Separation of large circular DNA by electrophoresis in agarose gels.

The electrophoresis of circular DNA, ranging in size from 4.4 kilobase pairs (kbp) to 220 kbp, was studied in agarose gels. Bacterial artificial chromosome (BAC) DNA was used as a source of large supercoiled and open circular (relaxed) forms. The open circles above approximately 50 kbp were trapped at the sample wells of 1% agarose gels during electrophoresis at 3 V/cm. Field inversion gel electrophoresis (FIGE) was used to relieve the trapping of the open circles in the gels. Using FIGE (30 s forward pulse time), open circles with sizes of 115 and 220 kbp required reverse pulse times of 3 and 6 s, respectively, to free the circles from open-ended gel fibers. A minimum in the gel velocity of the open circles was measured at approximately 20 kbp. Open circles below approximately 20 kbp migrated slower than the supercoiled forms, and above 20 kbp the order was reversed. These results indicate that when the size of the open circles exceeded the average pore size of a gel and it was forced to span multiple pores, the open circles gained a mobility advantage. Decreasing the ionic strength of the electrophoresis buffer significantly decreased the mobility of the smaller circles and slightly increased the mobility of the larger circles.

Buffers↗

Free-flow zone electrophoresis and isoelectric focusing using a microfabricated glass device with ion permeable membranes.

This paper describes a microfabricated free-flow electrophoresis device with integrated ion permeable membranes. In order to obtain continuous lanes of separated components an electrical field is applied perpendicular to the sample flow direction. This sample stream is sandwiched between two sheath flow streams, by hydrodynamic focusing. The separation chamber has two open side beds with inserted electrodes to allow ventilation of gas generated during electrolysis. To hydrodynamically isolate the separation compartment from the side electrodes, a photo-polymerizable monomer solution is exposed to UV light through a slit mask for in situ membrane formation. These so-called salt-bridges resist the pressure driven fluid, but allow ion transport to enable electrical connection. In earlier devices the same was achieved by using open side channel arrays. However, only a small fraction of the applied voltage was effectively utilized across the separation chamber during free-flow electrophoresis and free-flow isoelectric focusing. Furthermore, the spreading of the carrier ampholytes into the side channels resulted in a very restricted pH gradient inside the separation chamber. The chip presented here allows at least 10 times more efficient use of the applied potential and a nearly linear pH gradient from pH 3 to 10 during free-flow isoelectric focusing could be established. Furthermore, the application of hydrodynamic focusing in combination with free-flow electrophoresis can be used for guiding the separated components to specific chip outlets. As a demonstration, several standard fluorescent markers were separated and focused by free-flow zone electrophoresis and by free-flow isoelectric focusing employing a transversal voltage of up to 150 V across the separation chamber.

Electric Conductivity↗

Fast electrophoretic analysis of individual mitochondria using microchip capillary electrophoresis with laser induced fluorescence detection.

The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.

Animals↗

Comparison between pulsed-field and constant-field gel electrophoresis for measurement of DNA double-strand breaks in irradiated Chinese hamster ovary cells.

Pulsed-field gel electrophoresis (PFGE) is one of the most sensitive methods for detecting DNA double-strand breaks in mammalian cells. However, it has been observed that constant-field gel electrophoresis (CFGE), when optimized, can detect breaks with equal efficiency. The migration of DNA from the well and the separation of DNA molecules according to size appear to be different processes; only the latter requires the application of PFGE. CFGE is very sensitive and can detect DNA damage produced by less than 5 Gy of radiation. Low voltage (ca. 0.6 V/cm) during electrophoresis appears to be essential for the migration of the largest fraction of DNA from the agarose plug containing the cells; the electrophoresis run time, cell density in the plug, agarose concentration, nature of detergent and extent of radiolabelling are less important. It is concluded that CFGE is equally sensitive but more rapid and economical than PFGE for the measurement of DNA damage.

Animals↗

Genetic analysis of Pseudomonas aeruginosa by enterobacterial repetitive intergenic consensus polymerase chain reaction (PCR) and arbitrarily primed PCR: gel analysis compared with microchip gel electrophoresis.

OBJECTIVES: To assess the applicability of a newly emerging microchip gel electrophoresis for rapid strain differentiation among clinical isolates of Pseudomonas aeruginosa, and to compare this technique with the traditional gel method for DNA separation. METHODS: One hundred clinical strains of P. aeruginosa obtained from a hospital in northwestern Ohio were tested for reactivity to 3 serotype-specific monoclonal antibodies by enzyme-linked immunosorbent assay. Twelve strains (4 from each serogroup) were selected for DNA analysis by polymerase chain reaction (PCR)-based, single primer DNA fingerprinting methods with 3 different primers: 1 enterobacterial repetitive intergenic consensus PCR and 2 arbitrarily primed PCRs. The PCR products were analyzed by agarose slab gel and microchip gel electrophoresis. RESULTS: Of the 100 clinical isolates tested, 39% (4%, 14%, and 21%) were found to be serotypes 0:3, 0:6, and 0:11, respectively. Twelve strains were chosen for DNA analysis by PCR. The PCR products were analyzed by agarose slab gel electrophoresis and on microchips to determine interspecies diversity. Both methods demonstrated that different serotypes exhibited different electrophoretic patterns. Two strains (clinical strains 6 and 7, serotype 0:6) showed identical patterns, indicating a high degree of relatedness. CONCLUSION: In all cases, there was concordance between the electrophoretic patterns detected by the two methods. The capability of conducting both PCR and microchip gel electrophoresis offers an opportunity for an automated and rapid method for genetic analysis and differentiation among strains of P. aeruginosa and other microorganisms.

Bacterial Typing Techniques↗

Quality assurance and reproducibility of high-resolution two-dimensional electrophoresis and silver staining in polyacrylamide gels.

Qualitative data from high-resolution two-dimensional electrophoresis (2DE) have become clinically useful in immunoglobulin clonality analysis, in resolution of ambiguities in immunofixation typing of paraproteins, and in genetic typing of serum proteins. Since 1986, the authors have been evaluating the College of American Pathologists Reference Preparation for Serum Proteins (RPSP) as a quality control material for 2DE because (1) it is prepared exclusively from pooled human sera, (2) the pool yields a reference pattern of mixed heterozygosity for genetic markers, and (3) RPSP is widely available as a lyophilized preparation that currently serves in the authors' laboratory as a qualitative quality control preparation and that may become a quantitative quality control material or external quality assessment material for 2DE. Using the ISO-DALT 2DE system and silver-staining, the peptide patterns were examined in 11 lots of RPSP and compared with fresh serum and with each other. Consistent differences in the 2DE pattern between RPSP and fresh serum included the presence of freeze-thaw peptides, the presence of degradation spots of apolipoprotein A-I, and the diminution of apolipoprotein spot intensities in RPSP. All lots of RPSP yielded clear identification of the eight serum proteins used for quality control calculations. Run-to-run coefficients of variation for a single lot of RPSP for four parameters of 2DE spot location and gradient reproducibility were comparable with band location reproducibility for the one-dimensional procedures of serum protein electrophoresis and lactate dehydrogenase isoenzyme electrophoresis. It is concluded that the reproducibility, that is, imprecision, of 2DE is the same as one-dimensional clinical electrophoresis techniques and that either RPSP or pooled fresh serum can serve as a satisfactory internal quality control material.

Blood Protein Electrophoresis↗

A comparison of cellulose acetate immunofixation with polyacrylamide gel electrophoresis for the detection of oligoclonal bands in unconcentrated cerebrospinal fluid.

Two methods of electrophoresis for the detection of oligoclonal bands in unconcentrated CSF were compared. A sample of 98 routine CSFs yielded 18 positives by polyacrylamide gel electrophoresis (PAGE) while cellulose acetate electrophoresis with immunofixation (CAIF) gave 13 positives (72% of the PAGE findings). Despite the loss of sensitivity the cellulose acetate electrophoresis was easier to interpret and more suited to a routine hospital laboratory.

Electrophoresis, Cellulose Acetate↗

Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.

The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.

Blood Proteins↗

Process and product monitoring of recombinant DNA-derived biopharmaceuticals with high-performance capillary electrophoresis.

High-performance capillary electrophoresis (HPCE) has emerged over the past 20 years as a powerful multidimensional separation tool that is orthogonal to HPLC and comparable to sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) slab gel methods. HPCE is most frequently applied in the QC release testing of recombinant DNA-derived protein and monoclonal antibody (MAb) biopharmaceuticals. HPCE is a rugged and robust separation tool that can be used like HPLC to monitor the purification process, as well as to analyze bulk drug and drug substances. Examples of the practical applications of the predominant free-solution capillary electrophoresis (FSCE) and capillary gel electrophoresis (CGE) formats of HPCE, applied for process monitoring and product monitoring of recombinant protein and MAb biotherapeutics, are presented. HPCE has been applied in FSCE mode to monitor the purification of the rDNA-derived protein, recombinant human interleukin-4 (rhIL4). FSCE is demonstrated to be a robust method that can be used to monitor multiple column chromatographic purification processes, such as immobiilized metal-ion affinity chromatography (IMAC), ion exchange chromatography (IEC), and size exclusion chromatography (SEC) columns. The FSCE data are used to pool fractions to carry forward for further purification. The FSCE method is compared to the corresponding RP-HPLC method for rhIL4. HPCE has been applied in the CGE mode to monitor the purification of an rDNA-derived IgG4 MAb. CGE is demonstrated to be a convenient and rapid method to profile the purification process, compare purification processes, and provide a fingerprint of the MAb bulk drug that is useful for determining purity and lot-to-lot consistency. The practical advantages and limitations of CGE for process monitoring and product monitoring of MAbs are presented. The CGE method is compared to the high-performance SEC separation of the MAb under nondenaturing (HP-SEC) and denaturing (HP-DSEC) conditions and to SDS-PAGE gels for the analysis and characterization of MAb bulk drugs.

Antibodies, Monoclonal↗

[Restriction enzyme pattern analysis of mycobacteria DNA by capillary electrophoresis with laser induced fluorescence detection].

A new method for rapidly detecting restriction enzyme pattern of mycobacterium deoxyribonucleic acid (DNA) by capillary electrophoresis with laser induced fluorescence detection (CE-LIFD) was developed. Polymerase chain reaction was used to amplify a 439 bp fragment of 65,000 (Mr) heat shock protein gene (hsp65) of mycobacterium. After digesting the amplification products by BstE II and Hae III respectively, the patterns of enzyme cleavaged products were detected by both CE-LIFD and agarose gel electrophoresis (AGE). The experimental parameters of CE were optimized. The restriction enzyme patterns of mycobacterium DNA can be detected under the optimum electrophoresis conditions: a coated capillary column with the length of 50 cm and 100 microm i. d., electrophoresis buffer of 45 mmol/L TBE (trihydroxymethyl aminomethane (Tris)-boric acid-ethylenediaminetetraacetic acid (EDTA)) and 11 kV running voltage. The restriction enzyme patterns for eight species of mycobacteria were studied. Relative standard deviations of the relative migration times of the DNA segments were less than 3.6%. Compared with AGE, CE is more outstanding in resolution and detection time, and it can be applied as a more effective means for DNA restriction enzyme pattern analysis.

Animals↗

Evaluation of a capillary zone electrophoresis system versus a conventional agarose gel system for routine serum protein separation and monoclonal component typing.

Capillary zone electrophoresis of serum proteins is increasingly gaining impact in clinical laboratories. During 2003, we compared the fully automated capillary electrophoresis (CE) system from Beckman (Paragon CZE 2000) with the method agarose gel electrophoresis Sebia (Hydrasis-Hyris, AGE). This new study focused on the evaluation of analytical performance and a comparison including 115 fresh routine samples (group A) and a series of 97 frozen pathologic sera with suspicion of monoclonal protein (group B). Coefficients of variation (CVs %) for the five classical protein fractions have been reported to be consistenly < 9% in within-run and < 10% in between-run imprecision studies with the Paragon 2000 system. The results of the comparison study (group A) demonstrated a good correlation between the CE system and AGE, except for beta-globulin (r = 0.65). Among the 97 pathologic serum samples (group B), there were 90 in which we detected a monoclonal protein by immunofixation (IF) (immunosubtraction (IS) was not used). AGE and Paragon 2000 failed to detect 7 and 12 monoclonal proteins, respectively, leading to a concordance to 92% for AGE and 87% for Paragon 2000 for identifying electrophoretic abnormalities in this group. Beta-globulin abnormalities and M paraprotein were well detected with Paragon 2000. Only 81% (21 vs 26) of the gammopathies were immunotyped with IS by two readers blinded to the IF immunotype. The Paragon 2000 is a reliable alternative to conventional agarose gel electrophoresis combining the advantages of full automation (rapidity, ease of use and cost) with high analytical performance. Qualified interpretation of results requires an adaptation period which could further improve concordance between the methods. Recently, this CE system has been improved by the manufacturer (Beckman) concerning the migration buffer and detection of beta-globulin abnormalities.

Antibodies, Monoclonal↗

Comparison of behaviour of very low density lipoproteins of type III hyperlipoproteinaemia on electrophoresis on paper and on agarose gel with a note on a late (slow) pre-beta VLDL liproprotein.

The diagnosis of type III hyperlipoproteinaemia is based on the presence of a very low density lipoprotein (VLDL) that on electrophoresis has beta instead of the usual pre-beta mobility. This definition is based on paper electrophoresis. Lipoproteins of type III sera were studied by simultaneous electrophoresis on paper and on agarose gel. On paper the ultracentrifugally isolated VLDL had beta mobility, but on agarose gel their mobility was slightly more rapid than beta. It is thus important to consider the electrophoretic conditions in the diagnosis of type III. The diagnosis of type III is further complicated by the presence of agarose gel electrophoresis - contrary to paper - of a second, a 'late pre-beta VLDL' lipoprotein (LPbeta) in 20-30 per cent of both normal and hyperlipoproteinaemic sera. Quantitative lipoprotein analysis of 609 consecutive sera showed that when LPbeta was present, both in normo- and hyperlipoproteinaemia, certain significant lipoprotein changes occurred. Thus VLDL had a high cholesterol content and a raised cholesterol to triglyceride ratio. Furthermore, the triglyceride content of low density lipoproteins (LDL) was increased. These lipoprotein abnormalities are also seen in type III hyperlipoproteinaemia. With regard both to chemical composition of VLDL and LDL and to electrophoretic mobility on agarose gel of VLDL, type III hyperlipoproteinaemia and LPbeta are similar. The possibility of a metabolic relation is discussed.

Cholesterol↗

"High-resolution" mini-two-dimensional gel electrophoresis automatically run and stained in less than 6 h with small, ready-to-use slab gels.

Although two-dimensional (2-D) gel electrophoresis is one of the most powerful techniques for analyzing protein mixtures, its application in routine clinical laboratories is currently limited, because it is time-consuming, complex, and relatively expensive. Here we describe a method for automatically running and staining "high-resolution" mini 2-D electrophoresis gels in less than 6 h, by using "ready-to-use" slab gels and a PhastSystem electrophoresis apparatus. We present 2-D gel electrophoretograms of 25 nL of plasma, as well as their automatic computer analysis. For comparison, a conventional 2-D gel electrophoresis profile of 200 nL of a plasma sample is shown. The technique is easy to perform, highly sensitive, rapid, and potentially useful in semi-routine clinical chemistry laboratories.

Autoanalysis↗

Detection and identification of monoclonal gammopathies by capillary electrophoresis.

Capillary electrophoresis (CE) and immunosubtraction capillary electrophoresis (IS-CE) were compared with the conventional methods agarose gel electrophoresis (AGE) and immunofixation electrophoresis (IFE) for detection and identification of paraproteins. In total, 74 paraproteins out of 468 serum samples were detected by both methods. Seventy-three monoclonal bands with concentrations ranging from 0.6 to 50.9 g/L were detected by the routine method. With CE, 70 paraproteins were detected and quantified on the electropherogram. Four paraproteins were not detected by CE; three of these were IgG (0.6, 1.1, and 2.2 g/L, respectively), and one was a IgM paraprotein (20.3 g/L) that could be visualized by minor changes in the running conditions. In comparison with IFE, 69 paraproteins were typed identically using IS-CE; only one paraprotein (IgMkappa, 14.9 g/L) could not be identified. On the other hand, a monoclonal IgA band that had not been detected by AGE was identified by CE and IS-CE. We conclude that, in general, CE could be a useful method for detection of paraproteins and that IS-CE is a good alternative to IFE. Additional studies are required to investigate the ionic strength and pH of the running buffer, because these prove to be the most crucial factors for routine CE separation of paraproteins.

Electrophoresis, Agar Gel↗

Novel application of PhastSystem polyacrylamide gel electrophoresis using restriction fragment length polymorphism--internal transcribed spacer patterns of individuals for molecular identification of entomopathogenic nematodes.

différences! [editorial] [editorial]onomic way of identifying and assigning nematodes to taxons, which had already been determined either by comparative sequence analysis of nuclear rDNA internal transcribed spacer (ITS) region or by other methods of molecular or conventional taxonomy, is provided. Molecular identification of entomopathogenic nematodes (EPN) can be upgraded by basing it on PhastSystem polyacrylamide gel electrophoresis (PAGE) analysis of restriction fragment length polymorphism (RFLP) patterns of polymerase chain reaction (PCR)-amplified DNA derived from single nematodes of Steinernema or Heterorhabditis spp. Although analysis from single worms has previously been made on agarose gel, the resolution on PhastSystem PAGE gel is much higher. The DNA sequences selected for analysis were those constituting the internal transcribed spacer region between the 18S and 26S rDNA genes within the rRNA operon. RFLP analysis was carried out by gel electrophoresis on the PhastSystem (Pharmacia) as detailed elsewhere (Triga et al., Electrophoresis 1999, 20, 1272-1277. The downscaling from conventional agarose to PhastSystem gels resulted in pattern of DNA fragments differing from those obtained with agarose gel electrophoresis under conventional conditions by increasing the number of detected fragments. The approach supported previous species identifications and was able to identify several unclassified isolates, such as those from Hungary and Ireland, and provides a method for identification of previously unclassified strains. We confirmed that Heterorhabditis "Irish Type", represented by two strains of different geographical origin, comprise a species different from H. megidis. We also confirmed that strain IS5 belongs to the species H. indicus rather than to H. bacteriophora, as had been suggested previously.

Animals↗

Structural studies on sugar chains of carbohydrate-deficient transferrin from patients with alcoholic liver disease using lectin affinity electrophoresis.

It is well-known that microheterogeneity of human serum transferrin observed in alcoholics manifests as sialic acid-deficient transferrin isoforms, otherwise known as carbohydrate-deficient transferrin (CDT). A recent study demonstrated that serum CDT lacked one or both of the entire carbohydrate chains but the investigation required several troublesome procedures. The aim of the present study was to confirm the sugar chain structures of serum transferrin, and of serum CDT in particular, from patients with alcoholic liver disease (ALD) using conventional lectin affinity electrophoresis which might be useful in the clinical setting. The serum CDT obtained from ALD-patients was partially purified using an anion exchanger. Serum transferrin and the partially purified serum CDT were investigated by concanavalin A (Con A)- and Datura stramonium agglutinin (DSA)-affinity electrophoresis followed by antibody-affinity blotting and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with Western blotting. By Con A-affinity electrophoresis, serum CDT was separated into weakly reactive and nonreactive transferrins which showed slower electrophoretic mobilities than those from the healthy controls. Moreover, nearly all of the serum CDT was nonreactive with DSA. On SDS-PAGE, the molecular masses of serum CDT were estimated to be approximately 75 and 72 kDa, which corresponded to those of partially and completely deglycosylated transferrin obtained from the healthy controls (78 kDa), respectively. In conclusion, these results indicated that the sugar chain structures of serum CDT from patients with ALD show not merely a loss of terminal sialic acids, but also the absence of asparagine-N-linked oligosaccharides.

Antibody Affinity↗

Application of capillary nongel sieving electrophoresis for gene analysis.

Capillary electrophoresis (CE) has proved to be a strong tool for DNA analysis and has found abundant applications in the fields of restriction fragment sizing, mutation screening, polymerase chain reaction (PCR) product characterizing and forensic identifying. CE may be the main alternative to slab gel electrophoresis. Capillary nongel electrophoresis is the most favorable mode when aiming for this purpose because of its advantages of long lifetime, easy operation, good reproducibility, and low expense. In this paper, a new kind of sieving matrix, with mannitol as the additive for capillary electrophoresis, as well as related methods and their application for gene analysis were reported. Nine DNA fragments amplified by multiplex PCR from a normal dystrophin gene were well separated by this system. Three different deletions were found in Duchenne muscular dystrophy (DMD) patients. Three to four copies of the sex-determination region of the Y chromosome (SRY) gene, as well as the phenylalanine hydroxylase (PAH) gene, could be detected in mixed samples. The frequencies of short tandem repeats (STR) in PAH genes was analyzed in 61 normal Chinese individuals and 6 phenylketonuria families. One case of prenatal gene diagnosis was performed. By using this matrix, CE coupled with reverse transcription PCR (RT-PCR), the analysis of the alternative splicing expression pattern of the fragile X mental retardation 1 (FMR1) gene in adult lung tissue was achieved.

Adult↗

Experimental observation of light-induced solitary waves of analyte bands in capillary electrophoresis.

The phenomenon of electrophoresis in free solution has been studied theoretically down to the molecular level for decades. In addition, intermolecular photo-induced proton transfer reactions, which occur in a wide class of molecules (phenols and aminoarenes) as well as proteins (green fluorescent protein), were also studied extensively. However, the study of the effect of light-induced electrophoretic mobility changes of the analytes in electrophoresis was begun only recently. In the present work, capillary zone electrophoresis was chosen as the environment to measure the magnitude of these electrophoretic mobility shifts induced by light. Background electrolytes (running electrolytes) with high refractive indices were developed, allowing the capillary to work like an optical fiber. The experimental conditions for obtaining stable coupling and guided laser light along the liquid core are discussed. Experimental evidence of band compression is observed, leading to a solitary wave behavior of the analyte band (2-naphthol). These solitary waves result from competition between thermal diffusion (dispersion mechanism) and a nonlinear (band compression) effect due to the combined electrophoresis phenomenon and absorption of guided light by the molecules of the band (which are subjected to a "reversible intermolecular proton transfer reaction" as one of their decay routes). The possibilities of applying this effect to different methods and techniques are also discussed.

Buffers↗