PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Telemetry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Determination of extracellular pH and tissue temperature in transplantable rat tumors by use of inductive loop telemetry.

Radiotelemetry was used to determine changes in extracellular pH and tissue temperature during tumor development in rats of an inbred WAB substrain. A progressive decrease in the pH of the tumor tissue compared with the pH level in control tissue was observed, so that by 4 days after tumor implantation the tumor tissue was about 0.4 pH units lower than control values. Thereafter, tumor pH rose progressively to reach a value comparable with control levels at 8 days, when the experiment was terminated. No significant difference was detected between the temperature in the tumor tissue and the temperature in the control tissue. Therefore, the observed changes in pH appeared to be independent of temperature. Studies on the rate of tumor cell proliferation during the experiments demonstrated a significant inverse relationship between tumor cell mitotic rate and pH, with the highest rates of cell proliferation occurring at the time of lowest pH values.

Animals↗

Telemetry beyond the ICU.

A Texas hospital uses telemetric oxygenation monitoring on medical/surgical floors to decrease critical care admissions for patients at risk of respiratory compromise.

Computers, Handheld↗

Integrated technologies transform telemetry.

Current monitoring and alarm notification technologies can help merge biomedical, information, and telecommunication systems into completely new configurations.

Cardiovascular Diseases↗

Comparison of data obtained from sedated versus unsedated wireless telemetry capsule placement: does sedation affect the results of ambulatory 48-hour pH testing?

OBJECTIVES: The introduction of 48-hour wireless pH testing provides a novel technique of evaluating persons with suspected reflux disease. The wireless capsule can be placed in a sedated individual at the time of esophagogastroduodenoscopy (EGD) or in an unsedated individual at a time after the initial EGD, at the time of esophageal manometry or at the time of transnasal esophagoscopy. The effect that sedation has on the results of 48-hour wireless pH testing has not been evaluated. PURPOSE: To evaluate the day to day variability and the effect of sedation on the results of 48-hour wireless pH testing. METHODOLOGY: The charts of all patients at a tertiary swallowing center undergoing 48-hour wireless pH testing between June 1, 2003 and December 31, 2004 were retrospectively evaluated. Data concerning study indications, route of pH capsule placement, duration of pH recording, and test results were collected. Day to day variability was evaluated, and the results obtained from persons with sedated and unsedated pH capsule placement were compared. RESULTS: Two hundred and six studies were performed. The indications for the examination were gastroesophageal reflux disease (146/206), chronic cough (36/206), and laryngopharyngeal reflux (24/206). Sixty-two percent (128/206) of the studies were performed without sedation and 38% (78/206) with sedation. The overall reproducibility of the daily pH recordings (day 1 vs. day 2) was 77%. Although some trends were observed, there was no significant association between the use of sedation and any of the reflux parameters on pH testing (P > .05). CONCLUSIONS: The day to day reproducibility of 48-hour wireless pH testing was 77%. Intravenous sedation does not appear to have a significant effect on the results of 48-hour wireless pH testing.

Capsules↗

The navigational feats of green sea turtles migrating from Ascension Island investigated by satellite telemetry.

Previous tagging studies of the movements of green turtles (Chelonia mydas) nesting at Ascension Island have shown that they shuttle between this remote target in the Atlantic Ocean and their feeding grounds on the Brazilian coast, a distance of 2300 km or more. Since a knowledge of sea turtle migration routes might allow inferences on the still unknown navigational mechanisms of marine animals, we tracked the postnesting migration of six green turtle females from Ascension Island to Brazil. Five of them reached the proximity of the easternmost stretch of the Brazilian coast, covering 1777-2342 km in 33-47 days. Their courses were impressively similar for the first 1000 km, with three turtles tracked over different dates following indistinguishable paths for the first 300 km. Only the sixth turtle made some relatively short trips in different directions around Ascension. The tracks show that turtles (i) are able to maintain straight courses over long distances in the open sea; (ii) may perform exploratory movements in different directions; (iii) appropriately correct their course during the journey according to external information; and (iv) initially keep the same direction as the west-south-westerly flowing current, possibly guided by chemical cues.

Animals↗

A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors.

An implantable potentiostat-radiotelemetry system for in vivo sensing of glucose is described. An enzyme electrode sensor measures the oxidation current of hydrogen peroxide formed by the stoichiometric conversion of glucose substrate and oxygen cofactor in an immobilized glucose oxidase layer. The sensor current is converted to a frequency and transmitted at programmable intervals (4, 32, 256 s) to a remote receiver. Low power CMOS circuitry is employed and device operation for up to 1.5 years is predicted using two series connected 250 mAh lithium cells. Crystal controlled RF frequencies uniquely identify each sensor allowing over 10 sensors within the same 10 m radius. A custom interface card allows a PC to program the receiver and handle the transmitted sensor data using software written in Microsoft C and QuickBasic. Software control allows on-the-fly sensor addition or subtraction to the sensor group being monitored. Over 10 sensors can be tracked long-term using the longest transmit interval, or four sensors can be tracked during short-term infusion studies when the transmit interval is reduced to 4 s. The design, construction, operation, and performance of the system hardware and software are described and evaluated.

Animals↗