PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Transmission of change in the atmospheric pressure of the external ear to the perilymph.

In experiments using guinea pigs, the middle ear and perilymphatic pressures were simultaneously registered in response to pressure change in the external ear canal. In the first experiment, pressure was slowly loaded in the ear canal in the range of 200 mm H2O to -200 mm H2O. Pressure transmission to the perilymph was smaller when the bulla was open to the outside than when it was closed. It was significantly impaired by disruption of the ossicular chain and especially by closure of the round window. The data indicate that air volume in the middle ear cavity plays an important role in transmission of slowly changing atmospheric pressures. In the second experiment, the eustachian tube was closed and the pressure was changed in the range of 1000 mm H2O to -1000 mm H2O. The middle ear and perilymphatic pressures increased or decreased corresponding to the loading pressure in the range of 400 mm H2O and -200 mm H2O. Beyond these levels, response rate of the middle ear pressure decreased and perilymphatic pressure declined in spite of further increase in loading pressure. The increase in pressure difference between the middle ear and the inner ear might cause disruption of the round and/or oval windows.

Animals↗

The significance of low atmospheric pressure on the eyes with reference to soft contact lenses.

Many aircraft passengers wearing contact lenses have complained about visual disturbances, tearing and smarting of the eyes. This kind of discomfort has been named jet-set disease. The literature on this subject has been reviewed. Also my own study is reported. In that study seven test persons were examined during four hours in a decompression chamber. The atmospheric pressure was lowered to 560 millibars , which corresponds to an altitude of 4,000 metres. All test persons wore soft contact lenses. Objective symptoms were verified in four eyes after one hour and in all 14 eyes after three hours. The most serious objective findings were corneal erosions in 4 and opacities of corneal stroma in 10 eyes. The two investigators who did not wear contact lenses remained without both subjective and objective symptoms.

Aircraft↗

Determination of methocarbamol in equine serum and urine by high-performance liquid chromatography with ultraviolet detection and atmospheric pressure ionization-mass spectrometric confirmation.

Urine and serum samples collected from four standard-bred mares after and oral regimen administration of methocarbamol were extracted and analyzed. The method consisted of enzyme hydrolysis followed by a one-step liquid-liquid extraction, separation on a reversed-phase (RP-18) column, and detection using an ultraviolet (UV) detector. The confirmation was carried out using a liquid chromatography-atmospheric pressure ionization-mass spectrometry (LC-API-MS) system. Maximum methocarbamol concentrations of 1498, 1734, 1547, 2322 micrograms/mL in urine and 4.9, 1.7, and 3.6 micrograms/mL in serum were observed. The peak concentrations of the drug were detected 1-4 h (urine) and 10-60 min (serum) after administration to four horses. The method validation results and drug elimination profiles for both urine and serum are presented and discussed.

Animals↗

Bacillus subtilis spore survival and expression of germination-induced bioluminescence after prolonged incubation under simulated Mars atmospheric pressure and composition: implications for planetary protection and lithopanspermia.

Bacterial endospores in the genus Bacillus are considered good models for studying interplanetary transfer of microbes by natural or human processes. Although spore survival during transfer itself has been the subject of considerable study, the fate of spores in extraterrestrial environments has received less attention. In this report we subjected spores of a strain of Bacillus subtilis, containing luciferase resulting from expression of an sspB-luxAB gene fusion, to simulated martian atmospheric pressure (7-18 mbar) and composition (100% CO(2)) for up to 19 days in a Mars simulation chamber. We report here that survival was similar between spores exposed to Earth conditions and spores exposed up to 19 days to simulated martian conditions. However, germination-induced bioluminescence was lower in spores exposed to simulated martian atmosphere, which suggests sublethal impairment of some endogenous spore germination processes.

Atmospheric Pressure↗

Separation and identification of perchlorinated polycyclic aromatic hydrocarbons and fullerenes (C60, C70) by coupling high-performance liquid chromatography with ultraviolet absorption spectroscopy and atmospheric pressure chemical ionization mass spectrometry.

Simultaneous separation and identification of perchlorinated polycyclic aromatic hydrocarbons (PCPAHs) and fullerenes is of practical interest due to the growth mechanism of fullerenes involved with PCPAHs. Non-aqueous reversed-phase high-performance liquid chromatography (HPLC), with an ODS column and a gradient mobile phase of methanol-ethanol-cyclohexane mixtures, was combined with both rapid-scan ultraviolet spectrometry (UV) and atmospheric pressure chemical ionization mass spectrometry (APCI-MS) for the separation and identification of over 80 PCPAHs as well as fullerenes C60 and C70, that were synthesized in the discharge reaction of chloroform. PCPAH retention was found to depend on the number of aromatic rings and the degree of non-planarity of PCPAH structure. Based on the isotopic pattern of molecular ion or/and quasi-molecular ion peaks in corresponding mass spectra, molecular compositions of the PCPAH products were unambiguously determined. The results obtained from the HPLC-UV-MS analysis not only are helpful for the understanding of the fullerenes formation mechanism, but also contribute to the analytical technique capable of separating and identifying the complicated mixture of PCPAHs and fullerenes.

Atmospheric Pressure↗

Liquid chromatography-atmospheric pressure chemical ionisation/mass spectrometry: a rapid and selective method for the quantitative determination of ginkgolides and bilobalide in ginkgo leaf extracts and phytopharmaceuticals.

In order to evaluate the composition of active constituents in phytopharmaceutical preparations, valid analytical methods are required. For the determination of the active terpene constituents of Ginkgo biloba (the ginkgolides and bilobalide), a liquid chromatography-mass spectrometry (LC-MS) method has been developed using atmospheric pressure chemical ionisation (APCI) in the negative ion mode. This detection mode was found to be much more sensitive and selective compared to UV; indeed the ginkgo terpene trilactones lack strong UV chromophores and flavonoids interfere with their UV detection. LC-APCI/MS detection allowed a considerable reduction in analysis time when compared to LC-UV, because LC resolution was only needed between the pair of isomers ginkgolide B and ginkgolide J. All compounds were selectively detected by single ion monitoring of their specific deprotonated molecules [M-H]-. The samples were directly injected without pre-purification, and a fast gradient was applied, reducing the total time of analysis to 14 min. With this method, the ginkgo terpene trilactones were detected on-line in the picogram range. Several commercial ginkgo preparations on the Swiss market were analysed, and the ginkgolide and bilobalide contents were evaluated using the method described.

Atmospheric Pressure↗

Qualitative analysis of some carboxylic acids by ion-exclusion chromatography with atmospheric pressure chemical ionization mass spectrometric detection.

A simple, selective and sensitive method for the determination of carboxylic acids has been developed. A mixture of formic, acetic, propionic, valeric, isovaleric, isobutyric, and isocaproic acids has been separated on a polymethacrylate-based weak acidic cation-exchange resin (TSK gel OA pak-A) based on an ion-exclusion chromatographic mechanism with detection using UV-photodiode array, conductivity and atmospheric pressure chemical ionization mass spectrometry (APCI-MS). A mobile phase consisting of 0.85 mM benzoic acid in 10% aqueous methanol (pH 3.89) was used to separate the above carboxylic acids in about 40 min. For LC-MS, the APCI interface was used in the negative ionization mode. Linear plots of peak area versus concentration were obtained over the range 1-30 mM (r2=0.9982) and 1-30 mM (r2=0.9958) for conductimetric and MS detection, respectively. The detection limits of the target carboxylic acids calculated at S/N=3 ranged from 0.078 to 2.3 microM for conductimetric and photometric detection and from 0.66 to 3.82 microM for ion-exclusion chromatography-APCI-MS. The reproducibility of retention times was 0.12-0.16% relative standard deviation for ion-exclusion chromatography and 1.21-2.5% for ion-exclusion chromatography-APCI-MS. The method was applied to the determination of carboxylic acids in red wine, white wine, apple vinegar, and Japanese rice wine.

Atmospheric Pressure↗

Liquid chromatographic-atmospheric pressure chemical ionization mass spectrometric analysis of opiates and metabolites in rat urine after inhalation of opium.

To examine the urinary excretion of opiates and their metabolites following inhalation exposure of rats to opium, analytical procedures for the simultaneous determination of the compounds in opium, the vapor derived by the volatilization of opium and the urine of rats exposed to the opium vapor were developed using liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS). Seven compounds were determined in the opium, namely morphine, codeine, thebaine, noscapine, papaverine, meconic acid and meconin. All seven were extracted with 2.5% acetic acid solution and subjected to LC-APCI-MS analysis. The separation was performed on an ODS column in acetonitrile-50 mM ammonium formate buffer (pH 3.0) using a linear gradient program and quantitative analysis was carried out in the selected ion monitoring mode ([M+H](+)). For the analysis of the volatilization of opium, the opium (1 g) was added to a glass pipe, which was then heated at 300 degrees C for 20 min. Negative pressure (air flow-rate; 300 ml/min) was used to draw the vapor through a series of glass wool and methanol traps. The total amount of each compound in the vapor was estimated by measurement of the compounds trapped in the glass wool and methanol. Wister rats (n=3) were exposed to the vapor derived from the volatilization system and the urinary amounts (0-72 h) of the six opiates and metabolites including morphine-3-grucronide (M3G) and morphine-6-grucronide (M6G) were measured after solid-phase extraction. The calibration curves for those compounds in the rat urine were linear over the concentration range 10-500 ng/ml. The recoveries for each analyte from the rat urine sample spiked with standard solution were generally greater than 80%, and the relative standard deviation for the analytical procedure was less than 8% with the exception of meconin. After inhalation exposure of rats to opium, M3G (5.45-14.38 micro g), morphine (2.27-4.65 micro g), meconin (0.54-1.85 micro g), codeine (0.54-1.85 micro g), noscapine (0.34-0.40 micro g) and papaverine (0.01-0.04 micro g) were detected in the urine over 72 h. However, only trace levels of thebaine were observed despite it being one of the major alkaloids found in the opium. On the other hand, a relatively large amount of meconin was detected in the vapor and the urine as compared with the opium. It is suggested that the presence of meconin in biological fluids could be indicative of opium ingestion by inhalation.

Administration, Inhalation↗

Universal screening method for the determination of US Environmental Protection Agency phenols at the lower ng l(-1) level in water samples by on-line solid-phase extraction-high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry within a single run.

The applicability of a previously optimized method for the analysis of the US Environmental Protection Agency (EPA) regulations phenols, based on on-line solid-phase extraction coupled to liquid chromatography with mass spectrometric (MS) detection in different matrix loaded water samples is demonstrated. The comprehensive optimization of the mobile phase conditions and their influence on the ionization process in atmospheric pressure ionization is described in detail. In particular, MS detection of the weakly acidic phenols such as phenol, monochlorinated phenols and methylated phenols requires the absence of acidic mobile phase modifiers and buffers. Thus lower retention times and slight peak broadening of the more acidic dinitrophenols are obtained if the entire range of EPA phenols is analyzed within a single chromatographic run. The figures of merit for the method were determined and the applicability to real water samples was investigated. Limits of detection for phenols ranging from 40 to 280 ng l(-1) and relative standard deviations below 8% in SCAN mode are obtained for all phenols if only 10-ml river water samples with low dissolved organic carbon (DOC 5 mg C l(-1) concentrations are preconcentrated. The method was used to detect 2-nitrophenol and 4-nitrophenol in river water samples in the lower ng l(-1) range. The analysis of highly matrix-loaded samples (DOC 210 mg C l(-1)) requires a reduced enrichment volume resulting in decreased sensitivity. Still the method is capable of reaching excellent detection limits which demonstrates its excellent suitability for screening analysis.

Atmospheric Pressure↗

Identification of complex mixtures of sphingolipids in the stratum corneum by reversed-phase high-performance liquid chromatography and atmospheric pressure photospray ionization mass spectrometry.

Sphingolipids, such as ceramides and cerebrosides, are important molecules in the formation and maintenance of the epidermal barrier to water vapor diffusion. In this paper we explore a new method to identify the sphingolipids found in the stratum corneum (SC), the outer layer of the epidermis, of House sparrows living in Saudi Arabia using reversed-phase high-performance liquid chromatography (HPLC) coupled with atmospheric pressure photo-ionization mass spectrometry (APPI-MS). First, using thin layer chromatography (TLC) we found that the SC contains ceramides, cerebrosides, and free fatty acids along with smaller amounts of cholesterol. Knowing the classes of sphingolipids present in the SC markedly reduced the number of possible molecules present. Then, we identified each sphingolipid molecule in our sample by both negative and positive mode of APPI-MS. We confirmed our identifications by generation of accurate mass data, and by examination of MS/MS spectra for selected molecules. Using APPI-MS, we identified 7 families of cerebrosides, for a total of 97 molecular species, and 4 families of ceramides, for a total of 79 molecules, in the SC of House sparrows, a wider array than would be found in mammals. Carbon chain lengths of fatty acids in the sphingolipids were longer than those that have been reported for mammalian SC; chain lengths of over 40 carbons were common. We also compared our estimates of the quantity of lipids in the SC obtained by HPLC/MS with those from TLC. Estimates of the amount of total ceramides and cerebrosides using TLC differed from those obtained by HPLC/MS by +0.95% and -2.5%, respectively. We conclude that our protocol using reversed-phase HPLC and APPI-MS is an useful method of analyzing complex mixtures of sphingolipids in the SC.

Animals↗

Products of the reaction between alpha- or gamma-tocopherol and nitrogen oxides analyzed by high-performance liquid chromatography with UV-visible and atmospheric pressure chemical ionization mass spectrometric detection.

The reaction products of alpha- or gamma-tocopherol with nitric oxide in the presence of molecular oxygen were isolated and characterized. The consumption of tocopherols and the formation of the major products were monitored by high-performance liquid chromatography (HPLC) by a gradient elution method. The quantitative analysis of these compounds with UV-Vis detectors, however, was interfered by several minor products having similar UV spectra and retention times as those of the major ones. In order to establish a quantitative analytical method for the products, we investigated other detection methods, and found that atmospheric pressure chemical ionization (APCI), LC-MS was a more selective and better analytical method for these compounds.

Atmospheric Pressure↗

Atmospheric pressure chemical ionization mass spectrometry of aldehydes in biological matrices.

Application of high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) for detection of aldehydes in biological samples such as blood, yoghurt, and milk, is reported. Sample preparation is easy, and the presented method is both sensitive and selective. It is based on the widely used dinitrophenylhydrazine derivatization, followed by extraction with n-hexane and a simple reversed-phase HPLC separation. Detection is performed by atmospheric pressure chemical ionization (APCI) in negative ion mode, with detection limits in the low picogram range. Using MS/MS, acetone and propionaldehyde can clearly be distinguished, facilitating propionaldehyde quantitation even in the presence of high acetone levels. Quantitation by direct MS/MS is also feasible, well suited for high-throughput applications, although not as accurate as using HPLC/MS/MS.

Aldehydes↗

Characterization of the atmospheric pressure ionization mass spectrometric process obtained using a fused-silica emitter with the high voltage applied upstream

The atmospheric pressure ionization process obtained when a mixture of methanol and water (90:10, v/v) also containing 50 microM sodium hydroxide is dispersed from a fused-silica emitter was studied. A combination of a high electric field and a nebulizer gas with the high voltage applied upstream in the liquid flow was utilized to facilitate the spray process. By comparing the dependences of the spray current and ion signals on the spray potential, it was found that electrical corona discharges were obtained for potentials higher than about 2.6 kV, which resulted in a mixed electrospray and chemical ionization process. By introducing vapour from a solvent, such as benzene or toluene, with a low ionization energy into the nebulizing gas, it was found that the appearance of the corresponding molecular ion was correlated with a change in the slope of the spray current-potential curve. This indicates that the breakpoints in the spray current-potential curves observed were correlated with the onsets of corona discharges. It was shown that the mixed ionization process gives rise to increased amounts of protonated solvent molecules and assists in the formation of sodiated adduct ions from an uncharged fatty acid methyl ester.

Journal Article↗

The use of liquid chromatography-atmospheric pressure chemical ionization mass spectrometry to explore the in vitro metabolism of cyanoalkyl piperidine derivatives.

A LC/MS method using atmospheric pressure chemical ionization, positive ion mode and full scan to measure the in vitro metabolic stability of cyanoalkyl functionalized compounds with the human liver microsomes was employed. Percentage metabolism examined for the five cyanoalkyl piperidines revealed the optimal chain length and positioning of these functions to produce the most metabolically stable compound. The 4-cyanomethyl piperidine derivative was the most stable compound with 15% metabolism after 15 min incubation with human liver microsomes. In general, the major metabolites formed from the cyanoalkyl piperidine derivatives were due to oxidation of the cyanoalkyl chain or the piperidine fragment, resulting in a M+16 ion. However, the 2-cyanomethyl piperidine derivative exhibited an interesting biotransformation pathway with unusual metabolite peaks corresponding to M+5, M-11 and M+21 ions. Data-dependent MS/MS scanning was used to generate daughter ion spectra from the parent compound and its metabolite peaks. Based on the fragmentation analysis, a carboxylic acid, aldehyde and oxidative metabolite of the carboxylic acid structure have been proposed for M+5, M-11 and M+21 ions, respectively.

Chromatography, Liquid↗

Picogram determination of finasteride in human plasma and semen by high-performance liquid chromatography with atmospheric-pressure chemical-ionization tandem mass spectrometry.

A method based on high-performance liquid chromatography (HPLC) with atmospheric-pressure positive-ion chemical ionization (APCI)-tandem mass spectrometric (MS-MS) detection for the determination of finasteride (MK-906, I) in human plasma and semen has been developed. The drug and internal standard (II) were extracted from biological matrices using a single solid-phase cyano cartridge. The eluent from the cartridge was injected directly onto the a 33 x 4.6 mm I.D. C18, 3-microns column coupled with a base deactivated C18 20 x 4.6 mm I.D., 5-microns guard column. The column eluate was passed into the corona discharge APCI source by means of a heated nebulizer interface. The analyte and its internal standard were detected using multiple reaction monitoring (MRM) mode for enhanced selectivity and sensitivity. The chromatographic run time was 3 min, and the method had sufficient sensitivity, precision, accuracy and selectivity for the analysis of clinical samples containing finasteride at concentration of 0.2 ng/ml. The assay methodology confirms the versatility of APCI-MS-MS detection, combined with HPLC, for the quantitation of selected drugs in the sub-ng/ml range in biological fluids.

Chromatography, High Pressure Liquid↗

Fragmentation of phosphopeptides by atmospheric pressure MALDI and ESI/Ion trap mass spectrometry.

An investigation of phosphate loss from phosphopeptide ions was conducted, using both atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) and electrospray ionization (ESI) coupled to an ion trap mass spectrometer (ITMS). These experiments were carried out on a number of phosphorylated peptides in order to investigate gas phase dephosphorylation patterns associated with phosphoserine, phosphothreonine, and phosphotyrosine residues. In particular, we explored the fragmentation patterns of phosphotyrosine containing peptides, which experience a loss of 98 Da under collision induced dissociation (CID) conditions in the ITMS. The loss of 98 Da is unexpected for phosphotyrosine, given the structure of its side chain. The fragmentation of phosphoserine and phosphothreonine containing peptides was also investigated. While phosphoserine and phosphothreonine residues undergo a loss of 98 Da under CID conditions regardless of peptide amino acid composition, phosphate loss from phosphotyrosine residues seems to be dependent on the presence of arginine or lysine residues in the peptide sequence.

Amino Acids↗

The analysis of beta-agonists by packed-column supercritical fluid chromatography with ultra-violet and atmospheric pressure chemical ionisation mass spectrometric detection.

Packed-column supercritical fluid chromatography (pSFC) using ultra-violet (UV) and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS) provides a versatile method for the identification and quantification of beta-agonists. We have achieved good separation of clenbuterol, salbutamol, terbutaline and fenoterol with good resolution and reasonable retention times using a high concentration of methanol modifier in the supercritical CO2, together with small amounts of both acidic (trifluoroacetic acid, TFAA) and basic (triethylamine, TEA, or diethylamine, DEA) additives. APCI-MS gave unambiguous identification of the 4 analytes, and increasing cone voltage provided informative fragmentation patterns. The pSFC-MS technique was shown to be linear (R2 > or = 0.996) over the concentration range 1-50 micrograms ml-1. Single ion monitoring (SIM) gave detection limits (on-column) of 2.5 ng (clenbuterol), 0.83 ng (terbutaline), 7.6 ng (salbutamol) and 2.7 ng (fenoterol). The pSFC-MS system was shown to be reproducible within a day, between days, and between restrictors. Analysis of milk samples 'spiked' with beta-agonists showed that the matrix caused no interference, with detection limits of approximately 500 micrograms l-1 of beta-agonists. More dilute solutions could be analysed by pre-concentration before the SFC stage.

Adrenergic beta-Agonists↗

Analysis of pharmaceutical formulations using atmospheric pressure ion mobility spectrometry combined with liquid chromatography and nano-electrospray ionisation.

The hyphenation of liquid chromatography with atmospheric pressure ion mobility spectrometry is reported using a custom-made dynamic nano-electrospray ionisation (nano-ESI) interface. The analysis of pharmaceutical actives is described, including beta blocker (timolol), antidepressant (paroxetine), analgesic (paracetamol) and opiate (codeine) preparations. On-line ultraviolet diode array (UV) spectroscopic detection was used prior to sample ionisation, to evaluate chromatographic and nano-ESI interface performance. Active drug responses were characterised by chromatographic retention time and electrophoretic ion mobility drift time, and selected ion mobility responses were used to evaluate method performance. Limits of detection for active drugs were in the low-nmol to pmol range. Quantitative responses were investigated using a series of standard solutions of caffeine, showing good linearity (R(2) = 0.9982, n = 6) and reproducibility (RSD = 2.3 %, n = 6). The analysis of an over the counter pharmaceutical formulation demonstrates the potential of ion mobility spectrometry combined with liquid chromatography and nano-electrospray ionisation for the rapid determination of active drugs, as a result of the electrophoretic separation and selectivity afforded by IMS.

Chromatography, Liquid↗