Multiomics: the intersection of personalized nutrition in cardiometabolic diseases.

BACKGROUND: Cardiometabolic diseases are among the leading causes of increasing morbidity and mortality worldwide. However, current population-based dietary recommendations do not sufficiently account for biological differences between individuals and therefore do not have the same effect on everyone. The multiomic approach, which incorporates genomic, epigenomic, transcriptomic, proteomic, metabolomic, and microbiome data, facilitates more accurate classification of disease risk and selection of appropriate nutritional interventions by mapping food-disease relationships across different biological layers. METHODS: Through a narrative synthesis of the current literature, we focused on evidence from multiomic studies to assess their ability to guide personalized nutrition strategies based on individual genetic, metabolic, and microbiome characteristics in cardiometabolic diseases. RESULTS: Recent evidence indicates that metabolomic markers have been reported to provide predictive value in addition to classic risk indicators and to increase the predictive power of models when combined with genetic data. Microbiome research shows that glycemic and lipemic responses can be predicted using algorithms based on gut microbiota. Recent clinical studies show that personalized nutrition plans, which evaluate the microbiome and clinical characteristics together, improve continuous glucose monitoring-based glycemic control, glycated hemoglobin levels, and triglycerides more than the classic Mediterranean diet. CONCLUSION: This review summarizes the current multiomic evidence, discusses the methodological and practical challenges in this field, and highlights future priorities. The integration of digital biomarkers obtained from wearable technologies with multiomic systems and artificial intelligence-supported models, when developed in accordance with ethical and equitable access principles, has the potential to support the transition from the discovery phase to patient-centered clinical applications.

Humans↗

Normalization of glycemia in diabetics during meals with insulin and glucagon delivery by the artificial pancreas.

An extracorporeal "closed-loop" system has been employed to maintain glycemia in the normal range during consumption of meals in nine insulin-treated diabetics. This artificial pancreas system incorporated continuous blood glucose monitoring (0.05 ml. per minute, delay time 90 seconds), a computer programed to respond to glycemia, and a hormone delivery system. Intravenous insulin delivery rates were determined by control parameters responsive to both glucose concentration and its rate of change. Because insulin-dependent diabetics often defend themselves poorly against hypoglycemia (in some cases due to inadequate glucagon responses), the instrument was also programed for exogenous glucagon delivery. A priori selection of ideal parameters for insulin and glucagon delivery for each individual is not yet possible. Consequently, when the parameters were used for the first time on each subject, they were varied over a reasonable range. This approach resulted in a corresponding variety of glycemic responses, the average of which characterized a set of initial parameters that is generally applicable. Appropriate control parameters are presented that successfully prevented hypoglycemia. Glucagon delivery directly related to glycemia appeared sufficient for this purpose, thus obviating the need for dextrose administration. This system provides a technique for complete normalization of blood glucose concentration in the types of diabetics tested, during both fed and interprandial periods. It has yielded insights essential to the development of more sophisticated future devices.

Adult↗

Randomized controlled clinical trial of glargine versus ultralente insulin in the treatment of type 1 diabetes.

OBJECTIVE: Multiple daily insulin injection programs are commonly accompanied by considerable glycemic variation and hypoglycemia. We conducted a randomized crossover design clinical trial to compare glargine with ultralente insulin as a basal insulin in type 1 diabetes. RESEARCH DESIGN AND METHODS: To determine whether the use of glargine insulin as a basal insulin would result in a comparable HbA1c and less glycemic variation and hypoglycemia than ultralente insulin, 22 individuals (aged 44 +/- 14 years [+/-SD], 55% men) with type 1 diabetes who were experienced with multiple daily insulin injections and had an HbA1c of <7.8% were randomized in a crossover design to receive either glargine or ultralente as the basal insulin for 4 months. Aspart insulin was used as the prandial insulin. Physicians providing insulin dose adjustment advice were masked to the type of basal insulin. RESULTS: Treatment with glargine resulted in lower mean HbA1c (6.82 +/- 0.13 vs. 7.02 +/- 0.13, difference: 0.2 +/- 0.08, P = 0.026), less nocturnal variability (plasma glucose 49.06 +/- 4.74 vs. 62.36 +/- 5.21 mg/dl, P = 0.04), and less hypoglycemia (24.5 +/- 2.99 vs. 31.3 +/- 4.04 events, P = 0.05), primarily due to less daytime hypoglycemia (P = 0.002). On the other hand, serious hypoglycemia and average glucose concentration measured with continuous subcutaneous glucose monitoring did not differ. CONCLUSIONS: We conclude that while use of either ultralente or glargine as a basal insulin can result in excellent glycemic control, treatment with glargine is associated with slightly but significantly lower HbA1c and less nocturnal glycemic variability and hypoglycemia.

Adult↗

Comparative study of NPH human insulin (recombinant DNA) and pork insulin in diabetic subjects: preliminary report.

Continuous blood glucose monitoring in six insulin-dependent diabetic patients shows that the biologic action of NPH human insulin (recombinant DNA) and pork insulin is similar. Nevertheless, the activity of NPH human insulin seems faster and more pronounced since minimal glycemia is lower and more rapidly reached after human insulin. The speed of glycemic increase is slightly lower and the decrease is faster with NPH human insulin; thus the area under the NPH human insulin-induced glycemic curve is less wide, but differences are not significant. Our data favor a faster and more potent effect of NPH human insulin.

Adolescent↗

Continuous maternal glucose measurements and fetal glucose and insulin levels after administration of terbutaline in term labor.

Maternal blood glucose and fetal blood glucose and insulin levels were studied in 16 women at full-term labor after administration of terbutaline 250 microgram i.v. The maternal blood glucose level was registered by a continuous blood glucose monitoring unit. In all patients studied, the terbutaline injection was followed by a rise in maternal blood glucose within 15 min, lasting for at least one hour. The fetal glucose levels paralleled those of the mothers, but on a lower level. None of the infants demonstrated hypoglycemia during the first 90 min after birth. We conclude that terbutaline administrated in this way has a direct effect on the maternal blood glucose release, and report that no harmful effects on fetal carbohydrate metabolism could be demonstrated.

Blood Glucose↗

2: Recent advances in therapy of diabetes.

As suboptimal blood glucose control has a lasting harmful effect even if control improves later, intensive insulin therapy to minimise hyperglycaemia is now recommended for all patients with type 1 diabetes. The new rapid- and long-acting insulin analogues offer more physiological insulin profiles than traditional insulin preparations. Continuous insulin infusion ("pump therapy") may provide a solution for some patients with frequent hypoglycaemia or hypoglycaemic unawareness. Continuous blood glucose monitoring reveals postprandial hyperglycaemia and asymptomatic nocturnal hypoglycaemia and may be especially useful for programming overnight basal insulin rates for pump therapy. In type 2 diabetes, management should change with disease progression; introduction of insulin should not be delayed if metabolic control becomes suboptimal.

Adolescent↗

[Experiments in evaluation of brain oxygenation and metabolism based on continuous bilateral SjO2 monitoring and metabolic glucose transformations in patients after severe cranio-cerebral injuries].

The study group consisted of 17 patients after severe cranio-cerebral injuries-in GCS below 8. Saturation in both jugular bulbs was measured by using fiberoptic catheters, the concentration of lactate taken from jugular bulbs was measured too. These values were compared to concentration in peripheral arteries. All measurements were started within the first 24 h after trauma and lasted 5 days. Diagnosis of intracranial pathology was established by using CT, which was done directly after admission to the hospital. Interdependence between the state of patient in GOS and variability saturation and concentration of lactate was showed. Desaturation occurred before the neurological sings of intracranial hypertension what had influence on way of treatment and diagnostics. Bilateral measurement of the saturation is more useful to make diagnostic unilateral measurement.

Adult↗

Hypoglycemia in diabetics.

Hypoglycemia in diabetes can be divided into 1) spontaneous hypoglycemic reactions due to absolute or relative overproduction of endogenous insulin or some other blood glucose-lowering substance, as in islet cell adenoma or carcinoma, latent or protodiabetic conditions, (extrapancreatic) tumors and pituitary and/or adrenal disorders; and 2) hypoglycemia caused by exogenous, i.e. therapeutic, measures. The problem of hypoglycemia in insulin-treated diabetics is far from being solved. As revealed by continuous blood glucose monitoring, nocturnal hypoglycemic attacks frequently escape attention especially in juvenile diabetics. Circadian variations in peripheral glucose utilization, rather than changes in plasma insulin activity, are likely to be involved in this mechanism. At least, this was the conclusion drawn from studies carried out by means of a glucose-controlled insulin and glucose infusion system (GCIGIS) -or artificial pancreas-which delivers short-acting insulin and glucose on demand intravenously. Hypoglycemic reactions in patients being treated with oral anti-diabetic agents, on the other hand, should be regarded primarily as one of the side reactions intrinsic to the mechanism of action of some of these drugs, e.g. sulfonylureas, which act mainly via stimulation of secretion of endogenous insulin reserves not responding properly to postprandial blood glucose increments. In the case of glibenclamide, at least partial resensitization of the defective glucose receptor of the beta-cell also becomes operative. A higher incidence of a characteristic type of hypoglycemic reaction was observed soon after glibenclamide therapy was introduced. Better understanding of the drug and dissemination of the information about it to doctors and patients has reduced the number of hypoglycemic reactions caused by glibenclamide to the same proportions as for other sulfonylureas. Hypoglyoemia following therapeutic hypophysectomy retains its position as one of the main hazards of this heroic therapy.

Adenoma, Islet Cell↗

Glucose tolerance and insulin and C-peptide responses after various insulin secretory stimuli in hyper- and hypothyroid subjects before and after treatment.

Immunoreactive insulin (IRI) and C-peptide secretory responses to terbutaline, glucagon, glucose and a standardized meal during continuous blood glucose monitoring were investigated in hyper- and hypothyroid patients before and after treatment. The beta 2-adrenoceptor agonist terbutaline (125 micrograms IV) induced prompt IRI and C-peptide responses in hyperthyroid patients. On the contrary, in the hypothyroid, no insulin or C-peptide responses were seen despite a slight enhancement of blood glucose concentrations. Thyroxine treatment of these patients improved the IRI and C-peptide responses and no blood glucose increment was then seen. Glucagon (250 micrograms IV) induced prominent IRI and C-peptide responses of similar magnitude in hyper- and hypothyroid patients before as well as after treatment. Before treatment, the blood glucose increment was greater in the hypothyroid patients than in the hyperthyroid but after treatment no difference between the 2 groups was seen. After a small load of glucose (6 g IV) no apparent difference in glucose tolerance was seen between hyper- and hypothyroid patients. However, the hyperthyroid patients had greater IRI and C-peptide responses to glucose than the hypothyroid but the differences diminished after treatment. Before treatment, hypothyroid patients had lower blood glucose response to a meal intake than hyperthyroid patients but no differences were seen between the 2 patient groups with regard to IRI- and C-peptide responses. After treatment, no differences between the 2 groups were seen with regard to blood glucose, IRI or C-peptide responses to the meal.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

[Artificial pancreas: study methods and control of glycemia equilibrium in diabetic patients].

The artificial endocrine pancreas or artificial beta cell, consists of a continuous blood glucose monitoring system, a computered set-up which responds to glycemia and the hormone delivery system. This system provides a technique which can completely normalize blood glucose concentration in diabetic patients, during both food assumption and after. This paper deals with the characteristics of the artificial beta cell, its possible applications and its limits.

Artificial Organs↗

[Post-hyperglycaemic hypoglycaemia: effects of somatostatin (author's transl)].

Precise recordings of reactive (post-hyperglycaemic) hypoglycaemia were ensured by continuous blood glucose monitoring during oral glucose tolerance tests. The definition of hypoglycaemia was limited to the following criteria: absence of chemical diabetes; fall in blood sugar to less than 30% of the fasting level or to less than 2.50 mmol/l (0.45 g/l); development of clinical signs of hypoglycaemia. An infusion of somatostatin over 4 hours slowed down the initial rise in blood sugar during the first 90 minutes and the rise was prolonged throughout the infusion whatever its duration. The maximum glycaemia reached was 13.3 mmol/l (2.40 g/l) at the 250th minute. Interruption of the infusion led to a rapid fall in blood sugar to a level identical (2.1 and 2.5 mmol/l) with and without somatostatin respectively. Somatostatin infusions, while frankly diabetogenic in certain circumstances, do not prevent reactive hypoglycaemia but rather delay its onset.

Adult↗

A new bioassay for insulin in conscious rabbits by continuous measurement of glycemic responses.

Because of the substantial variability often observed in the determination of insulin potency by the United States Pharmacopeia (USP) bioassay method, a large number of rabbits are required in order to attain an accuracy of +/- 6% and each bioassay needs 2-3 weeks to be completed. In this report, an improved bioassay method has been developed. This bioassay was conducted in conscious healthy rabbits. The decline in blood glucose levels, following intravenous injection of an insulin preparation, was monitored (in uninterrupted manner) by the continuous glucose monitoring system developed. A glucose response curve was generated, and from this response curve, various pharmacodynamic parameters were easily determined. The whole procedure could be completed in 1 day and also achieved an accuracy where upon only one rabbit is needed to determine accurately the insulin potency. To validate the method, a total of nine healthy rabbits were studied to determine the inter- and intra-animal reproducibility. The values of insulin potency determined from four pharmacodynamic parameters were compared, and the potency calculated from the ABGC (area of the blood glucose response curve under baseline) was found to be the most accurate: a mean (+/- SEM) value of 102.3(+/- 1.2)% was determined by inter-animal study (n = 9) and a value of 100.6(+/- 1.3)% by intra-animal study (n = 4). The inter-bioassay variability among the random-dose bioassays was 1.2% for inter-animal and 1.3% for intra-animal studies. The insulin potency in an insulin sample determined by this bioassay had attained an overall mean (+/- SEM) value of 101.6(+/- 0.8)% (n = 17).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.

OBJECTIVE: Hypoglycemia and wide glucose excursions continue to be major obstacles to achieving target HbA(1c) values and the associated reductions in long-term complications (and economic costs) in people with insulin-treated diabetes. In this study we evaluated the accuracy, safety, and clinical effectiveness of a continuous glucose-sensing device. RESEARCH DESIGN AND METHODS: A total of 91 insulin-requiring patients with type 1 (n = 75) and type 2 (n = 16) diabetes were enrolled in this multicenter randomized study. Subjects wore a transcutaneous, 3-day, continuous glucose-sensing system for three consecutive 72-h periods. Subjects were randomly assigned (1:1 ratio) to either a control group (continuous glucose data not provided) or a display group (continuous glucose data not provided during period 1 but displayed during periods 2 and 3). During periods 2 and 3, patients in the display group had real-time access to sensor glucose values, could review glucose trends over the preceding 1, 3, and 9 h, and were provided with high (> or = 200 mg/dl) and low (< or = 80 mg/dl) alerts and a low (< or = 55 mg/dl) alarm. Sensors were inserted by patients, and both groups used (or wore) the system during daily activities. Device accuracy was assessed by comparing continuous glucose values to paired self-monitoring of blood glucose (SMBG) meter readings. Clinical effectiveness was evaluated by analyzing between-group (control vs. display, periods 2 and 3) and within-group (display, period 1 vs. period 3) differences in time spent in high, low, and target (81-140 mg/dl) glucose zones. RESULTS: When prospective, real-time sensor values were compared with SMBG values, 95.4% of 6,767 paired glucose values fell within Clarke error grid A and B zones. Pearson's correlation coefficient was 0.88, and mean and median absolute relative differences were 21.2 and 15.9%, respectively. No systematic bias was detected at any of the prespecified glucose levels (50, 80, 100, 150, and 200 mg/dl). When compared with control subjects, the display group spent 21% less time as hypoglycemic (<55 mg/dl), 23% less time as hyperglycemic (> or = 240 mg/dl), and 26% more time in the target (81-140 mg/dl) glucose range (P < 0.001 for each comparison). Nocturnal (10:00 p.m. to 6:00 a.m.) hypoglycemia, as assessed at two thresholds, was also reduced by 38% (<55 mg/dl; P < 0.001) and 33% (55-80 mg/dl; P < 0.001) in the display group compared with control subjects. CONCLUSIONS: We conclude that real-time continuous glucose monitoring for periods up to 72 h is accurate and safe in insulin-requiring subjects with type 1 and type 2 diabetes. This study demonstrates that availability of real-time, continuously measured glucose levels can significantly improve glycemic excursions by reducing exposure to hyperglycemia without increasing the risk of hypoglycemia, which may reduce long-term diabetes complications and their associated economic costs.

Adult↗

Comparison of peripheral and portal routes of insulin infusion by a computer-controlled insulin infusion system (artificial endocrine pancreas).

This study was undertaken to determine the different consequences of portal and peripheral routes of insulin administration by the artificial endocrine pancreas. Intraportal glucose was infused (10 mg./min./kg. for 60 minutes) in anesthetized normal and pancreatectomized dogs while blood glucose concentrations were monitored continuously. During computer-controlled insulin administration normal glucose tolerance was restored by both portal and peripheral routes of insulin delivery. There were also no significant differences in (1) glycemic patterns, (2) insulin infusion patterns, (3) peripheral IRI levels, and (4) total insulin requirements between the two routes. It is apparent that the peripheral route, which is more readily accessible than the portal route, may be an appropriate infusion site for an implantable or portable prosthesis for controlling blood glucose concentration.

Animals↗

Sleepiness, performance, and neuroendocrine function during sleep deprivation: effects of exposure to bright light or exercise.

The temporal profiles of subjective fatigue (as assessed by the Stanford Sleepiness Scale), of cognitive performance (on a digit symbol substitution test and a symbol copying task), of body temperature, and of the peripheral concentrations of melatonin, thyroid-stimulating hormone (TSH), and cortisol were obtained simultaneously at frequent intervals in 17 normal young subjects submitted to a 43-h period of constant routine conditions involving continuous wakefulness at bed rest in dim indoor light. The subjects had knowledge of time of day. Caloric intake was exclusively in the form of an intravenous glucose infusion, and plasma glucose levels were monitored continuously in 8 of the 17 subjects. Under these conditions, fluctuations in plasma glucose reflect primarily changes in glucose use because endogenous glucose production is suppressed by the exogenous infusion. Following the completion of a baseline constant routine study, the volunteers participated in two subsequent studies using the same protocol to determine the immediate psychophysiological effects of exposure to a 3-h pulse of bright light or to a 3-h pulse of physical exercise. Sleepiness and performance varied in a mirror image, with significant negative correlations. Sleepiness scores were minimal around noon and then increased at a modest rate throughout the rest of the normal waking period. Staying awake during usual bedtime hours was associated with an acceleration in the rate of increase in sleepiness, which coincided with decreasing body temperature, rapidly rising cortisol concentrations, and maximal levels of melatonin and TSH. When body temperature reached its nadir, a further major increase in sleepiness occurred in parallel with a pronounced decrease in plasma glucose (reflecting increased glucose use). Recovery from maximal sleepiness started when blood glucose levels stopped falling and when significant decreases in cortisol and melatonin concentrations were initiated. Lower levels of subjective sleepiness resumed when glucose concentrations and body temperature had returned to levels similar to those observed prior to sleep deprivation and when melatonin and TSH concentrations had returned to daytime levels. The synchrony of behavioral, neuroendocrine, and metabolic changes suggests that circulating hormonal levels could exert modulatory influences on sleepiness and that metabolic alterations may underlie the sudden increase in fatigue consistently occurring at the end of a night of sleep deprivation. Effects of bright light or exercise exposure on subjective sleepiness appeared to be critically dependent on the timing of exposure.

Adult↗

Home blood glucose monitoring as an aid in diabetes management.

Home blood glucose monitoring, using Dextrostix and an Eyetone meter, has been utilized in several subcategories of patients with insulin-dependent diabetes mellitus. These include pregnant patients, anephric patients, patients undergoing weight reduction, patients with altered renal threshold for glucose reabsorption, and patients in whom diabetic regulation is difficult. Patients monitored home blood glucose continually (on a daily basis), intermittently, or only for particular problems or symptoms. Such monitoring can be practically accomplished in a manner acceptable to patients. Motivation, compliance with protocol, and an understanding of the objectives of the program are essential on the part of the patient. Home blood glucose monitoring, however, can provide an insight diabetes regulation that cannot be attained in any other way and can greatly facilitate regulation of diabetes. Such home blood glucose monitoring may increase the likelihood of achievement of a degree of control approximating euglycemia.

Adolescent↗

Prandial glycaemia after a carbohydrate-rich meal in type I diabetic patients: using the rapid acting insulin analogue [Lys(B28), Pro(B29)] human insulin.

The time-action profile of the insulin analogue insulin lispro ([Lys(B28), Pro(B29)] human insulin) with its rapid onset and short duration of action might be more suitable to limit hyperglycaemic excursions after a meal rich in rapidly absorbable carbohydrates in comparison to regular human insulin. A randomized, double-blind study was performed in 10 Type I diabetic patients with good metabolic control (HbA1c 7.0 +/- 0.5%). After a baseline period of 3 h (blood glucose clamped at 6.7 mmol l-1, i.v. insulin infusion of 0.2 mU kg-1 min-1 throughout the study), the patients ate a pizza, drank a cola and had a carbohydrate-rich dessert (total carbohydrate content 140 g). Immediately before the meal 15.4 +/- 3.5 U of either insulin preparation were injected subcutaneously. Blood glucose concentrations were monitored continuously thereafter. Following the injection of insulin lispro the area under the blood glucose curve after the meal was 78% of that of regular insulin (1.76 +/- 0.34 vs 2.26 +/- 0.68 mol l-1 *240 min-1; p < 0.01). Maximal blood glucose excursions were higher and were reached later after regular insulin as compared to insulin lispro (11.9 +/- 2.8 vs 9.9 +/- 1.4 mmol l-1; p < 0.05; 66 +/- 37 vs 41 +/- 7 min; p < 0.05). Maximal individual differences in the blood glucose excursions (regular human insulin minus insulin lispro) were 4.8 +/- 2.2 mmol l-1 (p < 0.0001 against zero) after 110 +/- 37 min. In Type 1 diabetic patients prandial blood glucose excursions after a carbohydrate rich meal were reduced after preprandial injection of insulin lispro in comparison to human regular insulin.

Adult↗