PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Silicon Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Epidemiologic studies of environmental agents and systemic autoimmune diseases.

Systemic lupus erythematosus and systemic scleroderma are autoimmune diseases thought to have an exogenous trigger. This review summarizes relevant case-control and cohort studies that investigated exogenous sex hormones, silica, silicone, solvents, pesticides, mercuric chloride, and hair dyes as putative risk factors for the development of these diseases. These studies indicate that estrogen replacement therapy in postmenopausal women increases the risk of developing lupus, scleroderma, and Raynaud disease, although the increase in risk is relatively modest. Oral contraceptives may also play a role in disease susceptibility in lupus but not apparently in scleroderma. Environmental endocrine modulators, in the form of pesticides, may represent another opportunity for estrogenlike effects to occur, but there is scant evidence that these agents play a role in human systemic autoimmune disease. Although exposure to silica dust increases the risk of scleroderma in men occupied in the industry, this does not explain most male scleroderma cases. When this exposure was investigated among women, no significant risk was found. Additionally, silicone in implanted devices as well as occupational exposure to silicone-containing compounds did not pose an increased risk among women for scleroderma. The role of solvent exposure has been investigated as a risk factor for scleroderma with mixed findings. One study suggested a potential role in male patients or in those individuals with Scl-70 antibody positivity either male or female. Two other studies were unable to corroborate this finding. Mercuric chloride causes antifibrillarin antibodies and immune complex glomerulonephritis in susceptible mouse strains. Antifibrillarin antibodies, but not glomerulonephritis, occur in a subset of scleroderma patients and preliminary evidence suggests that mercury levels may be higher in this group of individuals. Hair products have been studied as possibly raising the risk of developing lupus, since such products contain an aromatic amine similar to a compound known to cause drug-induced lupus. A 1986 study suggested a positive association, but two subsequent studies did not support this association.

Animals↗

Stereoselective synthesis of allyl-C-mannosyl compounds: use of a temporary silicon connection in intramolecular allylation strategies with allylsilanes.

Methyl mannoside 16 containing an allyldimethylsilyl ether at C(2) was synthesized in nine steps from D-mannose. Reaction with TMSOTf in MeCN at room-temperature effected C-glycosylation to provide the alpha-allyl-C-mannosyl product 18 with excellent stereoselectivity. Crossover experiments over a range of reaction concentrations proved that reaction was proceeding via an intermolecular pathway rather than the hoped-for intramolecular delivery route. The exceptionally high stereoselectivity of this allylation in the presence of an acid-scavenger, 2,6-DTBMP, can be attributed to the allylsilyl ether 16 behaving as the allylating agent. Geometrical constraints in the seven-membered ring transition state account for the lack of intramolecular allyl transfer. Attaching a modified allylsilane 29a-c to C(2)OH of methyl mannoside 15 improved matters. Reaction of the tethered mannosides 27a-c with TMSOTf in the presence of 2,6-DTBMP in MeCN at rt provided a range of products, which depended on the size of the alkyl substituents at the silyl ether tether. Diene products were the major compounds irrespective of the size of the alkyl substituents at the silyl ether tether. Their formation can be understood by intramolecular allylation of the allylsilane on to the activated anomeric center, followed by collapse of the intermediate carbocation by preferential attack of an external nucleophile at the silyl ether tether, rather than at the allylic silicon center. A cascade of further reactions rationalizes the formation of the 2-dienyl-substituted tetrahydrofuran 30 and dienes 39 and 40. The desired beta-allyl-C-mannosyl products 42 and 43 were obtained, albeit in low yield, when bulky ethyl and isopropyl groups were employed at the silyl ether tether. Stereospecific oxidative cleavage of the silyl tether in 42 and 43 provided the corresponding stereodefined diols 44 and 45, respectively. Attempts to improve the yield and diastereoselectivity of the desired beta-allyl-C-mannosyls by moving to a sulfoxide mannosyl donor, which could be activated at low temperature, proved unsuccessful.

Journal Article↗

Interactions of pigments and opacifiers on color stability of MDX4-4210/type A maxillofacial elastomers subjected to artificial aging.

STATEMENT OF PROBLEM: The color instability and degradation of maxillofacial elastomers limit the function and cosmetic quality of facial prostheses. PURPOSE: The purpose of this study was to measure the interactions of oil pigments plus dry earth opacifiers at 5%, 10%, and 15% by volume in stabilizing the color of MDX4-4210/type A silicone elastomers before and after artificial aging. MATERIAL AND METHODS: In the first part of the study, each of 5 opacifiers (Georgia kaolin powder neutral, kaolin powder calcined, Artskin white, dry pigment titanium (Ti) white, or Ti white artists' oil color) at 10% concentrations were combined with each of 5 oil pigment types (no pigment, cadmium-barium red deep, yellow ochre, burnt sienna, or a mixture of the 3 pigments), for a total of 25 experimental groups of elastomers. In the second part of the study, 50 experimental groups of elastomers were made by combining 1 of 5 opacifiers at 5% and 15% concentrations with 1 of 5 oil pigments as in Part 1. Five specimens of each elastomer were tested, for a total of 375 specimens. In each part of the study, all specimens were aged in an artificial aging chamber. CIE L*a*b* values were measured by a spectrophotometer. The color differences (DeltaE*) were subjected to repeated-measures analysis of variance. Mean values were compared by Tukey-Kramer intervals (alpha = .05). RESULTS: In Part 1, when the opacifiers were tested at 10% concentration, Ti white oil color had the most color change, and dry pigment Ti white had the least; all other opacifiers were not significantly different from each other. In Part 2, at 5%, Ti white oil color had the most color change; all other opacifiers were not significantly different from the others. At 15%, Ti white oil color again had the most color change, followed by Artskin white, kaolin powder calcined, and Georgia kaolin; Ti white dry earth pigment had the least color change. Overall, 5% Artskin white had less color change than the 15%, whereas 15% dry pigment Ti white had less color change than the 5% (P < .001). The 5% and 15% of other opacifiers were not significantly different. CONCLUSIONS: At all 3 concentrations, oil pigments mixed with opacifiers helped protect the MDX4-4210/type A silicone elastomer from color degradation over time. Dry pigment Ti white remained the most color stable over time, followed by the pigments mixed with kaolin powder calcined, Georgia kaolin, Artskin white, and Ti white artists' oil color.

Barium Sulfate↗

Development of a silica-free silicone system for medical applications.

Filler-free silicones are believed to be more blood-compatible than those containing fillers. An ultrapure silica-free room temperature vulcanizing silicone system was prepared and characterized using a swelling experiment, an infrared spectrometer, an x-ray spectrometer, a scanning electron microscope and neutron activation analysis. The polymer was found to be suitable for medical applications needing an extremely smooth surface.

Biocompatible Materials↗

Silicate nephrotoxicity in the experimental animal: the missing factor in analgesic nephropathy.

Three silicon-containing compounds (magnesium trisilicate BP, crushed quartz and crushed Arran granite) were added to the drinking water (250 mg/l) of three groups of male guinea pigs for four months. At autopsy all animals receiving magnesium trisilicate showed a focal tubulo-interstitial nephritis mainly affecting the distal nephron. Similar but less intense lesions were encountered in two animals receiving crushed quartz. No renal lesions were found in the control group or in animals receiving crushed Arran granite. The concentration of soluble silicates in drinking water, measured as elemental silicon (Si) by atomic absorption spectroscopy (AAS) was determined for twenty-eight locations in different regions of Britain. Following ingestion of magnesium trisilicate, significant increases in urinary excretion of Si were demonstrated in two healthy adults using atomic absorption spectroscopy.

Animals↗

High resolution electronic absorption spectra of aniline, anilino and silicon dioxide.

High resolution electronic absorption spectra of aniline and anilino free radical have been recorded in the vapor phase at room temperature by flash photolysis technique, and subsequent reactions have been investigated by kinetic spectroscopy. It was possible to follow the kinetics of the anilino radical's decay which occurred predominantly by bimolecular recombination. Decay parameters of anilino free radical were measured from the absorption bands.

Aniline Compounds↗

Occupational renal diseases.

There is no doubt that particular occupational exposures may induce acute renal effects. The role of occupational exposure in the development or progression of chronic renal failure, however, is still not clear. Recent epidemiological studies point towards a contributive role of particular occupational exposures in the progression of renal disease. Furthermore, some observations in the 1994-1995 literature suggest a primary or secondary role, or both, of new substances such as silicon-containing compounds in the development of anti-neutrophil cytoplasmic antibody-positive rapidly progressive glomerulonephritis and Wegener's granulomatosis. Finally, studies suggesting a particular sensitivity of the diabetic kidney towards the damaging effects of certain occupational exposures deserve confirmation.

Humans↗

A simple technique for silicone rubber perfusion of the microcirculation of the mouse kidney.

A technique was described in which mouse kidneys were perfused with a silicone rubber compound. The technique involved cannulation of the left ventricle of the heart and subsequent perfusion of the entire systemic circulation of the mouse. Constant pressure was maintained to prevent distortion artifacts in the resultant renal microvascular cast. The method is adaptable to perfusion of other organs or animals.

Animals↗

Structure and composition of silicon-stabilized tricalcium phosphate.

Silicon stabilized tricalcium phosphate [Si-TCP] is formed within the calcium hydroxyapatite (HA)-tricalcium phosphate (TCP) system when a stoichiometric precipitate of hydroxyapatite is fired at 1,000 degrees in the presence of SiO(2). This paper proposes a composition range and crystallographic structure for Si-TCP. Reitveld XRD powder diffraction, transmission electron microscopy, infrared and proton nuclear magnetic resonance measurements show that crystalline Si-TCP is associated with the displacement of OH from an initial hydroxyapatite structure. The resulting calcium phosphate is modified by the incorporation of silicon into its structure with excess silica contributing to an amorphous component. Si-TCP has a monoclinic structure with a space group P2(1)/a akin to alpha-TCP with estimated lattice constants of a=12.863+/-0.004 A, b=9.119 +/-0.003 A, c=15.232+/-0.004 A, beta=126.3+/-0.1 degrees. It is proposed that Si(4+) substitutes for P(5+)in the TCP lattice with the average chemical composition of Si-TCP set primarily by the mechanisms available for charge compensation. While the formation of OH vacancies in HA initiates the transformation to Si-TCP, two mechanisms of charge compensation in the Si-TCP structure are plausible. If O(2-) vacancies provide charge compensation, the composition of Si-TCP is Ca(3)(P(0.9)Si(0.1)O(3.95))(2) derived for the addition of 0.33 mol SiO(2):mol HA. If excess Ca(2+) compensates, the composition is Ca(3.08)(P(0.92)Si(0.08)O(4))(2) derived for the addition of 0.25 mol SiO(2):mol HA. The reaction occurs most effectively when SiO(2) is added as a colloidal suspension rather than by the in-situ thermal decomposition of a silicon metallorganic compound. The material is a bioceramic of major biological interest because of its osteoconductivity and unique influence on skeletal tissue repair and remodeling.

Absorption↗

Photoreduction of silicomolybdate in chloroplasts by agents accelerating the deactivation reactions of the water-oxidizing system.

Uncouplers of photosynthetic phosphorylation, CCCP, TTFB and PCP, inhibited light-induced O2 evolution in the Hill reaction with SiMo (I50 approximately 20, 3 and 45 microM, respectively), but only insignificantly diminished SiMo photoreduction by pea chloroplasts. The same properties were exhibited by the ADRY agent ANT2p. CCCP, TTFB and PCP are oxidizable compounds with redox potentials of +1.17, +1.18 and +1.09 V (pH 6.0), as determined by cyclic voltammetry. Similarly to NH2OH, the tested uncouplers can apparently serve as electron donors for photosystem II.

Chloroplasts↗

Silicon and matrix macromolecules: new research opportunities for old diseases from analysis of potential mechanisms of breast implant toxicity.

An understanding of the normal and essential integration of the element silicon in biosystems, as well as knowledge of its fundamental chemistry, are crucial to understanding its role in health and disease. Modern organosilicon chemistry, based in part on the artificial silicon-carbon bond, coincided with the emergence of the biomaterials and bioengineering fields fifty years ago, and was thought to be a fortunate coincidence according to conventional wisdom that high-molecular-weight polymeric siloxanes were chemically and biologically inert. These concepts have been challenged by reports of silicone migration and degradation following insertion of gel-filled breast implants, claims of a novel systemic illness appearing in many breast implant recipients, and investigations implicating varied and permeating immunotoxic mechanisms of disease causation by breast devices. The present study develops additional potential pathogenetic ideas based on alterations of cell biochemistry by silicon-containing compounds, and offers correlation of the patients' diverse clinical features with plausable disruption of basic biological processes. This in turn raises new questions concerning everyday environmental exposure, has broad implications for multiple other diseases, can provide alternative directions for future investigative research, and may contribute to the ongoing redefinition of immune dysfunction and inflammation.

Biocompatible Materials↗

[Flotation and extraction spectrophotometric determination of trace silicate in water].

In HCl solution, silicate reacted with molybdate ammonium to produce silicomolibdic, then a yellow compound which was produced from the oxidation of TMB was simultaneously isolated to benzene phase by flotation and then isolated to dimethylsulfoxideformic acid by extraction. The compound gives a high absorption at 458 nm. The apparent molar absorptivity is 1.26 x 10(5) L.mol-1.cm-1. In the range of 0.02-1 mg.L-1 Si obeys Beer's law. The proposed method which combines with enrichment and measurement is simple, rapid, selective and convenient to determine silicate in water with satisfied results.

Benzidines↗

Development of collateral circulation following distal embolization of hepatic artery in pigs.

The distal hepatic artery was embolized with black polystyrene microspheres (diameters of 50 +/- 10 mu and 200 +/- 25 mu) in 12 pigs. The animals were reexamined from 1 h to 2 weeks after embolization via hepatic angiography and subsequent injection of Microfil, a silicone rubber compound, into the arterial and portal vascular systems of the liver. Dissection of dehydrated and cleared liver specimens under the stereomicroscope demonstrated the presence of arterial collaterals bypassing embolized vessels within 2-3 days after embolization. Collaterals were noted to develop around occlusions in arteries with inner diameters as small as 100 mu.

Angiography↗

Probing the structure of the silylene complex (Cy3P)2Pt=SiMes2.; UV-Vis and pre-resonance Raman investigations.

The UV-Vis, pre-resonance Raman and IR spectra of the complex (Cy3P)2Pt=SiMes2 (1) were obtained as well as Raman spectra of some model compounds. The experimental data and the results of normal coordinate calculations show that the stretching vibration of the Si?Pt bond in 1 is not localized, the nuSi=Pt internal coordinate makes significant contribution to two normal modes with frequencies at 465 and 612cm-1, whose Raman intensity is enhanced by pre-resonance.

Carbon↗

AFM characterization of solid-supported lipid multilayers prepared by spin-coating.

Lipids are the principal components of biologically relevant structures as cellular membranes. They have been the subject of many studies due to their biological relevance and their potential applications. Different techniques, such as Langmuir-Blodgett and vesicle-fusion deposition, are available to deposit ordered lipid films on etched surfaces. Recently, a new technique of lipid film deposition has been proposed in which stacks of a small and well-controlled number of bilayers are prepared on a suitable substrate using a spin-coater. We studied the morphological properties of multi-layers made of cationic and neutral lipids (DOTAP and DOPC) and mixtures of them using dynamic mode atomic force microscopy (AFM). After adapting and optimizing, the spin-coating technique to deposit lipids on a chemically etched Silicon (1,0,0) substrate, a morphological nanometer-scale characterization of the aforementioned samples has been provided. The AFM study showed that an initial layer of ordered vesicles is formed and, afterward, depending on details of the spin-coating preparation protocol and to the dimension of the silicon substrate, vesicle fusion and structural rearrangements of the lipid layers may occur. The present data disclose the possibility to control the lipid's structures by acting on spin-coating parameters with promising perspectives for novel applications of lipid films.

Biophysical Phenomena↗

Analysis of periprosthetic capsular tissue from women with silicone breast implants by magic-angle spinning NMR.

The amount of silicone (polydimethylsiloxane [PDMS]) in capsular tissue surgically removed from women with breast implants was measured by using (29)Si and (1)H magic-angle spinning solid-state NMR spectroscopy. Twelve women having smooth surface silicone gel-filled implants, including a subject with "low-bleed" double-lumen implants, had detectable levels of PDMS ranging from 0. 05 to 9.8% silicon in wet tissue (w/w). No silicon-containing compounds other than PDMS were detected. No correlation was found between the amount of PDMS measured in the capsular tissue and the length of implantation time (Pearson correlation coefficient, r = 0. 22). The results showed no relationship between higher amounts of PDMS and capsular contracture (p = 0.74) or other symptoms (p = 0. 53). Magn Reson Med 42:436-441, 1999.

Breast↗

Fallopian tube occlusion with silicone: radiographic appearance.

A new method of tubal occlusion for sterilization, which is both promising and potentially reversible, is undergoing clinical trials nationwide. At hysteroscopy, a catalyzed silicone rubber compound is instilled in the fallopian tubes where it hardens to form a radiopaque plug. Radiologists may assist the gynecologist in confirming adequate initial formation of the plug and with follow-up radiographs. Radiologists not involved in the procedure may see the radiopaque plugs on radiographs obtained for other clinical purposes, and they should be aware of this new method of sterilization.

Female↗

Quantitative cell culture biocompatibility testing of medical devices and correlation to animal tests.

The biocompatibility of a wide variety of biomaterials was quantitatively assessed, in a physiologically normal environment" as to cytotoxicity induced in WI-38 cells by cell culture medium extracts. Materials tested included PVC plastic, rubber, silicone rubber, polyethylene, polypropylene, acetal, polyurethane, Teflon, nylon, epoxy, and polystyrene. Cell culture test results were correlated to U.S.P. animal tests. Potential test artifacts, lead, barium, cadmium, and endotoxin were tested for cytotoxicity in WI-38 cells. Cell culture methods yielded more positive tests, particularly rubber, PVC plastic and silicone rubber compounds, than observed in U.S.P. animal tests. Positivity in animal tests did not correlate quantitatively to cytotoxic titers in cell culture. Discrepancies between cell cultures tests and animal tests, specifically rubber compounds, were attributable, in some instances, to differentials in elution efficiency between saline, cottonseed oil, and complete MEM cell culture medium. In other instances, particularly PVC plastics, differences between cell culture and animal test results were due to an inherent difference in the two indicator systems to respond to specific toxic moieties.

Acetals↗