Acute myocardial infarction with cardiogenic shock during pregnancy: treatment with intra-aortic balloon counterpulsation.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Hemodynamically unstable patients supported by an extracorporeal life support (ECLS) circuit often receive additional support by intra-aortic balloon pump (IABP). However, it is not established whether support of the failing heart is improved by adjunctive IABP in both peripheral cannulation (PC) and central cannulation (CC) settings. Seven sheep were supported by an IABP and an ECLS system which were cannulated centrally as well as peripherally. In each cannulation configuration, hemodynamic and cardiac function indices were measured at baseline, ECLS, and ECLS plus IABP. The primary variables were mean coronary artery flow (Qcor), diastolic pressure time index (DPTI), left ventricular (LV) pressure-volume area (PVA), and tension time index (TTI). Additional IABP with ECLS support (CC/PC) decreased LV afterload (LV systolic peak pressure -4%, P<0.05/-8%, P<0.02), as well as TTI -2%/-10% and PVA -10%/-12% (P<0.03). Coronary perfusion was increased by additional IABP: CC, Qcor, +9%, and DPTI, +18% (P<0.02); PC, Qcor,+6%, and DPTI, +11% (P<0.05). IABP augmented the myocardial oxygen supply/demand ratios (CC/PC): Qcor/(PVA.heart rate) (+21%/+22%, P<0.02) and DPTI/TTI (+27%/+24%, P<0.03). In case of low arterial pressure (<50 mm Hg) and reduced ECLS flow, the overall hemodynamic profile improved only with central cannulation. We conclude that in both central and peripheral ECLS cannulation settings, adjunctive IABP improves the myocardial oxygen supply demand balance. In case of low cardiac output and insufficient extracorporeal flow with PC, adjunctive IABP may be contraindicated.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Severe maneuvers designed to enhance the applicability and effectiveness of intraaortic balloon pulsation are presented. (1) Insertion of balloon catheter directly into the ascending aorta. The technique uses an indwelling silastic snare that allows direct insertion of a balloon catheter into the ascending aorta in the course of open heart operations without the necessity of returning the patient to the operating room and reopening the chest at the time of balloon catheter removal. (2) Elimination of electric artifacts in the course of intraaortic balloon assist. A method is presented that utilizes optical rather than electric signals to operate the intraaortic balloon pump and eliminates pacer interference as well as other electrical artifacts. (3) Enhancing assist effectiveness by balloon positioning. In a series of clinical observations, it was found that the effectiveness of balloon assist may be enhanced by as much as 75% by appropriate positioning. The previously held concept that placing the balloon in a subclavian location is optimal is challenged and it is recommended that the proper position of the balloon catheter be determined by using appropriate hemodynamic measurements in different locations. (4) Control of bleeding following removal of percutaneously inserted transfemoral balloon catheter. The technique utilizes a balloon catheter which is introduced into the puncture hole of the femoral artery after minimal surgical dissection and allows direct suturing of the bleeding source.
Six normal subjects and 12 patients with clinical angina and significant ST depressions during baseline ambulatory cardiac monitoring were given a single treatment with the end-diastolic pneumatic compression boot, the Circulator Boot. With the use of continuous electrical impedance measurements, multiple hemodynamic variables were followed in five situations: (1) baseline before pumping; during end-diastolic pumping (2) on both legs after every heartbeat, (3) on one leg after every heartbeat, and (4) on both legs on alternate beats; and (5) during pumping on both legs during every systole. Both an increase in venous return and a reduction in afterload likely contributed to significant increases in cardiac output (CO) (51.1 +/- 33.6%), stroke volume (SV) (52.1 +/- 35.6%), change in impedance over time (dZ/dT) (72.0 +/- 68.1%), cardiac index (CI) (51.2 +/- 33.8%), and acceleration index (50.7 +/- 62.2%) during end-diastolic pumping on both legs after every heartbeat. A crucial role for afterload reduction was implied by opposite effects observed on CO, CI, dZ/dT, and SV during systolic pumping. Again, reductions (or a lack of an increase) in ventricular ejection time and/or the preejection period suggested a decrease in afterload during end-diastolic pumping. Pumping on one leg after every beat and on both legs on alternate beats was also effective but less so. After the initial study, the patients were given 14 additional end-diastolic treatments to both legs over 3 weeks. A clinical benefit for the patients was shown by symptomatic improvement in all patients along with a significant reduction in the amount and duration of the RST abnormalities in their ambulatory heart monitoring (p = 0.012).
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A two-center elective coronary angioplasty experience with intra-aortic balloon pump support for patients with severe left ventricular dysfunction is reported. To prevent hemodynamic collapse, an intra-aortic balloon pump was inserted percutaneously before coronary angioplasty in 97 patients with a left ventricular ejection fraction less than 35% (26% of whom had ejection fractions less than 25%). The cohort was predominantly male (71%) with a mean age of 64 +/- 9 years. Angioplasty was successfully performed in 83 (85.6%) patients and 80 (82.5%) of these successful patients were discharged from the hospital. Seven patients had unsuccessful angioplasty without a major cardiac event. Seven patients (7.2%) suffered a major cardiac event; 4 had emergent coronary bypass surgery with q-wave infarction, 2 had uneventful emergency coronary bypass surgery, and one patient died in the operating room after a failed angioplasty. Using logistic regression analysis, the presence of multivessel disease and a history of prior myocardial infarction were associated with more complications during angioplasty (p less than 0.05). Intra-aortic balloon pump placement did not interfere with the angioplasty procedure. Two patients had limb ischemia which resolved when the intra-aortic balloon pump was removed. Of the 80 successful patients discharged, 72 were followed for a mean of 22 months. At the latest follow-up, 52 had not suffered a myocardial infarction and were alive. Of the 20 late deaths, 16 were cardiac and 4 non-cardiac.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.