients (p = 0.36); residents reported better sign-out quality (69.6% agree or strongly agree); and improved continuity of care (66.1% agree or strongly agree). UWCores halved the portion of prerounding time spent hand-copying basic data (p < 0.0001); it shortened team rounds by 1.5 minutes/patient (p = 0.0006); and residents reported finishing their work sooner using UWCores (82.1% agree or strongly agree). CONCLUSIONS: This system enhances patient care by decreasing patients missed on resident rounds and improving resident-reported quality of sign-out and continuity of care. It decreases by up to 3 hours per week (range 1.5 to 3) the time used by residents to complete rounds; it diverts prerounding time from recopying data to more productive tasks; and it facilitates meeting the 80-hour work week requirement by helping residents finish their work sooner.

Continuity of Patient Care↗

The aging of a clinical information system.

The senescence of a clinical information system is more likely to have administrative than technical bases. Supporting this claim is a case study of one aging oncology information system. The case study is qualitative, as behooves the subject matter. Content analysis of several documents suggests that the change in job description of the data coordinator led to a workflow breakdown. Next, twenty-two individuals were interviewed. Notes from the interviews were coded, and the resulting patterns led to partial support for the workflow breakdown conjecture, refutation of the hypothesis that users disliked the character-based, human-computer interface, support of the conjecture that political rather than technical factors drive the usage patterns of the system, and evidence that 'political' activity will determine the future of the information system. A stakeholder matrix is proposed that addresses administrative concerns. Also, the issue of the uniqueness of any oncology clinical information system is linked to the plans for this legacy system.

Databases, Factual↗

Radiology interpretation process modeling.

Information and communication technology in healthcare promises optimized patient care while ensuring efficiency and cost-effectiveness. However, the promised results are not yet achieved; the healthcare process requires analysis and radical redesign to achieve improvements in care quality and productivity. Healthcare process reengineering is thus necessary and involves modeling its workflow. Even though the healthcare process is very large and not very well modeled yet, its sub-processes can be modeled individually, providing fundamental pieces of the whole model. In this paper, we are interested in modeling the radiology interpretation process that results in generating a diagnostic radiology report. This radiology report is an important clinical element of the patient healthcare record and assists in healthcare decisions. We present the radiology interpretation process by identifying its boundaries and by positioning it on the large healthcare process map. Moreover, we discuss an information data model and identify roles, tasks and several information flows. Furthermore, we describe standard frameworks to enable radiology interpretation workflow implementations between heterogeneous systems.

Canada↗

A taxonomic description of computer-based clinical decision support systems.

OBJECTIVE: Computer-based clinical decision support systems (CDSSs) vary greatly in design and function. Using a taxonomy that we had previously developed, we describe the characteristics of CDSSs reported in the literature. METHODS: We searched PubMed and the Cochrane Library for randomized controlled trials (RCTs) published in English between 1998 and 2003 that evaluated CDSSs. We coded each CDSS using our taxonomy. RESULTS: 58 studies met our inclusion criteria. The 74 reported CDSSs varied greatly in context of use, knowledge and data sources, nature of decision support offered, information delivery, and workflow impact. Two distinct subsets of CDSSs were seen: patient-directed systems that provided decision support for preventive care or health-related behaviors via mail or phone (38% of systems), and inpatient systems targeting clinicians with online decision support and direct online execution of the recommendations (18%). 84% of the CDSSs required extra staffing for handling CDSS-related input or output. CONCLUSION: Reported CDSSs are heterogeneous along many dimensions. Caution should be taken in generalizing the results of CDSS RCTs to different clinical or workflow settings.

Databases, Bibliographic↗

Nonviral transposon&#x2011;engineered stem cells characterization: dose&#x2011;dependency between vector copy number and transgene expression.

Genetically engineered stem cells hold substantial promises for advancing regenerative medicine, yet ensuring their genomic safety remains a critical challenge. A key safety concern is vector copy number (VCN), which defines the number of integrated transgene copies per genome. Although ddPCR is used to assess VCN in virally transduced cells, its application in transposon&#x2011;engineered systems is limited. In this study, we extended VCN determination to non&#x2011;viral, transposon&#x2011;engineered stem cells. In alignment with FDA recommendations, the primary objective was to establish a robust and quantitative framework for interim VCN determination at the time of lot release. Specifically, we demonstrate that reliable interim VCN estimates increase in a dose&#x2011;dependent manner with increasing plasmid input. In addition, strong linear correlations between VCN and both EGFP median fluorescence intensity (MFI) and gene&#x2011;of&#x2011;interest (GOI) protein expression validate the accuracy of this framework. Furthermore, comparison of two distinct GOIs revealed gene&#x2011;specific differences in expression efficiency. Together, these findings validate a standardized VCN determination workflow that quantitatively links plasmid dose, genomic integration, and functional transgene expression. This workflow provides a systematic characterization of engineered cells, offering comprehensive information to support downstream risk&#x2011;based analyses to ensure the genomic safety and stability of the final cell product.

Transgenes↗

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans↗

Towards a Robust cell-free DNA Isolation Protocol for NGS Applications in a Clinical Molecular Diagnostics Setting.

Cell-free DNA (cfDNA), released from apoptotic and necrotic cells into body fluids, is a non-invasive source of genetic information for disease prediction, diagnosis, and monitoring. However, its low abundance makes cfDNA highly susceptible to various pre-analytical influences, potentially increasing high molecular weight (HMW) or genomic DNA (gDNA) compromising downstream cfDNA analyses. This study evaluated the impact of different cfDNA-stabilizing blood collection tubes (BCT; Cell-Free DNA BCT, Streck; S-Monovette cfDNA Exact, Sarstedt) stored at room temperature for 1, 5, or 10 days, prior to plasma isolation using different isolation methods (magnetic bead-based or silica column-based) on cfDNA stability and yield. DNA quantity and quality were assessed by fluorometric quantification, automated fragment analysis, and gene-specific quantitative PCR. Streck-based workflows maintained stable cfDNA yields and characteristic mononucleosomal fragmentation profiles across all storage times. In contrast, Sarstedt tubes showed reduced cfDNA concentrations after 5 days and a pronounced increase at 10 Days, accompanied by high-molecular weight DNA patterns consistent with white-blood cells (WBC) lysis. These trends were largely independent of the extraction method. Overall, the results demonstrate that blood collection tube chemistry critically influences cfDNA integrity during delayed processing. Streck tubes, particularly when combined with silica column-based isolation method, provided the most robust and reproducible workflow for routine molecular diagnostics, whereas Sarstedt tubes produced physiologically implausible results after extended storage.

blood collection tubes↗

Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.

Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p&#x202f;<&#x202f;0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7&#x202f;h, whereas rapid barcoding required approximately 40&#x202f;h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200&#x202f;min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.

Poliovirus↗

Evaluation of one-step amplicon-based targeted enrichment for SARS-CoV-2 whole-genome sequencing using the Midnight amplicon scheme.

Genomic surveillance proved invaluable during the COVID-19 pandemic for tracking SARS-CoV-2 variants and guiding outbreak responses, underscoring the ongoing need to reduce whole-genome sequencing (WGS) costs and improve workflow efficiency to ensure accessibility in resource limited settings. Here, we evaluated a one-step reverse transcription polymerase chain reaction (RT-PCR) approach using the Midnight V2 primer scheme for targeted amplification of the SARS-CoV-2 genome, assessed its compatibility with Illumina sequencing, and compared its performance to a well-established two-step method. Initially, we determined optimal RT-PCR reaction conditions using the Midnight V2 primer panel for the one-step RT-PCR kit and scaled reaction volumes for both RT-PCR and library preparation. Clinical specimens (n&#x202f;=&#x202f;53) that had undergone routine WGS for surveillance purposes using the established two-step RT-PCR method were compared using the one-step RT-PCR assay. For samples with genome completeness greater than 70%, both methods gave comparable results with similar sequence coverage and 100% concordance for lineage assignment. Further investigation revealed a higher percentage of reads aligning to the SARS-CoV-2 genome with a greater depth of coverage using the one-step method compared to the two-step method. Finally, analysis of scaled one-step and library reaction volumes revealed significant cost savings for samples undergoing WGS. Overall, the results presented here verify the accuracy and reproducibility of one-step targeted amplification and offer an efficient and cost-effective workflow for routine SARS-CoV-2 genomic surveillance.

Humans↗

Antimicrobial resistance surveillance through wastewater: methodological considerations for metagenomic approaches and public health perspectives.

Antimicrobial resistance (AMR) is a recognised global threat with substantial predicted impact on lives, agriculture, and the economy. Metagenomic sequencing is being increasingly used for AMR surveillance and detection, given its capacity for community-level AMR profiling with high-level resolution. This technology has seen an explosion of surveillance efforts and data generation; however, the variation between workflows has direct implications on the sequencing results and their interpretation. In this Personal View, we summarise aspects of the sequencing workflow that need to be considered during metagenomic study design, for meaningful and reliable population-based surveillance. We reflect on the vital role of standardisation for capturing the ground truth of AMR and data comparability and reproducibility, and in addition, review the limitations of the various phenotypic and genotypic methods of AMR detection. We further highlight complex mechanisms of resistance to antimicrobials that could hinder our ability to confidently assess the true AMR burden in the environment and those that are often overlooked during surveillance.

Metagenomics↗