PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polyurethanes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

New methods for the assessment of in vitro and in vivo stress cracking in biomedical polyurethanes.

This article describes a new test method for the assessment of the severity of environmental stress cracking of biomedical polyurethanes in a manner that minimizes the degree of subjectivity involved. The effect of applied strain and acetone pre-treatment on degradation of Pellethane 2363 80A and Pellethane 2363 55D polyurethanes under in vitro and in vivo conditions is studied. The results are presented using a magnification-weighted image rating system that allows the semi-quantitative rating of degradation based on distribution and severity of surface damage. Devices for applying controlled strain to both flat sheet and tubing samples are described. The new rating system consistently discriminated between the effects of acetone pre-treatments, strain and exposure times in both in vitro and in vivo experiments. As expected, P80A underwent considerable stress cracking compared with P55D. P80A produced similar stress crack ratings in both in vivo and in vitro experiments, however P55D performed worse under in vitro conditions compared with in vivo. This result indicated that care must be taken when interpreting in vitro results in the absence of in vivo data.

Biocompatible Materials↗

Hydrophilic hybrid IPNs of segmented polyurethanes and copolymers of vinylpyrrolidone for applications in medicine.

The preparation and biocompatibility properties of thermoplastic apparent interpenetrating polymer networks (T-IPNs) of a segmented polyurethaneurea, Biospan (BS), and vinylpyrrolidone-dimethylacrylamide (VP-DMAm) copolymers, are described. The biological interaction between the obtained materials and blood was studied by in vitro methods. The addition of the VP-DMAm copolymers to form T-IPNs with BS substantially increased the equilibrium water uptake and water diffusion coefficients. Investigation of the proteins adsorption, platelet adhesion, thrombus formation and factor XII activation is presented. Investigations of the proteins adsorption of the BS/VP-DMAm T-IPNs surfaces show that the segmented polyurethane (BS) containing VP-DMAm copolymers with higher VP content adsorb more albumin than fibrinogen and gamma-globulin. The platelets adhesion, thrombus formation and factor XII activation are effectively suppressed with respect to the segmented polyurethane when VP-DMAm copolymers with high VP contents are incorporated into BS as T-IPNs.

Adsorption↗

The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants.

We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.

Animals↗

Enzyme induced biodegradation of polycarbonate-polyurethanes: dose dependence effect of cholesterol esterase.

The current study has investigated the influence of esterase activity (80-400units/ml) on the biodegradation of polycarbonate-urethanes (PCNUs) by cholesterol esterase (CE), with a particular interest in studying the influence of different hard segment structures and their contribution to sensitizing the polymer towards enzyme catalyzed hydrolysis. Polycarbonate based polyurethanes were synthesized with varying hard segment content as well as hard segment chemistry based on three different diisocyanates, 1,6-hexane diisocyanate (HDI), 4,4'-methylene bisphenyl diisocyanate (MDI) and 4,4-methylene biscyclohexyl diisocyanate (HMDI). The effect of different chemistry on surface contact angle was measured in order to define the relative chemical nature of the surfaces. The enzyme dose response was found to be lower when hard segment content in the polymer was high. There was a very strong dependence on enzyme concentration for polyurethanes with different hard segment chemistry, despite the fact that the nature of the hydrolysable polycarbonate segment remained the same. The PCNU which showed the most dramatic dependence on enzyme concentration was synthesized with HMDI. At low enzyme concentration (80units/ml) this material was the most stable of the polymers while at elevated CE concentration (400units/ml) the polymer underwent a catastrophic breakdown. The findings suggested that protein binding on the surfaces was saturated even though enzyme degradation did not achieve saturation on any of the surfaces. The role of protein binding in modulating the hydrolytic action of the enzymes at different activity levels highlights a need for further study in this area.

Cyanates↗

Isolation of methylene dianiline and aqueous-soluble biodegradation products from polycarbonate-polyurethanes.

Polycarbonate-polyurethanes (PCNUs) have provided the medical device industry with practical alternatives to oxidation-sensitive polyether-urethanes (PEUs). To date, many studies have focused on PCNUs synthesized with 4,4'-methylene diphenyl-diisocyanate (MDI). The relative hydrolytic stability of this class of polyurethanes is actually quite surprising given the inherent hydrolytic potential of the aliphatic carbonate group. Yet, there has been little information reporting on the rationale for the material's demonstrated hydrolytic stability. Recent work has shown that PCNU materials have a strong sensitivity towards hydrolysis when changes are made to their hard segment content and/or chemistry. However, knowledge is specifically lacking in regards of the identification of cleavage sites and the specific nature of the biodegradation products. Using high-performance liquid chromatography, radiolabel tracers and mass spectrometry, the current study provides insight into the distribution of biodegradation products from the enzyme-catalyzed hydrolysis of five different PCNUs. The hydrolytic sensitivity of the materials is shown to be related to the distribution of products, which itself is a direct consequence of unique micro-structures formed within the different materials. While an MDI-based polymer was shown to be the most hydrolytically stable material, it was the only PCNU that produced its diamine analog, in this case 4,4'-methylene dianiline (MDA), as a degradation product. Given the concern over aromatic diamine toxicity, this finding is important and highlights the fact that relative biostability is a distinct issue from that of degradation product toxicity, and that both must be considered separately when assessing the impact of biodegradation on biomaterial in vivo compatibility.

Aniline Compounds↗

Vascugraft polyurethane arterial prosthesis as femoro-popliteal and femoro-peroneal bypasses in humans: pathological, structural and chemical analyses of four excised grafts.

Following positive results obtained in in vitro studies and in vivo implantations in animals, a clinical trial using the Vascugraft polyurethane arterial prosthesis as a below-knee substitute was undertaken in 15 patients. Eight grafts became occluded during the first year, and segments from four of them were explanted and made available for pathological, structural and chemical investigations. The implantation periods ranged from 21 to 358 days. Failures were associated with kinking (one case), possible anastomotic mismatch between the graft and the artery (one case), and poor run-off (two cases). No organized collagenous internal encapsulation was noted; however, endothelial-like cells were observed at the anastomotic site of one graft. No significant structural degradation of the prostheses was observed in those grafts implanted for 21, 38 and 46 days. Some deteriorations in the fibrous structure were observed on the external surface of the prosthesis implanted for 358 days. High-resolution carbon C1s analysis by ESCA demonstrated a 60 to 80% decrease in carbonate content on the surface of all explanted prostheses. Chemical analyses of each polyurethane graft by IR, SEC and DSC revealed no significant chemical changes. The clinical performance of the Vascugraft prosthesis for below-knee implantation proved to be no more impressive than that of expanded polytetrafluorethylene, the currently accepted reference. The decision by B. Braun Melsungen AG to end this program is therefore to be regarded as highly professional.

Aged↗

Photo-immobilization of dipyridamole (Persantin) at the surface of polyurethane biomaterials: reduction of in-vitro thrombogenicity.

Dipyridamole is a well-known vasodilator and a powerful inhibitor of activation and aggregation of blood platelets. Moreover, dipyridamole is essentially non-toxic. The drug is used extensively in clinical anti-coagulation regimes, for example pre- and post-coronary angioplasty procedures. Recently, we have found that photochemical, covalent coupling of dipyridamole to polyurethane surfaces leads to improved thromboresistance in vitro. This phenomenon is now studied in more detail. Both qualitative and more quantitative biochemical experiments were performed in order to characterize the in vitro blood compatibility of a set of polyurethane surfaces onto which dipyridamole was immobilized. First, scanning electron microscopy was used to examine the morphology of platelets which adhered during incubation with platelet-rich plasma. These experiments showed that immobilization of dipyridamole leads to a clearly decreased number of adherent platelets and to a largely diminished propensity of the surface to activate adherent platelets. Secondly, an in vitro thrombogenicity assay was run. These experiments showed that the thromboresistance increased with increasing surface density of immobilized dipyridamole. A short spacer chain separating dipyridamole from the polymer surface, was found to improve the thromboresistance further. Such a spacer chain apparently increases the efficacy of the immobilized drug. Collectively, the present results further substantiate the idea that dipyridamole retains its inhibitory activity with respect to activation and aggregation of blood platelets, when the compound is covalently attached to a polymer surface. The possible utility of these findings with respect to the development of an artificial blood vessel prosthesis is discussed briefly.

Biocompatible Materials↗

In vitro blood compatibility of functional group-grafted and heparin-immobilized polyurethanes prepared by plasma glow discharge.

Blood compatibilities of functional group-grafted and heparin-immobilized polyurethanes (PUs) were investigated using in vitro thrombus formation, plasma recalcification time (PRT), activated partial thromboplastin time (APTT), platelet adhesion and activation, and peripheral blood mononuclear cell (PBMC) activation. In the experiment with plasma proteins, PRT was shortened on amine group-grafted PU (PU-NH2) but prolonged on heparin-immobilized polyurethane (PU-Hep) when compared to PU control. APTT was significantly prolonged on PU-Hep, suggesting the binding of immobilized heparin to antithrombin III. The percentage of platelet adhesion was slightly increased by the introduction of functional groups such as carboxylic acid and primary amine on PU surfaces, but significantly decreased by the immobilization of heparin on the same substrate. The percentage of serotonin released from platelets adhered on surface-modified PUs was increased with increase of platelet adhesion. In the PBMC experiment, cells adhered less on heparin-immobilized PUs than on functional group-grafted PUs, and the production levels of tumour necrosis factor mRNAs from the cells stimulated by heparin-immobilized PU (PU-N-Hep) were smaller than those by the other substrates.

Amines↗

Manufacturing and microscopical characterisation of polyurethane nerve guidance channel featuring a highly smooth internal surface.

The present study demonstrates the possibility of manufacturing polyurethane [ChronoFlex (CF)] nerve guidance channels (NGCs) featuring a highly smooth internal surface. Comparative SEM and AFM observations prove marked differences between the internal surface microgeometry of Silastic and CF channels. SEM of CF samples shows a surface with no detectable roughness, while Silastic channels show transversal rows along the entire surface. AFM digital image of Silastic samples show a surface with a rough microgeometry defined by a tridimensional pattern with peaks up to 1400 nm. AFM digital image of CF samples show, indeed, an essentially flat microgeometry with the highest level at 545 nm. These preliminary results suggest that the association of an innovative sequential deposition manufacturing technique with the new CF polyurethane may produce NGCs with a smoother surface microgeometry, in comparison to NGCs obtained from commercial Silastic tubes.

Biocompatible Materials↗

Adsorption from plasma and buffer of single- and two-chain high molecular weight kininogen to glass and sulfonated polyurethane surfaces.

The adsorption of high molecular weight kininogen (HK) in its single-chain (SCHK) and two-chain (TCHK) forms from single protein solutions, plasma, and kininogen-deficient plasma, to glass and sulfonated polyurethane surfaces is reported. Using radiolabelling methods, it was found that in a single protein buffered system there was no difference in the adsorbed amounts of SCHK and TCHK over the concentration range 5-100 microg ml(-1) (similar to that in plasma). The adsorption of the two forms from normal plasma was also the same. However, immunoblots using an anti-HK antibody indicated that over the 2 h adsorption time, much of the SCHK present in the plasma was converted to TCHK: the band at 120 kD representative of intact SCHK disappeared, and bands at 56 and 46 kD representative of the heavy and light chains of TCHK were generated. To prevent conversion of SCHK to TCHK, the kallikrein inhibitor aprotinin (or in some cases a protease inhibitor cocktail), was added to the plasma in subsequent experiments. In addition, kininogen-deficient plasma was used (with either labelled SCHK or TCHK added) to avoid ambiguity in the tracer-population relationship. It was again found that there was no difference in the amounts of SCHK and TCHK adsorbed to glass and the sulfonated polyurethanes. The significance of these findings in relation to the reported anti-cell adhesion properties of adsorbed HK is discussed.

Adsorption↗

Surface characterization and platelet adhesion studies on polyurethane surface immobilized with C60.

Due to its distinctive molecular configuration, C60 and its derivatives have been the research focus in exploring its electrical, mechanical, optical, and even biological applications during the past decades. In this investigation, C60 molecules are grafted onto the polyurethane surface, which is pretreated with oxygen plasma activation, through amine-terminated silane coupling agents. ESCA analysis indicates that the C60 molecules spontaneously grafted onto the amine-terminated PU substrate through nucleophilic additions to the fullerene double bonds which fuse two six-membered rings. More amine functional groups are formed on the PU surface if 4-aminobutyldimethylmethoxysilane is used as the coupling agent. In vitro platelet adhesion assay shows the C60 grafted PU are more platelets activating than the nontreated PU control. This might be attributed to the synergistic effect of the grafted C60 molecules and the few residual amine functional groups which are left after the C60 grafting reaction. Further applications using these C60 grafted polyurethane surfaces as the cell adhesion and cell growth substrates are currently under exploration.

Amines↗

Polydimethylsiloxane/polyether-mixed macrodiol-based polyurethane elastomers: biostability.

A series of four thermoplastic polyurethane elastomers were synthesized with varying proportions of poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols. The macrodiol ratios (by weight) employed were (% PDMS:% PHMO) 100:0, 80:20, 50:50 and 20:80. The weight fraction of macrodiol in each polymer was fixed at 60%. The mixed macrodiols were reacted with 4,4'-methylenediphenyl diisocyanate (MDI) and 1,4-butanediol (BDO) chain extender. The biostability of these polymers was assessed by strained subcutaneous implantation in sheep for three months followed by microscopic examination. Pellethane 2363-80A and 2363-55D were employed as control materials. The mechanical properties of the polymers were tested and discussed along with the biostability results. The results showed that soft, flexible PDMS-based polyurethanes with very promising biostability can be successfully produced using the mixed macrodiol approach. The formulation with 80% PDMS macrodiol produced the best result in terms of a combination of flexibility, strength and biostability.

Biocompatible Materials↗

Polyurethane coatings release bioactive antibodies to reduce bacterial adhesion.

This study describes the formulation of a biomedical grade polyurethane hydrogel coating containing solid dispersed bioactive antibodies cast from an organic solvent onto a model polymer biomaterial substrate. A prepolymer dispersion in anhydrous isopropanol containing a uniformly distributed slurry of 22 microm sieved commercial lyophilized polyclonal pooled human immunoglobulin G (IgG) solids was coated onto polymer substrates by simple immersion. Maximum antibody release was approximately 50 microg/cm(2) from a 15% w/w IgG polymer coating. In vitro antimicrobial studies utilized Escherichia coli to compare performance of bare uncoated tubing, hydrogel-coated tubing with added aqueous phase antibodies, and antibody-dispersed hydrogel-coated tubing. Bacterial adhesion was reduced significantly (p<0.05) in the presence of antibodies with the greatest reduction seen with the antibody releasing coating. The presence of antibody also significantly enhanced the killing of the bacteria in an in vitro opsonophagocytic assay using freshly isolated blood neutrophils over 2 h indicating that antibody bioactivity is maintained. This controlled release polyurethane hydrogel coating imparts infection resistance by exploiting the low adhesive properties of the biomedical grade hydrogel and the intrinsic bioactive role of the antibodies to reduce bacterial adhesion and promote clearance via natural immune mechanisms.

Antibodies, Bacterial↗

High-performance liquid chromatographic separation and tandem mass spectrometric identification of breakdown products associated with the biological hydrolysis of a biomedical polyurethane.

As part of ongoing investigations into the biological degradation of biomaterials, methods have been developed to isolate and chemically analyze polymer biodegradation products. The use of these methods can provide information on the biodegradation product profiles and yield concentration levels for the isolated products. The latter information is required to assess the toxicological nature of biomaterials and their related degradation products. In this study a model biomedical polyurethane was synthesized with toluene diisocyanate, polyester diol and ethylene diamine, and then incubated at 37 degrees C in a biological solution containing enzyme. The biodegradation products were isolated from the in vitro system and prepared for HPLC analysis, by using a combination of ultrafiltration, freeze drying and liquid-solid extraction. The ultrafiltration and the liquid-solid extraction effectively removed protein contamination. The separation of more than 20 degradation products, with gradient HPLC, was optimized using a photodiode array detector. The separated degradation products were identified using a tandem mass spectrometer. The model polyurethane was labeled with 14C in different segments, in order to assist in confirming the efficiency of the sample preparation and isolation methods. A detection limit of 2 ng was found. No toluene diamine - a suspected human carcinogen associated with some medical implants - could be found in the test samples. This represents a significant finding since the amount of this injected sample actually contained a total of 28 microg of degradation products isolated from the incubation medium.

Biocompatible Materials↗

Hydrogen cyanide and carbon monoxide in blood of convicted dead in a polyurethane combustion: a proposition for the data analysis.

Carbon monoxide is a well-known toxic component in fire atmospheres. However, the importance of hydrogen cyanide as a toxic agent in fire causalities is under discussion. A tragic polyurethane mattress fire provoked death of 35 convicts in a prison (Unit I, Olmos, Penitenciary Service of Buenos Aires Province, Argentina), in 1990. There is no report of any investigation carried out with such a large amount of victims in Argentina. Carboxihemoglobin (COHb) and hydrogen cyanide (HCN) were quantified in victims blood to elucidate the cause of the death. Saturation of COHb ranged between 4 and 18%, and HCN 2.0-7.2mg/l. These latter values were higher than the lethal levels reported in literature. Other toxic components routinely measured (ethanol, methanol, aldehydes and other volatile compounds) gave negative results on the 35 cases. Neither drugs of abuse nor psychotropics were detected. Statistical chi(2) analysis was applied to find differences between HCN and COHb concentrations. Saturation of COHb and HCN in blood were not independent variables (chi(2)=8.25). Moreover, the ratio COHb/HCN was constant (0.47+/-0.04). In order to evaluate the contribution of each toxic to the diagnosis, a lethal index was defined for each toxic (LI(CO) and LI(HCN)). The most probable cause of death could be inferred by a suitable plot of both indexes. The results indicated that death in the 35 fire victims was probably caused by HCN, generated during the extensive polyurethane decomposition provoked by a rapid increase of temperature.

Argentina↗

Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene.

PURPOSE: Synthetic grafts have been increasingly used for complex vascular reconstructions in patients with limited autologous vein availability. Materials currently in use induce increased stenosis and graft thrombosis compared with autologous vein, especially in smaller vessels. We examined whether grafts constructed of a porous biodegradation-resistant polycarbonate polyurethane (PU) exert better biocompatibility in terms of faster endothelialization and decreased chronic proliferation of intimal cells compared with expanded polytetrafluoroethylene (ePTFE). METHODS: PU or ePTFE interposition grafts were implanted into the abdominal aortas of male Sprague-Dawley rats (PU, n = 37; ePTFE, n = 32). Grafts were removed at days 1, 7, 14, 28, and 56 and 6 months and were evaluated by immunohistochemical, electron microscopic, and morphometric techniques. Bromodeoxyuridine (BrdU) was injected at 1 and 24 hours before death to determine cellular proliferation. Endothelial cells and smooth muscle cells were identified with antibodies to von Willebrand factor and alpha-actin, respectively. RESULTS: The luminal surface of PU grafts took 4 weeks to completely endothelialize, whereas ePTFE grafts took 24 weeks (P <.05). Neointimal cell proliferation was lower in PU grafts compared with ePTFE at 56 days (1.4 +/- 0.1 versus 8.6 +/- 1.5, P <.001) and at 6 months (0.15 +/- 0.002 versus 3.4 +/- 0.5, p <.001). Neointimal thickness at 6 months after implantation was 3.2 +/- 0.8 micrometer for PU compared with 10.3 +/- 3.1 micrometer for ePTFE (P <.05). CONCLUSION: Polycarbonate polyurethane small vascular prostheses promoted faster luminal endothelialization, induced less chronic intimal proliferation, and produced a significantly thinner neointima than ePTFE grafts. These findings suggest that aliphatic-polycarbonate urethanes may offer advantages over standard materials such as ePTFE for vascular graft construction.

Animals↗

[Polyurethane catheters and antineoplastic chemotherapy. An experimental study].

An in vitro study of the effect of cytotoxic drugs on polyurethane catheters was carried out. The drugs used--vincristine, doxorubicin, cisplatin and carmustine--damage the surface of silicone elastomer catheters. The irregularities produced seem to be preferential sites for thrombus formation and adhesion of bacterial microcolonies. Electron microscopy examination of the catheters dipped in the drug solutions for different time intervals revealed the appearance of different patterns of damage. The irregularities produced seemed to be less pronounced than for silicone catheters. Polyurethane was highly sensitive to doxorubicin. These changes could well have clinical repercussions. The compatibility of catheters and drugs should be routinely tested before being put on the market.

Antineoplastic Combined Chemotherapy Protocols↗

Long-term patency of regenerated neoaortic wall following the implant of a fully biodegradable polyurethane prosthesis: experimental lipid diet model in pigs.

The degradation of a polyurethane vascular prosthesis, the time course and characteristics of tissue ingrowth and prosthesis replacement, and the incidence of thrombosis have been investigated in 50 young pigs. A 6-7 cm long cone-shaped prosthesis was implanted in the infrarenal aorta of 50 young growing pigs which were sacrificed at intervals from 60 to 365 days. Ten animals were controls, 25 were given aspirin 10 mg/kg of body weight/day, and 15 were fed with cod liver oil. Aortography, done at 30, 60, and 90 days, showed 100% of implants were thrombosed in the surviving controls, 55% of the aspirin group had patent grafts, and 100% of animals in the lipid diet group had patent grafts. At final graft retrieval, the aspirin group showed only three patencies, while in the lipid diet group seven out of nine animals were patent. The laboratory and morphological studies indicated that all patent prostheses were lined with tissue that resembled the intima of native aorta with a layer of smooth muscle cells which appeared complete at 180 days. From these data we conclude that the biodegradable polyurethane vascular prosthesis is reliable for experimental implants in a pig model. The lipid-rich diet of polyunsaturated fatty acids potentiates long-term patency, perhaps by preventing platelet aggregation and thrombosis, and allowing the growth of a neoendothelium and neomedia within the lumen of the prosthesis, which slowly degrade towards fatty tissue and form neoadventitia.

Animals↗