PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “The Right to Reproduce”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Amygdala fMRI lateralizes temporal lobe epilepsy.

OBJECTIVE: To characterize the clinical value of an fMRI task activating the amygdala in controls and patients with mesial temporal lobe epilepsy (MTLE). METHODS: A fearful face fMRI paradigm using video sequences was developed and investigated in 17 patients with epilepsy (12 had MTLE [6 right- and 6 left-sided]) and 17 healthy control subjects. Reproducibility was demonstrated by reimaging 12 of the control subjects. In addition, parahippocampal activation was measured using Roland's Hometown Walking Task within the same session in all patients and in nine of the control subjects. RESULTS: A fearful face paradigm led to significant amygdala activation (p < 0.001) in all subjects. Amygdala activation was bilateral in control subjects and clearly lateralized in patients with MTLE. Dissociated amygdala and parahippocampal activation was found in three MTLE patients. A combination of results from both fMRI paradigms improved the lateralization of the side of seizure onset in patients with MTLE. CONCLUSIONS: fMRI activation of the amygdala evoked by an animated fearful face paradigm is strong, reproducible, and specific in individual subjects. The combination of the fearful face paradigm and Roland's Hometown Walking Task provides a more reliable presurgical mapping of mesial temporal lobe structures.

Adolescent↗

Effect of the 30 degree lateral recumbent position on pulmonary artery and pulmonary artery wedge pressures in critically ill adult cardiac surgery patients.

BACKGROUND: Despite demonstrated benefits of lateral positioning, critically ill patients may require prolonged supine positioning to obtain reproducible hemodynamic measurements. OBJECTIVES: TO determine the effect of 30 degree right and left lateral positions on pulmonary artery and pulmonary artery wedge pressures after cardiac surgery in critically ill adult patients. METHODS: An experimental repeated-measures design was used to study 35 patients with stable hemodynamics after cardiac surgery. Subjects were randomly assigned to 1 of 2 position sequences. Pulmonary artery and pulmonary artery wedge pressures were measured in each position. RESULTS: Measurements obtained from patients in the 30 degree left lateral position differed significantly (all Ps < .05) from measurements obtained from patients in the supine position for pulmonary artery systolic, end-diastolic, and mean pressures. Pulmonary artery wedge pressures did not differ significantly; however, data were available from only 17 subjects. The largest mean difference in pressures between the 2 positions was 2.0 +/- 2.1 mm Hg for pulmonary artery systolic pressures, whereas maximum differences for end-diastolic and pulmonary artery wedge pressures were 1.4 +/- 2.7 mm Hg and 1.6 +/- 2.4 mm Hg, respectively. Clinically significant position-related changes in pressure occurred in 12 (2.1%) of 581 pressure pairs. Clinically significant changes occurred in end-diastolic pressure in 2 subjects and in pulmonary artery wedge pressure in 1 subject. CONCLUSIONS: In patients with stable hemodynamics during the first 12 to 24 hours after cardiac surgery, measurements of pulmonary artery and pulmonary artery wedge pressures obtained in the 30 degree lateral and supine positions are clinically interchangeable.

Adult↗

[Correlation between nasal polyposis and perennial allergy exemplified by house dust mite and house dust allergy].

A total of 139 patients with nasal polyps were investigated by a standardized history, intradermal skin test and nasal challenge to house dust mite allergy. The aim of the study was to assess the disputed role of perennial allergy in patients with nasal polyps using allergens to the house dust mite as an example. Using our diagnostic criteria we found allergy to house dust mite in 28% of all cases. We found this diagnosis in 44.8% of patients aged 10-39. We recommend, especially in this age group, an allergy test, if necessary with the appropriate therapy. Test correlations are illustrated in 174 patients who have been examined by the above methods. Good reproducibility was found by the nasal challenge, which led to the right diagnosis in 92%, compared with 81% by a standardized history. Therefore, it can be considered to be the key to the diagnosis of allergy.

Adolescent↗

[The distance between the terminal hinge position and the intercuspation position in the temporomandibular joint area].

In 117 subjects with normal TMJs, the distance between most retruded contact position and maximum intercuspation was measured both extraorally by means of a kinematic face bow and intraorally with a ruler. The mean distance between most retruded contact position and maximum intercuspation was 0.5 +/- 0.3 mm on the right side and 0.5 +/- 0.4 mm on the left side. The reproducibility of the measurements was better than 0.3 mm (0.2 +/- 0.1 mm) in 80% of the subjects. Statistically, there was no correlation between the amount of sliding and vertical overlap. For practical purposes, the following conclusions can be drawn: 1. Retruded contact position and maximum intercuspation are well reproducible reference positions of the mandible. 2. Retruded contact position is very close to maximum intercuspation in most people. Therefore it can be used as a "therapeutic compromise" for occlusal rehabilitation. 3. There is no indication that a deep vertical overlap would lock the mandible in a dorsal position. 4. When using the "freedom in centric" concept, the occlusal range is about 0.5 mm.

Dental Articulators↗

[Hypersensitivity and carotid sinus syndrome in patients with chronic atrial fibrillation].

BACKGROUND: Carotid sinus hypersensitivity (CSH) has always been described in patients in sinus rhythm; we did not find reports of CSH in patients with chronic atrial fibrillation (AF). After the observation of bilateral CSH in a patient with chronic AF admitted to our Division for syncope, we began to systematically study patients with chronic AF and neurological disturbances to evaluate carotid sinus stimulation effects upon cardiac activity and arterial blood pressure in these subjects. METHODS: We studied 28 subjects with chronic AF (mean age 73.3 yrs.; range 60-89): 16 patients had dizziness, fainting or syncope, and formed the study group (A); 12 asymptomatic patients were considered the control group (B). After a careful clinical and instrumental evaluation, all the patients underwent a 24 hour ambulatory (Holter) ECG analysis and right and left carotid sinus massage (CSM). If the latter manoeuvre induced asystolia longer than 3 seconds, CSM was repeated during ventricular pacing to evaluate the vasal component of the carotid sinus reflex. RESULTS: In group A, 24-hour Holter monitoring showed a greater incidence (81.2%) of ventricular standstill (mean duration 2.67 seconds) in comparison to the control group. In group A we found CSH in 75% of the cases, more frequently right CSH (7 subjects with right, 1 with left and 4 with bilateral CSH) with prolonged ventricular asystolia (mean duration 5.3 +/- 1.9 sec. with right CSM; 7.8 +/- 1.4 sec. with left CSM); during CSM, we reproduced spontaneous symptomatology in 9 patients. In 12 patients in group A, diagnosis of carotid sinus syndrome was established; the cardioinhibitory forms were clearly prevalent (91.7%); only one patient presented a cardioinhibitory-vasodepressor form with a predominant vasodepressor component. CONCLUSIONS: The authors believe that CSH is frequent in patients with chronic AF; the vagal hyperactivity due to CSH can induce prolonged ventricular asystole that may be responsible for neurological disturbances such as dizziness, fainting or syncope, as observed in patients in sinus rhythm with carotid sinus syndrome. Abnormal sensitivity of the carotid sinus could thus be one of the causes of increased morbidity and mortality in patients with chronic AF. The majority of these patients may be expected to benefit from permanent pacemaker therapy.

Aged↗

Measurement of right ventricular ejection fraction by contrast echocardiography.

We evaluated 20 healthy subjects with no cardiac disease (8 males, 12 females, age 49+/-12) to determine the accuracy of right ventricular ejection fraction measurement with contrast echocardiography performed with D-galactose (Echovist 300). All patients underwent two dimensional echocardiography where the right ventricular ejection fraction was calculated by the Simpson's rule first without contrast, then after the injection of 5 ml D-galactose in the same position and compared to the right ventricular ejection fraction measured by the first pass radionuclide angiography on the same day. Subjects had a normal left ventricular ejection fraction of 66+/-5 and a body mass index of 28.9+/-1.2. The correlation between echocardiographic and radionuclide derived right ventricular ejection fraction significantly increased when contrast was used (r=0.81 vs. r=0.6). The r value for interobserver variability also increased significantly with contrast use (r=0.98 vs. r=0.7). We conclude that D-galactose contrast injection significantly enhances border detection and improves the accuracy of right ventricular ejection fraction calculations with echocardiography making it a simple and reliable method.

Adult↗

Limited benefit of septal pre-excitation in pace prevention of atrial fibrillation.

BACKGROUND: Pre-excitation of the intra-atrial septum (IAS) by pacing at the ostium of the coronary sinus (CSO) can prevent atrial fibrillation (AF) in case of single atrial premature beats (APBs). We investigated whether pre-excitation of IAS, either by pacing at CSO or at the right ventricle in the presence of retrograde conduction (RV), can prevent atrial tachyarrhythmia triggered by single and multiple APBs. AF vulnerability was compared to pacing at the right atrium (RA) and sinus rhythm (SR). METHODS: Seventeen patients, age 52 +/- 21 years, who exhibited retrograde VA conduction and reproducible induction of atrial tachyarrhythmia during an electrophysiological procedure, were studied. Both during SR and pacing (S1-S1:600 ms) at RA, CSO, and right ventricle (RV), single (A1-S2:200 ms) and multiple premature stimuli (A1-S2-S3-S4:200-180-180 ms) were delivered at RA (4 x diastolic threshold). RESULTS: During pacing at RA, single and multiple APBs invariably induced runs of atrial tachyarrhythmia (mean duration 34 +/- 67 sec and 37 +/- 69 sec, range 1 sec to 20 min). During preventive pacing at CSO and RV, single APBs (A1-S2:200 ms) did not induce atrial arrhythmia (0 +/- 0 sec, 0 +/- 0 sec, P < 0.05 vs pacing at RA). In contrast, when multiple APBs were applied, pacing at CSO or RV failed to prevent initiation of AF (mean duration 36 +/- 63 sec, 38 +/- 65 sec, NS). Also during SR, single APBs did not induce AF (0 +/- 0 sec, P < 0.05 vs pacing at RA) whereas multiple APBs invariably induced AF (39 +/- 74 sec, NS). CONCLUSIONS: Compared to pacing at RA, pre-excitation of IAS either by pacing at CSO or at RV with retrograde conduction can prevent initiation of paroxysms of atrial tachyarrhythmia triggered by single but not by multiple right APBs. These findings imply that the potential benefit of choosing an optimal pacing site in patients requiring atrial-based pacing is limited. Moreover, in the absence of bradycardia, no specific pacing site offers incremental benefit over the natural "protective" effect of sinus rhythm.

Adult↗

Pulmonary hypertension: echocardiographic assessment.

Pulmonary arterial hypertension (PAH) is a clinical condition characterized by elevated vascular resistance, associated with a poor prognosis and usually diagnosed in late stage. Echocardiographic assessment of PAH includes early disease detection and functional heart evaluation, in order to introduce a more accurate surveillance at an early stage of the disease and to contribute to prognostic stratification of advanced disease. Detection involves pulmonary artery systolic pressure (PASP) estimation. There is no clear consensus on defining normal distribution, but a PASP of 36 mmHg has been widely assumed as a cut-off value for mild PAH, requiring a more aggressive surveillance to detect further progression. Functional heart evaluation requires an accurate characterization of morphologic and hemodynamic changes, secondary to PAH development, which involves description of dimensional parameters, ventricular interdependency, intracardiac flow patterns, and right ventricular systolic performance. A valid assessment of these issues results in a useful evaluation of cardiac function, supporting clinical context in defining heart failure condition.

Echocardiography↗

Echocardiography for hemodynamic assessment of patients with advanced heart failure and potential heart transplant recipients.

OBJECTIVES: This study sought to assess the accuracy of Doppler echocardiographic techniques for the determination of right heart catheterization hemodynamic variables in patients with advanced heart failure and in potential heart transplant recipients. BACKGROUND: Doppler echocardiographic techniques permit the noninvasive acquisition of hemodynamic variables traditionally used for the assessment of patients with advanced heart failure and potential heart transplant candidates. However, the accuracy of these techniques has not been sufficiently well documented for clinical application in individual patients. METHODS: Echocardiographic data required for estimation of mean right atrial, pulmonary artery and mean left atrial pressures and cardiac output were obtained. Right heart catheterization was performed immediately after Doppler echocardiographic data were acquired, before any intervention that might have altered the subject's hemodynamic status. RESULTS: A complete Doppler echocardiographic hemodynamic data set was acquired in 21 (84%) of 25 subjects. For all variables, invasive and noninvasive hemodynamic values were highly correlated (p < 0.001), with minimal bias and narrow 95% confidence limits. An algorithm constructed from the noninvasive hemodynamic variable values identified all patients with adverse pulmonary vascular hemodynamic variables (i.e., transpulmonary gradient > or = 12 mm Hg, pulmonary vascular resistance > or = 3 Wood units or pulmonary vascular resistance index > or = 6 Wood units x m2). This algorithm identified 12 (71%) of 19 patients for whom right heart catheterization was unnecessary. CONCLUSIONS: Doppler echocardiographic estimates of hemodynamic variables in patients with advanced heart failure are accurate and reproducible. This noninvasive methodology may assist with monitoring and optimization of medical therapy in patients with advanced heart failure and may obviate the need for routine right heart catheterization in potential heart transplant candidates.

Algorithms↗

Evaluation of left and right ventricular functional parameters with automatic edge detection program of ECG gated blood SPET.

An analysis program for ECG gated, blood pool, single photon emission tomography (SPET GBP) is available. This program permits the automatic evaluation of left and right ventricular function, but its reliability has not been thoroughly assessed. The objective of this investigation was to examine the reliability of the parameters derived from SPET GBP. Fifty-three patients who had undergone both SPET GBP and planar, ECG gated, blood pool scintigraphy (planar GBP) were enrolled in the study. Planar GBP was performed with a single-headed gamma camera. From a left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG gating during the equilibrium state. SPET GBP was carried out utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees, with 60 s per view, in 16 frames/cardiac cycle. Left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) were calculated by using the analysis program. The reproducibility of these values and the correlation between SPET and planar GBP were assessed. To evaluate the effect of cut-off frequencies of a Butterworth filter, six different cut-off frequencies (order=8, 0.3-1.0 Nyquist) were tested with data obtained from 12 patients. The reproducibility of LVEF by SPET GBP was satisfactory (intra-observer, r=0.95; inter-observer, r=0.96), whereas reproducibility of RVEF by SPET GBP was fair (intra-observer, r=0.83; inter-observer, r=0.83). LVEF with SPET GBP was well correlated (y=1.1x+6.62, r=0.85, P<0.01) with LVEF readings of planar GBP. However, LVEF with SPET GBP was overestimated (mean difference of 12) in comparison with that of planar GBP. The RVEF derived from SPET GBP showed poor correlation (y=0.52x+33, r=0.53, P<0.01) with planar GBP. No significant effect of cut-off frequencies of Butterworth filters was evident in the calculation of LVEF and RVEF (P=0.48 and 0.67) with SPET GBP. It is concluded that SPET GBP with QBS is useful for the evaluation of LVEF. However, measurement of the RVEF showed lower reproducibility compared with measurement of the LVEF.

Adolescent↗

Children's errors in copying angles: perpendicular error or bisection error?

Following Piaget and Inhelder's work, considerable evidence has accrued showing that young children have difficulty constructing the horizontal and vertical in particular drawing tasks. However, one recent study by Ibbotson and Bryant interpreted these difficulties as lying with angle reproduction rather than representation of horizontal and vertical. Their conclusion was that children of 3 to 5 years distort acute angles to look more like right angles. A study is reported which tests the hypothesis that this is a particular case of a general tendency to bisect angles. The results support this hypothesis. 5-year-old children reproduced bisected figures accurately, but distorted nonbisected figures towards bisection, despite the fact that they contained a right angle. The simplest interpretation is that children's representations of the figures are distorted: either locally, by angle bisection, or by increasing symmetry of the figure as a whole. One puzzling result emerged. The bisection effect only appeared with oblique-baseline figures. The tentative interpretation is that, when the baseline is horizontal or vertical, children can easily note that nonbisected figures are asymmetrical about vertical or horizontal axes, and hence resist the tendency to distort representations towards symmetry.

Art↗

Diagnosis of suspected Alzheimer's disease is improved by automated analysis of regional cerebral blood flow.

PURPOSE: Accurate diagnosis of Alzheimer's disease (AD), the most common form of dementia, remains difficult. In order to assess whether fully automated stereotactic surface projection (3D-SSP) presentation contributes to the diagnosis of AD by single-photon emission computed tomography (SPECT), we investigated the diagnostic accuracy of transaxial display with and without 3D-SSP analysis as well as the correlation between cerebral perfusion in different cortical areas and the mini mental score (MMS). METHODS: Seventy-two patients referred because of cognitive impairment were included in the study. According to the National Institute of Neurological and Communicative Disorders and Stroke (NINCDS) and the Alzheimer's disease and Related Disorders Association (ADRDA) criteria, 27 patients were diagnosed as having probable AD while 45 were classified as non-AD patients. 3D-SSP was used to quantify the regional cerebral blood flow (rCBF) acquired from SPECT imaging. RESULTS: Compared with the transaxial section presentation alone, 3D-SSP presentation improved the area under the receiver operating curve (p<0.05) as well as intra-observer (k=0.73 vs 0.88) and inter-observer (k=0.50 vs 0.84) reproducibility. Upon normalisation of regional to thalamic activity, multiple regression analysis revealed a strong correlation between the MMS and rCBF in the right parietal cortex (p=0.002). CONCLUSION: Addition of 3D-SSP to the transaxial section display of ECD-SPECT studies improves the reproducibility and the diagnostic performance in respect of AD in patients with cognitive impairment and provides a valid tool for assessment of the severity of cortical perfusion abnormalities in such patients.

Adult↗

Measurement of ejection fraction by thermal dilution techniques.

The reproducibility, accuracy, and clinical applicability of ventricular ejection fraction derived by a thermal dilution technique were assessed in 22 dogs and 18 patients. Results obtained by the thermal technique were compared to simultaneous results obtained by radionuclide angiography. Right ventricular ejection fraction, measured in 9 dogs (1014 determinations) and 8 patients (744 determinations) was reproducible +/- 5%. Left ventricular ejection fraction, measured in 10 patients, was reproducible +/- 5%. Correlation between thermal and radionuclear measurements varied from 0.86 to 0.93 (all P less than 0.02). We conclude that, because of its low cost, ease of use, and accuracy, thermally derived ejection fraction determinations can be helpful in hemodynamic monitoring of critically ill patients.

Angiography↗

Measurement of anterior-posterior displacement of the knee. A comparison of the results with instrumented devices and with clinical examination.

Thirteen subjects who had normal knees and fifteen patients who had a chronic rupture of the anterior cruciate ligament were tested in order to compare the measurements of tibiofemoral displacement as recorded by four commercial devices: the Acufex knee-signature system, the Genucom knee-analysis system, the Medmetric KT-1000 arthrometer, and the Stryker knee-laxity tester. Anterior and posterior displacement were measured at forces of eighty-nine newtons (twenty pounds) and 133 newtons (thirty pounds). We found significant differences in reproducibility of measurement among the devices. The Acufex, Medmetric, and Stryker devices had more reproducible measurements, and they could be used to identify 80 to 90 per cent of the normal subjects and anterior cruciate-deficient patients. The Genucom device had poorer reproducibility of measurement, and it tended to register greater differences in displacement between the right and left knees of normal subjects.

Adult↗

Impaired joint proprioception in patients with cervical myelopathy.

STUDY DESIGN: Prospective clinical study. OBJECTIVES: To evaluate impairment of proprioception quantitatively in patients with cervical myelopathy. SUMMARY OF BACKGROUND DATA: Sensory information regarding proprioception ascends through the posterior columns in the spinal cord. Damage to these columns causes proprioceptive loss in patients with spondylotic myelopathy. Nevertheless, there have been few studies regarding proprioception in patients with myelopathy. METHODS: The authors evaluated knee proprioception in 54 cervical myelopathy patients and compared results with those of 54 age-matched healthy volunteers. Knee proprioception was assessed by joint position sense, represented by the error angles when patients reproduced predetermined angles of knee flexion. RESULTS: The average absolute angle error of right and left knee with the predetermined position of 30 degrees of knee flexion was 2.5 +/- 1.8 (mean +/- standard deviation) and 1.8 +/- 1.2 degrees and with the predetermined 60 degrees of flexion, 4.7 +/- 2.8 and 2.8 +/- 1.4 degrees in the myelopathy and control groups, respectively. The average absolute angular errors in the myelopathy group were significantly higher than those in the control group for each predetermined knee position (P < 0.01). CONCLUSIONS: Proprioceptive ability is impaired in patients with cervical myelopathy. Position sense can be assessed by measuring the angular error when reproducing criterion positions, and the results may reflect the severity of cervical myelopathy. Thus, the present method of measuring proprioception is easy to perform and useful for quantitative assessment of the severity of cervical myelopathy.

Adult↗

Use of infrared emission detection thermometer in Chinese neonates.

OBJECTIVE: To evaluate the reproducibility of Thermoscan, an infrared emission detection ear thermometer, and to establish the normal reference range of ear temperature in Chinese neonates. METHODS: Neonates were recruited from the inpatients population with exclusion of those suffering from infections. RESULTS: Forty-nine neonates were recruited with 1,115 temperature taking sessions. Mean left ear temperature was 36.64 degrees C +/- 0.35 degree C. Mean right ear temperature was 36.64 degrees C +/- 0.37 degree C. Clinical repeatability for left and right ear was 0.17 degree C and 0.17 degree C, respectively. CONCLUSION: Thermoscan produced reproducible results in Chinese neonates. The normal range of ear temperature for Chinese neonates is 35 degrees C to 37 degrees C. Ear temperature > 37.8 degrees C should be regarded as fever.

Asian People↗

Monophasic action potentials in patients with coronary artery disease: reproducibility and electrical restitution and conduction at different stimulation rates.

Monophasic action potentials were recorded in the outflow tract of the right ventricle in patients with coronary artery disease during ventricular pacing at different basic cycle lengths and programmed stimulation. During continuous pacing (basic cycle length 600 ms) the time for 90% repolarisation (MAP90) and the QTa interval decreased exponentially during the first 1.5-2 min of pacing to 90% of control values. The reproducibility of the monophasic action potential signals and the ventricular effective refractory period were assessed as good when studied after repetitive trains of 8 beats for more than 1.5 min. The reproducibility of conduction, however, was less good. Electrical restitution of MAP90 duration of the premature beats determined at three different basic cycle lengths was different from that in single muscle preparations. The curves showed two phases with unchanged MAP90 durations despite longer coupling intervals. The first phase was close to the ventricular effective refractory period, probably because subnormal conduction left the diastolic interval constant for the earliest premature beats. This indicates that subnormal conduction may influence the premature dispersion of repolarisation.

Action Potentials↗

Monitoring of right ventricular function using a conventional slow response thermistor catheter.

OBJECTIVE: To investigate whether determination of right ventricular end-diastolic volume (RVEDV) and right ventricular ejection fraction (RVEF) can be performed with reasonable accuracy and reproducibility using a conventional slow response thermistor pulmonary artery catheter (CPAC) applying an adaptive algorithm. DESIGN: To study RVEDV and RVEF simultaneously with pulmonary artery catheters equipped with slow and fast response thermistors (FRPAC) under a broad range of cardiac output. SETTING: Laboratory of Institute of Experimental Surgery, Technical University. ANIMALS: 11 anaesthetised piglets. INTERVENTIONS: Hypovolemia (V-) was induced by withdrawal of blood up to 50 ml/kg, hypervolemia (V+) was produced by retransfusing blood and adding up to 30 mg/kg hydroxyethyl starch. In 5 animals in phases V- and V+ beta-adrenergic stimulation was achieved with dobutamine. Finally pulmonary artery hypertension was induced by infusion of small air bubbles. MEASUREMENTS AND RESULTS: Cardiac output (CO), RVEDV and RVEF were determined simultaneously with FRPAC and CPAC placed in the same pulmonary artery branch. Measurements were repeated 8 times sequentially in steady state normovolemia. A total of 130 measurements could be analysed. The coefficient of variation was 6.7 +/- 4.2% for CO(FRPAC) and 4.6 +/- 1.7% for CO(CPAC); for RVEF it was 9.7 +/- 6.2% (FRPAC) and 9.9 +/- 3.9% (CPAC); for RVEDV it was 11.6 +/- 4.8% (FRPAC) and 8.54 +/- 3.2 (CPAC). Mean difference (bias) was 0.06 +/- 0.39 l/min for CO measured with both methods, 19 +/- 35 ml for RVEDV and -3.3 +/- 6.5% for RVEF. CO(CPAC) displayed a strong correlation to CO(FRPAC) (R = 0.97, p = 0.001) as well as RVEF (R for RVEF(CPAC) versus RVEF(FRPAC) = 0.90, p = 0.001). R for RVEDV(CPAC) versus RVEDV(FRPAC) was 0.67, p = 0.001. We conclude that this animal study demonstrates good agreement between RVEF and RVEDV obtained with catheters equipped with a fast response thermistor or with a conventional slow response thermistor allowing accurate monitoring of right ventricular function with a conventional pulmonary artery catheter.

Algorithms↗