PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Assay development”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Development of immunoturbidimetric assays for fourteen human serum proteins on the Hitachi 912.

Many laboratories rely on dedicated nephelometers or turbidimeters and commercial reagent kits for the evaluation of serum proteins. However, with growing emphasis on cost containment, laboratories are forced to seek additional operational efficiencies by capitalizing on the use of existing analyzers whenever possible. In the present paper we describe the development of immunoturbidimetric assays for routine analysis of 14 human serum proteins (alpha1-antitrypsin, alpha2-macroglobulin, albumin, apolipoproteins Al and B, complement components 3 and 4, haptoglobin, immunoglobulins A, G, and M, orosomucoid, prealbumin, and transferrin) on the Hitachi 912, a general chemistry analyzer. With this system, we obtained excellent precision at levels corresponding to low, normal, and high physiologic concentrations of each protein (within-run imprecision CVs < or = 3.4%, total imprecision CVs < or = 4.1%). Linearity for each method was within 5% of the expected value throughout the calibration range, and method comparisons with either the Roche turbidimetric or Dade Behring nephelometric assays were in good agreement (r >0.97). We observed no significant interference from bilirubin (up to 718 micromol/l), hemoglobin (up to 8 g/l), triglyceride (up to 14.7 mmol/l) or rheumatoid factor (up to 4,140 IU/ml). Calibration for the 14 protein assays was stable for at least 7 days and onboard refrigerated reagents were stable for at least 3 months. The instrument's automated sample re-run feature minimized sample handling and helped to conserve specimens. In conclusion, the newly developed assays on the Hitachi 912 offer high throughput (>250 tests per hour) without the associated cost of a dedicated instrument for protein assays.

Blood Proteins↗

Development of broad-range 16S rDNA PCR for use in the routine diagnostic clinical microbiology service.

The aim of the present study was to develop a broad-range PCR based on bacterial 16S rDNA for use in the routine diagnostic clinical microbiology service. The optimization and validation of the assay for use on clinical specimens from normally sterile sites is described, and preliminary results are reported on the use of the assay in the clinical diagnosis of bacterial infection in 382 paediatric specimens over a 2-year period. These results are compared to those obtained by standard culture techniques and show increased diagnosis of bacterial infection when both culture and PCR are used together; 16S rDNA PCR provided the sole evidence of pathogenic infection in 71 cases. Key stages in the assay development and potential pitfalls of the technique are highlighted and the improvement the assay offers in the diagnosis of infection in the paediatric setting is discussed.

Bacteria↗

Hapten synthesis and development of polyclonal antibody-based multi-sulfonamide immunoassays.

This paper reports the synthesis of five sulfonamide derivatives, the production of broad-specificity polyclonal antibodies for immunoassay of sulfonamides, and the analysis of milk samples by developed assay. The three-step synthesis procedure reported in most of the literature was adopted and modified in this study. In the procedure, the purification of the intermediate was avoided and the time of synthesis was shortened from >20 to 6-9 h with improved yields. This method is generally applicable to the synthesis of haptens containing the common structure of sulfonamides. Three haptens were coupled to keyhole limpet hemocyanin, and polyclonal antibodies were obtained from rabbits immunized with these conjugates. Using the antibodies obtained, from one of these was developed an enzyme-linked immunosorbent assay (ELISA) based on the competition between free sulfonamides and the hapten-horseradish peroxidase (HRP) conjugates. The hapten-HRP conjugate giving the best competitive results and 11 structurally different sulfonamides showed 50% inhibition at concentrations of <100 ng mL(-1). After removal of the protein with acetone, milk samples were analyzed by ELISA directly; a matrix effect could be avoided when a 1:20 dilution with phosphate-buffered saline was used, and 104-131% recoveries of spiked samples were obtained. The developed immunoassay is suitable to determine sulfisozole, sulfathiazole, sulfameter, sulfamethoxypyridazine, sulfapyridine, and sulfamethizole below the maximum residue limit in milk (100 ng mL(-1) of total sulfonamides) rapidly and reliably.

Animals↗

New high-performance liquid chromatographic method for the determination of alprazolam and its metabolites in serum: instability of 4-hydroxyalprazolam.

A high-performance liquid chromatographic method was developed for the determination of alprazolam (ALP) and its active metabolites, alpha-hydroxyalprazolam (AOH) and 4-hydroxyalprazolam (4OH) in human serum. During assay development, the instability of 4OH was revealed. Factors affecting stability of 4OH were then investigated. In this report, the assay methodology for the determination of ALP and AOH, the instability of 4OH, subsequent interference of 4OH breakdown products with AOH quantification, and factors affecting 4OH stability are described. The clinical significance of our findings are reported.

Alprazolam↗

Bioassay detects soluble MAdCAM-1 in body fluids.

Mucosal addressin cell adhesion molecule (MAdCAM-1) is a key player in mediating the infiltration of leucocytes into chronically inflamed tissues. Five anti-MAdCAM-1 monoclonal antibodies (mAb), designated 17F5, 201F7, 314G8, 377D10 and 355G8, were generated by fusion of P3 x 63Ag8.653 myeloma cells with spleen cells from BALB/c mice immunized with recombinant human MAdCAM-1-Fc. The latter four mAb recognize the ligand-binding first Ig domain, and block T -cell adhesion to MAdCAM-1. The non-blocking mAb 17F5 recognizes the mucin domain. Extensive analysis of a large panel of paraffin-embedded human tissues revealed that the 314G8 mAb detected MAdCAM-1 on venules in the spleen and small intestine. MAdCAM-1 was strongly expressed in the synovium of osteoarthritis patients, predominantly on the endothelial lining of blood vessels, but also within the vessel lumen. An ELISA, based on mAb 377D10 and 355G8, was developed to determine whether soluble MAdCAM-1 was present in body fluids, and to measure the levels present. The assay detected soluble MAdCAM-1 in the serum and urine of healthy donors, at levels similar to those of soluble forms of the related CAM, ICAM-1 and VCAM-1. The anti-MAdCAM-1 antibodies and assay developed here may be useful therapeutically in the treatment of inflammation in humans. Similarly, they may be useful diagnostically to monitor the presence and levels of MAdCAM-1.

Animals↗

Rapid and simple detection of Ebola virus by reverse transcription-loop-mediated isothermal amplification.

Ebola virus (EBOV) causes severe hemorrhagic fever in humans and nonhuman primates with high mortality rates. Rapid identification of the virus is required to prevent spread of the infection. In this study, we developed and evaluated a one-step simple reverse transcription-loop mediated isothermal amplification (RT-LAMP) assay for the rapid detection of Zaire ebolavirus (ZEBOV), the most virulent species of EBOV, targeting the trailer region of the viral genome. The assay could detect 20 copies of the artificial ZEBOV RNA in 26 min with a real time-monitoring detection, and also detect 10(-3) FFU of the cell-culture propagated viruses. The reaction time needed to detect 10(4) FFU of ZEBOV was only 20 min. In addition, the assay was highly specific for ZEBOV. The RT-LAMP assay developed in this study is rapid, simple, highly specific, and sensitive for the detection of ZEBOV, and so may be an effective diagnostic tool. Furthermore, as this technique does not require sophisticated instrumentation, it seems very suitable for diagnosis in the field or laboratories in Ebola outbreak areas such as Central Africa.

Animals↗

Proteinchip(R) surface enhanced laser desorption/ionization (SELDI) mass spectrometry: a novel protein biochip technology for detection of prostate cancer biomarkers in complex protein mixtures.

Improving early detection, diagnosis, treatment monitoring and prognosis of cancer will require rapid and high throughput detection, identification, and measurement of multiple biomarkers. In this study, we demonstrate the versatility of the innovative SELDI ProteinChip(R) MS technology for the rapid, reproducible and simultaneous identification of four well-characterized prostate cancer-associated (PCA) biomarkers, prostate specific antigen (free and complexed forms), prostate specific peptide, prostate acid phophatase and prostate specific membrane antigen in cell lysates, serum and seminal plasma. Proteins corresponding to the mass of these biomarkers could readily be captured and detected using either chemically defined or antibody coated ProteinChip(R) arrays. Several (yet to be identified) proteins were found upregulated in cell lysates of pure populations of PCA cells procured by laser capture microdissection (LCM) when compared with mass spectra of normal cell lysates. Coupling LCM with SELDI provides tremendous opportunities to discover and identify the signature proteins associated with each stage of tumor development. Collectively, these observations demonstrate the potential of SELDI for the discovery and simultaneous detection of and clinical assay development for PCA biomarkers in complex biological mixtures.

Journal Article↗

Real-time PCR improves detection of Trichomonas vaginalis infection compared with culture using self-collected vaginal swabs.

OBJECTIVE: To compare a real-time polymerase chain reaction (PCR) assay with broth culture for the detection of Trichomonas vaginalis using self-collected vaginal swabs. METHODS: Self-collected vaginal swabs were obtained from adolescent and young adult African-American women participating in HIV-1 prevention programs. T. vaginalis culture was performed using the InPouch TV System. Samples for the real-time PCR assay were collected using the BDProbeTec ET Culturette Direct Dry Swab system and tested in a laboratory-developed assay which targeted a repeated sequence of the genome. Discrepant samples that were culture negative and positive in the real-time PCR assay were tested in a confirmatory PCR which targeted a different region of the T. vaginalis genome, the18S ribosomal DNA gene. RESULTS: Of the 524 specimens tested by both culture and real-time PCR, 36 were culture positive and 54 were positive in the real-time PCR assay; 16 of the 18 discrepant specimens were also positive in the confirmatory PCR assay. Using a modified gold standard of positive by culture or positive in both PCR assays, the sensitivity of the real-time PCR assay was 100% and the specificity was 99.6%, whereas culture had a sensitivity of 69.2% and a specificity of 100%. CONCLUSIONS: The real-time PCR assay was sensitive and specific for the detection of T. vaginalis DNA from self-collected vaginal swab specimens. The ability to use the BDProbeTec dry swab system for the real-time PCR testing allowed for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and T. vaginalis from a single specimen.

Adolescent↗

Intra-individual variation in plasma and erythrocyte cholinesterase activities and the monitoring of uptake of organo-phosphate pesticides.

The measurement of plasma and erythrocyte cholinesterase activities is used to monitor absorption of anti-cholinesterase organo-phosphorus compounds. A fall in an individual's enzyme activity signifies excessive exposure if it is clearly greater than the normal intra-individual variation found in unexposed subjects. The extent of normal variation in enzyme activity as measured is dependent on both the true intra-individual biological variation and the precision of the method used. This report defines normal variation in plasma and erythrocyte cholinesterase activity using the assay developed and used routinely in our laboratory. We have also defined the relation between the precision of the assay used by a laboratory and the sensitivity with which a significant depression in successive enzyme measurements can be detected. This allows occupational physicians, who use cholinesterase measurements to monitor organo-phosphate exposure, to establish percentage depressions from their method precision data that may possibly indicate organo-phosphate uptake between successive enzyme measurements. We have calculated that, with our analytical precision, percentage drops between two successive measurements that are greater than 15 and 7.5 per cent for the plasma and erythrocyte enzymes respectively suggest significant organo-phosphorus absorption in pesticide workers.

Cholinesterase Inhibitors↗

Measurement of serum bone-specific alkaline phosphatase activity in cynomolgus macaques.

Serum levels of bone-specific alkaline phosphatase activity (B-ALP) in cynomolgus monkeys were evaluated as an index of elevated bone turnover following ovariectomy. The enzyme immunoassay 96-well microtiter plate B-ALP assay, developed by Metra Biosystems (Mountain View, CA) for human use, was employed and compared with a standard automated assay measuring total serum levels of alkaline phosphatase activity (T-ALP). The B-ALP assay was first validated for use in these monkeys. Ovariectomy led to increased bone turnover as indicated by approximately 2-fold higher activity in both assays and this elevation was inhibited by daily estradiol administration. Although both assays provided generally similar results, several monkeys were observed to have greatly elevated values of T-ALP but not B-ALP. This discrepancy is believed to result from high levels of the liver isoform of alkaline phosphatase in monkeys with hepatic dysfunction, which are not detected by the B-ALP assay.

Alkaline Phosphatase↗

Comparative prevalence of the mercury resistance gene merA in human feces, food, and environmental water from Japan, Vietnam, and Ghana.

In this study, we investigated the prevalence and abundance of the mercury resistance gene merA in human feces, retail chicken meat, and environmental water samples collected from Japan, Vietnam, and Ghana. A real-time PCR assay developed in this study demonstrated high specificity toward merA sequences from more than 12 bacterial species. Using this assay, merA was detected in 6.8% of human fecal samples in Japan (n&#x2009;=&#x2009;29), in contrast to significantly higher rates observed in Vietnam (70.2%, n&#x2009;=&#x2009;47) and Ghana (97.4%, n&#x2009;=&#x2009;39). Similar geographic trends were evident in the chicken meat samples: 18.5% in Japan (n&#x2009;=&#x2009;27), 66% in Vietnam (n&#x2009;=&#x2009;91), and 90% in Ghana (n&#x2009;=&#x2009;10). Environmental water samples showed a consistently high merA detection rate across all countries (75-100%, n&#x2009;=&#x2009;21), with substantially higher gene copy numbers in Vietnam and Ghana than in Japan. merA was detected in some water samples, even when total mercury concentrations were below the detection limit, indicating that molecular detection may offer greater sensitivity than traditional physicochemical methods. Mercury-resistant bacteria were successfully isolated and cultured, and Citrobacter freundii was identified as the representative strain. Genomic analysis revealed that merA was located on an IncFIB plasmid, flanked by insertion sequences, suggesting its potential for horizontal gene transfer. These findings highlight merA as a promising biomarker for environmental mercury exposure and support the utility of fecal merA analysis as a proxy for assessing mercury-related public health risks.

Humans↗

Detection of low levels of urinary mutagen excretion by chemotherapy workers which was not related to occupational drug exposures.

Urine specimens from a total of 26 subjects who were either nurses, pharmacists, or pharmacy technicians engaged in the preparation, handling, or administration of cancer chemotherapeutic agents were analyzed for the presence of mutagenic substances. Assays were performed using bacterial strains TA98 and TA100 in the Salmonella/mammalian microsomal mutagenicity assay developed by Ames et al. (Mutat. Res., 31: 347-364, 1975). Findings were compared with results from similar assays of urine specimens for 38 hospital personnel not exposed to cancer chemotherapeutic agents. There was no evidence of an association between occupational exposure to chemotherapy drugs and the presence of mutagenic substances that could be detected by this assay procedure in either specimens of filter-sterilized urine or extracts of urine concentrated with XAD-2 resins. An association was observed, however, between smoking and increased urinary excretion of mutagens. None of the observed associations was changed substantially by statistical adjustment for the occupational category of the subject (nurse or pharmacist), hospital of employment, or values of concurrent solvent controls for the mutagenesis assays. Associations with occupational exposures were not changed by controlling for smoking history. In addition to the large increases for smokers, testing of extracts of urine from nonsmokers with bacterial strain TA98 yielded mutagenicity values that averaged about 50% higher than values for solvent controls. Similar small increases were observed in previous published reports of human urine mutagenicity assays using tester strains TA1538 and TA98. We found little evidence to suggest that the small increases observed for nonsmokers were associated with technical factors such as the presence in the extracts of histidine or other substances promoting bacterial growth or contamination of the specimens during collection or extraction procedures. Since it appears that technical factors can be excluded, we believe that the increases were associated with urinary excretion of low levels of mutagen by a high proportion of subjects tested. The lack of an association of mutagenicity with occupational exposure to chemotherapeutic drugs may have been due to protective measures at the hospitals surveyed and suggests that, with appropriate procedures, these agents can be administered in a manner such that human exposure cannot be detected using this approach.(ABSTRACT TRUNCATED AT 400 WORDS)

Antibiotics, Antineoplastic↗

Early hemopoietic progenitors in the peripheral blood of patients with severe aplastic anemia (SAA) after treatment with antilymphocyte globulin (ALG), cyclosporin-A and G-CSF.

BACKGROUND AND OBJECTIVE: We previously reported that patients with acquired severe aplastic anemia (SAA) treated with antilymphocyte globulin (ALG), 6-methylprednisolone, cyclosporin A (CyA) and granulocyte colony-stimulating factor (G-CSF) can mobilize peripheral blood hemopoietic progenitors (PBHP). The aim of the present study was to assess phenotypic and functional properties of these PBHP. METHODS: We studied seven patients who underwent 43 leukophereses (median 5) between day +30 and +80 following ALG, while in treatment with CyA and G-CSF. Mobilized peripheral blood hemopoietic progenitors were analyzed using surface markers, conventional assays for clonogenic cells (CFU-GM, BFU-E, CFU-GEMM) as well as the recently developed assay for long-term culture initiating cells (LTC-ICs). RESULTS: The proportion of CD34+ cells ranged between 0% and 5.4% (median 0.3%), CD34+DR between 0% and 3.5% (median 0.1%) and CD8+ cells between 3.3% and 56% (median 31%). When light density mononuclear cells (MNC) were plated in vitro, we could grow colony-forming units-granulo-macrophage (CFU-GM) (range 0-45/10(5) MNC; normal controls 21-200/10(5) MNC), burst-forming units-erythroid (BFU-E) (range 0-5/10(5) MNC; normal controls 0-6/10(5) MNC), multipotent colonies (CFU-GEMM) (range 0-3/10(5) MNC; normal controls 0-6/10(5) MNC) and high proliferative potential colony-forming cells (HPP-CFC) (range 0-3.4/10(5) MNC). We studied long-term culture-initiating cells (LTC-ICs) in 18 leukophereses from 4 patients; in 7/18 samples LTC-ICs were grown at low frequency (range 0.4-2/10(6) MNC) (normal controls 5-130/10(6) MNC), and in one patient in the absence of CFU-GM growth. The total yield of LTC-ICs in two patients was 7.64 and 10.5 x 10(2)/kg of body weight. INTERPRETATION AND CONCLUSIONS: This study suggests that cells with the phenotype and in vitro function of early hemopoietic progenitors are found, though in small numbers, in the peripheral blood of patients with SAA after treatment with immunosuppressants and prolonged G-CSF administration. Whether G-CSF-mobilized progenitors contribute to hemopoietic recovery in these patients remains to be determined.

Adolescent↗

Review: IgA anaphylactic transfusion reactions. Part I. Laboratory diagnosis, incidence, and supply of IgA-deficient products.

Despite yielding a definitive diagnosis in fewer than 20 percent of anaphylactic transfusion reactions, investigation for IgA deficiency and the presence of presumably pathogenic IgG anti-IgA is useful in patient management. Individuals with demonstrated anti-IgA are thereafter committed to receiving IgA-depleted cellular products or IgA-deficient plasma and derivatives to prevent recurrent severe reactions. Unfortunately, in populations of IgA-deficient individuals screened for anti-IgA, the predictive value of the test in the absence of a prior reaction is quite low. Anti-IgA testing is complex and limited to a few reference laboratories, many of which still employ a labor-intensive hemagglutination assay developed in the late 1960s. Timely decisions regarding further transfusion management of patients experiencing anaphylaxis often rely upon more rapidly obtained assays of the IgA concentration as an indicator of the likelihood of subsequent demonstration of anti-IgA. The scarcity of IgA-deficient banked plasma products and dedicated plateletpheresis donors has led to the development of American Rare Donor Program policies designed to appropriately allocate these precious resources. The test methods used to establish the diagnosis of IgA deficiency and identify the approximately one third of these individuals with anti-IgA are discussed, along with the incidence of abnormal tests in various populations. Also presented are testing recommendations for the identification of an IgA-mediated mechanism for transfusion-associated anaphylaxis and qualification of patients to receive rare IgA-deficient plasma-containing products.

Anaphylaxis↗

Development of the antibody response in acute HIV-1 infection.

BACKGROUND: Cytotoxic T lymphocytes have been shown to reduce viraemia during acute HIV-1 infection; however the role of neutralizing antibodies in this process is unclear. One confounding factor may be artefacts introduced by viral culture. OBJECTIVE: To assess the development of autologous neutralizing and non-neutralizing antibodies following acute HIV-1 infection using recombinant viruses with envelopes amplified directly from patient peripheral blood mononuclear cells, thereby avoiding in vitro selection. METHODS: Disease progression in four homosexual men was monitored from acute infection for up to 2.5 years, in the absence of antiretroviral therapy. Antibodies to viral envelope protein were quantified by enzyme-linked immunosorbent assay. Development of neutralizing antibodies was monitored using a quantitative infectivity reduction assay, sequential serum, recombinant viruses and target cells with defined receptor expression. RESULTS: The time to development of neutralizing antibodies after onset of symptoms was 3, 5, 7 and 16 months in the four patients. There was no correlation between development of neutralizing antibodies and the resolution of viraemia in any of the patients. However, antibodies to the envelope were detectable as early as 2 weeks after onset of symptoms. CONCLUSIONS: Neutralizing antibodies do not contribute to the control of viraemia in acute HIV-1 infection. However, antibodies to the envelope could be detected at the time of reduction in plasma viraemia and so other effector functions of antibodies may play a role in viral clearance.

Acute Disease↗

Combined measurement of ferritin, soluble transferrin receptor, retinol binding protein, and C-reactive protein by an inexpensive, sensitive, and simple sandwich enzyme-linked immunosorbent assay technique.

The measurement of vitamin A (VA) and iron status is very important in the assessment of nutritional deficiencies. The objective of this research was to develop a sandwich ELISA technique for the simultaneous measurement of ferritin, soluble transferrin receptor, retinol binding protein, and C-reactive protein (CRP) as indicators for VA and iron status. The inclusion of CRP as marker of infection allows for more accurate interpretation of VA and iron status. This is accomplished in a 30-microL serum or plasma sample using an ELISA with different capture and detection antibodies and different dilutions of the sample. Commercially available clinical serum controls were used for calibration purposes. The developed assays were compared to commercially available traditional tests. Regression coefficients comparing both assays were better than 0.84 (P < 0.001). Using a limited sample set, the sandwich ELISA assay produced very similar specificity and sensitivity compared to traditional methods when common cutoff values were applied. Intra- and interassay variability was between 5 and 14% for all tests. The cost of the materials for all 5 measurements decreases to less than $1/sample if a large number of samples is analyzed. Due to the low cost, high throughput, and comparability to traditional tests, this procedure has several advantages for assessing VA and iron status in population surveys.

C-Reactive Protein↗

Evaluation of a prototype HCV NS5b assay for typing strains of hepatitis C virus isolated from Tunisian haemodialysis patients.

Hepatitis C virus (HCV) strains isolated from 68 haemodialysis Tunisian patients exhibiting chronic infection were genotyped targeting the NS5b region of the HCV genome using a prototype assay developed by Bayer HealthCare-Diagnostics (TRUGENE NS5b HCV). The overall results were compared to those obtained with another assay of the same company based on sequencing of the 5' non-coding region (TRUGENE HCV 5'NC genotyping kit). All strains could be typed by the 5'NC typing kit, but only 62 (91; 2%) by the NS5b prototype assay. All the 62 strains typed by both methods exhibited the same pattern at the type level: 57 were type 1, 3 were type 2, and 2 were type 4. At the subtype level, eight strains that gave undetermined results by the 5'NC kit were successfully typed by the NS5b kit; eight additional strains exhibited discrepant results. The overall agreement between the two assays was 74.2% at the subtype level. In conclusion, the NS5b region appears to be much more accurate than the 5'NC region to subtype HCV strains, especially in those isolated from patients attending haemodialysis centres where the subtype distribution suggests frequent nosocomial transmissions.

5' Untranslated Regions↗

Evaluation of the performance of LNA and MGB probes in 5'-nuclease PCR assays.

The aim of this study was to evaluate the use of Locked Nucleic Acids (LNA) probes in 5'-nuclease PCR, by comparison with Minor Groove Binder (MGB) probes routinely practiced in laboratories on ABI Prism 7700. The comparison was made using a collection of Staphylococcus aureus strains that have already been characterized by MGB 5'-nuclease PCR assays in a previous study [Mol Cell Probes, submitted for publication]. The sensitivity and specificity of 5'-nuclease PCR assays targeting the Staphylococcal enterotoxin genes sea to see were compared and showed that the LNA and MGB methods were equivalent. In conclusion, the LNA 5'-nuclease PCR assays developed in this work provide a specific and sensitive alternative to the well-established MGB 5'-nuclease PCR assays used for the rapid detection of bacterial pathogens genes on ABI Prism 7700.

DNA Primers↗