Polymerization rate and mechanism of ultrasonically initiated emulsion polymerization of n-butyl acrylate.

The factors affecting the induction period and polymerization rate in ultrasonically initiated emulsion polymerization of n-butyl acrylate (BA) were investigated. The induction period takes only an instant in ultrasonically initiated emulsion polymerization of BA without any added initiator by enhancing the N2 flow rate. Increasing temperature, power output and SDS concentration, decreasing the monomer concentration results in further decreasing induction period and enhanced polymerization rate. Under optimized reaction conditions the conversion of BA reaches 92% in 11 min. The polymerization rate can be controlled by varying reaction parameters. The apparatus of ultrasonically initiated semi-continuous and continuous emulsion polymerization were set up and the feasibility was first studied. Based on the experimental results, a free radical polymerization mechanism for ultrasonically initiated emulsion polymerization was proposed, including the sources of the radicals, the process of radical formation, the locus of polymerization and the polymerization process. Compared with conventional emulsion polymerization, where the radicals come from thermal decomposition of a chemical initiator, ultrasonically initiated emulsion polymerization has attractive features such as no need for a chemical initiator, lower reaction temperature, faster polymerization rate, and higher molecular weight of the polymer prepared.

Journal Article↗

Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure.

The present study was designed to evaluate the relationships between ultrasonic backscatter, density, and microarchitecture of cancellous bone. The slopes of the frequency-dependent attenuation coefficient (nBUA), ultrasound bone velocity (UBV), the frequency-averaged backscatter coefficient (BUB) were measured in 25 cylindrical cancellous bone cores. Bone mineral density (BMD) was determined using X-ray quantitative computed tomography. Microarchitecture was investigated with synchrotron radiation microtomography with an isotropic spatial resolution of 10 microm. Several microstructural parameters reflecting morphology, connectivity, and anisotropy of the specimens were derived from the reconstructed three-dimensional (3D) microarchitecture. The association of the ultrasonic variables with density and microarchitecture was assessed using simple and multivariate linear regression techniques. For all ultrasonic variables, a strong association was found with density (r = 0.84-0.90). We also found that, with the exception of connectivity, all microstructural parameters correlated significantly with density, with r values of 0.54-0.92. For most microstructural parameters there was a highly significant correlation with ultrasonic parameters (r = 0.33-0.91). However, the additional variance explained by microstructural parameters compared with the variance explained by BMD alone was small (Delta r(2) = 6% at best). In particular, no significant independent association was found between microstructure and backscatter coefficient (a microstructure-related ultrasonic parameter) after adjustment for density. The source for the unaccounted variance of quantitative ultrasound (QUS) parameters remains unknown.

Aged↗

Effect of ultrasonic agitation on the release of copper, iron, manganese and zinc from soil and sediment using the BCR three-stage sequential extraction.

An ultrasonic bath and an ultrasonic probe have been used to develop rapid versions of the three-stage Community Bureau of Reference (BCR, now the Standards, Measurement and Testing Programme) sequential extraction procedure. The effect of the ultrasonic treatments on the extraction of copper, iron, manganese and zinc from a sewage sludge-amended soil has been assessed. Recoveries similar to those of conventional shaking (i.e., conventional value, +/- 30%) could generally be obtained for copper, manganese and zinc, but not for the important matrix element iron. With the use of compromise sonication conditions, steps 1, 2 and 3 of the sequential extraction (excluding the hydrogen peroxide digestion in step 3, which was not performed with sonication) could be completed in 3, 5 and 1 min, respectively, using the ultrasonic probe, and in 3, 1 and 1 h, respectively, using the bath. The extraction procedures developed using the soil performed well when applied to lake sediment BCR CRM 601. Analyte partitioning was generally similar to that obtained with mechanical shaking, and overall metal recoveries were 84-98% of those obtained with the conventional BCR protocol, except for copper extracted with the probe (74%). Poorer performance (analyte recoveries, 58-104%) was obtained when the methods were applied to an intertidal sediment. This highlights the difficulty of developing a version of the BCR extraction, with ultrasonic assistance, which gives a performance equivalent to conventional shaking when applied to different substrates.

Copper↗

A new miniature ultrasonic probe for gastrointestinal scanning: feasibility and preliminary results.

A prototype of a new miniature ultrasonic probe (Aloka) was clinically evaluated in 37 patients with a variety of gastrointestinal lesions. The probe's diameter of 2.0 mm allowed passage through the working channel of conventional endoscopes; the ultrasonic frequencies used were 15 and 20 MHz. Fourteen patients with benign and malignant gastrointestinal tumors, and thirteen patients with a variety of benign conditions, were examined, 12 of whom also underwent conventional endoscopic ultrasonography with side-viewing echoendoscopes. The image quality of the two systems was well comparable, but the ultrasonic penetration depth of the miniprobes was inferior to that of conventional endoscopic ultrasonography (EUS). All but three lesions were adequately visualized by the ultrasonic probe, whereas conventional EUS failed to completely visualize four cases. Of the two ultrasonic frequencies used, we found 15 MHz to be superior, since it provided good image quality and adequate penetration depth. In conclusion, we feel that the probe can be used for EUS indications in the gastrointestinal tract, whereas further technical improvements, such as increasing the penetration depth, are necessary before pancreatobiliary EUS can be carried out.

Adult↗

Ultrasonic and radiographic cholecystography.

To define the relative merits of radiographic and ultrasonic cholecystography, we studied 208 randomly selected patients with possible cholelithiasis. The patients underwent both procedures, and the results were interpreted in blind fashion. Two hundred patients had satisfactory confirmation of their diagnosis, by either a well visualized radiographic cholecystogram or operation or both. The overall accuracy of the ultrasonic examination was 93 per cent, with a false-negative rate of 11 and an indeterminate rate of 4 per cent. The indeterminate rate was 24 per cent for the single-dose oral cholecystogram and 8 per cent for the double-dose oral cholecystogram. Both ultrasonic cholecystography and radiographic cholecystography are useful to detect gallstones. Our findings support using single-dose oral cholecystography as the routine first examination. If the gallbladder is not satifactorily visualized, ultrasonic cholecystography can be performed immediately. In an emergency or for patients who might be pregnant, ultrasonic cholecystography is available as the initial examination.

Administration, Oral↗

Progress towards in vitro quantitative imaging of human femur using compound quantitative ultrasonic tomography.

The objective of this study is to make cross-sectional ultrasonic quantitative tomography of the diaphysis of long bones. Ultrasonic propagation in bones is affected by the severe mismatch between the acoustic properties of this biological solid and those of the surrounding soft medium, namely, the soft tissues in vivo or water in vitro. Bone imaging is then a nonlinear inverse-scattering problem. In this paper, we showed that in vitro quantitative images of sound velocities in a human femur cross section could be reconstructed by combining ultrasonic reflection tomography (URT), which provides images of the macroscopic structure of the bone, and ultrasonic transmission tomography (UTT), which provides quantitative images of the sound velocity. For the shape, we developed an image-processing tool to extract the external and internal boundaries and cortical thickness measurements. For velocity mapping, we used a wavelet analysis tool adapted to ultrasound, which allowed us to detect precisely the time of flight from the transmitted signals. A brief review of the ultrasonic tomography that we developed using correction algorithms of the wavepaths and compensation procedures are presented. Also shown are the first results of our analyses on models and specimens of long bone using our new iterative quantitative protocol.

Algorithms↗

Quantitative ultrasonic assessment of normal and ischaemic myocardium with an acoustic microscope: relationship to integrated backscatter.

PURPOSE OF INVESTIGATION: The aim was to study ultrasonic propagation properties of normal and ischaemic myocardium with a scanning laser acoustic microscope and to correlate these changes with ultrasonic backscatter. DESIGN: Myocardial ischaemia was produced by total occlusion of left anterior descending coronary artery in anaesthetised open chest dogs. Myocardium supplied by left circumflex coronary artery served as normal control. IBR5, an optimum weighted frequency average (4-6.8 MHz) of the squared envelope of diffraction corrected backscatter, was measured in vivo. Ultrasonic attenuation coefficient, an index of loss per unit distance, the propagation speed and heterogeneity index were measured from normal and ischaemic regions with a scanning laser acoustic microscope which operates at 100MHz in vitro. Myocardial water content of normal and ischaemic myocardium was also estimated. SUBJECTS: Were five anaesthetised mongrel dogs. RESULTS: Attenuation coefficient of 33.8(SD4.2) dB.mm-1 in the ischaemic tissue was lower than 63.8(17.2) dB.mm-1 in the normal tissue (p less than 0.01). Ultrasonic speed was lower in ischaemic than normal myocardium at 1584(25) v 1612(35) m.s-1 (p less than 0.05). Heterogeneity index of 11(7) m.s-1 in the ischaemic region was lower than 14(8) m.s-1 in the normal region (27% reduction, p less than 0.05). IBR5 and myocardial water content were higher in the ischaemic than the normal myocardium: -37.2(SEM1.8) dB v -46.6(0.6) dB, (p less than 0.01) and 80.9(0.0)% v 78(0.2)%, (p less than 0.05) respectively. CONCLUSION: Ultrasonic properties of the myocardium are significantly altered during acute ischaemia.

Animals↗

The diagnosis of pancreatic cyst by endoscopic retrograde pancreatography and ultrasonic scanning.

Fourteen patients with verified pancreatic cysts were examined by both preoperative endoscopic retrograde pancreatography (ERP) and ultrasonic scanning. ERP showed filling of a cyst in 4 patients and raised suspicion of a cyst in 8. In two patients it was not possible to visualize the pancreatic duct. Ultrasonic scanning showed a cyst in 12 patients. There were two false negative ultrasonic diagnoses. These two were correctly diagnosed by ERP. Ultrasonically guided percutaneous puncture was carried out on 19 occasions in 8 patients. Cysts down to 2 cm in diameter were punctured without difficulty. There were no clinically significant complications due to the punctures. One patient was followed for 20 months without ultrasonically demonstrable recurrence of a large cyst aspirated, showing that definite therapy is possible by this method. Puncture can be used to verify the diagnosis and as treatment in patients where surgery is contraindicated.

Diagnosis, Differential↗

Corneal indentation during ultrasonic pachometry.

PURPOSE: This study attempted to determine whether the indentation of the cornea with an ultrasonic probe affects the corneal-thickness measurement. METHODS: A solid-tip ultrasonic transducer was mounted into the spring arm of a standard Goldmann Applanation Tonometer. Five human subjects were studied. The visual axis of each cornea was marked with a corneal marker, and the ultrasonic transducer was placed on the visual axis. Corneal-thickness measurements were made during five tension settings of the tonometer: 0, 10, 20, 40, and 80. The R-F signals were received by using a 475 Textronix oscilloscope, and the thicknesses were digitally measured. RESULTS: There was no trend for decreasing or increasing thickness measurements with increasing tension settings. CONCLUSION: Corneal-thickness measurements by ultrasonic pachometry are not significantly affected by corneal indentation with the ultrasonic probe.

Anthropometry↗

Computerized ultrasonic digitization in the measurement of spinal curvature.

A major concern in school screening programs as well as in the clinical assessment of spinal curvature has been the frequent radiation exposure required to ascertain curve progression. Various techniques have been developed to identify scoliosis such as the Moire and ISIS techniques, but these are very sophisticated and expensive. The authors have developed a simple procedure of identifying and documenting spinal curvature during the performance of the Adams forward bend test, using an ultrasonic sound probe, four sound receivers, and a micro-computer. The probe is run along the spinous processes emitting an ultrasonic sound, which is picked up by four receivers mounted at the corners of a rectangle above the patient. The signal is fed into a micro-computer and the spinal curvature is plotted out. The magnitude of the curve is calculated by the computer, and the actual curve plus the magnitude is printed in hard copy to be placed in the chart. The reproducibility error and intermeasurer error has been less than 5%. A series of 30 patients with varying magnitudes of scoliosis from 15 degrees to 73 degrees were examined. The results of the ultrasonic digitization were compared with standard scoliosis radiographs of the patient taken the same week. The average curvature measured from the radiographs was 38 degrees, and from the ultrasonic digitization technique, 30 degrees: The forward bend position contributed to smaller curvature measurement, and measurement in the standing position was thought to be a better technique. Ultrasonic digitization as a method of curve measurement is most accurate in curves over 30 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)

Diagnosis, Computer-Assisted↗

Clinical efficacy of a combination pneumatic and ultrasonic lithotrite.

PURPOSE: A new combination pneumatic/ultrasonic intracorporeal lithotriptor has been developed for percutaneous applications. It combines the stone clearing efficiency of an ultrasonic device with the fragmentation strength of a pneumatic probe into a single handpiece. We present our early clinical experience with this device in a prospective, randomized comparison a combination pneumatic/ultrasound lithotrite and standard ultrasonic lithotripsy. MATERIALS AND METHODS: A total of 20 consecutive patients undergoing percutaneous nephrolithotomy for symptomatic calculi were randomized to receive stone fragmentation and removal using a standard ultrasonic device or a new combination pneumatic/ultrasonic unit. Stone location and burden were assessed before the operative procedure. The stone clearance rate in mm.2 per minute was calculated for the 2 devices. Complications and stone-free rates were compared in the 2 groups. RESULTS: There were no significant differences in stone location and composition in the 2 groups of patients. Average time required for complete stone clearance was considerably less for the combination device (21.1 versus 43.7 minutes, p = 0.036). The opposite was true for the average rate of stone clearance in mm.2 per minute, in that the standard ultrasonic device could clear 16.8 versus 39.5 mm.2 per minute for the combination unit (p = 0.028). Stone-free and complications rates were slightly superior for the combination device but it was likely attributable to patient factors. CONCLUSIONS: The combination pneumatic/ultrasonic lithotrite is capable of disintegrating and extracting stone material at a more rapid rate than standard ultrasonic devices. Moreover, stone-free and complication rates appear to be slightly superior with the combination unit. This new combination pneumatic/ultrasonic device appears to be efficacious and safe for removing large renal calculi.

Cohort Studies↗

In vitro assessment of ultrasonic lithotriptors.

PURPOSE: Ultrasonic lithotriptors are commonly used to fragment and remove stones during percutaneous nephrolithotomy. To date a comparative assessment of current units has not been accomplished without potential operator bias. An objective testing environment is required for optimal appraisal of the efficiency of ultrasonic lithotriptors. MATERIALS AND METHODS: An in vitro test system was devised to evaluate the ability of ultrasonic lithotriptors to core through artificial stones. The system consisted of an irrigation sheath (Cook Urological, Spencer, Indiana) through which ultrasonic probes were placed. Ultrasonic hand pieces and probes were secured in an upright position. An Ultracal-30 (U.S. Gypsum, Chicago, Illinois) stone cylinder (mean length 12.8 +/- 0.6 mm, mean diameter 7.6 +/- 0.07 mm) was centered on the probe tip. A weight (62.7 gm) was placed atop the stone to provide a constant force. We evaluated the Olympus LUS-1 and LUS-2 (Olympus, Melville, New York), Circon-ACMI USL-2000 (Circon-ACMI, Southborough, Massachusetts), Karl Storz Calcuson (Karl Storz, Culver City, California) and Richard Wolf model 2271.004 (Richard Wolf, Vernon Hills, Illinois). All probes had outer diameters of 3.4 mm except for the Circon-ACMI unit (3.8 mm). Using 100% power settings times for complete stone penetration were assessed for all units. Differences in mean stone penetration times were compared using ANOVA. RESULTS: The Olympus LUS-2 had the fastest mean stone penetration time (28.8 +/- 2.7 seconds). This value was used to normalize the data into efficiency ratios, where other unit times were expressed as multiples of the LUS-2 time: Olympus LUS-2 (1.0 +/- 0.1) equals Circon-ACMI USL-2000 (1.1 +/- 0.3) greater than Karl Storz Calcuson (1.4 +/- 0.3) greater than Olympus LUS-1 (2.1 +/- 0.5) greater than Richard Wolf (3.6 +/- 0.8). Efficiencies of the LUS-2 and USL-2000 units were essentially equivalent, with all others significantly less efficient (p <0.05). CONCLUSIONS: This new in vitro testing model provides an objective, reproducible method for evaluating the efficiency of intracorporeal lithotriptors. Of the units tested the Olympus LUS-2 and Circon-ACMI USL-2000 were the most efficient.

Equipment Design↗

A novel multi-degree-of-freedom thick-film ultrasonic motor.

This paper describes a new multi-degree-of-freedom (MDOF) ultrasonic motor that comprises few parts and is based on low-cost thick-film technology. Conventional ultrasonic motors using bulk lead zirconate titanate (PZT) or thin-film PZT layers are relatively expensive at the present time. Thick-film printed PZT technology provides the opportunity to reduce the costs of ultrasonic motors. To demonstrate the feasibility of this approach, an ultrasonic motor was fabricated from alumina using thick-film printed PZT actuators. The thick-film PZT and electrode layers were printed on a thin alumina plate, and a tiny cylinder was mounted at its center. This cylinder magnifies the lateral displacement of the stator, holds the spherical rotor, and transmits the driving force to the sphere. Three bending vibrations, B22, B30, B03, of the plate were applied to rotate the sphere. Sufficient displacements for rotating the sphere were obtained near the resonance of B22 by applying an excitation voltage of 200 V peak-to-peak via a three-phase drive circuit. Rotations in three orthogonal directions have been observed by controlling the phase of the driving signal to the PZT electrodes, and a MDOF ultrasonic motor was successfully realized.

Journal Article↗

Noncontact detection of ultrasonic waves using fiber optic Sagnac interferometer.

This paper describes a fiber optic sensor suitable for noncontact detection of ultrasonic waves. This sensor is based on the fiber optic Sagnac interferometer, which has a path-matched configuration and does not require active stabilization. Quadrature phase bias between two interfering laser beams in the Sagnac loop is applied by controlling the birefringence using a fiber polarization controller. A stable quadrature phase bias can be confirmed by observing the interferometer output according to the change of phase bias. Additional signal processing is not needed for the detection of ultrasonic waves using the Sagnac interferometer. Ultrasonic oscillations produced by conventional ultrasonic piezoelectric transducers were successfully detected, and the performance of this interferometer was investigated by a power spectrum analysis of the output signal. Based on the validation of the fiber optic Sagnac interferometer, noncontact detection of laser-generated surface waves was performed. The configured Sagnac interferometer is very effective for the detection of small displacement with high frequency, such as ultrasonic waves used in conventional nondestructive testing (NDT).

Journal Article↗

Propagation of ultrasonic waves through demineralized cancellous bone.

Ultrasonic velocity is determined in a number of bovine cancellous (spongy) bone samples by using a double-probe-through-transmission ultrasonic pulse technique. The ultrasonic velocity, total mineral content, bone density, and solid volume fraction of the specimen were determined. The relation between fast velocity and each of the other parameters was examined to explore the best correlation using linear, logarithmic, power, and exponential relationships. There is a strong positive relationship between ultrasonic velocity and each of the other parameters. The exponential model fits the data better than the linear model, logarithmic model, and power model. Biot's theory also is used to predict the velocity of ultrasound in the demineralized bone. It is shown that the transmission of ultrasonic pulses in the cancellous bone samples can be adequately described using Biot's theory. The different parameters occurring in the Biot theory have been measured independently, and the calculation has been compared with measured velocity of water-saturated bone samples. The correlation coefficients for regression analysis between the experimental velocities and those predicted by Biot's theory are greater than 0.86.

Animals↗

Dry-contact technique for high-resolution ultrasonic imaging.

To accomplish a high-resolution ultrasonic imaging without wetting a sample, the efficiency of the dry-contact ultrasonic transmission is discussed. In this study, a dry-contact interface is formed on a sample by inserting a thin film between water and a sample, and the pressure is working on the interface by evacuating the air between the film and the sample. A model of dry-contact ultrasonic transmission is presented to assess the signal loss accompanied with the transmission. From the determination of the signal loss caused by the transmission using various films, it was found that the higher frequency ultrasound is transmitted effectively into the sample by selecting an optimum film, which can keep the displacement continuity between the film and the sample during ultrasonic transmission. At last, ultrasonic imaging with the sufficient signal-to-noise ratio (SNR) and high lateral resolution was performed on the delamination in a package and the jointing interface of the ball-grid-array package without wetting the packages.

Journal Article↗

Ultrasonic assessment of skin and wounds with the scanning laser acoustic microscope.

The aim of the present study was to test the hypothesis that ultrasonic propagation properties in skin and wound tissue would correlate with material properties such as collagen content, water content, and tensile strength of those tissues. Both ultrasonic speed and ultrasonic attenuation coefficient were directly correlated with tissue collagen content, [r = 0.80 and r = 0.56, respectively (p less than 0.001)]. In addition, ultrasonic speed and attenuation coefficient were inversely correlated with tissue water content, [r = -0.57 and r = -0.73, respectively (p less than 0.001)]. Tensile strength also correlated very significantly with ultrasonic speed (r = 0.90, p less than 0.001), and significantly with attenuation coefficient (r = 0.58, p less than 0.001). The results demonstrate the feasibility of using ultrasound for noninvasively determining the material properties of biologic tissues including healing cutaneous wounds.

Animals↗

Ultrasonic B-scans of the facial/oral periodontium in pigs.

In vitro ultrasonic scans of the oral/facial periodontium of pigs were obtained using a special experimental design and with the help of a newly developed ultrasonic measuring and analysis system. These two-dimensional images distinguish themselves from the one-dimensional RF-echograms and A-scans in that they enable the viewer to have a quick overview of the relationship between different interfaces in a scanned sector. A selection of ultrasonic B-scans proves that the scanned tissues such as gingiva, bone, periodontal ligament, tooth surface and even structures of the inner part of the tooth may be clearly imaged and distinctly differentiated. Furthermore, we demonstrate with manipulations of the pigs periodontium, that the interpretation of the pictures is correct. The primary goal of our investigation was to assess whether the ultrasonic procedure is suitable for the determination of the height of the facial/oral bone crest. On the basis of this study, we may confirm this supposition for the imaging in ultrasonic B-scans.

Alveolar Process↗