Analysis of free fatty acids in whey products by solid-phase microextraction.

To evaluate the impact of Cheddar cheese starter cultures on the level of free fatty acids in liquid whey, a solid-phase microextraction (SPME) technique was utilized. The determination of response factors relative to an internal standard and the verification of linearity over a wide concentration range allowed for the quantitation of free fatty acids in experimentally produced liquid whey and in a wide range of dry whey ingredients. Results indicated that whey produced with a Lactococcus lactis subsp. lactis starter culture contained the highest level of total free fatty acids with significantly higher levels of lauric, myristic, and palmitic acids. Significant declines in oleic, linoleic, and palmitic acid occurred during storage. Commercial whey ingredients demonstrated a linear increase in free fatty acids with increasing percent protein, except for whey protein isolate, which had the lowest concentration. The use of SPME for the rapid analysis of free fatty acids in whey products should allow for further research to determine the importance of these compounds on the quality and stability of whey products.

Cheese↗

Ballpoint pen inks: the quantitative analysis of ink solvents on paper by solid-phase microextraction.

We wish to describe further developments to a method previously reported on the detection of 2-phenoxyethanol in ink. The solid-phase microextraction (SPME) sampling technique, together with gas chromatography-mass spectrometry (GC-MS), has been used to quantify solvents in writing ink. In conventional approaches, the analysis of ink on documents requires some degree of destructive sampling. The methods commonly used remove ink samples from paper using a scalpel or a paper punch. To avoid document destruction, a sampling cell was constructed that allows solvents to be adsorbed directly onto the SPME fiber from the headspace above the document surface. Analytes (ink volatiles) are then desorbed from the SPME fiber on a gas chromatograph equipped with a mass selective detector (GC-MSD). With this method, it was possible to detect the presence of ink solvents on documents for a period lasting up to c. 2 years.

Journal Article↗

Comparison of solid-phase microextraction, supercritical fluid extraction, steam distillation, and solvent extraction techniques for analysis of volatile consituents in Fructus Amomi.

Four sampling techniques, solid-phase microextraction (SPME), supercritical fluid extraction (SFE), steam distillation (SD), and solvent extraction (SE), were compared for the analysis of volatile constituents from a traditional Chinese medicine (TCM) of the dried ripe fruit of Fructus Amomi (Sha Ren). A total of 38 compounds were identified by gas chromatography/mass spectrometry. Different SFE and SPME parameters (modifier content, extraction pressure, and temperature for SFE and fibers, extraction temperature, and time for SPME) were studied. The results by SFE and SPME were compared with those obtained by conventional SD and SE methods. The results showed that SFE and SPME are better sample preparation techniques than SD and SE. Due to SFE's requirement for expensive specialized instrumentation, the simplicity, low cost, and speed of SPME make it a more appropriate technique for extraction of volatile constituents in TCMs.

Amomum↗

Monitoring volatile compounds during dry-cured ham ripening by solid-phase microextraction coupled to a new direct-extraction device.

Key flavour volatile compounds were monitored during ripening of dry-cured ham by solid-phase microextraction (SPME) coupled to a new direct-extraction device (DED). DED allows the insertion of the SPME fibre into the core of solid materials with no damage to the fibre. This enables extraction of volatiles from solid foodstuffs while avoiding sample handling. Major groups of volatile compounds extracted with SPME-DED agreed with available scientific literature about dry-cured ham volatiles. Moreover, volatile compounds previously highlighted as quality markers in dry-cured ham, such as 3-methylbutanal or hexanal, were satisfactorily extracted using SPME-DED. Changes in the profile of volatile compounds throughout the processing followed a typical pattern of volatile compounds formation. Therefore, SPME-DED appears as a new and promising method for monitoring ripening of dry-cured hams with no depreciation of the product, which might substitute traditional subjective methods currently used in the ham processing industry. However, the use of the internal standard method is not possible with this technique. Therefore, results using SPME-DED only point out a trend in the volatile profile. Further attempts relating data obtained using SPME-DED in dry-cured hams with sensory and chemical data from the same samples would be necessary for optimising this method as a quality control method in dry-cured ham industries.

Animals↗

Development of a solid-phase microextraction method for the determination of short-ethoxy-chain nonylphenols and their brominated analogs in raw and treated water.

A direct solid-phase microextraction (SPME) procedure has been developed and applied for the simultaneous determination of nonylphenol, nonylphenol mono- and diethoxylates and their brominated derivatives in raw and treated water at low microg l(-1) concentrations. Several parameters affecting the SPME procedure, such as extraction mode (headspace or direct-SPME), selection of the SPME coating, extraction time, addition of organic modifiers such as methanol and temperature were optimized. The divinylbenzene-carboxen-polydimethylsiloxane fiber was the most appropriate one for the determination of nonylphenol ethoxylates (NPEOs) and bromononylphenol ethoxylates (BrNPEOs) by SPME-GC-MS. The optimized method was linear over the range studied (0.11-2.5 microg l(-1)) and showed good precision, with RSD values between 4 and 15% and detection limits ranging from 30 to 150 ng l(-1) depending on the compound. The SPME procedure was compared with a solid-phase extraction-GC-MS method (C18 cartridge) for the analysis of NPEO and BrNPEOs in water samples. There was good agreement between the results from both methods but the SPME procedure showed some advantages such as lower detection limits, a shorter analysis time and the avoidance of organic solvents. The optimized SPME method was applied to determine nonylphenol and brominated metabolites in raw and treated water of Barcelona (NE Spain).

Bromine↗

Determination of cocaine and cocaethylene in urine by solid-phase microextraction and gas chromatography-mass spectrometry.

In order to evaluate recent cocaine exposure or its coingestion with ethanol, a simple and sensitive solid-phase microextraction (SPME) procedure for determination of cocaine and cocaethylene in urine was developed and validated. A polydimethylsiloxane fibre (100 microm) was submersed in the urine sample for 20 min under magnetic stirring after alkalinization with solid buffer (NaHCO(3):K(2)CO(3), 2:1). Gas chromatography-mass spectrometry (GC-MS) was used to identify and quantify the analytes in selected ion monitoring mode (SIM). The limits of quantification were 5.0 ng/mL for both analytes. Good inter- and intra-assay precision was also observed (coefficient of variation <9%).

Cocaine↗

Poly(methacrylic acid-ethylene glycol dimethacrylate) monolith in-tube solid-phase microextraction applied to simultaneous analysis of some amphetamine derivatives in urine by capillary zone electrophoresis.

A method based on in-tube solid-phase microextraction and capillary zone electrophoresis (CZE) was proposed for simultaneously determining four amphetamines (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in urine. A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column, which can provide sufficient extraction efficiency, was introduced for the extraction of amphetamines from urine samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the samples were analyzed by CZE. The best separation was achieved using a buffer composed of 0.1 M disodium hydrogen phosphate (adjusted to pH 4.5 with 1 M hydrochloric acid) and 20% methanol v/v, with a temperature and voltage of 25 degrees C and 20 kV, respectively. By applying electrokinetic injection with field-amplified sample stacking, detection limits of 25-34 microg/L were achieved. Excellent method of reproducibility was found over a linear range of 0.1-5 mg/L. Determination of these analytes from abusers' urine sample was also demonstrated.

Amphetamines↗

Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.

Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.

Fruit↗

Determination of 2,4,6-trichloroanisole and 2,4,6-tribromoanisole on ng L-1 to pgL-1 levels in wine by solid-phase microextraction and gas chromatography-high-resolution mass spectrometry.

A gas chromatography-high-resolution mass spectrometry (GC-HRMS) method using solid-phase microextraction (SPME) for the determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wine at low ng L(-1) levels was developed. A robust SPME method was developed by optimizing several different parameters, including type of fiber, salt addition, sample volume, extraction and desorption time. The quantification limit for TCA and TBA in wine was lowered substantially using GC-HRMS in combination with the optimized SPME method and allowed the detection of low analyte concentrations (ng L(-1)) with good accuracy. Limits of quantification for red wine of 0.3 ng L(-1) for TCA and 0.2 ng L(-1) for TBA with gas chromatography-negative chemical ionization mass spectrometry and 0.03 ng L(-1) for TCA and TBA were achieved using GC-HRMS. The method was applied to 30 wines of which 4 wines were sensorically qualified as cork defected. TCA was found in three of these wines with concentrations in the range 2-25 ng L(-1). TBA was not detected in any of the samples.

Anisoles↗

Simultaneous determination of barbiturates in human biological fluids by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry.

Simultaneous determination of seven barbiturates in human whole blood and urine by combining direct immersion solid-phase microextraction (DI-SPME) with gas chromatography-mass spectrometry (GC-MS) is presented. The main parameters affecting the DI-SPME process, such as SPME fibers, salt additives, pHs, extraction temperatures and immersion times were optimized for simultaneous determination of the drugs. The extraction efficiencies were 0.0180-0.988 and 0.0156-2.76% for whole blood and urine, respectively. The regression equations of the drugs showed excellent linearity for both samples; the correlation coefficients (r(2)) were 0.994-0.999. The detection limits for whole blood were 0.05-1 microg x ml(-1), and those for urine 0.01-0.6 microg x ml(-1). Actual quantitation could be made for pentobarbital in whole blood and urine obtained from volunteers, who had been orally administered a therapeutic dose of the drug. The DI-SPME/GC-MS procedure for barbiturates established in this study is simple and sensitive enough to be adopted in the fields of clinical and forensic toxicology.

Barbiturates↗

Single hair analysis of methamphetamine and amphetamine by solid phase microextraction coupled with in matrix derivatization.

A sensitive method for detection of methamphetamine (MA) and amphetamine (AP) in human hair was developed using solid phase microextraction (SPME) and one-pot derivatization. MA and AP were directly derivatized to N-propoxycarbonyl derivatives in an aqueous solution by propylchloroformate in a one-pot reaction before extraction by SPME. The derivatives were extracted to a coating of SPME from a headspace of the vial. The adsorbed derivatives were thermally desorbed in the injection port of a gas chromatograph. Pentadeuterated MA was used as an internal standard. The absolute recoveries of MA and AP from the spiked hair were 2.80-17.5%, respectively. The calibration curves showed linearity in the range of 0.05-20 ng/0.08 mg/vial for MA and 0.1-20 ng/0.08 mg/vial for AP in hair. Detection limits (S/N = 3) of MA and AP were 0.02 and 0.05 ng/0.08 mg/vial. The coefficients of variation of intraday were 1.04-26.4%. Additionally, this proposed method was applied to segmental analysis in clinical and medico-legal cases of MA intoxication.

Adult↗

Selective stationary phase for solid-phase microextraction analysis of sarin (GB).

A number of critical field applications require monitoring air samples for trace levels of chemical warfare agents. Solid-phase microextraction (SPME) is a convenient format to conduct these analyses. Measurements could be significantly improved if a SPME phase selective for nerve agents were substituted for non-selective polymers typically used (e.g., polydimethylsiloxane). This paper evaluates a novel stationary phase, previously developed for methylphosphonate sensor applications, for use with SPME sampling. The phenol-based polymer, BSP3, was found to offer far higher selectivity toward sarin (GB) than polydimethylsiloxane due to a pronounced affinity toward the target analyte and a lower affinity toward hydrocarbons.

Air↗

Inter-laboratory validation of solid-phase microextraction for the determination of triazine herbicides and their degradation products at ng/l level in water samples.

The accuracy and precision of solid-phase microextraction (SPME) were validated in an inter-laboratory study including ten laboratories for the analysis of triazine herbicides and their metabolites at ng/l level in aqueous samples. The SPME conditions were optimised in order to obtain maximum sensitivity. Especially, salt addition and choice of the SPME fibre coated with Carbowax-divinylbenzene increased the sensitivity. The average detection limits were in the range from 4 to 24 ng/l for the triazine herbicides, and 20 and 40 ng/l for desisopropylatrazine and desethylatrazine, respectively. The average r2 values of the calibration curves were above 0.99 for all of the analytes. The statistical data treatment was performed in accordance with the International Standardisation Organisation (ISO) standard 5725. Relative repeatability standard deviations between 6 and 14% and relative reproducibility standard deviations between 10 and 17% were found. The determined concentrations of the reference sample compared well to the "true" values, thus proving the good accuracy of the method. It is concluded that SPME is a reliable technique for the quantitative analysis of water samples containing triazine herbicides in concentrations around the European limit of 100 ng/l for individual pesticides in drinking water.

Calibration↗

Solid-phase microextraction with pH adjustment for the determination of aromatic acids and bases in water.

Adjusting the pH of water samples before performing solid-phase microextraction (SPME) analysis can be used to selectively extract organic acids (at pH 2) and bases (at pH 12). Sorption behavior of test organics is predictable based on the acid dissociation constant in water. In general, polyacrylate (PA) and Carbowax-divinylbenzene (CW-DVB) show substantially higher fiber/water sorption coefficients (Kd values) than a polydimethylsiloxane (PDMS) coated fiber. Gas chromatography-flame ionization detection (GC-FID) detection limits with the CW-DVB sorbent are approximately 0.5 to 10 ng/ml in a 2-ml water sample for a variety of aromatic amines, phenols, and chlorinated phenols, and are approximately 1 to 50 ng/ml for the same solutes using the PA sorbent. However, the PA fiber is more selective (depending on the water pH) for the acid or base components than the CW-DVB fiber. With proper pH adjustment, the recovery of spiked aromatic amines and phenols from a surface wetlands water ranged from 73 to 118% of the known values, with a precision (R.S.D.) of approximately 5 to 20%. SPME quantitation of phenols in a coal gasification wastewater using a PA fiber also gave excellent agreement with conventional methylene chloride extraction, although continued use of a single fiber with this wastewater led to poorer precision.

Acids↗

Solid-phase microextraction applied to the analysis of pesticide residues in honey using gas chromatography with electron-capture detection.

The possibilities of using solid-phase microextraction to determine residues of pesticides in honey have been examined. For this purpose, three types of fiber have been assayed: polyacrylate of 85 microns thickness, and polydimethylsiloxane of 7 and 100 microns thickness. They have been applied to the extraction of 21 pesticides of different chemical families. The effects of the temperature, extraction time and ionic strength on the microextraction have been studied, proposing the most adequate for each fiber. Under optimized conditions, precision, intervals of linearity and detection limits were evaluated.

Chromatography, Gas↗

Solid-phase microextraction with capillary gas-liquid chromatography and nitrogen-phosphorus selective detection for the assay of antidepressant drugs in human plasma.

Solid-phase microextraction (SPME) was tested as a sample preparation for the simultaneous assay of ten antidepressant drugs and metabolites (TADs) in human plasma. Aqueous NaOH (0.5 ml, 1 M) and chloramitriptyline (50 microliters, 40 micrograms/ml) as internal standard (I.S.) were added to a 2-ml plasma sample. This mixture was extracted with a 100-micron polydimethylsiloxane SPME fiber (Supelco) for 10 min. After washing in water and methanol (50%) and subsequent drying at room temperature, desorption of the fiber was performed in the injection port of a gas chromatograph at 260 degrees C for 1 min (HP 5890, DB-17 30 m x 0.25 mm I.D., 0.25 micron capillary; 0.7 ml/min nitrogen; nitrogen-phosphorus selective detection). The recovery was found to be very low from plasma (0.3% to 0.8%) but considerably higher from water (about 15%). Therefore, the high protein binding of antidepressants appears to be the main limiting mechanism for a better extraction. However, the analytes were well separated and the calibrations were linear between 125 ng/ml and 2000 ng/ml. The limits of quantification were about 90 ng/ml for imipramine and desipramine, 125 ng/ml for amitriptyline, trimipramine, doxepine, nortriptyline and mianserine and about 200 ng/ml for maprotiline, clomipramine and desmethylclomipramine. The recovery was improved by increasing the extraction time. The influence of the concentrations of the sum of proteins and of alpha-acid glycoprotein on the peak-area ratios ATAD/A I.S. and on absolute peak areas was studied. Peak-area ratios increased with decreasing protein concentration but were found to be independent on alpha-acid glycoprotein. A simple model for the explanation of the effect is presented. Measures for the improvement of sensitivity are discussed. As presented in this paper, which first describes SPME for the analysis of drugs in plasma, SPME with a short extraction time can be of only very limited value for therapeutic drug monitoring. Lower concentrations than the limit of quantification are usually found at therapeutic doses. The method can be useful for toxicological analysis after the accidental or suicidal intake of higher doses. However, an about 10-fold improvement of the sensitivity of the method seems to be possible.

Antidepressive Agents↗

Improved extraction of thinner components from human body fluids by headspace solid-phase microextraction with a Carboxen/polydimethylsiloxane-coated fiber.

An improved method for extraction of thinner components in human whole blood and urine samples by headspace solid-phase microextraction (SPME) with a Carboxen/polydimethylsiloxane-coated fiber is presented. The body fluid samples, containing ethyl acetate, benzene, 1-butanol, toluene, butyl acetate, isoamyl acetate and ethylbenzene as internal standard (IS), were heated at 70 degrees C in a silicone-rubber septum-capped vial in the presence of distilled water plus NaCl; a Carboxen/polydimethylsiloxane-coated SPME fiber was then exposed to the headspace of the vial to allow adsorption of the compounds before capillary gas chromatography (GC) with flame-ionization detection. For whole blood, extraction efficiencies of 1-butanol, ethyl acetate and isoamyl acetate were 8.72-31.1%, and those of IS, butyl acetate, toluene and benzene were 42.9-74.1%. For urine, those of all compounds were 10.7-75.4%. The regression equations for six thinner components extracted from whole blood and urine were linear in the range of 3-500 ng/0.5 ml for ethyl acetate and 1-butanol, and 0.5-500 ng/0.5 ml for benzene, toluene, butyl acetate and isoamyl acetate. The detection limits for each of the components were 0.25-1.5 ng/0.5 ml for both samples. The coefficients of within-day and day-to-day variation for all components were satisfactory and not greater than 11 and 13%, respectively. The data obtained from actual determination of ethyl acetate, benzene and toluene in rat whole blood and urine after inhalation of the compounds were also presented.

Journal Article↗

In-tube moleculary imprinted polymer solid-phase microextraction for the selective determination of propranolol.

A molecularly imprinted polymer (MIP) material was synthesized for use as an in-tube solid-phase microextraction (SPME) adsorbent. The inherent selectivity and chemical and physical robustness of the MIP material was demonstrated as an effective stationary-phase material for in-tube SPME. An automated and on-line MIP SPME extraction method was developed for propranolol determination in biological fluids. This simplified the sample preparation process and the chromatographic separation of several beta-blocker compounds. The method developed for propranolol showed improved selectivity in comparison to alternative in-tube stationary-phase materials, overcoming the limitations of existing SPME coating materials. Preconcentration of the sample by the MIP adsorbent increased the sensitivity, yielding a limit of detection of 0.32 microg/mL by UV detection. Excellent method reproducibility (RSD < 5.0%) and column reusability (> 500 injections) were observed over a fairly wide linear dynamic range (0.5-100 microg/mL) in serum samples. To our knowledge, this is the first report on the automated application of a MIP material for in-tube SPME. The method was inexpensive, simple to set up, and simplified the choice of SPME adsorbent for in-tube extraction. The approach can potentially be extended to other MIPs for the determination of a wide range of chemically significant analytes.

Adrenergic beta-Antagonists↗