PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Cardiac imaging with digital subtraction angiography.

Central cardiovascular anatomy and function have been evaluated with intravenous digital subtraction angiography (DSA). The subtraction techniques used for studying the left ventricle (LV) were mask mode, time interval difference and functional subtraction. Aside from contrast enhancement, a major use of digital fluoroscopy for cardiac applications has been computer-assisted quantitative analysis of LV dimensions and function. Left ventricular volumes and wall thickness determined from DSA studies have correlated closely with direct left ventriculograms and sonocardiometry measurements in patients and animals, respectively. Measurements of segmental LV contraction with DSA correlated closely with direct left ventriculography in normal patients and patients with coronary artery disease. The sensitivity of intravenous DSA for detecting significant coronary artery disease was increased by performing DSA immediately after increasing the myocardial oxygen demands by atrial pacing. The advantages and disadvantages of DSA in relation to other semi-or non-invasive imaging modalities are discussed.

Angiocardiography↗

[The role of digital subtraction angiography in the diagnosis of renal artery injury].

In 3806 patients with vasorenal hypertension the results of kidney angiographic investigation were analyzed. In order to study the efficacy of application of intravenous digital substructional angiography (DSA), the data, obtained in 1621 patients using this method, were compared with such in general group of patients. Informativeness of DSA had constituted 88.9%. Accompanying chronic disease of intestine, excessive body mass, nephrosclerosis are complicating interpretation of obtained results in 10.1% of observations. Possible conduction of ambulatory investigations, decrease traumaticity, invasiveness, duration of procedure, shortening of financial expense constitute the main advantages of DSA. Application of method is recommended in all patients with vasorenal hypertension in ambulatory environment.

Angiography, Digital Subtraction↗

[Acute adverse effects and complications of central venous digital subtraction angiography (DSA). Results of 2,600 studies].

Side-effects and complications from 2,600 intravenous digital-subtraction-angiographies (IV-DSA) are reported. All studies were performed in a standardized technique using a non-ionic contrast agent (Iopromid 370 mg J/ml). Side-effects or complications were noted in 2.5% of all IV-DSA. Most often nausea (0.92%), urticaria (0.5%), angina pectoris (0.5%) and symptomatic alterations of blood-pressure (0.27%) were recorded. 8.4% of all reactions occurred with a delay of at least one hour. All side-effects and complications resolved, partly under symptomatic therapy. In one (0.04%) out of 2,600 studies a severe allergoid reaction occurred, affording intensive-care therapy. With proper patient selection and a suitable technique, IV-DSA may be regarded--within the angiographic methods--as a procedure of relatively low risk.

Aged↗

Evaluation of patients with thoracic aortic dissection by intraarterial digital subtraction angiography.

In 17 patients (mean age 60 years) a thoracic aortic dissection could be revealed by intraarterial digital subtraction angiography with exact delineatin of the proximal and distal extent. Furthermore a visualisation of the true and false lumen and hereby especially the blood flow and its direction in the false lumen could be made. The disclosure of the intimal flap could be seen in patients with flow in both channels, separating the true and the false lumen. In 4 patients the entry could be seen sharply as a hole, but not corresponding to the proximal extent. In 11 patients the entry was seen over a longer area and in 2 patients neither entry nor reentry could be seen. The most distal part of the intimal flap might correspond to the reentry. One anonymous artery, five renal arteries and one coeliac trunc were involved by the dissection. The exact anatomical and pathophysiological nature of the dissection made it possible to decide whether or not the patients should be operated upon and if so, what kind of operation should be chosen.

Aortic Dissection↗

Non-selective digital subtraction angiography in comparison with selective conventional angiography in the diagnosis of carotid artery disease.

In the recent past, non-selective arterial digital subtraction angiography (NSDSA) seemed a less invasive alternative to conventional filmscreen angiography (CFA) in the diagnosis of carotid artery disease. NSDSA obviated the need for selective catheterization with its associated risks but yet took advantage of the DSA method. However, this technique has not found general application although there are no reports that formally assess the (dis)advantages of NSDSA. The aim of our study was to compare the reliability of NSDSA with CFA in evaluation of carotid bifurcations in patients with transient ischemic attacks or partial stroke by reviewing prospectively collected data. Over a 2-year period, 40 patients (upper age limit 65 years) underwent both NSDSA and CFA. Bilateral NSDSA was performed in all 40 patients (80 bifurcations). Bilateral CFA was performed in 27 patients whereas unilateral CFA was carried out in 13 patients (67 bifurcations). Inter- and intra-observer variability for the degree of stenosis was determined by calculation of kappa-values for a 4-point and a 2-point scale. The proportion of interpretable studies was significantly lower in NSDSA. The inter- and intra-observer agreement was on average better in CFA examinations, though the difference was only statistically significant for the inter-observer agreement. The results of our study indicate that images obtained with NSDSA give less reliable information about carotid artery disease than images obtained with CFA. This is in accordance with the fact that NSDSA now seems an abandoned technique.

Adult↗

Carotid stenosis by digital subtraction angiography: reproducibility of the European Carotid Surgery Trial and the North American Symptomatic Carotid Endarterectomy Trial measurement methods and visual interpretation.

PURPOSE: To evaluate different carotid stenosis estimation methods with digital subtraction angiography. METHODS: We assessed the intraobserver reproducibilty and interobserver variability of visual interpretation and the measurement methods used by the European Carotid Surgery Trial and the North American Symptomatic Carotid Endarterectomy Trial. Angiographic stenosis measurements according to both criteria were performed twice by a radiologist, a neurologist, and a vascular surgeon. Eighty bifurcations of consecutive symptomatic patients underwent 480 pairs of measurements. In addition, four radiologists estimated the stenoses visually. RESULTS: Intraobserver consistency was slightly better by the European (kappa, 0.86 to 0.94) than by the North American (kappa, 0.68 to 0.91) trial criteria or by visual interpretation (kappa, 0.79 to 0.81). No significant interobserver variability was found, except in the subgroup of mild stenoses by the North American Trial criteria. By kappa statistic, the interobserver agreement was excellent by the European trial method (kappa, 0.72 to 0.86), good by the North American trial method (kappa, 0.59 to 0.77), and good to excellent by visual evaluation (kappa, 0.68 to 0.88). The visual estimation agreed more closely with the European (kappa, 0.73 to 0.92) than with the North American trial (kappa, 0.55 to 0.74) criteria measurements. CONCLUSIONS: All three methods have good reproducibility in digital subtraction angiography. Interobserver differences become more important in the estimation of mild stenosis.

Adult↗

Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography.

The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive disease. A total of 203 patients were examined in a prospective, multi-centre study at 1.0/1.5 T. Ten vessel segments of one leg were evaluated on-site and by three independent blinded reviewers off-site. One hundred eighty-two patients were evaluable in blinded reading. For pelvis and thigh, there was statistically significant diagnostic agreement between CE MRA and i.a. DSA on-site (94%) and off-site (86-88%). Overall, for detection of clinically significant stenoses, 93% sensitivity and 90% specificity were achieved in on-site evaluation, with 71-76 and 87-93% off-site; for detection of occlusion, sensitivity and specificity on-site were 91 and 97%, with 75-82 and 94-98% off-site. Evaluation was more sensitive on-site than off-site for detection of stenoses and occlusion, whereas specificity was similar. The CE MRA with 1.0-mol gadobutrol gave results comparable to those of i.a. DSA for the larger arteries of pelvis and thigh. Results for calf arteries were compromised by spatial resolution and technical limitations.

Angiography, Digital Subtraction↗

Digital subtraction angiography and dynamic computed tomography in the evaluation of arteriovenous malformations and hemangioblastomas of the spinal cord.

Digital subtraction angiography (DSA) and dynamic computed tomography (DCT) were used in the evaluation of five patients with surgically approachable vascular lesions of the spinal cord, including three arteriovenous malformations (AVM), one hemangioblastoma, and one lesion with a questionable radiographic-surgical diagnosis (AVM? hemangioblastoma?). Digital subtraction angiography was positive in three of the five cases and was particularly informative in the patient with hemangioblastoma, even vis a vis arteriography, which is considered the definitive diagnostic test for these lesions. Dynamic computed tomography was positive in four of the five cases. From this preliminary study, DSA and DCT appear to be useful screening and follow-up procedures which, in a number of aspects, complement each other.

Angiography↗

[Application of digital subtraction angiography in diagnosing and treating portal hypertension].

In order to study the diagnostic and the therapeutic value of digital subtraction angiography (DSA) in portal hypertension, we performed arterioportography 68 times and hepatic venography 11 times on 52 cases with clinically suspected portal hypertension. Seven portal hypertension cases caused by hepatic cancer were treated with transcatheter hepatic artery infusion of anticancerous agent, and one with the stricture of inferior vena cava on hepatic segment was treated by balloon catheter dilatation. Our results showed that, DSA is a safe, reliable and advanced diagnostic technique for portal hypertension, it can also be used as a therapeutic measure in some cases.

Adolescent↗

Performance of the K-edge digital subtraction angiography imaging system at the European synchrotron radiation facility.

In this work we have characterised the K-edge digital subtraction angiography imaging system at the European Synchrotron Radiation Facility (ESRF, Grenoble, France). With this technique, after the minimally invasive intravenous injection of a contrast agent (iodine), two images are recorded simultaneously using monochromatic beams with energies bracketing the iodine K-edge. The image receptor consists of a two-line 432-pixel germanium detector. The logarithmic subtraction of the image set produced results in an iodine-enhanced image, where vessels are clearly visualised and contrast agent concentration can be precisely quantified. We have studied the imaging system in terms of the modulation transfer function, which was measured at the patient position, the 2-D normalised noise power spectrum, calculated for both raw and processed data, and the frequency-dependent detective quantum efficiency, which was calculated directly for final images. In addition, images of cylindrical phantoms with different concentrations of iodine, were also acquired.

Angiography, Digital Subtraction↗

Digital subtraction angiography in the evaluation of intracranial and extracranial vascular disease.

Digital subtraction angiography (DSA) is a method of visualizing the vessels of the body with the intravenous injection of contrast material. Improvements in computers, television systems, and image intensifiers have contributed to the increased image quality of DSA. With DSA, the vessels such as the carotid bifurcations and the intracranial vasculature can be visualized with a 2-3% concentration of contrast material, while with conventional angiography, the concentration of contrast in vessels is 40-50%. Using IV DSA, visualization of the carotid bifurcations is of good or excellent quality 85% of the time. In a high percentage of these cases, IV DSA replaces conventional angiography, although for imaging of the intracranial vessels, IV DSA is not as good as conventional angiography. In most tumor patients, however, conventional intracranial angiography is not needed because IV DSA combined with computed tomography gives sufficient information.

Angiography↗

Intraarterial digital subtraction angiography with carbon dioxide: superior detectability of arteriovenous shunting.

Intraarterial digital subtraction angiography (IADSA) with carbon dioxide (CO2) was performed on 41 patients with liver or renal diseases. CO2 produced no hypersensitivity reactions, and the pain or feeling of warmth was relatively mild compared with iodinated contrast media. Although the image quality of the arterial or capillary phase was inferior to that with iodinated contrast media, the detectability of arteriovenous shunting was excellent. IADSA with CO2 may become an effective method for detecting arteriovenous shunting which cannot be demonstrated with conventional angiography or DSA with iodinated contrast medium.

Adult↗