PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Comparative reactivity and mechanical properties of human isolated internal mammary and radial arteries.

OBJECTIVE: The aim of this study was to analyse the arterial wall mechanics and the vasoreactive properties of the radial artery in comparison with those of the internal mammary artery and to discuss their implications for coronary bypass grafts. METHODS: Measurements of pressure and diameter were obtained from cylindrical segments, whereas measurements of reactivity were obtained from ring segments from the same arteries. We used an echo-tracking technique of high resolution enabling to investigate, in vitro, the diameter and the wall thickness of arterial cylindrical segments. Furthermore, the compliance, distensibility and incremental elastic modulus of the radial and of the mammary arteries were determined for a wide range of transmural pressure (0-200 mmHg) in presence and absence of norepinephrine (NE). RESULTS: Our results show that NE caused vasoconstriction of the two arteries. Strain was found significantly higher for the radial artery than for the internal mammary artery at any given value of stress both in the presence and in the absence of NE. In presence of NE, compliance for radial artery, in the overall transmural pressure range, did not change, whereas, distensibility was significantly increased and the elastic modulus was significantly decreased. Under the same conditions, the distensibility of the mammary artery tended to decrease and its elastic modulus to increase. In parallel, the vasoreactive properties of the two arteries confirmed the previous results showing that radial artery developed a significant higher tension to vasoconstricting agents (KCl, NE and phenylephrine (PHE)) and higher relaxation to isradipine than internal mammary artery. Moreover, radial artery displayed a lesser sensitivity to sodium nitroprusside than internal mammary artery. Furthermore, sensitivity to NE was found to be 7-fold higher for radial artery than for internal mammary artery. CONCLUSION: Taken together, data on the mechanical and reactive properties of radial and internal mammary arteries show why the radial artery displayed a higher potential for spasm than the internal mammary artery and why the use of Ca2+ channel blocker can decrease the incidence of occlusion and spasm.

Biomechanical Phenomena↗

Viscosity and elasticity during collagen assembly in vitro: relevance to matrix-driven translocation.

In order to better understand the gelation process associated with collagen assembly, and the mechanism of the in vitro morphogenetic phenomenon of "matrix-driven translocation" [S.A. Newman et al. (1985) Science, 228, 885-889], the viscosity and elastic modulus of assembling collagen matrices in the presence and absence of polystyrene latex beads was investigated. Viscosity measurements at very low shear rates (0.016-0.0549 s(-1)) were performed over a range of temperatures (6.9-11.5 degrees C) in a Couette viscometer. A magnetic levitation sphere rheometer was used to measure the shear elastic modulus of the assembling matrices during the late phase of the gelation process. Gelation was detected by the rapid increase in viscosity that occurred after a lag time tL that varied between O and approximately 500 s. After a rise in viscosity that occurred over an additional approximately 500 s, the collagen matrix was characterized by an elastic modulus of the order of several Pa. The lag time of the assembly process was relatively insensitive to differences in shear rate within the variability of the sample preparation, but was inversely proportional to the time the sample spent on ice before being raised to the test temperature, for test temperatures > 9 degrees C. This suggests that structures important for fibrillogenesis are capable of forming at 0 degrees C. The time dependence of the gelation process is well-described by an exponential law with a rate constant K approximately 0.1 s(-1). Significantly, K was consistently larger in collagen preparations that contained cell-sized polystyrene beads. From these results, along with prior information on effective surface tension differences of bead-containing and bead-lacking collagen matrices, we conclude that changes in matrix organization contributing to matrix-driven translocation are initiated during the lag phase of fibrillogenesis when the viscosity is < or = 0.1 Poise. The phenomenon may make use of small differentials in viscosity and/or elasticity, resulting from the interaction of the beads with the assembling matrix. These properties are well described by standard models of concentrated solutions.

Animals↗

Infant skull and suture properties: measurements and implications for mechanisms of pediatric brain injury.

The mechanical properties of the adult human skull are well documented, but little information is available for the infant skull. To determine the age-dependent changes in skull properties, we tested human and porcine infant cranial bone in three-point bending. The measurement of elastic modulus in the human and porcine infant cranial bone agrees with and extends previous published data [McPherson, G. K., and Kriewall, T. J. (1980), J. Biomech., 13, pp. 9-16] for human infant cranial bone. After confirming that the porcine and human cranial bone properties were comparable, additional tensile and three-point bending studies were conducted on porcine cranial bone and suture. Comparisons of the porcine infant data with previously published adult human data demonstrate that the elastic modulus, ultimate stress, and energy absorbed to failure increase, and the ultimate strain decreases with age for cranial bone. Likewise, we conclude that the elastic modulus, ultimate stress, and energy absorbed to failure increase with age for sutures. We constructed two finite element models of an idealized one-month old infant head, one with pediatric and the other adult skull properties, and subjected them to impact loading to investigate the contribution of the cranial bone properties on the intracranial tissue deformation pattern. The computational simulations demonstrate that the comparatively compliant skull and membranous suture properties of the infant brain case are associated with large cranial shape changes, and a more diffuse pattern of brain distortion than when the skull takes on adult properties. These studies are a fundamental initial step in predicting the unique mechanical response of the pediatric skull to traumatic loads associated with head injury and, thus, for defining head injury thresholds for children.

Adult↗

Possible role of decorin glycosaminoglycans in fibril to fibril force transfer in relative mature tendons--a computational study from molecular to microstructural level.

Experimental studies on immature tendons have shown that the collagen fibril net is discontinuous. Manifold evidences, despite not being conclusive, indicate that mature tissue is discontinuous as well. According to composite theory, there is no requirement that the fibrils should extend from one end of the tissue to the other; indeed, an interfibrillar matrix with a low elastic modulus would be sufficient to guarantee the mechanical properties of the tendon. Possible mechanisms for the stress-transfer involve the interfibrillar proteoglycans and can be related to the matrix shear stress and to electrostatic non-covalent forces. Recent studies have shown that the glycosaminoglycans (GAGs) bound to decorin act like bridges between contiguous fibrils connecting adjacent fibril every 64-68 nm; this architecture would suggest their possible role in providing the mechanical integrity of the tendon structure. The present paper investigates the ability of decorin GAGs to transfer forces between adjacent fibrils. In order to test this hypothesis the stiffness of chondroitin-6-sulphate, a typical GAG associated to decorin, has been evaluated through the molecular mechanics approach. The obtained GAG stiffness is piecewise linear with an initial plateau at low strains (<800%) and a high stiffness region (3.1 x 10(-11)N/nm) afterwards. By introducing the calculated GAG stiffness in a multi-fibril model, miming the relative mature tendon architecture, the stress-strain behaviour of the collagen fibre was determined. The fibre incremental elastic modulus obtained ranges between 100 and 475 MPa for strains between 2% and 6%. The elastic modulus value depends directly on the fibril length, diameter and inversely on the interfibrillar distance. In particular, according to the obtained results, the length of the fibril is likely to play the major role in determining stiffness in mature tendons.

Animals↗

Computation of adherent cell elasticity for critical cell-bead geometry in magnetic twisting experiments.

Quantification of the cell elastic modulus is a central issue of micromanipulation techniques used to analyze the mechanical properties of living adherent cells. In magnetic twisting cytometry (MTC), magnetic beads of radius R, linked to the cell cytoskeleton through transmembrane receptors, are twisted. The relationships between imposed external torque and measured resulting bead rotation or translation only provide values of the apparent cell stiffness. Thus, specific correcting coefficients have to be considered in order to derive the cell elastic modulus. This issue has been highlighted in previous studies, but general relationships forhandling such corrections are still lacking while they could help to understand and reduce the large dispersion of the reported values of cell elastic modulus. This work establishes generalized abacuses of the correcting coefficients from which the Young's modulus of a cell probed by MTC can be derived. Based on a 3D finite element analysis of an hyperelastic (neo-Hookean) cell, we show that the dimensionless ratio h(u)/2R, where h(u) is the cell height below the bead, is an essential parameter for quantification of the cell elasticity. This result could partly explain the still intriguing question of the large variation of measured elastic moduli with probe size.

Algorithms↗

Physical properties of three packable resin-composite restorative materials.

This study evaluated selected physical properties of three packable resin composites (Alert, SureFil and Solitaire) and compared them to two conventional hybrid materials (Prodigy and Z-100). The specific properties investigated were diametral tensile strength, transverse strength, elastic modulus and fracture toughness. Following photopolymerization, specimens for each composite material were stored in deionized water at 37 degrees C for 35 days. A one-way ANOVA and Tukey's post-hoc test were employed for each property to determine whether significant differences occurred with respect to specific restorative materials. All materials had statistically similar diametral tensile strengths. Alert had the highest mean fracture toughness and elastic modulus but had a low mean transverse-strength value. SureFil exhibited good mean physical property values compared to both the conventional and packable materials. Solitaire had low mean fracture toughness, transverse strength and elastic modulus values, which could cause concern regarding use in posterior restorations. The packable resin composites tested had a wide range of mean values for the physical properties investigated. Generally, Alert and SureFil were superior to Solitaire and comparable to the hybrid materials Prodigy and Z-100, but clear discrimination among performance of these materials requires clinical testing.

Analysis of Variance↗

Osteoblasts generate harder, stiffer, and more delamination-resistant mineralized tissue on titanium than on polystyrene, associated with distinct tissue micro- and ultrastructure.

UNLABELLED: This study revealed that osteoblasts generate harder, stiffer, and more delamination-resistant mineralized tissue on titanium than on the tissue culture polystyrene, associated with modulated gene expression, uniform mineralization, well-crystallized interfacial calcium-phosphate layer, and intensive collagen deposition. Knowledge of this titanium-induced alteration of osteogenic potential leading to enhanced intrinsic biomechanical properties of mineralized tissue provides novel opportunities and implications for understanding and improving bone-titanium integration and engineering physiomechanically tolerant bone. INTRODUCTION: Bone-titanium integration is a biological phenomenon characterized by continuous generation and preservation of peri-implant bone and serves as endosseous anchors against endogenous and exogenous loading, of which mechanisms are poorly understood. This study determines the intrinsic biomechanical properties and interfacial strength of cultured mineralized tissue on titanium and characterizes the tissue structure as possible contributing factors in biomechanical modulation. MATERIALS AND METHODS: Rat bone marrow-derived osteoblastic cells were cultured either on a tissue culture-grade polystyrene dish or titanium-coated polystyrene dish having comparable surface topography. Nano-indentation and nano-scratch tests were undertaken on mineralized tissues cultured for 28 days to evaluate its hardness, elastic modulus, and critical load (force required to delaminate tissue). Gene expression was analyzed using RT-PCR. The tissue structural properties were examined by scanning electron microscopy (SEM), collagen colorimetry and localization with Sirius red stain, mineral quantification, and localization with von Kossa stain and transmission electron microscopy (TEM). RESULTS: Hardness and elastic modulus of mineralized tissue on titanium were three and two times greater, respectively, than those on the polystyrene. Three times greater force was required to delaminate the tissue on titanium than that on the polystyrene. SEM of the polystyrene culture displayed a porous structure consisting of fibrous and globular components, whereas the titanium tissue culture appeared to be uniformly solid. Cell proliferation was remarkably reduced on titanium. Microscopic observations revealed that the mineralized tissue on titanium was composed of uniform collagen-supported mineralization from the titanium interface to the outer surface, with intensive collagen deposition at tissue-titanium interface. In contrast, tissue on the polystyrene was characterized by collagen-deficient mineralization at the polystyrene interface and calcium-free collagenous matrix formation in the outer tissue area. Such characteristic microstructure of titanium-associated tissue was corresponded with upregulated gene expression of collagen I and III, osteopontin, and osteocalcin mRNA. Cross-sectional TEM revealed the apposition of a high-contrast and well-crystallized calcium phosphate layer at the titanium interface but not at the polystyrene interface. CONCLUSIONS: Culturing osteoblasts on titanium, compared with polystyrene, enhances the hardness, elastic modulus, and interfacial strength of mineralized tissue to a higher degree. Titanium per se possesses an ability to alter cellular phenotypes and tissue micro- and ultrastructure that result in enhanced intrinsic biomechanical properties of mineralized tissue.

Animals↗

The modulus of elasticity of lobster aorta microfibrils.

The presence of elastic fibres in the extracellular matrix (ECM) provides physiologically important elastic properties for many tissues. Until recently, microfibrils, one component of the ECM, were thought primarily to serve as a scaffolding on which elastin is deposited during development to form elaunin fibres [1]. The most prominent protein that forms mammalian microfibrils is fibrillin. It is known that mutations in the fibrillin gene cause a heterogenous connective tissue disease called Marfan syndrome [2], so information on mechanical properties of microfibrils or their role in tissue function would be useful. Microfibrils are also found in the ECM of some invertebrate tissues, and there is growing evidence that the protein forming the structure is homologous to mammalian fibrillin [3,4]. It has been shown that the microfibril-based arterial wall of the lobster has viscoelastic properties [5], and we have now utilized this primitive artery to measure the modulus of elasticity of microfibrils. It is similar to that of the rubber-like protein elastin.

Animals↗

Cuvier's beaked whale (Ziphius cavirostris) head tissues: physical properties and CT imaging.

Tissue physical properties from a Cuvier's beaked whale (Ziphius cavirostris) neonate head are reported and compared with computed tomography (CT) X-ray imaging. Physical properties measured include longitudinal sound velocity, density, elastic modulus and hysteresis. Tissues were classified by type as follows: mandibular acoustic fat, mandibular blubber, forehead acoustic fat (melon), forehead blubber, muscle and connective tissue. Results show that each class of tissues has unique, co-varying physical properties. The mandibular acoustic fats had minimal values for sound speed (1350+/-10.6 m s(-1)) and mass density (890+/-23 kg m(-3)). These values increased through mandibular blubber (1376+/-13 m s(-1), 919+/-13 kg m(-3)), melon (1382+/-23 m s(-1), 937+/-17 kg m(-3)), forehead blubber (1401+/-7.8 m s(-1), 935+/-25 kg m(-3)) and muscle (1517+/-46.8 m s(-1), 993+/-58 kg m(-3)). Connective tissue had the greatest mean sound speed and density (1628+/-48.7 m s(-1), 1087+/-41 kg m(-3)). The melon formed a low-density, low-sound-speed core, supporting its function as a sound focusing organ. Hounsfield unit (HU) values from CT X-ray imaging are correlated with density and sound speed values, allowing HU values to be used to predict these physical properties. Blubber and connective tissues have a higher elastic modulus than acoustic fats and melon, suggesting more collagen structure in blubber and connective tissues. Blubber tissue elastic modulus is nonlinear with varying stress, becoming more incompressible as stress is increased. These data provide important physical properties required to construct models of the sound generation and reception mechanisms in Ziphius cavirostris heads, as well as models of their interaction with anthropogenic sound.

Adipose Tissue↗

Elasticity of passive blood vessels: a new concept.

The mechanical properties of passive blood vessels are generally thought to depend on the parallel arrangement of elastin and collagen with linear elasticity and collagen recruitment depending on vessel strain [hook-on (HO) model]. We evaluated an alternative model [serial element (SE) model] consisting of the series arrangement of an infinite number of elements, each containing elastin with a constant elastic modulus and collagen that switches stepwise from slack (zero stress) to fully rigid (infinite stiffness) on ongoing element strain. Both models were implemented with Weibull distributions for collagen recruitment strain (HO model) and collagen tightening strain (SE model). The models were tested in experiments on rat mesenteric small arteries. Strain-tension relations were obtained before and after two rounds of digestion by collagenase. Both models fitted the data prior to digestion. However, for the HO model, this required unrealistically low estimates for collagen recruitment or elastic modulus and unrealistically high estimates for distension of collagen fibers. Furthermore, the data after digestion were far better predicted by the SE model compared with the HO model. Finally, the SE model required one parameter less (collagen elastic modulus). Therefore, the SE model provides a valuable starting point for the understanding of vascular mechanics and remodeling of vessels.

Animals↗

Material structure, stiffness, and adhesion: why attachment pads of the grasshopper (Tettigonia viridissima) adhere more strongly than those of the locust (Locusta migratoria) (Insecta: Orthoptera).

The morphology, ultrastructure, effective elastic modulus, and adhesive properties of two different smooth-type attachment pads were studied in two orthopteran species. Tettigonia viridissima (Ensifera) and Locusta migratoria (Caelifera) have a similar structural organization of their attachment pads. They both possess a flexible exocuticle, where the cuticular fibrils are fused into relatively large rods oriented at an angle to the surface. The compliant material of the pad contributes to the contact formation with the substrate. However, the pad material structure was found to be different in these two species. L. migratoria pads bear a thick sub-superficial layer, as well as a higher density of rods. The indentation experiments showed a higher effective elastic modulus and a lower work of adhesion for L. migratoria pads. When the indentations were made at different depths, a higher effective elastic modulus was revealed at lower indentation depths in both species. This effect is explained by the higher stiffness of the superficial pad layer. The obtained results demonstrate a clear correlation between density of the fibres, thickness of the superficial layer, compliance of the pad, and its adhesive properties. Such material structures and properties may be dependent on the preferred environment of each species.

Adhesiveness↗

An evaluation of variables influencing implant fixation by direct bone apposition.

A systematic mechanical and histologic evaluation of design variables affecting bone apposition to various biocompatible materials was undertaken. The variables investigated included material elastic modulus, material surface texture, as well as material surface composition. The implant materials included polymethylmethacrylate (PMMA), low-temperature isotropic (LTI) pyrolytic carbon, commercially pure (C.P.) titanium, and aluminum oxide (Al2O3). Implant surface texture was varied by either polishing or grit-blasting the various materials. Implant surface composition was varied by applying a coating of ultra-low temperature isotropic (ULTI) pyrolytic carbon to the various implants. A total of 12 types of implants were evaluated in vivo by placement transcortically in the femora of adult mongrel dogs for a period of 32 weeks. Following sacrifice, mechanical push-out testing was performed to determine interface shear strength and interface shear stiffness. The results obtained from mechanical testing indicate that for implants fixed by direct bone apposition, interface stiffness and interface shear strength are not significantly affected by either implant elastic modulus or implant surface composition. Varying surface texture, however, significantly affected the interface response to the implants. For each elastic modulus group the roughened surfaced implants exhibited greater strengths than the corresponding smooth surfaced implants. Undecalcified histologic evaluation of the implants demonstrated that the roughened implants exhibited direct bone apposition, whereas the smooth implants exhibited various degrees of fibrous tissue encasement. Thus, for implants utilizing direct bone apposition fixation, it appears that of the parameters investigated, implant surface texture is the most significant.

Aluminum Oxide↗

Validation of speed of sound for the assessment of cortical bone maturity.

Bone changes its structural and physical properties during maturation. In order to validate ultrasound measurements with regard to their usefulness in assessing cortical bone maturation, speed of sound (SOS) data were compared with mechanical properties (elastic modulus, bending strength, and cortical surface hardness), density and water content. Thirty pig mandibles were selected from three different age groups. Rectangular specimens of the buccal cortical bone of the body of the mandible were prepared. SOS was measured with pulsed ultrasound at a frequency of 2 MHz in all three dimensions, bone mineral density (BMD) by quantitative computed tomography, breaking strength and apparent elastic modulus in a three-point bending test to failure, water content using the lyophilization technique, and micro-indentation hardness using a modified Vickers' technique. While SOS in all three directions, BMD, surface hardness, and bending strength increased significantly (P < 0.001), bone tissue water content decreased significantly (P < 0.001) with age. Changes in the elastic modulus were not significant. Changes in SOS in the antero-posterior and apico-occlusal directions can be partly explained by BMD. In a bucco-lingual direction the increase is inadequately explained by the physical parameters investigated, and has possibly to be attributed to structural differences. Maturation of the mandible implies changes in its architectural organization, in material composition, and in the mechanical properties of cortical bone. In vitro SOS measurements reflect different structural and physical properties that are all age dependent. It thus seems feasible that age-related changes in bone maturation could be monitored by SOS measurements.

Age Factors↗

A constant compliance force modulation technique for scanning force microscopy (SFM) imaging of polymer surface elasticity.

A new method of force modulation scanning force microscopy (SFM) imaging based on a constant compliance feedback loop is presented. The feedback adjusts the loading force applied by the SFM tip to the surface in order to maintain a constant compliance beneath the tip. The new method, constant compliance force modulation (CCFM), has the advantage of being able to quantify the loading force exerted by the tip onto the sample surface and thus to estimate the elastic modulus of the material probed by the SFM tip. Once the elastic modulus of one region is known, the elastic moduli of other surface regions can be estimated from the spatial map of loading forces using the Hertz model of deformation. Force vs. displacement measurements made on one surface locality could also be used to estimate the local modulus. Several model surfaces, including a rubber-toughened epoxy polymer blend which showed clearly resolved compliant rubber phases within the harder epoxy matrix, were analyzed with the CCFM technique to illustrate the method's application.

Compliance↗

Water sorption and mechanical properties of light-cured proprietary composite tooth restorative materials.

Seven light-cured proprietary composite restorative materials, P-50 (3M), P-10 (3M), P-30 (3M), FulFil (Caulk), Herculite (Kerr), Silux Plus (3M) and Silux (3M) were characterized in terms of water uptake at 37 degrees C. For several of the systems, elastic modulus and glass transition temperature were evaluated with a dynamic mechanical analyser (Autovibron DDV-II-C). Model systems such as bis-GMA (75%) + triethylene glycol dimethacrylate (25%), bis-GMA (30%) + triethylene glycol dimethacrylate (10%) + lithium aluminium silicate (60%), bis-GMA + triethylene glycol dimethacrylate (14%) + barium glass (silanated) (86%) and bis-GMA + triethylene glycol dimethacrylate (14%) + zinc glass (silanated) (86%) were also studied with reference to water sorption. It was concluded that the changes in elastic modulus tend to confirm the hypothesis that the matrix-filler interface contains water. Silux and Silux Plus accommodated the greatest amount of water at the interface. Silux Plus displayed a dramatic reduction in elastic modulus c. 0 degrees C, indicating possible melting of water clusters. It appeared that the only available hole for water clusters was at the matrix-filler interface.

Adsorption↗

Effects of vitamin K2 (menatetrenone) and alendronate on bone mineral density and bone strength in rats fed a low-magnesium diet.

In this study, we examined changes in bone parameters and bone strength in rats fed low-Mg diets (experiment 1) and the effects of vitamin K2 (MK-4, experiment 3) and alendronate (ALN, experiment 2) in this model. In experiment 1, 5-week-old male Wistar rats were fed three low-Mg diets (Mg 9, 6, 3 mg/100 g diet) for 4 weeks. Although the cortical bone mineral content (CtBMC) and cortical thickness (CtTh) of the femoral diaphysis in all low-Mg-diet groups were the same as or greater than those in the intact group (Mg: 90 mg/100 g diet), the maximum load and elastic modulus were significantly reduced in the 3-mg-Mg group. In experiment 2, 4-week-old Wistar rats were fed a 6-mg-Mg diet for 8 weeks, and the effect of ALN (2, 20, and 200 microg/kg twice a week) was evaluated. The administration of ALN at 200 microg/kg increased the cortical bone mineral content (CtBMC), CtTh, and maximum load, but had no effect on the elastic modulus, as compared with the low-Mg-control group. In experiment 3, the effect of MK-4 was evaluated under the same conditions as in experiment 2. The administration of MK-4 had no effect on CtBMC, CtTh, or bone components of the femoral diaphysis. However, MK-4 inhibited the decreases in maximum load and elastic modulus due to the low-Mg diet. Since there is no other experimental model in which there is a decrease in bone mechanical properties without a decrease in bone mineral content, the low-Mg diet model is considered to be an excellent model for examining bone quality. Our results from this model suggest that MK-4 and ALN affect bone mechanical properties by different mechanisms.

Alendronate↗

Micromechanical properties of epiphyseal trabecular bone and primary spongiosa around the physis: an in situ nanoindentation study.

The elastic modulus and hardness of the mineralized bone around the growth plate was measured to determine its regional micromechanical properties. Multiple nanoindentation tests, >10 sessions, with depths ranging from 100 to 1,000 nm at loading rates of 12.5 and 750 microN/s, were performed on the trabecular bone in the epiphysis, trabecular bone at the junction of the physis and epiphysis, primary spongiosa in the metaphysis, and surrounding cortical bone of the distal femur of 300-gm Sprague-Dawley rats. The indentation load-displacement data obtained in these tests were analyzed to determine the elastic modulus and hardness of the tissues. The nanoindentation results highlighted the regional variations in the material properties of the mineralized tissues around the growth plate. The primary spongiosa had a lower elastic modulus and hardness than both epiphyseal trabecular and cortical bone (p < 0.01). A relatively well-defined thick trabecular band at the physeal-epiphyseal junction had modulus and hardness values comparable to those of cortical bone (p > 0.05). These findings support the hypothesis that the primary spongiosa has micromechanical properties that are significantly lower than the epiphyseal trabecular bone. On this basis, it is speculated that the fracture patterns commonly seen in patients with physeal injuries are influenced by the micromechanical properties of these tissues, as well as by the nature and direction of the applied force.

Analysis of Variance↗

Influence of preparative procedures on the membrane viscoelasticity of human red cell ghosts.

The effects of systematic variations in the preparative procedures on the membrane viscoelastic properties of resealed human red blood cell ghosts have been investigated. Ghosts, prepared by hypotonic lysis at 0 degrees C and resealing at 37 degrees C, were subjected to: measurement of the time constant for extensional recovery (tc); measurement of the membrane shear elastic modulus (mu) via three separate techniques; determination of the membrane viscosity (eta m) via a cone-plate Rheoscope. Membrane viscosity was also determined as eta m = mu X tc. Compared to intact cells, ghosts had shorter tc, regardless of their residual hemoglobin concentration (up to 21.6 g/dl). However, prolonged exposure to hypotonic media did increase their recovery time toward the intact cell value. The shear elastic modulus, as judged by micropipette aspiration of membrane tongues (mu p), was similar for all ghosts and intact cells. This result, taken with the tc data, indicates that ghosts have reduced membrane viscosity. Rheoscopic analysis also showed that eta m was reduced for ghosts, with the degree of reduction (approx. 50%) agreeing well with that estimated by the product mu p X tc. However, flow channel and pipette elongation estimates indicated that the ghost membrane elastic modulus was somewhat elevated compared to intact cells. We conclude that: ghosts have reduced membrane viscosity; ghosts have membrane rigidities close to intact cells, except possibly when the membrane is subjected to very large strains; the reduction in eta m is not directly related to the loss of hemoglobin; prolonged exposure of ghosts to low-ionic strength media increases the membrane viscosity toward its initial cellular level. These data indicate that the mechanical characteristics of ghost membranes can be varied by changing the methods of preparation and thus have potential application to further studies of the structural determinants of red cell membrane viscoelasticity.

Blood Specimen Collection↗