Intravenous digital subtraction angiography in the preoperative evaluation of renal masses.

Intravenous digital subtraction angiography (DSA) was performed in 23 patients with renal masses to document tumor extension into the main renal vein or inferior vena cava. The DSA findings were compared with computed tomographic as well as surgical and pathologic findings. Additional data regarding the number of renal arteries present and the relative vascularity of the tumor were also gathered. DSA documented 17 true-negative renal veins, three true-positive renal veins, and one false-negative renal vein. Two patients could not hold their breath long enough to evaluate the renal vein. In 17 of 19 cases, single renal arteries to the affected kidney were correctly identified. In three patients, two renal arteries to the involved kidney were correctly identified. The renal masses were avascular in two patients, hypovascular in five, moderately vascular in eight, and hypervascular in seven. In one case the mass was out of the field of view, and vascularity was not evaluated. In these patients, DSA was an accurate and relatively noninvasive method to assist in the preoperative evaluation of renal masses.

Adenocarcinoma↗

Digital subtraction angiography in Takayasu arteritis.

The usefulness and limitation of digital subtraction angiography (DSA) in Takayasu arteritis were investigated in 32 patients. Intravenous DSA was particularly useful in the follow-up of patients with an established diagnosis of Takayasu arteritis. Pulmonary arterial involvement could also be demonstrated with intravenous DSA as obstructive arterial changes and lack of accumulation of contrast medium in the pulmonary parenchyma. Detailed information concerning the site and extent of vascular involvement and development of collateral vessels were obtained with intraarterial DSA. Thickening of the thoracic aortic wall, however, could not be recognized with either intravenous or intraarterial DSA. Conventional angiography of the descending thoracic aortal is still required as an initial examination, particularly when there is no aortic arch involvement. However, there is no doubt that DSA has the potential to become the diagnostic procedure of choice in Takayasu arteritis.

Adolescent↗

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system.

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

Adult↗

[Visualization of enlarged parathyroids by digital subtraction angiography in 22 patients with primary or secondary hyperparathyroidism].

Digital Subtraction Angiography (DSA) is a suitable method for visualising hypercrinal parathyroid glands on account of its high power of resolution. Hyperperfused areas stand out in contrast when using largely standardised imaging techniques with peripheral venous injection of contrast medium. Whereas 15 of 17 hyperplastic parathyroids were seen via DSA, it was not possible to identify on the subtraction image 2 out of 6 adenomas and one carcinoma. In our group of patients, surgical confirmation was obtained in 21 of 32 hyperperfused areas found via DSA (66%) and 9 out of 17 structures with poor echo (53%) in ultrasound.

Adult↗

Intraarterial digital subtraction angiography of peripheral arteries with isotonic contrast material.

Intraarterial digital subtraction angiography (IADSA) of peripheral arteries with isotonic contrast material, which was prepared by diluting meglumine amidotrizoate (65% Angiografin), was performed in ten patients. In six, both IADSA and conventional screen-film arteriography were performed for comparison. Painless peripheral arteriography was achieved by IADSA with isotonic contrast material. Five IADSAs were safely done on an outpatient basis. Visualization of arteries by IADSA was satisfactory, but the details of smaller arteries were better shown by screen-film arteriography. Visualization of faint stains was better in IADSA. The authors believe that IADSA with isotonic contrast material is a method of choice for the diagnosis of vascular diseases and tumorous conditions of extremities, as well as for the purpose of preoperative vascular mapping. It is safely performed with smaller dose of contrast material on outpatient basis, and with less discomfort and cost for the patient.

Angiography↗

Radiation exposure from conventional and digital subtraction angiography of cerebral vessels.

Patients with atherosclerotic cerebrovascular disease were studied to determine the radiation exposure associated with conventional and digital subtraction angiography of the cerebral vessels. The median exposure-area product was 3198 R cm2 (range, 616-5665 R cm2) in the conventional angiography group and 1831 R cm2 (range, 366-4198 R cm2) in the IV digital subtraction angiography (DSA) group. This difference in exposure resulted from increased use of fluoroscopy in the conventional screen-film angiography group. The actual difference in exposure between the radiographic and digital imaging portions of the examinations was much smaller. The contributions of fluoroscopy to the radiation exposure in conventional angiography and IV-DSA in this study were 37% (range, 8.8-76%) and 6% (range, 1.5-25%), respectively.

Cerebral Angiography↗

[Assessment of coronary hemodynamics and myocardial perfusion in patients with syndrome X by digital subtraction angiography and 201Tl-myocardial scintigraphy].

To evaluate coronary hemodynamics and myocardial perfusion, left coronary digital subtraction angiography (DSA) and Tl-201 myocardial scintigraphy were performed in patients with syndrome X. The coronary circulation time (CCT) was significantly prolonged after the injection of isosorbide dinitrate and contrast medium i.c. Apical T1/2 was also prolonged on ergonovine malate provocation test. We suspected that the vascular response of the coronary peripheral artery was impaired, and microvascular spasm probably existed in patients with syndrome X. The prevalence of abnormal myocardial perfusion defect on exercise Tl-201 SPECT in syndrome X was very high, and coronary hemodynamics was significantly disturbed in the group of syndrome X with abnormal Tl-201 SPECT. Tl-201 lung/heart count ratio significantly increased in syndrome X on treadmill test. Because of this, exercise induced left ventricular dysfunction was suspected. We concluded that the main pathophysiological finding of impaired coronary circulation in syndrome X was microvascular spasm.

Angiography, Digital Subtraction↗

[Digital subtraction angiography with carbon dioxide using a new gas dosage system].

PURPOSE: The clinical evaluation of digital subtraction angiography with carbon dioxide using a newly developed low-tech CO2 dosage and injection system. METHOD AND PATIENTS: The hand-held system (CO2 angio set) consists of a dosage chamber in connection with a special stopcock to apportion the gas. By optimising injection volume and pressure steady gas flow characteristics are approximated. A safety design prevents unintentional gas injection. CO2 arteriographies were performed on 185 patients. Main indications were renal insufficiency and a history of adverse reactions to iodinated contrast media. In patients with femoral cannula access, catheterless reflux angiography was performed. RESULTS: The injection system provided complete and coherent visualisation of the abdominal aorta, visceral, pelvic, and lower limb arteries via catheter (71 cases) or via femoral cannula using reflux technique (114 cases). Stenoses, occlusions, and collaterals were assessable. Employing the gas reflux over the aortic bifurcation bilateral run-off studies up to the calf trifurcation were performed via unilateral femoral cannula. Use of a dedicated stacking software improved image quality of distal femoral, popliteal and calf arteries. CONCLUSION: The CO2 management system allows adequate imaging of the arteries below the diaphragm. Ease and safety of use and low costs are advantageous.

Angiography, Digital Subtraction↗

Usefulness of 3-dimensional reconstructed images of renal arteries using rotational digital subtraction angiography.

PURPOSE: We assess the feasibility of a 3-dimensional (D) reconstruction technique of rotational digital subtraction angiography (DSA) for visualization of the renal arteries. MATERIALS AND METHODS: We evaluated 28 kidneys in 20 patients. Rotational DSA images were obtained during a deep inspiratory pause after contrast material injection through the renal artery. Acquired data were transferred to an image workstation and reconstructed as 3-D images. Visibility of the main trunk of the renal artery, segmental arteries, interlobar arteries and arcuate arteries was classified as grade 4-excellent, grade 3-good, grade 2-satisfactory and grade 1-poor. The 3-D reconstructed images were compared with conventional 2-D DSA performed just before the rotational DSA. The criteria for evaluation were visibility of the aneurysm neck in 8 cases of aneurysm, delineation of the feeding arteries in 6 cases of renal lesions and visibility of the relationship between renal branches in other cases. RESULTS: Delineation of grades 4 to 1 was 93%, 7%, 0% and 0% for the main renal artery, 66%, 21%, 7% and 6% for segmental arteries, 61%, 11%, 21% and 7% for interlobar arteries, and 36%, 18%, 36% and 10% for arcuate arteries, respectively. The 3-D images had the advantage over 2-D DSA in 75% of cases. In all cases of aneurysm 3-D images were obviously more useful than 2-D DSA. CONCLUSIONS: 3-D images of renal arteries obtained with rotational DSA are considered acceptable for clinical use.

Adolescent↗

Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment.

PURPOSE: To evaluate three-dimensional (3D) digital subtraction angiography (DSA) as a supplement to two-dimensional (2D) DSA in the endovascular treatment (EVT) of intracranial aneurysms. MATERIALS AND METHODS: In 22 ruptured aneurysms, neck visualization, aneurysm shape, and EVT feasibility were analyzed at 2D DSA (anteroposterior, lateral, and rotational views) and at maximum intensity projection (MIP) and surface shaded display (SSD) 3D DSA. The possibility of obtaining a working view for EVT at 3D DSA and the relevance of measurements in choosing the first coil also were assessed. RESULTS: Two-dimensional DSA images clearly depicted the aneurysm neck in four of 22 aneurysms; MIP images, in 10; and SSD images, in 21, but SSD led to overestimation of the neck size in one aneurysm. Aneurysm shape was precisely demonstrated in five of 22 aneurysms at 2D DSA, in eight at MIP, and in all cases at SSD. In two of 22 aneurysms, EVT seemed to be nonfeasible at 2D DSA; however, SSD demonstrated feasibility and EVT was successfully performed. In one aneurysm, only SSD demonstrated the extension of the neck to a parent vessel, which was proved at surgery. Working views for EVT were deduced from 3D DSA findings in 20 of 21 aneurysms. The choice of the first coil was correct in 19 of 21 aneurysms. CONCLUSION: Three-dimensional DSA is valuable for evaluating the potential for EVT, finding a working view, and performing accurate measurements.

Adult↗

Stereotactic radiosurgery for brain AVMs: role of interobserver variation in target definition on digital subtraction angiography.

PURPOSE: We evaluated the extent of interobserver variation in contouring arteriovenous malformations (AVMs) on digital subtraction angiography (DSA) with respect to volume, spatial localization, and dosimetry and correlated our findings with the clinical outcome. METHODS AND MATERIALS: Thirty-one patients who had undergone radiosurgery for brain AVMs were studied. Six clinicians independently contoured the nidus on the original DSA. As a measure of variation, the ratio between the volumes of agreement and the corresponding encompassing volumes, as well as the absolute positional shift between the individual target volumes were derived. Using the original treatment plan, the dosimetric coverage of the individually contoured volumes with standard collimators was compared with a similar plan using dynamic conformal arcs. RESULTS: The mean contoured nidus volume was 3.6 +/- 5.6 cm3. The mean agreement ratio was 0.45 +/- 0.18 for all possible pairs of observers. The mean absolute positional shift between individually contoured volumes was 2.8 +/- 2.6 mm. These differences were more marked in previously treated groups and tended to be more pronounced in those with treatment failure. The mean coverage of the individual volumes by the 80% prescription isodose was 88.1% +/- 3.2% using conventional collimators and 78.9% +/- 4.4% using dynamic conformal arcs (p = 0.001). CONCLUSION: Substantial interobserver variations exist when contouring brain AVMs on DSA for the purpose of radiosurgical planning. Such variations may result in underdosage to the AVM and, thereby, contribute to treatment failure. The consequences of contouring variations may increase with the use of more conformal radiosurgical techniques.

Adolescent↗

CO2 digital subtraction angiography for renal artery angioplasty in high-risk patients.

OBJECTIVE: The efficacy of CO2 digital subtraction angiography for performing renal artery angioplasty in high-risk patients was evaluated. SUBJECTS AND METHODS: From January 1997 to July 1998, 21 high-risk patients underwent 29 renal artery angioplasties using carbon dioxide as the principal contrast agent. Six patients had a known allergy to iodinated contrast material and 15 had elevated levels of creatinine. Iodinated contrast material was used only if necessary. All periprocedural allergic reactions were recorded. Before and 24 hr after the procedure, serum creatinine levels were obtained. If the creatinine level had become significantly elevated (>0.5 mg/dl), the creatinine level was acquired a second time. RESULTS: Twenty-one patients (13 men and eight women) underwent 29 angioplasties (two were bilateral and six were repeated). Four kidney transplantation patients had ostial stenosis and the remaining 17 patients had nonostial stenosis. For all patients except one angioplasty initially was a technical success, as defined by a residual stenosis of less than 30%. Supplemental iodinated contrast material was used in only six patients (average dose, 8.5 ml). A range of 80-200 ml of carbon dioxide per procedure was used (average dose, 114.6 ml). One renal artery dissection occurred, which was unrelated to the carbon dioxide. There were no allergic reactions. The level of serum creatinine remained the same after 11 procedures, decreased after 12 procedures, and increased minimally after four procedures (<0.5 mg/dl). CONCLUSION: On the basis of our preliminary findings in a small group of patients, using carbon dioxide as an intravascular contrast agent to perform renal artery angioplasty in patients who have an allergy to iodinated contrast material or who suffer from renal insufficiency is safe and efficacious.

Adult↗

Clinical experience with stereotactic digital subtraction angiography with distortion correction software.

Recently developed software for correction of the geometric distortion in digital subtraction angiography was tested clinically. Localization and subsequent radiosurgical treatment of intracranial arteriovenous malformations was undertaken in 60 patients. During each angiographic series, a series of grid images was also acquired. All images were transferred to a workstation where the grid images were compared to a previously stored ideal image of the grid. A distortion correction was then performed on the grid images. The same pixel-by-pixel correction was applied to the respective angiographic images. The target was outlined on corrected subtracted images on the monitor. The outlined regions of interest and reference points were transferred to another workstation for dose planning, and the treatment was subsequently executed in the Gamma Knife unit. The clinical applicability of the distortion correction program was tested and possible sources of error examined. The experience gained is being used for further development of the software and for smoother data management and reduction of the processing time.

Adolescent↗

Morphological and hemodynamic assessments of carotid stenosis using quantitative digital subtraction angiography.

BACKGROUND AND PURPOSE: Digital angiography is the best established tool for assessing atheromatous disease of extracranial blood vessels. Advances in computer technology have now made it possible and practicable to extract quantitative information (length, width, cross-sectional area, and flow velocity) from good-quality clinical angiograms, allowing calculation of volume flow and pressure gradient. The technique of quantitative angiography (QA) is used for assessing coronary artery disease, but to date there has been no clinical application in patients with cerebrovascular disease. SUMMARY OF REPORT: We have developed a computer program for off-line analysis of routine digital subtraction angiographic images. From biplanar images, the program reconstructs the angiogram in three dimensions and performs quantitative analysis of each vessel. From this data, the pressure drop from the aortic arch to the circle of Willis is then calculated. We assessed the clinical applicability of QA in five patients investigated for transient ischemic attack. The carotid artery ipsilateral to the symptomatic hemisphere was occluded in one patient and had minor plaque in another. In the remaining three patients, ipsilateral internal carotid artery stenosis was measured by QA as producing area reductions of 55%, 72%, and 88% (equivalent to diameter reductions of 33%, 48%, and 65%, respectively). In these patients, the quantitative stenosis pressure gradients were calculated as 1.2, 3.0, and 3.5 mm Hg. respectively. Further calculation showed that each stenosis contributed to 18%, 24%, and 60%, respectively, of the total carotid pressure gradient from the aortic arch to the circle of Willis. These carotid arteries carried 47%, 42%, and 26%, respectively, of the total cerebral flow. The results of quantitative analysis were validated by comparing, within each patient, the differences in pressure gradients between right and left carotid systems of between right and left vertebral arteries (overall mean difference in pressure gradient, 0.6 +/- 0.5 mm Hg: P = NS). Finally, comparison was made of pressure gradients across the circle of Willis between the carotid and vertebrobasilar circulations (mean difference in pressure gradient, 4.1 +/- 5.3 mm Hg; P = NS). CONCLUSIONS: Quantitative angiography allows determination of the hemodynamic parameters of a vessel or stenosis. It has significant potential, both as a research tool and in routine clinical practice, for the investigation of cerebrovascular disease.

Angiography, Digital Subtraction↗

[Quantitative determination of cerebral perfusion using digital subtraction angiography (DSA)].

In a search for a reliable and relatively non-invasive method for quantifying cerebral perfusion, we examined the possible role of DSA. By using special software, it is possible to demonstrate vascular morphology and obtain functional data concerning blood flow. Regions of interest are used for obtaining time-density curves and these are evaluated by a formula designed by Meier and Zierler. Perfusion through the arterial territory in both cerebral hemispheres was correlated with the clinical symptoms of the patients and with the morphological findings. Difficulties and problems are described and discussed.

Angiography, Digital Subtraction↗

[Necessity for ECG triggering in digital subtraction angiography. Construction of a simple trigger device].

Movement unsharpness during digital subtraction angiography of the aortic arch and supra-aortic vessels can be avoided by means of ECG gating. The usual techniques resulted in exposures during the phase of least cardiac movement. The relatively long exposure time of about 60 to 300 msec caused marginal blurring during the exposure. An ECG-triggered device is described which produces short exposure times for the mask and filled frame during identical cardiac phases. An example with and without ECG gating shows marked improvement in detail rendering. The design of an ECG-triggered device with digitally adjustable delay and freedom from interference is described.

Angiography↗