Biocompatibility of polyvinylalcohol gel as a vitreous substitute.

Polyvinylalcohol (PVA) hydrogel cross-linked by gamma irradiation was assessed as a possible vitreous substitute. From a series of experiments, rise of intraocular pressure and inflammatory changes in the vitreous cavity after operation were observed in some cases. Crab-eating macaques were used for this experiment. PVA gels were injected into vitreous cavity after vitrectomy and followed clinically by opthalmoscopy, tonometry, fundus photography, electroretinogram (ERG), chemotaxis, and flare cell meter. Histopathologic examination by light and electron microscopy was performed after 3 months. As a result, there were no significant changes in ophthalmoscopic findings. No abnormal rising of intraocular pressure (IOP) was recognized. ERG did not show meaningful amplitude weakness. From the photon counting of flare cell meter, significant break of blood-aqueous barrier and blood-retinal barrier was not observed. Histopathologic examination revealed that all layers of the retina were intact and no loss of tissue was evident. However, in PVA gel-injected eyes, some vacuolations of the inner retina were found in some specimens. To conclude, PVA gel was well tolerated in these experiments. The gel with a network similar to the vitreous body showed the best biocompatibility, though it is necessary to investigate the biocompatibility for the long-term. PVA gel is a good candidate for a vitreous substitute.

Animals↗

Biocompatibility study based on differential sequestration kinetics of CD14+CD16+ blood monocyte subsets with different dialyzers.

The immune defect in hemodialysis (HD) patients is associated with a monocyte dysfunction, including an increase in the production of proinflammatory cytokines. Blood membrane contact leads to an increase in cellular activation and sequestration into the capillary bed of the lung. The influence of the sequestration on the number of mature monocytes was studied by analyzing the fate of monocytes, particularly, the CD14+CD16+ subpopulation, during HD treatment. In thirty stable HD patients, the distinct cell populations were determined by differential blood counts and flow cytometry. Patients with diabetes or systemic vasculitis, those showing evidence of infectious complications or malignancy, or those taking immunosuppressive medications were excluded from the study. Cells from this study population were analyzed before the start, 30 min thereafter, and at the end of HD treatment, each time using a different dialyzer: hemophan, methylmethacrylate (PMMA), triacetate membrane, cuprophane/vitamin E, acrylonitrile, and sodium methallylsulfonate polymer (AN69). The CD14+CD16+ subset decreased at 30 min and remained suppressed for the course of dialysis. To examine whether currently used biocompatible membranes differ in their effect on the sequestration of monocyte subpopulations, temporal monocytic changes were comparatively analyzed during HD with a different dialyzer. The drop in the first 30 min until the end of HD treatment was significant (p<0.05), very uniform, and sharp in all patients, and was independent upon membrane type. The CD14+CD16+ monocyte subpopulation showed increased and longer margination from the blood circulation during HD. Given the fact that CD14+CD16+ monocytes represent a sensitive marker for inflammation or cellular activation, the depletion of these cells may offer an easily accessible parameter that is more sensitive than complement activation for biocompatibility studies on forthcoming, improved dialyzer membranes.

Aged↗

Tissue biocompatibility of a new caprolactone-coated self-reinforced self-expandable poly-L-lactic acid bioabsorbable urethral stent.

BACKGROUND AND PURPOSE: The bioabsorption time as well as other properties of bioabsorbable polymers can be affected by the choice of the basic molecule, by the degree of its polymerization, and by the coating material used in the device. The aim of our present study was to evaluate the biocompatibility of a new caprolactone copolymer-coated, self-reinforced poly-L-lactic acid (SR-PLLA) urethral stent by means of a rabbit muscle implantation test. This new material has previously been tested for cytotoxicity using the thymidine incorporation method (DNA synthesis inhibition test), no toxicity being evidenced. MATERIALS AND METHODS: Fifteen male rabbits were used as experimental animals. Rods made from pure lactic acid, pure caprolactone copolymer, and caprolactone-coated lactic acid were placed on both sides of the dorsal muscles, eight implants per rabbit. Rods made from latex and silicone were used as positive and negative controls, respectively. The animals were sacrificed after 1 week, 1 month, or 6 months. Tissue reactions around the implants were analyzed and scored semiquantitatively. RESULTS: Acute tissue reactions attributable to operative trauma were seen in all specimens at 1 week. After 6 months, chronic inflammatory changes and foreign-body reactions were seen only in the positive controls. CONCLUSION: The new caprolactone copolymer material is highly biocompatible.

Absorption↗

In vitro biocompatibility evaluation of a novel bicarbonate-buffered amino-acid solution for peritoneal dialysis.

BACKGROUND: Conventional lactate-buffered peritoneal dialysis fluids containing glucose as the osmotic agent have been shown to compromise important peritoneal host defence functions. The current study employed an in vitro model using activated peripheral blood mononuclear leukocytes (PBMC) for the preclinical biocompatibility assessment of a novel bicarbonate-buffered peritoneal dialysis fluid containing 1.0% amino acids as the osmotic agent. METHODS: PBMC (5 x 10(6)/ml) were pre-exposed (10-30 mm, 37 degrees C) to bicarbonate-buffered 1% amino-acid solution, bicarbonate- or lactate-buffered 1.5% glucose fluid, or control medium (RPMI). The cells were then washed and stimulated for 2 h at 37 degrees C in RPMI containing 100 ng/ml E.coli endotoxin from strain O55:B5. The cytokines IL-6 and TNF alpha in cell supernatants were assessed using specific enzyme immunoassays, cytokine mRNA expression by reverse transcription polymerase chain reaction. RESULTS: Short, i.e. 10 min, exposure to conventional, lactate-buffered glucose fluid resulted in a significant and time-dependent inhibition of cytokine release and mRNA expression by activated PBMC, whereas the cytokine response was improved even following prolonged (up to 2 h) exposure to bicarbonate-buffered 1% amino-acid solution or bicarbonate-buffered 1.5% glucose fluid. CONCLUSIONS: Our results suggest that very short, i.e. potentially clinically relevant, exposure to conventional dialysis fluid impairs the cytokine response by activated leukocytes. In this respect, the use of bicarbonate-buffered solutions containing 1.0% amino acids or 1.5% glucose may result in improved biocompatibility properties.

Amino Acids↗

In vitro mitochondrial test to assess haemodialyser biocompatibility.

BACKGROUND: This paper describes an in vitro mitochondrial test to assess the biocompatibility of haemodialysers. METHODS: We tested on isolated liver mitochondria the effect of solutions obtained by an aqueous rinse of different haemodialysers (cuprophane, cellulose acetate, Hemophan, polyacrylonitrile, polymethylmethacrylate, polysulphone, polyamide). Moreover, to determine the penetration into the cell and the cytotoxicity of these solutions from haemodialysers, we examined the effect of rinse solutions on HT29-D4 cells. RESULTS: Our results showed that rinse solutions from haemodialysers decrease the mitochondrial ATP synthesis. Cuprophane has the most marked effect, and the synthetic membranes exhibited only mild effects. Rinse solutions penetrated the cell and were cytotoxic by acting on mitochondria in the cell. In this respect, cellulosic membranes were the most toxic. CONCLUSION: Taken together our findings lead to a classification of haemodialyser membranes which is identical to one based on criteria such as activation of complement (cuprophane > other cellulosics > synthetics). Moreover isolated mitochondria make it possible to differentiate among the synthetic membranes. Isolated mitochondria thus appear to be a good in vitro test to assess the biocompatibility of haemodialysers.

Adenosine Triphosphate↗

Adequacy of dialysis reduces the doses of recombinant erythropoietin independently from the use of biocompatible membranes in haemodialysis patients.

BACKGROUND: The effect of the adequacy of dialysis on the response to recombinant human erythropoietin (rHuEpo) therapy is still incompletely understood because of many confounding factors such as iron deficiency, biocompatibility of dialysis membranes, and dialysis modality that can interfere. METHODS: We investigated the relationship between Kt/V and the weekly dose of rHuEpo in 68 stable haemodialysis (HD) patients (age 65+/-15 years) treated with bicarbonate HD and unsubstituted cellulose membranes for 6-343 months (median 67 months). Inclusion criteria were HD for at least 6 months, subcutaneous rHuEpo for at least 4 months, transferrin saturation (TSAT) > or = 20%, serum ferritin > or = 100 ng/ml, and haematocrit (Hct) level targeted to 35% for at least 3 months. Exclusion criteria included HBsAg and HIV positivity, need for blood transfusions or evidence of blood loss in the 3 months before the study, and acute or chronic infections. Hct and haemoglobin (Hb) levels were evaluated weekly for 4 weeks; TSAT, serum ferritin, Kt/V, PCRn, serum albumin (sAlb), and weekly dose of rHuEpo were evaluated at the end of observation. No change in dialysis or therapy prescription was made during the study. RESULTS: The results for the whole group of patients were: Hct 35 +/- 1.2%, Hb 12.1 +/- 0.6 g/dl, TSAT 29 +/- 10%, serum ferritin 204 +/- 98 ng/ml, sAlb 4.1 +/- 0.3 g/dl, Kt/V 1.33 +/-0.19, PCRn 1.11+/- 0.28 g/kg/day, weekly dose of rHuEpo 123 +/- 76 U/kg. Hct did not correlate with Kt/V, whereas rHuEpo dose and Kt/V were inversely correlated (r = -0.49; P < 0.0001). Multiple regression analysis with rHuEpo as dependent variable confirmed Kt/V as the only significant variable (P < 0.002). Division of the patients into two groups according to Kt/V (group A, Kt/V < or = 1.2; group B, Kt/V > or = 1.4), showed no differences in Hct levels between the two groups, while weekly rHuEpo dose was significantly lower in group B than in group A (group B, 86 +/- 33 U/kg; group A, 183 +/- 95 U/kg, P < 0.0001). CONCLUSIONS: In iron-replete HD patients treated with rHuEpo in the maintenance phase, Kt/V exerts a significant sparing effect on rHuEpo requirement independent of the use of biocompatible synthetic membranes. By optimizing rHuEpo responsiveness, an adequate dialysis treatment can contribute to the reduction of the costs of rHuEpo therapy.

Adult↗

Haemodialysis with the biocompatible high permeability AN-69 membrane does not alter plasma insulin-like growth factor-I and insulin-like growth factor binding protein-3.

BACKGROUND: Insulin-like growth factor-I (IGF-I) bioactivity has been reported to be decreased in maintenance haemodialysis patients and this may affect their nutritional status. Clearances of IGF-I and its binding proteins (IGFBPs) during haemodialysis sessions using a high permeability biocompatible membrane are unknown. METHODS: Five well nourished, non-diabetic adult patients were studied during one 4-h morning haemodialysis treatment using the high permeability biocompatible AN-69 dialyser. Blood was collected at the arterial and venous ports of the dialyser at 0, 1, 2 and 4 h of dialysis for haematocrit, plasma IGF-I, IGFBP-3 and insulin measurements. IGF-I, IGFBP-3 and insulin concentrations were adjusted for haemoconcentration before comparisons were made. RESULTS: At the beginning of the dialysis session, plasma IGF-I, IGFBP-3 and insulin levels were within the normal range (297 +/- 47 ng/ml (mean+/-SEM), 4.3 +/- 0.6 microg/ml and 11.8 +/- 3.4 microIU/ml, respectively). During the session, insulin tended to be cleared through the dialyser, whereas plasma IGF-I and IGFBP-3 values did not vary significantly. CONCLUSION: Dialysis with the high permeability AN69 membrane did not alter the main blood compounds of the IGF system in well nourished chronic haemodialysis patients, and it is unlikely that the malnutrition frequently observed in such patients would result from alterations of the IGF system during haemodialysis.

Acrylic Resins↗

Multidirectional approach to study peritoneal dialysis fluid biocompatibility in a chronic peritoneal dialysis model in the rat.

BACKGROUND: Peritoneal dialysis causes the functional and morphological changes in the peritoneum that result from the bioincompatibility of dialysis solutions. We present a model of chronic peritoneal dialysis in the rat that can be used for testing the biocompatibility of dialysis fluids. Methods and Results. Long-term exposure of the peritoneum to dialysis solutions can be performed in rats with implanted peritoneal catheters. Sampling of the dialysate allows the evaluation of intraperitoneal inflammation by examining cell differential and dialysate cytokine levels. Peritoneal permeability can be evaluated at designed time intervals with the peritoneal equilibration test (PET). At the end of dialysis, peritoneal histology is studied with light and electron microscopy. CONCLUSIONS: Such a multidirectional approach is an effective way to test biocompatibility of dialysis solutions.

Animals↗

Does the method of heparinisation influence the biocompatibility of dialysis membranes?

The biocompatibility of cuprophanc haemodialyser membranes was investigated during two haemodialysis sessions in ten stable male chronic haemodialysis patients. In one session heparin was given intravenously, while it was given in the arterial line in the other session, using the same amount of heparin and the same filter. Biocompatibility was determined by measuring platelet and leukocyte counts, plasma beta-thromboglobulin, C3d, elastase, and lactoferrin in the arterial line at 0, 10, and 90 min of dialysis, and in the venous line at 10 and 90 min. Adequate anticoagulation was ensured by determining activated partial thromboplastin time. Platelet counts remained unchanged, whereas leukocyte counts transitorily decreased during dialysis. Plasma beta-thromboglobulin, C3d, elastase, and lactoferrin increased during haemodialysis, but no differences could be found between the two methods of heparinisation. The activation of complement, platelets, and leukocytes seemed to be independent of the mode of heparinisation.

Adult↗

Comparison of blood biocompatibility during haemodialysis with cuprophane and polyacrylonitrile membranes.

Clotting within the dialyser is one of the most significant clinical parameters of biocompatibility. A study was designed to evaluate the biocompatibility of two different dialysis membranes (cuprophane and polyacrylonitrile) during therapy with conventional heparin. Transient leukopenia during cuprophane but not during polyacrylonitrile haemodialysis was observed, and elastase release using polyacryonitrile membranes was reduced (P less than 0.001). An elevation in F VIII:C activity during cuprophane haemodialysis has to be taken as an indication of endothelial disturbances. There was a significant (P less than 0.001) platelet activation (beta-thromboglobulin) and combined thrombin/plasmin generation using cuprophane membranes. This new synthetic polyacrylonitrile membrane inactivates the clotting in an extracorporeal system to a sufficient degree and allows a reduction in dosages of heparin. Platelet activation, platelet turnover, disturbances of endothelium, fibrinolysis activation, and granulocyte activation are reproducible parameters of a described interaction model. They also permit a comparison of different haemodialysis membranes.

Acrylic Resins↗

Effect of dialysis membrane biocompatibility on polymorphonuclear granulocyte activity in dialysis patients.

BACKGROUND: Among patients with defects of the phagocytic component of the immune system, chronic haemodialysis patients are highly susceptible to microbial infections characterized by high morbidity/mortality, related to an impairment of the phagocytic response. Therefore the potential influence of dialysis membrane biocompatibility on the activity of polymorphonuclear (PMN) granulocytes from dialysis patients was investigated in this study. METHODS: Nineteen patients in haemodialysis were included in the protocol and divided into two groups: a control group (7 patients) and a study group (12 patients). The study group patients were treated for subsequent periods of 1 month with different dialysis membranes: low flux excebrane E membrane (CL-E), low flux polysulfone (PS). The control group patients were treated with a low flux modified cellulose membrane (SMC) for the entire observation period. The aetiology of end-stage renal disease included glomerulonephritis, nephroangiosclerosis and interstitial nephropathy. Following each period of treatment, clinical and haematological parameters were evaluated; phagocytosis and microbicidal activity of PMNs from uraemic patients against Klebsiella pneumoniae, the pathogen which can pose severe problems in immune depressed patients, were investigated in parallel. RESULTS: The data evidence that both clinical and haematological parameters remained unchanged during the study period and no differences were found among treatments. On the contrary, the PMN activity varied according to the type of the membrane. In fact, the use of both PS and CL-E, in contrast to SMC, resulted in a PMN functionality similar to that observed in healthy subjects. CONCLUSIONS: These results provide evidence that the depressed PMN activities in dialysis patients may be influenced by membrane biocompatibility in such a way to be totally restored.

Aged↗

Biocompatibility of a new high-permeability modified cellulose membrane for haemodialysis.

The biocompatibility and solute permeability characteristics of a high-permeability modified cellulose membrane (Hemophan-HP) (He-HP) were compared with those of two synthetic membranes (poly(ethylene-co-vinyl alcohol) (EVAL) and poly(acrylonitrile-co-sodium methallyl sulphonate) (AN69)) and Cuprophan in a multicentre, four-way cross-over clinical trial. Cuprophan membranes caused significant complement activation, leukopenia, and granulocyte elastase release. He-HP membranes demonstrated a lesser effect, which was similar to that observed for the EVAL membrane, although less than that seen with the AN69 membrane. A similar order for the four membranes was seen for their effect on platelets. Cuprophan membranes provided superior small-molecule removal to the other three membranes. In contrast, Cuprophan was essentially impermeable to beta 2-microglobulin, whereas He-HP, EVAL, and AN69 allowed the removal of 60-90 mg of beta 2-microglobulin per treatment. However, a decrease in the plasma concentration of beta 2-microglobulin was observed only with the AN69 membrane, most probably as a result of the ability of that membrane to adsorb proteins. Our results demonstrate that high-permeability membranes of comparable biocompatibility to some synthetic membranes can be fabricated from cellulose derivatives.

Adult↗

Evaluation of the biocompatibility of a new method for heparin coating of a cardiopulmonary bypass circuit.

The biocompatibility of the Terumo (Terumo Corporation, Tokyo, Japan) covalent heparin coating method in a cardiopulmonary bypass (CPB) circuit was evaluated in ex vivo and in vivo experiments. In the ex vivo experiment, fresh human heparinized blood primed both a miniature heparin coated circuit (HCC) and the identical noncoated circuit (NCC), and was circulated simultaneously for 2 hr (n = 6). In the in vivo experiment, 10 rabbits underwent 2 hr of CPB under systemic heparinization (ACT > 400 sec) with HCC (n = 5) and with NCC (n = 5). In the ex vivo study, thrombin/anti-thrombin III complex, thromboglobulin, platelet factor IV, granulocyte elastase, and C3a were significantly lower in the HCC than in the NCC at 60 and 120 min of circulation (p < 0.05). In the in vivo study, platelet counts (percent of value at 10 min of CPB) were significantly higher in the HCC than NCC (HCC:NCC 87 +/- 10:71 +/- 12 at 60 min, 81 +/- 17:56 +/- 16 at 120 min). Scanning electron microscopic examination of the circuits showed less significant adhesion and pseudopod formation of platelets in the HCC than NCC in both ex vivo and in vivo situations. These results demonstrate that this heparin coated CPB circuit provides superior biocompatibility compared with a noncoated circuit by reducing the activation of the coagulation cascade, platelets, leukocytes, and complement.

Animals↗

Biocompatible surfaces using methacryloylphosphorylcholine laurylmethacrylate copolymer.

Many materials used in the medical device industry were not originally developed for these applications. In general, these materials elicit adverse biologic responses when in contact with body fluids such as blood, and the mechanisms of the response of blood to an artificial surface are well characterized. Protein adsorption, platelet adhesion, and activation of the coagulation pathway can subsequently lead to thrombus formation with grave clinical consequences in the absence of anticoagulant. However, the use of anticoagulants can result in complications. In recent years various approaches for overcoming these problems by improvement of the biocompatibility of materials have been advocated. One approach is that of biomembrane mimicry, whereby the surface of a material is coated with a derivative of phosphorylcholine (PC). PC is the major lipid head group component found in the outer surface of biologic cell membranes. In this paper, the application of PC coatings to a range of materials is discussed together with characterization of the surfaces using in vitro biocompatibility tests. Studies of fibrinogen and platelet binding have shown significant reductions in adsorption of these components to various PC coated materials relative to uncoated controls. Materials tested, amongst others, include PVC, polyethylene, polycarbonate, and nylon. The stability of the PC coatings has been studied using radiolabeled derivatives. Results using several materials show that physiadsorbed PC coatings are extremely stable, thus making the coatings suitable for use in a wide variety of medical applications. Extensive biologic evaluations to assess the toxicologic profile of PC derivatives and coated devices have also been carried out and in all tests the materials have been shown to be nontoxic, thus making them suitable for human use. Ex vivo animal and human studies performed support the in vitro data.

Adenosine Triphosphate↗

Application of a new dynamic flow model for investigating the biocompatibility of modified surfaces.

An in vitro model was developed to compare the biocompatibility of four different coating methods (three heparin and one nonheparin) under hemodynamic conditions. Fresh human donor blood (heparin 5 IU/ml) was recirculated in a standardized experimental circuit. All circuit components were either coated or remained uncoated for control purposes. The aim of the study was to investigate a wide spectrum of effects on blood; coagulation parameters (e.g., fibrinogen, ATIII, thrombin-antithrombin-complex), complement parameters (C1rsC1 Inh, C3b(Bb)P, SC5b-9, C5a), differential blood analyses, platelet activation (flow cytometric investigations), PF 4, and PMN-elastase release were examined by showing possible trends. All heparin coated systems reduced platelet stimulation in comparison to untreated biomaterials. Leukocyte activation was reduced to different degrees depending upon the coating method used. Complement activation was markedly reduced by all coated systems. The results obtained indicate that the pump driven, dynamic blood flow model is suitable to characterize the biocompatibility of surface modified biomaterials. Advantages lie in the integration of the different polymers as parts of the circuit, the low priming volume, and the generation of blood flow conditions similar to those that occur in clinical applications.

Biocompatible Materials↗

Coculture system to assess biocompatibility of candidate orthopaedic materials.

When examining the biocompatibility of materials for orthopaedic use, it is important to examine the in vitro response of osteoblasts and macrophages to the material. The purpose of the current study was to develop an in vitro system that more accurately models the dynamic macrophage and osteoblast interactive response to biomaterials. A filter coculture system was designed that enables two cell types to be separated, while permitting cellular mediators to diffuse through its porous membrane. Using the filter coculture system, macrophage and osteoblast interaction in response to polymethylmethacrylate particle exposure was examined. As a marker of bone resorption potential, the level of prostaglandin E2 released from the macrophage and osteoblast coculture was compared with traditionally used in vitro culture systems. Cells interacting in the filter coculture system were found to produce prostaglandin E2 levels significantly greater than those of traditional conditioned media transfer systems. This filter coculture system offers an in vitro model that accounts for the continual cell to cell mediator interaction of two cell types simultaneously exposed to an implant material. This system may be useful in examining the biocompatibility of candidate materials at the bone interface, and thus elucidating the mechanisms of material induced bone resorption.

Animals↗

Biocompatibility of various indwelling double-J stents.

The biocompatibility of 8 double-J stent brands was evaluated both in vivo, by scanning electron microscopy and histological analysis of pig ureters intubated for 6 weeks, and in vitro, by cell culture methods. In vivo findings showed that superficial epithelial destruction was milder in the ureters intubated with hydrogel-coated stents than in those intubated with other stents. Inflammatory reactive changes were milder in the ureters intubated with silicone stents than in those intubated with other stents, while encrustation was more severe on silicone and Grey stents than the others. In vitro, the 3 stent brands made of "modified polyurethane" were found to be cytotoxic while the others were not. Overall, silicone and hydrogel-coated stents seemed to be more biocompatible than the others, and hydrogel-coated stents to be more suitable than silicone stents for long-term ureteral stenting, being less prone to encrustation. Although they are of an experimental nature, these findings may be of relevance to clinical practice.

Animals↗

Determining the influence of biocompatible oxygenators during cardiopulmonary bypass by 99m Tc-DTPA aerosol assessment of pulmonary permeability.

Changes in pulmonary permeability provide a partial measure of the clinical impact of biocompatible oxygenator use during cardiopulmonary bypass surgery. Previous research has shown that the clearance rate of 99mTc-labelled diethylene triamine penta-acetic acid (99mTc-DTPA) aerosol from the lungs is increased following cardiopulmonary bypass, resulting from an increase in pulmonary permeability. The aerosol clearance rate has been shown to return to normal after a period of 7 days. A blind trial was set up to assess the clinical impact of a biocompatible, Trillium-coated oxygenator compared with a standard oxygenator. In a group of 25 patients 99mTc-DTPA aerosol studies were carried out prior to cardiopulmonary bypass surgery for mitral valve surgery. Repeat studies were undertaken 3-4 h and 24-28 h after surgery. Analysis of the rates of pulmonary clearance reproduced the trends seen in earlier research. There was however no statistically significant difference in the variation of serial clearance times between the groups of patients undergoing surgery using the Trillium-coated oxygenators and those using the standard oxygenators.

Aerosols↗