PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Chemical cytometry on a picoliter-scale integrated microfluidic chip.

An integrated microfluidic device has been fabricated for analyzing the chemical contents of a single cell (chemical cytometry). The device is designed to accomplish four different functions: (i) cell handling, (ii) metering and delivering of chemical reagents, (iii) cell lysis and chemical derivatization, and (iv) separating derivatized compounds and detecting them by laser-induced fluorescence. These functions are accomplished with only two valves, formed by multilayer soft lithography. A new kind of three-state valve and a picopipette are described; these elements are crucial for minimizing the reaction volume and ensuring optimal shape of the channel for electrophoresis injection. By using these valves, a reaction volume of approximately 70 pl is achieved for the lysis and derivitization of the contents of a single Jurkat T cell (approximately 10 microm diameter). As a demonstration of the use of this integrated microfluidic device, electropherograms of amino acids from individual Jurkat T cells are recorded and compared with those collected from a multiple-cell homogenate.

Electrophoresis, Capillary↗

Nanoliter microfluidic hybrid method for simultaneous screening and optimization validated with crystallization of membrane proteins.

High-throughput screening and optimization experiments are critical to a number of fields, including chemistry and structural and molecular biology. The separation of these two steps may introduce false negatives and a time delay between initial screening and subsequent optimization. Although a hybrid method combining both steps may address these problems, miniaturization is required to minimize sample consumption. This article reports a "hybrid" droplet-based microfluidic approach that combines the steps of screening and optimization into one simple experiment and uses nanoliter-sized plugs to minimize sample consumption. Many distinct reagents were sequentially introduced as approximately 140-nl plugs into a microfluidic device and combined with a substrate and a diluting buffer. Tests were conducted in approximately 10-nl plugs containing different concentrations of a reagent. Methods were developed to form plugs of controlled concentrations, index concentrations, and incubate thousands of plugs inexpensively and without evaporation. To validate the hybrid method and demonstrate its applicability to challenging problems, crystallization of model membrane proteins and handling of solutions of detergents and viscous precipitants were demonstrated. By using 10 microl of protein solution, approximately 1,300 crystallization trials were set up within 20 min by one researcher. This method was compatible with growth, manipulation, and extraction of high-quality crystals of membrane proteins, demonstrated by obtaining high-resolution diffraction images and solving a crystal structure. This robust method requires inexpensive equipment and supplies, should be especially suitable for use in individual laboratories, and could find applications in a number of areas that require chemical, biochemical, and biological screening and optimization.

Crystallization↗

A configurable three-dimensional microenvironment in a microfluidic channel for primary hepatocyte culture.

We have developed a technique for the in situ three-dimensional (3D) immobilization of primary rat hepatocytes within a localized matrix in a microfluidic channel that provides a 3D microenvironment incorporating both a configurable 3D matrix and fluid perfusion. This is based on the laminar flow complex coacervation of a pair of oppositely charged polyelectrolytes, i.e., methylated collagen and a terpolymer of HEMA-MMA-MAA. 3D collagen matrices were formed with minimal gelation times (<8 min), were able to entrap cells under aqueous noncytotoxic conditions, and permitted culture media to be perfused in the microchannel by virtue of the spatial confinement of the 3D matrix on one side of the channel. The architecture and stability of the collagen matrix could be configured by the use of different material combinations and changes in the polyelectrolyte flow rates and retention time. Primary rat hepatocytes cultured for 24 h in the 3D matrix within the microchannel showed comparable or enhanced cytochrome P450 7-ethoxyresorufin-O-deethylation activity with static controls. The configurable 3D microenvironment in the microfluidic channel may be a potential 3D culture model of primary hepatocytes for drug testing applications.

Animals↗

Microfluidic device reads up to four consecutive base pairs in DNA sequencing-by-synthesis.

We have developed the first fully integrated microfluidic system for DNA sequencing-by-synthesis. Using this chip and fluorescence detection, we have reliably sequenced up to 4 consecutive bps. The described sequencer can be integrated with other microfluidic components on the same chip to produce true lab-on-a-chip technology. The surface chemistry that was designed to anchor the DNA to elastomeric microchannels is useful in a broad range of studies and applications.

Base Pairing↗

Microfluidic PicoArray synthesis of oligodeoxynucleotides and simultaneous assembling of multiple DNA sequences.

Large DNA constructs of arbitrary sequences can currently be assembled with relative ease by joining short synthetic oligodeoxynucleotides (oligonucleotides). The ability to mass produce these synthetic genes readily will have a significant impact on research in biology and medicine. Presently, high-throughput gene synthesis is unlikely, due to the limits of oligonucleotide synthesis. We describe a microfluidic PicoArray method for the simultaneous synthesis and purification of oligonucleotides that are designed for multiplex gene synthesis. Given the demand for highly pure oligonucleotides in gene synthesis processes, we used a model to improve key reaction steps in DNA synthesis. The oligonucleotides obtained were successfully used in ligation under thermal cycling conditions to generate DNA constructs of several hundreds of base pairs. Protein expression using the gene thus synthesized was demonstrated. We used a DNA assembly strategy, i.e. ligation followed by fusion PCR, and achieved effective assembling of up to 10 kb DNA constructs. These results illustrate the potential of microfluidics-based ultra-fast oligonucleotide parallel synthesis as an enabling tool for modern synthetic biology applications, such as the construction of genome-scale molecular clones and cell-free large scale protein expression.

Base Sequence↗

Microfluidic devices for continuous blood plasma separation and analysis during pediatric cardiopulmonary bypass procedures.

As an extension of previous work, a microfluidic device, which can separate blood plasma in a continuous, real-time fashion from a whole blood, is successfully integrated with a mock cardiopulmonary bypass circuit. The functionality of the device is demonstrated with the use of freshly harvested bovine blood. The plasma selectivities were 100% and 99.4% and the plasma separation volume percents were 18.7% and 24.5% for 26% and 37% inlet hematocrit levels, respectively. As an advanced stage of this research, a microfluidic device, which can measure the concentration of clinically relevant blood plasma protein in a continuous fashion, is being developed on the basis of fluid handling circuits coupled to fluorescent cytometric bead assays. The functionality of the device is demonstrated with the use of a biotinylated FITC solution and a streptavidin-coated, 8-mum-diameter bead. The binding event between biotinylated FITC and the streptavidin bead is continuously detected within a detection window at the outlet of the device. For a known concentration (1 microg/ml) of biotinylated FITC solution, the measured fluorescent intensity is fairly constant and shows a stable gaussian distribution of the bead fluorescence intensity. It is expected that the proposed device can be used for continuous measurement of clinically relevant proteins during cardiac surgery with the cardiopulmonary bypass procedure.

Animals↗

Microfluidic mixers: from microfabricated to self-assembling devices.

This paper begins with a survey of both passive and active microfluidic mixers that have been implemented in recent years. It then describes a micromixing device based on dynamic self-assembly. This device is easy to fabricate and has excellent working characteristics in the continuous-flow mode. The paper concludes with a brief discussion of possible applications of self-assembly in microfluidics.

Complex Mixtures↗

Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets.

This paper reviews work on a microfluidic system that relies on chaotic advection to rapidly mix multiple reagents isolated in droplets (plugs). Using a combination of turns and straight sections, winding microfluidic channels create unsteady fluid flows that rapidly mix the multiple reagents contained within plugs. The scaling of mixing for a range of channel widths, flow velocities and diffusion coefficients has been investigated. Due to rapid mixing, low sample consumption and transport of reagents with no dispersion, the system is particularly appropriate for chemical kinetics and biochemical assays. The mixing occurs by chaotic advection and is rapid (sub-millisecond), allowing for an accurate description of fast reaction kinetics. In addition, mixing has been characterized and explicitly incorporated into the kinetic model.

Complex Mixtures↗

DNA mapping using microfluidic stretching and single-molecule detection of fluorescent site-specific tags.

We have developed a rapid molecular mapping technology--Direct Linear Analysis (DLA)--on the basis of the analysis of individual DNA molecules bound with sequence-specific fluorescent tags. The apparatus includes a microfluidic device for stretching DNA molecules in elongational flow that is coupled to a multicolor detection system capable of single-fluorophore sensitivity. Double-stranded DNA molecules were tagged at sequence-specific motif sites with fluorescent bisPNA (Peptide Nucleic Acid) tags. The DNA molecules were then stretched in the microfluidic device and driven in a flow stream past confocal fluorescence detectors. DLA provided the spatial locations of multiple specific sequence motifs along individual DNA molecules, and thousands of individual molecules could be analyzed per minute. We validated this technology using the 48.5 kb lambda phage genome with different 8-base and 7-base sequence motif tags. The distance between the sequence motifs was determined with an accuracy of +/-0.8 kb, and these tags could be localized on the DNA with an accuracy of +/-2 kb. Thus, DLA is a rapid mapping technology, suitable for analysis of long DNA molecules.

Bacteriophage lambda↗

Semiphenomenological model for the dispersion of DNA during electrophoresis in a microfluidic array of posts.

A lattice Monte Carlo model is proposed for quantifying the dispersion of DNA during microfluidic electrophoresis in a quasiperiodic array of posts similar to that encountered in the microfluidic self-assembly of magnetic bead columns. The transport model is semiphenomenological in the sense that all parameters, such as the post geometry, average collision time, and collision probability, are assumed to be accessible either directly from experiment or from a model of the microscale physics. Asymptotically exact formulas are obtained for the mean velocity and dispersivity using Taylor-Aris dispersion theory, which permits a straightforward analysis of the separation efficiency. The model is applicable to a variety of situations involving collision-retardation processes.

Complex Mixtures↗

Crystallizing proteins on the basis of their precipitation diagram determined using a microfluidic formulator.

Crystallization of proteins from a purified protein solution remains a bottleneck in the structure determination pipeline. In this paper the crystallization problem is addressed using a microfluidic device capable of determining detailed protein precipitation diagrams using less than 10 microL of protein sample. Based on the experimentally determined protein phase behavior, a crystallization screen can be designed to accommodate the physical chemistry of the particular protein target. Such a tailor-made crystallization screen has a high probability of yielding crystallization hits. The approach is applied to two different proteins: the calcium pump (SERCA), an eukaryotic integral membrane protein, and UMP kinase, a prokaryotic soluble kinase. Protein phase behavior is mapped for both proteins and tailor-made crystallization screens are designed for the two proteins resulting in about 50% crystallization probability per experiment. This illustrates the power of using microfluidic devices for detailed characterization of protein phase behavior prior to crystallization trials.

Animals↗

Model neural prostheses with integrated microfluidics: a potential intervention strategy for controlling reactive cell and tissue responses.

Model silicon intracortical probes with microfluidic channels were fabricated and tested to examine the feasibility of using diffusion-mediated delivery to deliver therapeutic agents into the volume of tissue exhibiting reactive responses to implanted devices. Three-dimensional probe structures with microfluidic channels were fabricated using surface micromachining and deep reactive ion etching (DRIE) techniques. In vitro functional tests of devices were performed using fluorescence microscopy to record the transient release of Texas Red labeled transferrin (TR-transferrin) and dextran (TR-dextran) from the microchannels into 1% w/v agarose gel. In vivo performance was characterized by inserting devices loaded with TR-transferrin into the premotor cortex of adult male rats. Brain sections were imaged using confocal microscopy. Diffusion of TR-transferrin into the extracellular space and uptake by cells up to 400 microm from the implantation site was observed in brain slices taken 1 h postinsertion. The reactive tissue volume, as indicated by the presence of phosphorylated mitogen-activated protein kinases (MAPKs), was characterized using immunohistochemistry and confocal microscopy. The reactive tissue volume extended 600, 800, and 400 microm radially from the implantation site at 1 h, 24 h, and 6 weeks following insertion, respectively. These results indicate that diffusion-mediated delivery can be part of an effective intervention strategy for the treatment of reactive tissue responses around chronically implanted intracortical probes.

Animals↗

Two simple and generic antibody-independent kinase assays: comparison of a bioluminescent and a microfluidic assay format.

In this study, the authors have compared the performance of 2 high-throughput screening assays for a serin/threonine kinase: a microplate-based, bioluminescent assay that uses the luciferin/luciferase system to monitor ATP consumption, and a microfluidic assay that measures the change in mobility in an electric field of a fluorescently labeled peptide upon phosphorylation. Both assays are homogeneous, nonradioactive, antibody independent and could be miniaturized to a reaction volume of 4 microl. The robustness of both formats was demonstrated by Z' values > 0.8. Screening of a small library (2133 compounds) showed that the results obtained with both technologies correlate very well. Although the threshold for hits was set to a comparably low value-22.2% and 13.7% inhibition for the ATP consumption and microfluidic assay, respectively, corresponding to mean plus 3 standard deviations-the overlap of active compounds identified with the 2 assay formats was greater than 94%. Thus, both assays allow the identification of even low potency inhibitors with a high level of confidence.

Adenosine Triphosphate↗

Integrated bioassays in microfluidic devices: botulinum toxin assays.

A microfluidic assay was developed for screening botulinum neurotoxin serotype A (BoNT-A) by using a fluorescent resonance energy transfer (FRET) assay. Molded silicone microdevices with integral valves, pumps, and reagent reservoirs were designed and fabricated. Electrical and pneumatic control hardware were constructed, and software was written to automate the assay protocol and data acquisition. Detection was accomplished by fluorescence microscopy. The system was validated with a peptide inhibitor, running 2 parallel assays, as a feasibility demonstration. The small footprint of each bioreactor cell (0.5 cm2) and scalable fluidic architecture enabled many parallel assays on a single chip. The chip is programmable to run a dilution series in each lane, generating concentration-response data for multiple inhibitors. The assay results showed good agreement with the corresponding experiments done at a macroscale level. Although the system has been developed for BoNT-A screening, a wide variety of assays can be performed on the microfluidic chip with little or no modification.

Biological Assay↗

Differentiation of mouse p19 embryonic carcinoma stem cells injected into an empty zebrafish egg chorion in a microfluidic device.

Mouse P19 embryonic carcinoma (EC) stem cells were xenotransplanted into the emptied chorion, the transparent envelope of a fertilized zebrafish egg (rather than mouse native zona pellucida) combined with a microfluidic device to study P19 EC cell differentiation in the chorion biomaterial. A distilled-water jet was used to remove the innate yolk and perivitelline inner mass from the chorion. P19 EC cells were injected into the emptied chorion using a micropipette, and they were subsequently cultured until the inner space of the chorion became completely occupied by cells. A simple microfluidic device was used for handling convenience and effective experiment. At d15, we found neural cells in the outer layer of the cell mass and beating cardiomyocytes in the inner layer of the large embryoid body. We propose that even though the species are different, the external innate membranes developed for embryo protection represent a useful type of ECM.

Animals↗

Analysis of passive mixing behavior in a poly(dimethylsiloxane) microfluidic channel using confocal fluorescence and Raman microscopy.

Confocal fluorescence microscopy (CFM) and confocal Raman microscopy (CRM) have been applied to monitor the laminar flow mixing behavior in a poly(dimethylsiloxane) (PDMS) microfluidic channel. Two passive PDMS micromixing devices were fabricated for this purpose: a two-dimensional round-wave channel and a three-dimensional serpentine channel. The microscale laminar flow mixing of ethanol and isopropanol was evaluated using the CFM and CRM at various flow rates. The mixing behavior of confluent streams in the microchannel was assessed by determining the degree of color change in Rhodamine 6G dye on mixing using the CFM. However, it was also possible to quantitatively evaluate the mixing process without employing a fluorescence label using the CRM. The results show a strong potential for CRM as a highly sensitive detection tool to measure fundamental fluid mixing processes and to provide detailed information on chemical changes of non-fluorescent reaction mixtures in a PDMS microfluidic channel.

2-Propanol↗

Quantitative analysis of methyl parathion pesticides in a polydimethylsiloxane microfluidic channel using confocal surface-enhanced Raman spectroscopy.

A fast and ultra-sensitive trace analysis of methyl parathion pesticides in a polydimethylsiloxane (PDMS) microfluidic channel was investigated using confocal surface-enhanced Raman spectroscopy (SERS). A three-dimensional PDMS-based passive micromixer was fabricated for this purpose. This PDMS micromixer showed a high mixing efficiency because a strong chaotic advection was developed by the simultaneous vertical and transverse dispersion of the confluent streams. The confocal SERS signal was measured after methyl parathion pesticides were effectively adsorbed onto silver nanoparticles while flowing along the upper and lower alligator-teeth-shaped PDMS channel. A quantitative analysis of the methyl parathion pesticides was performed based on the measured peak height at 1246 cm-1. Our method has a detection limit of 0.1 ppm. This value satisfies the requirement recommended by the Collaborative International Pesticides Analytical Council (CIPAC) for the determination of methyl parathion in pesticide formulations. This study demonstrates the feasibility of using confocal SERS for the highly sensitive detection of methyl parathion pesticides in a PDMS microfluidic channel.

Calibration↗

Contraction study of a single cardiac muscle cell in a microfluidic chip.

This chapter introduces a microfluidic method to study the contraction of a single cardiac muscle cell (cardiomyocyte). This method integrates single-cell selection, cell retention, dye loading, chemical stimulation, and fluorescence measurement for intracellular calcium on one microfluidic chip. Before single-cell experiments, the bonded chip was modified in order to make the channel deep enough to accommodate a large, single cardiomyocyte. After the modification, a single heart muscle cell could be selected and retained at a cell retention structure. Fluo-4 AM was loaded in the cell for the measurement of intracellular calcium ion concentration in the cell. Subsequently, caffeine was introduced into the chamber to induce the contraction of the cardiomyocyte. During contraction, fluorescence measurement was used to monitor the intracellular calcium level,and an optical imaging system was used to monitor the shape to confirm the contraction. The resting [Ca2+]i of cardiomyocyte was determined and was consistent with the value of approx 100 nM in the literature.

Aniline Compounds↗