PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fracture Fixation, Intramedullary”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

The use of customized long stem hemiarthroplasty in ipsilateral femoral neck and pending shaft fracture: case report.

Most orthopaedic units do not have long stem femoral hemiarthroplasty prosthesis in their inventory. Situations that require replacement of the femoral head and internal fixation of the ipsilateral femoral shaft include femoral neck and shaft fracture as a result of either trauma or metastasis. The author reports on one technique of solving this problem by the use of an Austin-Moore hemiarthroplasty in combination with a half sawed Gross-Kempf (GK) intramedullary nail. The length of the GK nail was tailored according to the measured femoral length. The two implants were then impacted with a 4 cm overlap. Additional security was provided by the tension band wire placed between one of the distal locking holes in the nail and the hole in the Austin-Moore' implant and tunneled through the intramedullary nail.

Aged↗

Open fractures and infection.

Open fractures still represent a major challenge for the treating surgeon and frequently demand a complex of soft tissue and bone procedures to achieve an undisturbed healing with adequate limb function. However, despite improvement in operative techniques and antibiotic therapy septic complications still occur in severe open fracture forms up to 50%. They are still deleterious for the patient as well as a major economic factor for the treating hospital. Radical (repetitive) debridement of the wound and coverage of soft tissue defects are of utmost importance in the prophylaxis of septic complications along with antibiotic therapy. If the local wound requires flap coverage, early performed procedures yield a clear decrease of infection rates even in most severe fracture forms. Osseous stabilization contributes to infection prophylaxis, especially when the implants can be inserted in a minimal invasive way and provide an adequate handling of soft tissues and the wound. Thus, most often intramedullary nails and external fixators are used today for osteosynthesis. Recently developed plates with angular stability offer a promising alternative even in open fractures, especially when there is an extension of the fracture into the meaphyseal area though indications have to be evaluated. Manifest septic complications demand an early and aggressive approach with radical eradication of the septic topic. While acute infections require most often only minor surgical procedures and offer the chance to leave implants in situ, chronic infections usually demand complex reconstructive measures of bones and soft tissues.

Debridement↗

Delayed internal fixation of femoral shaft fractures--is there an advantage? A review of 320 fractures.

We have reviewed 402 traumatic fractures of the femoral shaft, 320 of which had been treated by operation and had a long follow-up. Of these, 228 closed fractures and 37 open fractures had been stabilised by plating. There was no significant difference in healing between those stabilised early and those having delayed internal fixation. Re-fracture after removal of the implant occurred more often after early operation. All 55 fractures treated by intramedullary nailing healed and there were no re-fractures after nail removal. We found no correlation between delay before operation and the incidence of postoperative infection.

Adolescent↗

Deep infection and fracture healing in immediate and delayed locked intramedullary nailing for open femoral fractures.

Fifty-nine patients with 61 open femoral fractures were treated with immediate locked intramedullary (IM) nailing (group 1; n=15), delayed IM nailing following nonoperative treatment (group 2; n=42), and delayed IM nailing following external fixation (group 3; n=7). Sixteen fractures were Gustilo type I, 28 were type II, 7 were type IIIA, 6 were type IIIB, and 4 were type IIIC open fractures. Four (6.6%) deep infections occurred. Significant differences existed in the deep infection rate (DIR) between types I and II and all type III fractures (2.3% for types I and II versus 17.6% for type III). The deep infection rate did not differ significantly among the nailing groups (13.3%, 2.6%, and 15.3% for groups 1, 2, and 3, respectively), nor did the deep infection rate correlate with the degree of fracture comminution, the existence of polytrauma or polyskeletal trauma, or preexistence of superficial or pin-site infections. Seven (11.7%) of these fractures resulted in nonunion, excluding one secondary amputation; the nonunion rate correlated with fracture location. There were no significant differences in the mean fracture healing times between any of the nailing groups. These results suggest that IM nailing for the treatment of type III open femoral fractures should be considered carefully, regardless of whether it is performed immediately or delayed.

Adolescent↗

The use of the unreamed nail in tibial fractures with concomitant preoperative or intraoperative elevated compartment pressure or compartment syndrome.

Twelve patients with tibial shaft fractures and evidence of compartment syndrome or with documented elevated compartment pressures were treated with an unreamed locked intramedullary nail and a single-incision lateral four-compartment fasciotomy. There were six closed fractures and three grade I and three grade II open fractures. Ten fractures have achieved a solid union without shortening or significant angulation at an average follow-up of 8.1 months (range 4-26). Two patients were lost to follow-up. There were two delayed unions and one nonunion, all of which healed after additional treatment. Average time to tibial union was 5.8 months (range 2-24), with six fractures healing in < or = 4 months. One patient whose treatment was delayed > 12 h after his injury has a persistent neurologic deficit with a claw toe deformity. There were no superficial or deep infections. All patients obtained an excellent range of motion of the knee and ankle. Unreamed nailing of diaphyseal tibial fractures with an associated compartment syndrome provides optimal internal fixation while allowing excellent access for soft tissue care. We believe that the unreamed tibial nail, when combined with a single-incision, lateral, four-compartment fasciotomy, offers substantial advantage in the treatment of this injury, permitting optimal treatment of a difficult fracture and soft tissue injury.

Adult↗