PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “performance”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Some applications of near-ultraviolet laser-induced fluorescence detection in nanomolar- and subnanomolar-range high-performance liquid chromatography or micro-high-performance liquid chromatography.

In this work we present some applications of near-UV laser-induced fluorescence (LIF) with micro-HPLC (microHPLC) and HPLC. To test the sensitivity of the detection, we used pyrene and aflatoxins, because both of these molecules exhibit native fluorescence. Then we studied catecholamines derivatized with 1,2-diphenylethylenediamine. The results show that we were able to reach better sensitivity levels than previously described in LIF studies. For catecholamines, a 50-fold increase in sensitivity compared to conventional fluorescence was obtained. These results indicate that LIF detection associated with HPLC or microHPLC can be used to detect very low concentrations of substances that can be excited in the near-UV range after labeling at nanomolar concentrations.

Aflatoxins↗

High-performance liquid chromatography of amino acids, peptides and proteins. LXVII. Evaluation of bandwidth relationships of peptides related to human beta-endorphin, separated by gradient-elution reversed-phase high-performance liquid chromatography.

The bandwidths of several polypeptides related to human beta-endorphin have been investigated with different n-alkylsilica stationary phases and different elution gradients of 0.1% trifluoroacetic acid-water-acetonitrile mobile phases. In particular, we have examined the influence of changes in the gradient steepness parameter, b, on peakwidth with five different octadecylphases, chemically bonded to porous spherical silica particles of nominally 4 micron and 6 micron average particle diameter, respectively. The effect on the zone dispersion of these polypeptide solutes as the average pore diameter of the silica matrix was increased from 7.3 nm to 30 nm with stationary phases of similar ligand densities packed into columns of identical configuration has been further documented. The experimental data on solute bandwidths and peak capacities are comparable with the corresponding bandwidth and peak capacity values calculated from analytical equations, derived from the general plate height theory and from gradient elution theory. These comparisons clearly demonstrate that anomalous bandbroadening phenomena may occur when polypeptides are eluted with steep gradients, i.e. with gradients of large b values. Moreover, as the relative chromatographic residence times of beta-endorphin peptides capable of forming a C-terminal amphiphilic secondary structures is increased, i.e. as the dwell times and median capacity factors, k, for such peptides are increased, significant divergencies arise between the observed peakwidth behaviour and the behaviour predicted by analytical relationships which describe either the dependency of peak bandwidth (as 4 sigma v) on the gradient steepness parameter, b, or the dependency of peak capacity on gradient time, tG, median capacity factor, k, and the Knox parameter, C, respectively. The importance of these divergences from the predicted bandwidth and peak capacity behaviour for polypeptides separated on reversed phases, and for resolution optimisation in particular, is evaluated. These investigations thus enable further assessment of the quantitative relevance of current models that describe polypeptide zone migration under gradient elution reversed-phase chromatographic conditions in which solute-dependent slow equilibria, mediated by conformational or solvation effects, may still occur.

Amino Acids↗

High-performance liquid chromatography of amino acids, peptides and proteins. XLVIII. Retention behaviour of tryptic peptides of human growth hormone isolated by reversed-phase high-performance liquid chromatography: a comparative study using different chromatographic conditions and predicted elution behaviour based on retention coefficients.

The retention behaviour of the tryptic peptides of human growth hormone under a variety of reversed-phase chromatographic conditions has been investigated. By using water-acetonitrile gradients containing phosphate, bicarbonate, trifluoroacetate, or heptanesulphonate buffers, the influence of these ionic modifiers on peptide selectivity with several different alkylsilicas has been examined. Comparisons of observed and predicted retention behaviours for the various tryptic peptides in the different chromatographic systems are described. Application of these systems to the isolation of deamidated forms of human growth hormone is presented.

Amino Acids↗

High-performance liquid chromatography of amino acids, peptides and proteins. XLVII. Analytical and semi-preparative separation of several pituitary proteins by high-performance ion-exchange chromatography.

The chromatographic separation of several pituitary proteins on a Mono-Q anion-exchange column is described. The effect of eluent pH and buffer composition on the resolution is demonstrated with several standard proteins. The experimental data indicate that good protein recoveries and resolution can be obtained on this essentially monodisperse microparticulate ion-exchange resin when the pH of the eluent is chosen ca. 0.5 pH units below the pI of the most basic component in the mixture. With this new column separations are ca. 30 times faster than with conventional cellulosic anion exchangers at similar sample loads.

Animals↗

Evaluation of advanced silica packings for the separation of biopolymers by high-performance liquid chromatography. VI. Design, chromatographic performance and application of non-porous silica-based anion exchangers.

The linear solvent strength model of Snyder was applied to describe fast protein separations on 2.1-micron non-porous, silica-based strong anion exchangers. It was demonstrated on short columns packed with these anion exchangers that (i) a substantially higher resolution of proteins and nucleotides was obtained at gradient times of less than 5 min than on porous anion exchangers; (ii) the low external surface area of the non-porous anion exchanger is not a critical parameter in analytical separations and (iii) microgram-amounts of enzymes of high purity and full biological activity were isolated.

Biopolymers↗

High-performance liquid chromatography of amino acids, peptides and proteins. LXIX. Evaluation of retention and bandwidth relationships of myosin-related peptides separated by gradient elution reversed-phase high-performance liquid chromatography.

The gradient elution behaviour of ten peptide analogues encompassing the primary amino acid sequences adjacent to the serine-19 phosphorylation site of myosin light chain has been investigated using a 30-nm pore diameter n-butylsilica stationary phase and 0.1% trifluoroacetic acid-water-acetonitrile mobile phases. Quantitative expressions derived from linear solvent strength theory and general plate height theory have been used to assess the influence of gradient time and flow-rate on the relative retentions and bandwidths of these peptides. The retention behaviour of these peptide analogues was found to closely mirror the predictions of linear solvent strength gradient elution theory. Although the experimentally observed band-width changes over a conventional range of gradient conditions (i.e. tG = 30-60 min) also correlated with bandwidth changes predicted on the basis of plate theory derived for low molecular weight organic molecules, for very steep and very shallow gradients divergencies from theory were observed. The significance of these discrepancies is discussed in relation to the influence of amino acid sequence changes rather than composition of these peptide analogues. These data allow the importance of sequential effects on the chromatographic behaviour and in particular, the resolution optimisation of these closely related peptides to be evaluated.

Amino Acids↗

Quantitation of spectinomycin residues in bovine tissues by ion-exchange high-performance liquid chromatography with post-column derivatization and confirmation by reversed-phase high-performance liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry.

Determinative and confirmatory methods of analysis for spectinomycin residue in bovine kidney, liver, muscle and fat have been developed. The determinative method is a single-column HPLC ion-exchange procedure that incorporates a two-step post-column oxidation of the secondary amines to primary amines followed by derivatization with o-phthalaldehyde. The method was validated in all tissues to a low-end concentration of 0.10 micrograms/g (limit of quantitation) and to a high-end of 10 micrograms/g for kidney, which is the rate-limiting tissue for residues of spectinomycin. The recovery of spectinomycin from all tissues was > 80% and the variability (R.S.D.) was generally < 10%. For liver, an alternative reversed-phase HPLC separation was required for incurred-residue samples. The confirmatory method employed an atmospheric pressure chemical ionization-MS-MS approach utilizing a rapid reversed-phase HPLC system with a mobile phase of methanol and 1% acetic acid. The protonated molecular ion for spectinomycin at m/z 333 produced four diagnostic reaction-product ions at 98, 116, 158 and 189 for confirmation. The method was validated to a lower limit of confirmation of 0.10 micrograms/g.

Animals↗

Mutation analysis of MLH1 and MSH2 genes performed by denaturing high-performance liquid chromatography.

Mutation analysis of large genes, such as MSH2 and MLH1, is time-consuming and expensive. We investigated the sensitivity and specificity of DHPLC analysis for the detection of mutations within both MSH2 and MLH1. Studies included a series of 46 patients affected by colorectal cancer from HNPCC families. We confirmed 19 changes previously identified by DNA sequencing and, in a blind study, an additional 16 rare alterations including four mutations not previously described. Generally, false negative results were not observed. Elution profiles were highly characteristic for a given change and in 98.5% cases allowed the distinction between novel alterations and previously identified mutations and polymorphisms. For the detection of changes in almost all amplicons, it was sufficient to use just one denaturing temperature. DHPLC was confirmed to be highly sensitive, specific and a cost-effective technique with particularly high potential for the detection of MSH2 and MLH1 gene mutations in the diagnostic setting.

Adaptor Proteins, Signal Transducing↗

Identification and quantification of metabolites of 2,3,5,6-tetrafluoro-4-trifluoromethylaniline in rat urine using 19F nuclear magnetic resonance spectroscopy, high-performance liquid chromatography-nuclear magnetic resonance spectroscopy and high-performance liquid chromatography-mass spectrometry.

The urinary excretion profile and identity of the metabolites of 2,3,5,6-tetrafluoro-4-triflouromethylaniline, following i.p. administration to the rat at 50 mg kg(-1), were determined using a combination of 19F-NMR, HPLC-NMR and HPLC-MS. A total of 38% of the dose was eliminated in the urine as five metabolites. The major routes of metabolism were N-glucuronidation, sulfation and oxidation with a significant amount of metabolic defluorination to give a number of ortho-ring hydroxylated metabolites. The oxidised metabolites were excreted as glucuronide and/or sulfate conjugates.

Aniline Compounds↗

High-performance liquid chromatography of amino acids, peptides and proteins. LXIII. Reversed-phase high-performance liquid chromatographic characterisation of several polypeptide and protein hormones.

The chromatographic behaviour on alkylsilicas of a variety of hormonal proteins is described. Optimization of resolution and recovery of these protein hormones, which included porcine relaxins, human chorionic gonadotropin, human placental lactogen, pituitary derived growth hormone and adenohypophyseal glycoprotein hormones, was achieved by manipulation of both mobile and stationary phase parameters. With standard stainless-steel analytical columns (10-30 cm X 0.4 cm) packed with meso- or macro-porous n-alkylsilica supports these proteins can be readily fractionated at the semi-preparative level with separation times generally under 90 min using elution systems directly compatible with subsequent methods of primary structure determination or biological functional analysis. The effects of changes in several experimental parameters on peak symmetry, retention and recovery are described.

Amino Acids↗

High-performance thin-layer chromatographic determination of N-ethyl-3,4-methylenedioxyamphetamine and its major metabolites in urine and comparison with high-performance liquid chromatography.

The consumption of N-ethyl-3,4-methylenedioxyamphetamine (MDE, 1), an analogue of ecstasy, can be detected by direct in situ HPTLC-FTIR measurement of the main metabolite N-ethyl-4-hydroxy-3-methoxyamphetamine (HME, 2). HME (2) can, like the other important metabolite 3,4-methylenedioxyamphetamine (MDA, 3) and unchanged MDE (1), be determined quantitatively in urine by HPTLC-UV after two-step automatic development. The results have been compared with those obtained using an HPLC method. The differences were not generally significant. Small deviations were attributable to the different sample preparation methods necessary. The working range for the HPTLC method was between 0.1 and 8.2 micrograms/ml and for the HPLC method between 0.2 and 60.0 micrograms/ml. The method standard deviations were 2.66-4.91% (HPTLC) and 0.48-3.67% (HPLC).

3,4-Methylenedioxyamphetamine↗