Pulmonary artery aneurysms due to Behçet's disease: MR imaging and digital subtraction angiography findings.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Between 1st January and 31st December 1987 126 consecutive patients underwent full myocardial revascularization using at least one internal mammary artery bypass grafting in Department of Cardiovascular Surgery of University of Freiburg. In 78 patients (75 males, 3 females) DSA was performed within 8 days after surgery to evaluate dynamics of IMA-graft. The age ranged from 38 to 67 years (mean 53.4 years). DSA study was performed through the brachial artery, contrast medium was injected with flow of 10 ml/sec. in counter current. It was only one series of angiograms necessary to visualise flow from subclavian artery, through IMA to coronary artery. Among 78 investigated patients in 61 (78%) the distal anastomosis appeared to be widely patent and flow through the IMA and anastomosed coronary artery was sufficient. Patency of one of the branches of IMA or stenosis of IMA graft contributed to inadequate flow in 12 patients (15.6%). In 5 (6.4%) operated patients the IMA graft was not patent. Counter current intraarterial DSA requires much smaller amount of contrast medium than classical angiography, moreover avoiding of aortic catheterization with all risks involved. The counter current intraatrial DSA is an excellent technics of estimation of the flow to grafted coronary arteries. The method is easy to perform, repetitive and carry very small risk for the patient. Early postoperative evaluation of IMA-graft patency is essential for estimation of effectiveness of myocardial revascularisation and prognosis for the patient.
The exact analysis of an anomalous pulmonary venous return in patients with congenital shunt disease can lead to some difficulties when using the standard catheterization techniques. A left-sided anomalous pulmonary vein was suspected in a case with atrial and ventricular septal defects, but could not be evaluated during the catheterization procedure. The pathological vessel could be demonstrated exactly only by venous digital subtraction angiography. Thus, the digital subtraction angiography showed a diagnostic benefit in this complex shunt disease and should be considered in further problematic cases.
As part of an ongoing study comparing digital subtraction angiography (DSA) with conventional film-screen angiography, 150 patients were examined with arterial contrast material injections and digital filming techniques alone or combined with conventional angiography. Of 247 injections, the DSA study was good or excellent in 236, approaching the quality of conventional angiography for visualization of vessels greater than 1 mm in size. Advantages included improved vascular detail in selected areas such as the skull base, visualization of minimal contrast concentration in diseased vessels or postoperatively, and imaging of vessels distal to stenoses without the hazards of selective catheterization. DSA permitted rapid positioning under fluoroscopic control, instantaneous viewing of subtracted images, and reduced technologist time and film costs. Contrast material volume was reduced by 40 to 60%, allowing multiple studies in one sitting and study of patients with renal compromise.
Explore the source record for details and available documents.
The diagnostic potentialities of digital subtraction angiography (DSA) in diseases of the pelvic arteries and lower limbs were studied. Intravenous (iv) and intraarterial (ia) DSA were performed in 613 patients, among them were patients with obliterating atherosclerosis and endarteritis, thromboembolism, aneurysms and arteriovenous fistulas. Iv DSA provided good information for the solution of therapeutic and tactical problems in pelvic, femoral and popliteal arterial lesions but in 16% of the cases it gave no opportunity to assess the status of the crural arteries. Ia DSA was shown to be no inferior to routine arteriography in the visualization of the lower limb arteries. This method is economical, well tolerated by patients, permits the intensification of examination of patients with acute and chronic arterial pathology. It can be employed under outpatient conditions and in the early postoperative period.
The use of duplex ultrasound with colour flow mapping is compared with that of intravenous digital subtraction angiography (IVDSA) in the investigation of carotid and vertebral artery disease. Ninety-nine carotid and vertebral arteries were examined independently by IVDSA and ultrasound for location and degree of disease in 30 men (mean age 58) and 20 women (mean age 53). For purposes of comparison the carotid tree was divided into six segments. In 46% of cases no disease was detected by either modality. In 36% of cases where disease was found, ultrasound found mild disease in arteries reported as normal by IVDSA. Both modalities detected the six cases of total occlusion found in the study. IVDSA underestimated five cases of major disease found by ultrasound at the bifurcation or in the bulb. Overall agreement in grading vessel segments was good, with 74.5% in complete agreement and 90.3% grading stenoses to within +/- 25% of the other modality. There was good qualitative agreement in the findings for vertebral arteries. In four patients conventional arteriography was also available for comparison.
PURPOSE: To evaluate one-molar Gadobutrol solution as contrast media for intra-arterial digital subtraction angiography (DSA). MATERIALS AND METHODS: In 10 patients (7 males, 3 females; mean age 68 years) with contraindications for the use of iodinated contrast media (n = 8 renal insufficiency, n = 2 previous allergic reaction), Gadobutrol solution (1 mol/l) was used as contrast media for DSA. Six diagnostic angiograms and four DSAs for percutaneous transluminal angioplasty (PTA) were performed. RESULTS: In all cases, Gadobutrol yielded sufficient contrast for diagnostic DSA. Because of dose limitations (maximum 0.3 ml/kg body weight), small amounts of iodinated contrast media were administered to complete the angiographic procedure (mean 15 ml) in two patients. Allergic reactions were not recorded in any patient. In patients with pre-existing renal insufficiency, mean serum creatinine level was not statistically significant different from the initial level (mean 2.88 mg/dl before and 2.83 mg/dl after DSA). Selective injection of Gadobutrol resulted in temporary discomfort. CONCLUSION: One molar Gadobutrol is an alternate contrast media for DSA in patients with contraindications for iodinated contrast media. Current dose limitations require selective injections.
The increasing use of small animals in basic research has spurred interest in new imaging methodologies. Digital subtraction angiography (DSA) offers a particularly appealing approach to functional imaging in the small animal. This study examines the optimal x-ray, molybdenum (Mo) or tungsten (W) target sources, and technique to produce the highest quality small animal functional subtraction angiograms in terms of contrast and signal-difference-to-noise ratio squared (SdNR2). Two limiting conditions were considered-normalization with respect to dose and normalization against tube loading. Image contrast and SdNR2 were simulated using an established x-ray model. DSA images of live rats were taken at two representative tube potentials for the W and Mo sources. Results show that for small animal DSA, the Mo source provides better contrast. However, with digital detectors, SdNR2 is the more relevant figure of merit. The W source operated at kVps >60 achieved a higher SdNR2. The highest SdNR2 was obtained at voltages above 90 kVp. However, operation at the higher potential results in significantly greater dose and tube load and reduced contrast quantization. A reasonable tradeoff can be achieved at tube potentials at the beginning of the performance plateau, around 70 kVp, where the relative gain in SdNR2 is the greatest.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
To elucidate the three-dimensional structure of the anterior communicating artery complex, we performed three-dimensional digital subtraction angiography in anterior communicating (Acom) aneurysm cases. Eighteen patients (six male and 12 female) with Acom aneurysms were studied. The total number of aneurysms was 18, of which three were unruptured and 15 were ruptured. Aneurysmal sizes and angles between the parent artery and each of the two daughter arteries were measured. Two types were defined, based on the daughter arteries. When the sizes of the two daughter arteries were the same, they were defined as AA' type, and when different, they were defined as AB type. Furthermore, aneurysms were classified into two types based on neck location. Thus, when the neck was located on the extension of the midline of the parent artery, it was defined as classical neck type, and when it was not, it was defined as deviating neck type. There were 11 cases of AA' type and seven of AB type. In AA' type all cases were of the classical neck type, and in AB type three cases were of the classical neck type and three were of the deviating neck type. In the deviating neck type, the necks were deviated to the smaller daughter arteries in all cases.
PURPOSE: Patients with renal insufficiency or other contraindications to iodine-based contrast agents present a significant management dilemma when angiography or interventional procedures are required. We describe the use of gadolinium as an alternative contrast agent for intravenous digital subtraction angiography (IV-DSA) and interventional procedures of the upper extremity veins. METHODS: Sixteen patients with symptoms of with moderate renal insufficiency underwent digital subtraction angiography for upper extremity and subclavian venography. Angiographic studies were obtained using gadolinium as a contrast agent. In six patients we used stents. RESULTS: Diagnostic images were obtained in all cases. No patient suffered a complication related to the use of gadolinium, and no patient demonstrated worsened renal function after the procedure. CONCLUSION: In the setting of a contraindication to iodine-based contrast agents, gadolinium represents an important alternative contrast material that allows for the visualization of and interventional procedures in the upper extremity veins.
BACKGROUND AND PURPOSE: Although dynamic contrast-enhanced MR angiography studies for arteriovenous malformations (AVFs) and brain tumors have shown promising results, no formal attempt has yet been made to similarly evaluate dural AVFs. To assess the practical applicability of 2D thick-section contrast enhanced MR digital subtraction angiography (MRDSA) for the diagnosis and management of dural AVFs, MRDSA and intra-arterial digital subtraction angiography (IADSA) were comparatively evaluated. METHODS: We performed 80 consecutive MRDSA studies for 25 dural AVFs, including 11 cavenous sinuses, 9 sigmoid sinuses, 2 tentorial sinuses, one anterior condylar vein, one craniocervical junction, and one spine. MR images were continuously obtained following the initiation of a bolus injection of gadrinium chelates and subtraction images were constructed. We thereafter evaluated the imaging quality and hemodynamic information from all 46 MRDSA images performed in parallel with IADSA in either perioperative or follow-up studies. RESULTS: Most MRDSA images detected early venous filling, sinus occlusion, leptomeningeal venous drainage, and varices. It was difficult, however, to identify the feeding arteries because of both the partial volume effect and a low spatial resolution. Most important, MRDSA accurately detected aggressive lesions with leptomeningeal venous drainage and varices. CONCLUSION: Our MRDSA technique was found to have limited value for depicting all the anatomic details of dural AVFs, though it was able to identify important hemodynamic abnormalities related to the risk of hemorrhaging. MRDSA is therefore useful as a less invasive, dynamic angiographic tool, not only for perioperative studies but also for follow-up studies.
This case report illustrates the value of intravenous digital subtraction angiography (DSA) in cases of penetrating neck injury. The debate continues between a policy of mandatory exploration of all penetrating neck wounds versus one of selective exploration with observation of the remainder. The argument for the former policy is that vascular trauma can occur without clinical signs. Whichever policy is followed a DSA provides invaluable information in strengthening the decision either not to operate or if operating which operation to perform and which approach to use. DSA is a quick, simple and safe investigation that can be carried out at any time of day or night.
A 14-inch image intensifier designed for digital radiography has made feasible adjunctive evaluation of the renal parenchyma and collecting structures following intravenous digital subtraction angiography (DSA). Initial experiments with rabbits showed digital nephrography to be superior to film-based nephrotomography in terms of renal conspicuity and imaging flexibility. Preliminary experience with 30 patients undergoing DSA reaffirms the suitability of this method for the evaluation of renal anatomy and function. Only about half the amount of contrast material needed for conventional excretory urography is required.
A new automatic computer program, to remove misregistration artifacts secondary to motions such as rotation, contraction and relaxation of the body, has been developed. This program is called automatic reregistration and consists of determination of distortion vectors of corresponding segments of the mask and live images by detection of the peak value of two-dimensional cross correlation, followed by obtaining distortion vectors of other pixels through interpolation. Shift of the coordinate of the distorted live image is subtracted. Clinical evaluation of this new program, in comparison with already developed remasking and manual reregistration, have proved that some misregistration artifacts, uncorrectable by the latter two methods, have been removed to some extent. The new program has proven to be clinically useful.