PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particle Size”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Rheology of PVC Plastisol: Particle Size Distribution and Viscoelastic Properties.

Plastisols of poly(vinyl chloride), PVC, are suspensions of fine particles in plasticizer with about 50% resin volume fraction. Typically, the gross particle size ranges from 15 to 0.2 &mgr;m and smaller, where the common practice of spray-drying these resins and subsequent grinding of larger particles dictate the size ranges including agglomerates as well as the primary particles. The plastisol is a pastelike liquid, which may be spread to coat substrates. The coated substrates are heated in an oven to gel and fuse the material for producing uniform, rubbery products. Because the first step of processing is spreading the plastisol on a substrate, rheology at room temperature is obviously important. The material is thixotropic under very low stress. The flow behavior is pseudoplastic and exhibits dilatancy and fracture at high shear rate. This work is concerned with the pseudoplastic behavior but the dynamic mechanical measurements are employed instead of the usual steady-state shear flow measurements. This is because the steady shear may break up agglomerates. The dynamic measurements with small strain-amplitude avoid the break-up of the agglomerates. This is important, because this work is concerned with the effects of the particle size distribution on the material behavior. The frequency dependence of both viscous and elastic behavior is recorded and presented with samples varying in particle size distribution. Copyright 2001 Academic Press.

Journal Article↗

A crossover study comparing the effect of particle size on the distribution of radiocolloid in patients.

Two radiocolloid preparations, differing in particle size by a factor of 5 to 20, were compared in each of 15 patients. The smaller colloid, measuring less than 80 nm, showed a relative decrease in the calculated target to background ratios for the liver and spleen and an increase for the bone marrow. The increased uptake of the smaller particle in the bone marrow, as measured by the bone marrow to soft-tissue background ratio, was about 50% higher than that of the larger colloidal particles. Comparable marrow images can be obtained in a half to a third of the time with the smaller particle size for a given administered dose.

Adult↗

Retention and transport of amphiphilic colloids under unsaturated flow conditions: effect of particle size and surface property.

The purpose of this study was to examine the mechanisms responsible for deposition and transport of amphiphilic colloids with a wide range of particle sizes (20-420 nm) through porous media. A series of saturated and unsaturated column experiments were conducted using amphiphilic latex microspheres and a hydrophilic silica colloid. We found that the amphiphilic latex particles were retained to a greater extentthan the hydrophilic silica colloid in unsaturated media. This was attributed to colloidal attachment atthe air-water interface due mainly to hydrophobic interactions. We also found that dependence of colloid retention on particle size was nonlinear. There existed a fraction of colloids with greater mobility than other fractions, which we referred to as the most mobile colloids. As particle size increased from 20 to 420 nm, colloid deposition rate first decreased to reach a minimum value at --100 nm then increased, indicating that different retention mechanisms were involved. We showed that conducting saturated transport experiments and analysis using filtration theory may be an effective approach for determining the most mobile colloid size(s) in porous media, perhaps even for unsaturated flow conditions. This study highlights the importance of including size effect and surface properties when predicting concentrations and fluxes of amphiphilic colloids or colloid-bound amphiphilic and hydrophobic contaminants in the subsurface environment.

Colloids↗

Perfluorocarbon species and nebulizer type influence aerosolization rate and particle size of perfluorocarbon aerosol.

PURPOSE: Aerosolization of perfluorocarbons (PFC) has been proven beneficial in vivo. The present in vitro study was performed to investigate, how PFC-aerosolization is affected by type of nebulizer and PFC properties. MATERIALS AND METHODS: Aerosolization rate was studied of 4 different PFC that were nebulized using 3 different jet nebulizers (operating at different flows: 4.1; 7.1; 13 l/min) and one ultrasonic nebulizer. Distribution of aerosol particle size was determined with a laser diffraction device. RESULTS: Between the studied nebulizers, considerable differences in the aerosolization rate were found. Aerosolization rate was significantly lower for PFOB (0.48-1.24 mL/min), when compared with PF 5080, RM 101 and FC 77 (1.33-4.75 mL/min). The ultrasonic nebulizer did not generate an aerosol but rather PFC vapor. Lowest mass median diameter (MMD) was found for PFOB and varied between the jet nebulizers from 2.2 and 3.7 microm, with a small range in particle size (maximum of 7.3 microm). FC 77 had highest MMD (3.5 to 9.2 microm) and greatest range of particle size of up to 13 microm. CONCLUSIONS: Our in vitro data show that aerosolization rate depends mainly on density of PFC and the flow of nebulizer. Particle size distribution is affected by PFC properties. Our result may explain controversial results of published in vivo studies.

Administration, Inhalation↗

Effect of particle size on performance. 1. Corn.

The effect of diets prepared with corn ground in a hammer mill and sieved to obtain "coarse", "medium", and "fine" particle size fractions, on broiler performance from hatch to 7 d and from 7 to 21 d of age was studied. Five diets differing in geometric mean diameter (GMD) or geometric standard deviation (GSD) were assayed. The best performance in both age groups studied was obtained with the diet prepared from medium corn. In this diet the GMD was .769 mm, quite similar to those of two other diets (GMD .793 and .706 obtained by mixing the original corn with 18 or 36% "fine" fraction) with which lower performance was obtained. The uniformity of the particle size (described by the GSD) also had a positive effect on performance. The improved performance obtained with the diet containing the medium corn particle size could be partly attributed to lower GSD, which was 1.63 vs about 2.00 in the other diets.

Animal Feed↗

The effect of bovine lung heparin on normal human platelets as measured by electronic particle size analysis.

The response of normal human platelets to treatment with bovine lung heparin was evaluated using electronic particle size analysis and aggregometry. Samples for electronic particle size analysis were obtained both before and after the addition of heparin to platelet-rich plasma (PRP). The number of single platelets decreased significantly after the addition of heparin to PRP obtained from 22 individuals. This decrease averaged 18% in 19 samples which did not show a significant increase in transmittance and was at least 70% in 3 samples which showed a significant increase in transmittance. The size distribution of single platelets was not significantly altered. In addition, electron microscopic examination revealed that platelets treated with heparin are activated.

Adenosine Diphosphate↗

Characteristic study of ionic species in nano, ultrafine, fine and coarse particle size mode at a traffic sampling site.

A micro-orifice uniform deposit impactor (MOUDI) and a nano-MOUDI were used to measure the atmospheric coarse (PM2.5-10), fine (PM2.5), ultrafine (PM0.056-1) and nano (<0.056 microm) particle concentrations at a traffic sampling site in central Taiwan during the winter period from November 2004 to January 2005. Meanwhile, concentrations of major ionic species (Cl-, NO3-, SO(2-)4, NH4+, Na+, K+, Ca2+ and Mg2+) were also extracted from various particle size modes (nano, ultrafine, fine and coarse) and analysed by ion chromatography (DIONEX-100). The mass size distribution of ambient suspended particles exhibited two modes. The size ranges of the particles at these two particle size modes were between 1.0 and 1.8 microm and 3.2 and 5.6 microm, respectively. The average mass media aerodynamic diameter (MMAD) of suspended particles was 0.99 microm in this study. In addition, statistical methods, such as correlation coefficient and principal component analysis, were also used to identify the possible pollutant source for various particles size modes (nano, ultrafine, fine and coarse) during the winter months at a traffic sampling site in central Taiwan.

Air Pollutants↗

The role of particle size distribution on bioavailability of cyclosporine: novel drug delivery system.

During the long period of cyclosporine-containing dosage forms development a lot of significant findings have been done especially in the field of drug delivery systems. Currently available drugs are based, from technological point of view, on self-dispersible drug delivery systems, which contain cyclosporine solved in pharmaceutically acceptable vehicle. One can find difference among particular systems a) at particle size distribution after dispergation, b) at composition and c) at bioavailability of cyclosporine. As far as improvement of bioavailability between original brand leader formulation Sandimmune and recent brand leader formulation Neoral was followed by significant improvement in particle size distribution it was generally assumed that the reason for this improvement have been found. Several other formulations e.g. Consupren or SangCyA--self-dispersible systems, more or less correspond with above mentioned theory that smaller is better and by this principle bridged liquid based dosage forms with solid dosage forms. Bioavailability of novel drug delivery system which gives coarse dispersion with average particle size between 1-150 microns when dispersed have been tested on healthy volunteers. No difference among pharmacokinetic parameters of novel drug delivery system and microemulsion system have been observed in spite of fact that average particle size of novel system is almost 1000x bigger.

Adult↗

Effect of sorghum particle size on digestibility of nutrients at the terminal ileum and over the total digestive tract of growing-finishing pigs.

The effect of sorghum particle size on nutrient digestibilities at the terminal ileum and over the total digestive tract of growing-finishing pigs were investigated in a replicated 3 X 3 Latin square trial. Sorghum-casein diets were used. Sorghum was dry rolled (C) or ground in a hammer mill through 6.4 mm (M) or 3.2 mm (F) screens, producing particles with a modulus of fineness of 3.57, 2.85 or 2.36, respectively. Each successive reduction in particle size improved (P less than .05) the apparent ileal digestibility of dry matter, starch, gross energy and N. Measured over the total digestive tract, digestibilities of these components were highest (P less than .05) for the F diet but they did not differ (P greater than .10) between diets M and C because of increased (P less than .05) disappearance in the large intestine of dry matter, starch and gross energy from the C diet. N loss in the large intestine was also higher for pigs fed diet C than for those fed diet M, but the difference was not significant. The digestibilities of most amino acids at the terminal ileum were improved (P less than .05) as particle size decreased. Lysine digestibilities were not affected (P greater tha .10). Amino acid digestibilities measured over the total digestive tract were consistently higher (P less than .05) for diet F than diets M and C, which did not differ (P greater than .10) from one another. A comparison of ileal and total tract digestibilities indicated a net disappearance of all measured amino acids except lysine during large intestine transit. These data indicate that increasing fineness of grind will improve digestibility of nutrients in sorghum by growing-finishing pigs.

Amino Acids↗

The effect of particle size and concentration on the adhesive characteristics of a model drug-carrier interactive system.

The effect of concentration and particle size on the adhesive tendency of drug particles in a model interactive system was investigated using a centrifuge technique. The model interactive system consisted of drug powders adhered to coated glass carrier beads. Adhesion profiles of per cent of drug remaining on the carrier versus the square of the speed of rotation were a logarithmic normal function. Increase in the adherent particle size and concentration decreased the adhesive tendency of all drug powders studied. Particle collisions during detachment and the formation of multiparticulate layers even before the monolayer saturation of the carrier surface were responsible for the reduced adhesive stability of the drugs on the carrier as the particle loading increased.

Adhesiveness↗

Particle size determination by automated microscopical imaging analysis with comparison to laser diffraction.

A rapid and precise microscopical analysis technique for the determination of particle size distribution has been developed. Particle size distribution was determined with a Carl Zeiss Axioplan microscope equipped with a computer-controlled image analysis system. Area and volume measurements were performed on a number of particles and plotted against Feret's diameter to yield a distribution histogram. This technique was then applied to several compounds of pharmaceutical interest, and the resulting histograms were compared with histograms determined with a laser diffraction instrument. The reproducibility of the microscopical determination was good and the agreement between the two determinations was dependent on the crystalline shape.

Crystallization↗

Direct extraction of the mean particle size from a digital hologram.

Digital holography, which consists of both acquiring the hologram image in a digital camera and numerically reconstructing the information, offers new and faster ways to make the most of a hologram. We describe a new method to determine the rough size of particles in an in-line hologram. This method relies on a property that is specific to interference patterns in Fresnel holograms: Self-correlation of a hologram provides access to size information. The proposed method is both simple and fast and gives results with acceptable precision. It suppresses all the problems related to the numerical depth of focus when large depth volumes are analyzed.

Journal Article↗

The influence of sampling chamber dimensions on aerosol particle size measurement by cascade impactor and twin impinger.

The influence of the sampling chamber dimensions upon particle size estimation by cascade impaction has been investigated and compared with measurements by the twin impinger. Aerosols of salbutamol and disodium fluorescein (DF) were generated from pressurized metered dose inhalers. The mass median aerodynamic diameter (MMAD) by the Andersen Impactor for salbutamol ranged from 2.0 to 2.8 microns with geometric standard deviations (g.s.d.) of 1.7 to 2.4. These observations were independent of the distance travelled to the first impaction surface of the impactor and volume of the sampling chamber. The DF MMAD ranged from 5.0 to 6.9 microns with g.s.d. values of 1.7 to 1.8. Changes in droplet size within the sampling chamber may cause significant differences in particle size estimates as indicated by the cascade impaction data for DF. The respirable fraction of the salbutamol samples was similar whether determined by impaction or using the impinger. The latter device has previously been indicated to give clinically relevant estimates of respirable fraction for commercial inhalation aerosol devices.

Aerosols↗

Chromate content versus particle size for aircraft paints.

Many industries rely on the corrosion inhibiting properties of chromate-containing primer paints to protect metal from oxidation. However, chromate contains hexavalent chromium (Cr(6+)), a known human carcinogen. The concentration of Cr(6+) as a function of paint particle size has important implications to worker health and environmental release from paint facilities. This research examines Cr(6+) content as a function of particle size for three types of aircraft primer paints: solvent-based epoxy-polyamide, water-based epoxy-polyamide, and solvent-based polyurethane. Cascade impactors were used to collect and separate paint particles based on their aerodynamic diameter, from 0.7 to 34.1 microm. The mass of the dry paint collected at each stage was determined and an atomic absorption spectrometer was used to analyze for Cr(6+) content. For all three paints, particles less than 7.0 microm contained disproportionately less Cr(6+) per mass of dry paint than larger particles, and the Cr(6+)concentration decreased substantially as particle size decreased. The smallest particles, 0.7 to 1.0 microm, contained approximately 10% of the Cr(6+) content, per mass of dry paint, compared to particles larger than 7.0 microm. The paint gun settings of air to paint ratio was found to have no influence on the Cr(6+) bias.

Aircraft↗

Dependence on particle size in the phagocytosis of latex particles by rabbit alveolar macrophages cultured in vitro.

The dependence of the phagocytosis of particulate materials on their size was studied. Rabbit alveolar macrophages (AMs) obtained by lung lavage were cultured in suspensions or monolayers with Latex particles of 1 micron or 2 microns in diameter. After culturing AMs with 10(7)(-5) X 10(9) Latex particles per ml for 15 to 360 minutes, the number of phagocytized particles in each of 100 individual cells was counted by light microscopy. In suspension culture, there was no significant difference in the average number of particles phagocytized per AM between 1 micron and 2 microns particles in the identical conditions as to the particle concentration (particle number/ml) and the incubation time. In monolayer culture, it was difficult to compare the average number of 1 micron particles phagocytized by AM with that of 2 microns ones in the identical condition as to the particle concentration, since the sedimentation velocities at which particles sank to the bottom of culture chamber were different between both particles, resulting in the difference of particle concentration around AMs. The sign of saturation was observed when the average number of phagocytized particles reached approximately 10 particles per AM in either case of suspension culture with 1 micron or 2 microns particles and approximately 45 of 1 micron and 10 of 2 microns particles in monolayer culture.

Animals↗

Human amelogenesis: high resolution electron microscopy of nanometer-sized particles.

Growth of inorganic crystals of enamel is described as a two-stage process with growth of ribbon-like crystals in length and width, followed by their development in thickness. In early stages of crystal growth during human amelogenesis nanometer-sized particles with a mean diameter of 1.1 nm were described between ribbon-like crystals. These small particles had a crystalline structure but their lattice parameters did not seem to be directly related to those of calcium phosphates. The nanometer-sized particles appear to correspond to initial stages of apatite crystal growth. Their localization close to ribbon-like crystals and their progressive increase in size and number may indicate that they represent a precursor phase for these crystals. Nucleation areas at both extremities, of elongated ribbon-like crystals could be involved in the two-directional growth of ribbons and/or in nanometer-sized particle nucleation.

Amelogenesis↗

Measurements of particle-size distribution and concentration by transmission fluctuation spectrometry with temporal correlation.

A new method of transmission fluctuation spectrometry with signal correlation was recently developed for particle-size analysis, whereby both particle-size distribution and particle concentration can be measured simultaneously. The measurements were realized with temporal correlation of the transmission fluctuation signals of a focused Gaussian beam.

Journal Article↗

Ultrasonic diffraction grating spectroscopy and the measurement of particle size.

The results of measurements using ultrasonic diffraction grating spectroscopy (UDGS) are found to be dependent upon the particle size of the slurry. This illustrates the emergence of a new technique for measuring particle size. Theoretical calculations are underway to describe and predict them as well. The ultrasonic grating surface is in contact with the slurry. The diffraction grating was formed by machining triangular grooves with a periodicity of 483 microm on the flat surface of an aluminum unit with send and receive transducers fastened to it. For this experimental configuration, the ultrasonic beam strikes the back of the grating at an incident angle of 30 degrees and produces a transmitted beam of spectral order m=1 in the slurry. The angle of this transmitted beam changes with frequency and, at the critical frequency of 3.47 MHz, it is located at an angle of 90 degrees. The receive transducer measures the reflected m=0 beam at an angle of 30 degrees. At a frequency slightly less than the critical frequency, the m=1 transmitted beam no longer exists and its energy is shared with all other beams. Therefore, due to energy conservation, the signal in the receive transducer exhibits a peak at the critical frequency. During the transition, the wave interacts with the particles of the slurry and ultrasound amplitude is reduced. Therefore, the peak observed by the receive transducer is reduced, compared to that for water. Data have been obtained for slurries of polystyrene spheres, ranging in size from 215 microm to 463 microm, and for weight percentages of 1-12%. Polystyrene spheres of different diameter show differing amounts of energy loss and thus, particle size identification is possible.

Journal Article↗