PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROPHORESIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Inhibition of precipitation in counter current electrophoresis. A sensitive method for detection of mink antibodies to Aleutian disease virus.

Inhibition of precipitation in counter current electrophoresis was at least 32 more sensitive when compared to the normal counter current electrophoresis for the demonstration of mink antibodies against Aleutian disease virus (ADV). ADV antigen can be produced from mink organs or in cell culture. The reactivity of the two types of antigen in the two kinds of counter current electrophoresis methods is described in this report. When 22 mink sera were titrated in normal counter current electrophoresis against cell culture produced antigen and organ produced antigen, significantly lower antibody titres were found with cell culture produced antigen. The difference was not found when inhibition of precipitation of counter current electrophoresis was used.

Aleutian Mink Disease↗

[Conservative treatment of acute pancreatitis using intralesional electrophoresis].

Experimental data are discussed and experience in complex treatment of 102 patients with acute pancreatitis with the application of intralesional+ electrophoresis is analysed. It was demonstrated in experiments on 90 albino rats that in intralesional+ electrophoresis of radioactive++ 5-fluorouracil (5-FU), its concentration in the pancreas was 2.4-3-fold that in the group of animals in which only intraperitoneal injections of the agent were given. Intralesional+ 5-FU, antibiotic, and contrykal electrophoresis was applied in the clinic in 75 patients with edematous and in 27 patients with destructive pancreatitis. Intralesional+ electrophoresis had a favourable effect on the course of acute pancreatitis, but its efficacy was lower in destructive pancreatitis. Intralesional+ electrophoresis made it possible to lower the general therapeutic doses of these agents and to reduce the number of injections per 24 hours. Three fatal outcomes occurred.

Acute Disease↗

Glycerol-enhanced mini-polyacrylamide gel electrophoresis for the separation of differentially expressed DNA fragments in cDNA representational difference analysis.

Representational difference analysis (RDA) is a widely used technique in molecular biology. However, in practice, its efficiency depends on a rapid and reliable separation of the RDA fragments prior to cloning. To achieve this, we have compared and combined the separation efficiencies of conventional and MetaPhor agarose gel electrophoresis (MAGE) with a glycerol-enhanced mini-polyacrylamide gel electrophoresis (PAGE) system (Gem-PAGE). As anticipated, MetaPhor agarose provided significantly improved resolution over conventional agarose electrophoresis, but the latter remains useful to rapidly confirm the presence of RDA-enriched difference products and direct the concentration of MetaPhor agarose subsequently used for further fragment separation. Additional improvements in resolution were possible by using the Gem-PAGE system. The effect of glycerol on band definition of PAGE was most noticeable as the acrylamide to glycerol ratio (A:G) approached 1:2. Gels in which the A:G ratio was significantly above or below this resulted in both poor morphology and impaired resolution of the bands. By exploiting sequentially agarose-based and Gem-PAGE electrophoresis, the goal in RDA of "one band one product" is now realizable.

Acrylic Resins↗

Density gradient electrophoresis of cells in a reversible gel.

Density gradient electrophoresis permits the separation of cell types according to surface charge density with high resolution. Any source of flow compromises the resolving power of density gradient electrophoresis. Although procedures have been devised to successfully counteract electroosmotic and convective flows, the final collection of separands requires that they be pumped out of the electrophoresis column. Experiments were therefore designed to test the hypothesis that this flow could also be eliminated by trapping the separated bands in a gel, from which they could be collected by slicing the gel cylinder. Glutaraldehyde-fixed rat and rabbit erythrocytes were used as test particles in a phosphate-buffered isotonic Ficoll-sucrose density gradient in a 2.2 cm diameter, thermostated vertical glass column that could be opened at both ends. Two types of agarose were used as gel polymers: Electrophoresis grade agarose (J.T. Baker Chemical Co.) at final concentrations of 0.1 to 0.25% and SeaPrep ultralow gelling agarose (Marine Colloids Div., FMC Corp.) at a final concentration of 1.0%. Electrophoretic separability of the test particles and fluid stability were tested independently at 55 degrees C and 32 degrees C at which the two agaroses were, respectively, liquid. The experiments demonstrated that the higher temperatures required and the presence of agarose compromised neither the stability of the density gradient nor the migration properties of the cells, and cells can be separated in a sol at a temperature that is compatible with cell viability.

Animals↗

Sieving of double-stranded DNA during agarose gel electrophoresis.

Agarose gel electrophoresis is used to fractionate linear, double-stranded DNA by its length. Sieving of the gel is the cause of this fractionation and has been investigated by developing theoretical models and by quantifying sieving observed during electrophoresis. Here are reviewed the following aspects of the fractionation of linear, double-stranded DNA by agarose gel electrophoresis: (1) the basic observations that qualitatively characterize these fractionations, (2) evidence for the deformation of DNA's random coil, (3) quantitative analysis of the relationship of observed electrophoretic mobility to the DNA's length, (4) theoretical models that have been developed to explain data presented in Sections 1-3, (5) observations not yet quantitatively explained by models, and (6) some aspects of the use of a variable electrical field (pulsed-field gel electrophoresis) to improve separations.

Chemical Fractionation↗

Enzyme activity electrophoresis: development and applications.

The development of rocket enzyme activity electrophoresis for the detection and quantification of various proteinases, lipases and pectinases is presented. Rocket enzyme activity electrophoresis is more sensitive than the radial diffusion assay and often enables distinction between qualitatively different enzymes present in the same samples, whereas the radial diffusion assay only provides information on the overall enzyme activity. However, calibration and optimization of the enzyme activity electrophoretic assay have to be performed for each new enzyme-substrate system to be analyzed. Some of the common pitfalls in the development of new enzyme activity electrophoretic assays are presented. Enzyme activity electrophoresis can be applied in combination with other electrophoretic assays. Particularly the combination of enzyme activity electrophoresis with various immunoelectrophoretic methods can provide detailed information on the enzymes studies.

Electrochemistry↗

Discontinuous buffer system for polyacrylamide and agarose gel electrophoresis of DNA fragments.

DNA fragments up to 9 kb in size were stacked and separated by polyacrylamide gel electrophoresis, and those up to 50 kb in size by agarose gel electrophoresis, using a discontinuous buffer system. Polyacrylamide gels at pH 8.9, 2 degrees C, 0.01 M ionic strength, yielded sharp bands with DNA loads of 8 micrograms/cm2 of gel of a mixture of 19 DNA fragments in the size range of 72-23130 bp, while agarose gels at pH 8.5, 25 degrees C, provided well-resolved, unperturbed bands at 0.04 M ionic strength with DNA loads of 1 microgram/cm2 of the same mixture. Note that the ionic strength of the agarose gels is comparable to the conventionally used 0.5 x TBE (Tris-borate-EDTA) buffer, while that successfully applied to polyacrylamide is seven-fold less than the ionic strength of conventionally used 1 x TBE buffer, with a substantially shorter duration of electrophoresis as a result. The application of a discontinuous buffer system to the gel electrophoresis of DNA results in (i) Band identification by Rf, the migration distance relative to a sharply defined "buffer front" (moving boundary). This is sufficiently labor saving, compared to determining absolute mobilities, so as to render practical the expression of bands as numbers, with benefits for data storage, statistical manipulations and physico-chemical exploitation of mobility data. The use of Rf's also circumvents loss of precision in mobility measurement resulting from progressive band spreading of dye bands used as a front. (ii) A uniformly and highly concentrated starting zone, beneficial to resolution, is obtained, without the losses by which separate concentration steps are usually burdened.(ABSTRACT TRUNCATED AT 250 WORDS)

Base Composition↗

Two-dimensional polyacrylamide gel electrophoresis, with immobilized pH gradients in the first dimension, of barley seed proteins: discrimination of cultivars with different malting grades.

The suitability of high-resolution two-dimensional gel electrophoresis for barley cultivar discrimination and for classification with respect to their malting properties was studied. Seed proteins of 14 barley cultivars with different malting qualities were extracted with urea/dithiothreitol/Nonidet P-40 buffer and subjected to two-dimensional gel electrophoresis with immobilized pH gradients in the first dimension (IPG-DALT). The results of IPG-DALT were compared to the protein patterns obtained by a standard technique, sodium dodecyl sulfate polyacrylamide gel electrophoresis of hordeins. Sodium dodecyl sulfate-gel electrophoresis yielded seven different "B" and four different "C" hordein patterns; "A" and "D" hordein patterns were uniform in all cultivars tested. Four cultivars could be distinguished unequivocally, the others were classified into three groups containing between two and five cultivars. In contrast to these findings. IPG-DALT yielded three different "A", eight different "B", four different "C" and two different "D" hordein patterns. When the "A", "B", "C" and "D" hordein patterns were combined, ten cultivars exhibited unique hordein patterns whereas the remaining ones were classified into two groups containing two cultivars each. Moreover, when albumin and globulin proteins were used for evaluation in addition to the hordeins, all cultivars could be discriminated by IPG-DALT. IPG-DALT, performed on small-scale and/or ready-made gels, proved to be an ideal complementary system to one-dimensional electrophoretic methods for routine seed testing purposes because of its speed, reliability, and simplicity. IPG-DALT was also applied to study the relationship between the different polypeptide patterns and the malting quality. Although cultivars with identical one-dimensional protein patterns but different malting quality could be successfully differentiated by IPG-DALT, a direct correlation between specific protein spots or protein patterns to the malting quality was not found within the cultivars tested.

Electrophoresis, Gel, Two-Dimensional↗

Pulsed field electrophoresis for the separation of protein-sodium dodecyl sulfate-complexes in polyacrylamide gels.

Polyacrylamide gel electrophoresis of proteins was studied using a pulsed-current mode. A new "local field" distribution was used to correct the gel patterns and optimize migration. A corrective field was applied at fixed 2 s intervals to a constant field, inducing a complex relaxation mechanism. Calculated variations in the local field directions decreased the electric strain on the gel during the run, with resultant optimum gel structure. The relaxation mechanism was found to enhance the absolute mobility of proteins with shorter running times compared to constant field gel electrophoresis (CFGE) and other pulsed field techniques. The enhancement of molecular mobility was explored by transverse pore gradient gel electrophoresis. Ferguson curves which exhibited a convex shape in CFGE were linearized by the new pulsed-field method named pulsed oscillatory high-performance electrophoresis (POPE).

Animals↗

Sodium dodecyl sulfate-gel electrophoresis of proteins employing short capillaries.

The performance of capillary gel-sodium dodecyl sulfate (SDS) electrophoresis for molecular-mass-dependent separation of proteins has been examined employing cross-linked polyacrylamide gels and untreated fused-silica capillaries of short length. An apparatus for capillary electrophoresis has been constructed, combining a UV detector equipped with a capillary holder, a power supply, and a micromanipulator for sample loading. The apparatus is capable of accommodating gel capillaries of different lengths and can be operated with two methods of sample loading: manual injection on top of the gel or electrokinetic injection. Standard proteins have been separated according to their molecular mass (ranging from 17000 to 116000) within 30 min, employing gel capillaries of effective lengths shorter than 10 cm and polyacrylamide gels ranging from 2.4 to 4.8%T (5%C). The results confirmed that gel capillaries of effective length less than 10 cm can be used for protein size-separation by SDS electrophoresis, with much higher performance than is achieved in rod gel-SDS electrophoresis.

Apoproteins↗

Reproducibility of mobility in gel electrophoresis.

The quantitative exploitation of gel electrophoresis to yield molecular and gel fiber properties rests on the assumption that mobility is characteristic of the macromolecule migrating as a band and is a physical constant for any system defined by pH, ionic strength and temperature. This assumption has not been tested intra-experimentally in previous literature. With the commercial introduction of automated gel electrophoresis apparatus, the collection of multiple mobility data during a single run without additional expense of labor has made it possible to test the assumption. As a start, we undertook that test for three proteins and their sodium dodecyl sulfate (SDS) derivatives, in agarose and polyacrylamide gel electrophoresis, various field strengths, continuous and discontinuous buffers, as well as intra- and interexperimentally. It was found that in agarose gel electrophoresis conducted in a single buffer, the standard deviation of mobility over a wide concentration range ranges intra-experimentally from 0.2 to 1.3% for two globular proteins and 1.4 to 5.3% for the same proteins derivatized with SDS. Interexperimentally, it was 3% in the single case tested to date. The standard deviation in polyacrylamide appears to be higher, varies in inverse relation to the mobility value, i.e. increases with gel concentration in the range of 11 to 19%T, and varies substantially between the two SDS-proteins investigated. Mobility in a discontinuous buffer system decreases continuously due to the decreasing leading phase/trailing phase ratio along the migration path. The decrease is sharpest in the "nonrestrictive" stacking gel.

Autoanalysis↗

The resolution between two native proteins and between their sodium dodecyl sulfate-complexes in agarose and polyacrylamide gel electrophoresis.

Commercial gel electrophoresis apparatus with intermittent fluorescence scanning of the migration path (HPGE-1000 apparatus, LabIntelligence) makes it possible to measure band width and migration distance as a function of the duration of electrophoresis. As a result, resolution can be evaluated quantitatively and therefore different gel media can be compared objectively. The resolution of fluorescein carboxylate labeled conalbumin (molecular mass 86 kDa) and soybean trypsin inhibitor (22.7 kDa) in gel electrophoresis was found to increase as a function of the gel type in the order SeaKem GTG-, SeaKem Gold-agarose, 2% N,N'-methylenebisacrylamide cross-linked polyacrylamide, MetaPhor-XR-, and SeaPrep-agarose. The advantage in resolving capacity of SeaPrep agarose over the polyacrylamide gel was by a factor of up to five. The resolving capacity of the agaroses was in indirect relation to the degree of electroendosmosis. In all media, resolution increased with migration distance (time). The same proteins when reacted with sodium dodecyl sulfate (SDS) resolve (i) better at up to 6% SeaPrep agarose concentration than in polyacrylamide, as in the gel electrophoresis of the native proteins; (ii) less effectively, by contrast, at SeaPrep agarose concentrations > 6%, than in polyacrylamide gel; and (iii) significantly better in 4-6% SeaPrep agarose than in 4-6% SeaKem GTG agarose. Since Ferguson plot analysis in both agarose and polyacrylamide gels shows that the two SDS-proteins are larger than the native proteins with which they are complexed, the superiority of polyacrylamide gels above 7% appears to be correlated with the fact that its mean pore radius, estimated for both media using identical assumptions and identical rigid spherical standards - proteins, is approximately seven times larger than that of SeaPrep agarose in the concentration range of 3-8%, and that therefore the molecular "fit" in polyacrylamide is closer than that in SeaPrep agarose of the concentration range used. The dependence of resolution on the ratio of particle radius to mean pore radius ("fit") is also suggested by the fact that the two SDS-proteins resolve in a biphasic dependence on gel concentration in both agarose and polyacrylamide, with a maximum at 6% agarose and 10% polyacrylamide.

Conalbumin↗

Parallelism between width and asymmetry of peaks of rigid, spherical particles in capillary zone electrophoresis using polymer solutions.

Peak width and peak asymmetry of rigid spherical particles in the size range of 3-100 nm radius (R) were measured in capillary zone electrophoresis (CZE), using buffered uncross-linked polyacrylamide of Mr 5.0 X 10(6). Polymer concentration-dependent spreading of peak width and peak asymmetry were found to parallel one another. The parallelism holds whether the particle size is within the "small" (R < 20 nm) or "large" (R > 20 nm) size ranges previously found to differ in the mechanism of particle size dependent retardation of electrophoretic migration (S. P. Radko and A. Chrambach, Electrophoresis 1996, 17, 1094-1102). In application to the "small" particle size range, the parallelism between band width and band asymmetry can be qualitatively interpreted to be consistent with the Giddings-Weiss mechanism (G. H. Weiss et al., Electrophoresis 1996, 17, 1325-1332) of electrophoresis in polymer-containing media which postulates a dependence of band width and band asymmetry on the equilibrium between "stationary" and "mobile" states of the particle.

Acrylic Resins↗

The band areas of proteins determined by fluorescent scanning in the commercial automated gel electrophoresis apparatus.

An automated gel electrophoresis apparatus, recently available commercially, allows one to follow the band during electrophoresis in real time, and lends itself therefore to an evaluation of bandwidth as a function of migration time (the dispersion coefficient), resolution and band shape. These determinations assume the constancy of band area with migration time and at various gel concentrations. The purpose of the present study was to verify these assumptions. Representative proteins and sodium dodecyl sulfate (SDS)-proteins, either natively fluorescent or fluorescein carboxylate labeled, were found to exhibit band areas which approach constancy as a function of migration time in both agarose and polyacrylamide gel electrophoresis, provided that (i) the protein concentration under the band was low enough to obviate self-quenching of fluorescence; (ii) the separation of the protein of interest from contaminants had progressed sufficiently during the time at which band areas were measured; (iii) the baseline under the peak was sufficiently well defined. However, band areas decrease with increasing gel concentration. Protein peaks exhibited leading and trailing tails. The ratio of the combined tail area to total area appeared to be near-constant at varying migration times. However, that ratio increases with increasing gel concentration. The tail area does not appear to be an artifact of fluorometric detection since it is reproduced upon fluorimetric analysis of the protein eluted from gel slices after electrophoresis. However, it may be due to photochemical destruction under the conditions of repetitive fluorometric peak detection.

Adsorption↗

Nafion membrane electrophoresis with direct and simplified end-column pulse electrochemical detection of amino acids.

A novel electrophoresis technique, in which the separation column was replaced by a strip of Nafion membrane (5.0 cm x 0.20 mm x 0.25 mm), was developed for the separation of an amino acid mixture (glycine, asparic acid and lysine), followed by quadruple-pulse electrochemical detection. Nafion membrane contains hydrophilic pores (10-20 A and 50-60 A in size) acting as very narrow electrophoresis channels. The fixed-charge sites (-SO(3) (-)) on the hydrophilic pore surface provide a strong charged background. A platinum disk electrode (0.90 mm inner diameter) was employed as the detection electrode and the electrophoresis cathode was used as the quasi-reference and counter electrode for the end-column electrochemical detector, without decoupler. Under optimized conditions the mixture of amino acids could be separated at a voltage of only 90 V with a detection limit of 10(-7) M, indicating that Nafion membrane electrophoresis is a potentially attractive technique for the separation of small organic molecules or ions.

Amino Acids↗

Rapid high-resolution electrophoresis of multimeric von Willebrand Factor using a thermopiloted gel apparatus.

Rapid and highly reproducible nonreducing agarose gel electrophoresis (NRAGE) of von Willebrand Factor (vWF) multimers was performed using a thermostated minigel apparatus that monitors and precisely controls internal gel temperature. The substitution of lithium dodecyl sulfate (LiDS) for sodium dodecyl sulfate (SDS) allowed electrophoresis to be performed below the 16 degrees C Krafft point of SDS and facilitated NRAGE of vWF over the entire range of 0-35 degrees C. Internal gel temperature was regulated by a thermocouple probe inserted directly into the gel during electrophoresis which interfaced with a thermopilot that continually measures and adjusts temperature to within +/- 0.5 degrees C. At 10 degrees C operative temperature, NRAGE at 1.5% agarose concentration was completed in 20 min at 250 V. Electrophoresis could be performed in only 10 min at 500 V, but at such high voltages, localized temperature fluctuations as much as 6 degrees C resulted in perturbation of banding patterns in those vicinities. In the optimized method, both high molecular weight multimers and proteolytic fragments of vWF were separable suggesting clinical applicability of this system for the diagnosis of von Willebrand Disease and thrombotic thrombocytopenic purpura.

Electrophoresis, Agar Gel↗

Quality control and quality assurance aspects of the routine use of capillary electrophoresis for serum and urine proteins in clinical laboratories.

Using capillary electrophoresis (CE) for serum protein electrophoresis, the quality of results begins with monitoring a well-functioning instrument, using scrupulously clean capillaries, well-calibrated methods as well as regular use of an internal quality control material. Quality assurance programs are available in countries such as Australia, United Kingdom, United States, and European countries such as Sweden and Germany. The present commercial control material that is available gives percentages of albumin, alpha 1, alpha 2, beta- and gamma-globulins, the gamma-component being of normal distribution, and not containing any monoclonal protein component. We feel that a quantitative commercial control material containing a monoclonal protein at decision level for treating myeloma patients would be beneficial to all laboratories as a serum protein electrophoresis control, whether the analysis is by CE or agarose gels. The same applies for control material for urinary protein electrophoresis.

Blood Protein Electrophoresis↗

Submerged gel electrophoresis on Spreadex gels--a new method for APC gene mutation detection.

Familial adenomatous polyposis (FAP) is an autosomal dominant inherited disease. Patients with FAP develop hundreds to thousands of adenomatous polyps in the colon and rectum during their 2nd or 3rd decades, and one or more of them progress to cancer if left without surgical treatment. The gene responsible for FAP was identified in 1991 and termed the APC (adenomatous polyposis coli) gene. Following identification of APC, a number of germ-line mutations responsible for the development of the disease were found. The purpose of this study was to determine the usefulness of a new method, submerged gel electrophoresis, in the detection of the most-frequent mutation of the APC gene [5-base pair (bp) deletion in codon 1309], especially in the presymptomatic diagnosis of FAP. Genomic DNAs were isolated from peripheral blood of patients and their relatives. We used two methods, electrophoresis on polyacrylamide gel and submerged gel electrophoresis, for the identification of APC gene codon 1309 mutation. After only 110 min PCR fragments of 91 bp and 86 bp (5-bp deletion) were completely resolved on a Spreadex EL300 gel. Our results showed that electrophoresis using Spreadex gels provides a simple and rapid non-radioactive method for determination of the most-frequent germ-line mutations in the APC gene.

Adenomatous Polyposis Coli↗