PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROSURGERY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Distal thermal injury from monopolar electrosurgery.

Lysis of infrahepatic adhesions during laparoscopic cholecystectomy was attempted by using monopolar electrocautery. The flow of current was seen to follow an unpredictable pathway and almost causing a thermal injury to an adjacent small bowel loop. A brief discussion of pertinent bioelectrical principles is also presented.

Adult↗

A comparison of mucosal incisions made by scalpel, CO2 laser, electrocautery, and constant-voltage electrocautery.

This study compares the histologic effects of scalpel, CO2 laser, electrosurgery, and constant-voltage electrosurgery incisions on the mucosal tissue of swine. Tissue studies comparing the CO2 laser with the scalpel and electrosurgery have been done. However, a gross and histologic comparison of the effects of all three techniques on oral mucosal tissue has not been reported. A swine model of both tongue and buccal mucosa was used to compare the scalpel, CO2 laser, electrosurgery unit, and constant-voltage electrosurgery unit in an effort to assess their value in oral surgery. Tissue samples of tongue and buccal mucosal incisions and excisions were histologically examined at 0, 3, 7, 14, 28, and 42 days after surgery to evaluate tissue damage and wound healing properties induced by the four instruments. The instruments were also evaluated for performance and ease of use. On subjective evaluation of ease of use, constant-voltage electrosurgery scored highest (p < 0.05) on a scale of 0 to 4, followed by the CO2 laser. Speed of incisions and excisions, measured in seconds, was fastest with the scalpel (p < 0.001) and electrosurgery unit (p < 0.05). The amount of bleeding, as evaluated on a scale of 0 to 4, was least for electrosurgery (p < 0.001) and CO2 laser (p < 0.001). Histologic damage, as expected, was least with a scalpel. The extent of epithelial damage lateral to the wound edge and the extent of collagen denaturation were the lowest with the scalpel (p < 0.001), followed by constant-voltage electrosurgery. The wounds created by all four instruments displayed intact epithelium by 4 weeks, and granulation tissue peaked at 4 weeks with all methods except constant-voltage electrosurgery, where granulation tissue was still prevalent at week 6. Constant-voltage electrosurgery and the CO2 laser provided the best combination of ease of use, hemostasis, and lack of tissue injury among the instruments compared. Incisions and excisions made with constant-voltage electrosurgery required less time than those made with the laser, but constant-voltage electrosurgery wounds also had significantly more granulation tissue in later weeks of the study, suggesting that wound healing may be delayed.

Animals↗

Pacemakers and implantable cardiac defibrillators in dermatologic surgery.

BACKGROUND: Electrosurgery used during dermatologic surgical procedures can cause malfunction of pacemakers and implantable cardiac defibrillators (ICDs), producing problems with rhythm detection, proper function, or alteration of the device. Well-documented safety data on electrosurgery in patients with cardiac devices are limited. At Mayo Clinic in Rochester, Minnesota, the Pacemaker Clinic manages all patients with pacemakers and ICDs undergoing dermatologic surgery. The preoperative and postoperative evaluations provide a unique opportunity to evaluate the safety of dermatologic surgery with electrosurgery in such patients. OBJECTIVES: The objective was to review the evaluation and management, by an experienced cardiology team, of patients with cardiac devices undergoing dermatologic surgery and to characterize perioperative complications. METHODS: A retrospective chart review of all patients identified with pacemakers or ICDs undergoing Mohs micrographic or dermatologic excisional surgery with electrosurgery at Mayo Clinic 2001 through 2004 were identified. Data were abstracted to identify any possible complications. RESULTS: The 173 patients with pacemakers and 13 with ICDs undergoing dermatologic surgery had no documented complications from electrosurgery. CONCLUSION: The lack of complications associated with pacemakers and ICDs with electrosurgery is reassuring. The authors support published recommendations about techniques and precautions to optimize safety during electrosurgery in patients with cardiac devices. The care of patients with ICDs in particular requires special consideration.

Adult↗

Comparison of monopolar and bipolar electrosurgical modes for restorative dentistry: a review of the literature.

This review of the literature was undertaken as part of a wider investigation of effective hemostasis in vital pulp therapy. Two general types of electrosurgical units are available: monopolar and bipolar. This review compares the features of both systems. An important hazard referred to as channeling, funneling, or current crowding is described and associated with pulp therapy injury for the first time. Important safety features of bipolar electrocoagulation are identified and applied to dental procedures. Articles were selected by means of a search of MEDLINE, the U.S. National Library of Medicine's bibliographic database, for literature published between 1966 and 2001 on the topics of electrosurgery, electrocautery, electrolysis, and lasers. A search also was completed from a pulp therapy perspective to determine the use of electrosurgery on the pulp. Numerous articles and texts published between 1900 and 1965 had been reviewed previously; their bibliographies were explored and cross-referenced for pertinent reports. Laparoscopic applications of electrosurgery were reviewed for general background information and for clarification of safety and hazard issues; no exclusionary criteria or date limitations were imposed. Beyond the literature review, numerous authors and developers in the field of electrosurgery were contacted for clarification of concepts and controversies. More than 120 articles and texts related to electrosurgery were reviewed, and another 100+ articles were reviewed in the area of pulp therapy.

Dental Pulp↗

High energy laser irradiation and electric surgery for obstructive gastrointestinal cancer.

A total of 35 patients with advanced obstructive gastrointestinal cancer received monopolar electrosurgery and Nd: YAG laser therapy from January 1985 to June 1988. These included 13 cases of esophageal cancer (U/3 6, M/3 2, L/3 5), 14 case of gastric cancer (cardia 7, corpus 3, antrum 4), and 8 cases of rectal cancer. Twenty (esophageal 9, stomach 8, rectal 3) of 35 patients had much improved results, with the size of the lesion reduced over 90%, and the endoscope could smoothly pass through the stenotic area after electrosurgery or laser therapy. The other 12 patients had partially improved results with the tumor size being reduced 50-90% and the patients could take semiliquid food easily. Both groups of much improved or partial improved had a statistically significant difference (P less than 0.01) compared to the group of failures to treatment. Two patients developed bleeding after treatment. Twenty-one patients died of causes other than complications of electrosurgery or laser therapy. The average survival was 6.8 months. Nd: YAG laser and electrosurgery can provide good palliative results and contribute to a good quality of life in advanced obstructive gastrointestinal cancer.

Adult↗

Bacteremia following laser and conventional surgery in hamsters.

The CO2 laser prevents bleeding by sealing blood and lymph vessels as it vaporizes tissue. Bacteremia following oral surgery might not occur under these conditions. To test this hypothesis, a 0.2-mm-deep incision 1 cm long was made in the right buccal cheek pouch of hamsters using either laser, electrosurgery, or a scalpel. Twenty minutes later, 1 mL of blood was taken from each animal by cardiac puncture, inoculated on a blood agar medium, and incubated anaerobically for 4 days; then the colonies were counted. Using an operational definition of bacteremia as five colonies or more per plate, there were no positive results out of 18 trials (0/18) for laser surgery, 7/8 for electrosurgery, and 8/12 for scalpel surgery. Based on the Student t test using the binomial distribution, the laser produced statistically less bacteremia than the other two methods (P less than .01). Because the five-colony cutoff was arbitrary, the nonparametric Wilcoxon Rank test was also used. Colony formation from blood from the laser group was significantly less than from the electrosurgery group (P less than .01) and the scalpel group (P less than .05). The laser surgery group was not statistically different from the control (nonsurgerized) group. These results suggest that there is a considerable bacteremia following scalpel and electrosurgery, but that laser surgery produces no bacteremia.

Animals↗

Effectiveness of photodynamic ablation for destruction of endometrial explants in a rat endometriosis model.

OBJECTIVE: To evaluate the potential of photodynamic therapy with aminolevulinic acid (ALA-PDT) for ablation of endometrial explants in a rat endometriosis model and to compare the effect of ALA-PDT, electrosurgery, and surgical resection on normal peritoneum. DESIGN: Prospective controlled experimental trial. SETTING: University medical center. ANIMAL(S): Mature Sprague-Dawley female rats. INTERVENTION(S): Induction of endometriosis and subsequent treatment with ALA-PDT; electrosurgery, and simple resection, and ALA-PDT of normal peritoneum. MAIN OUTCOME MEASURE(S): Histopathological assessment. RESULT(S): Systemic ALA followed by exposure to photoactivating light for 10 or 15 minutes resulted in ablation of all explants harvested 3-4 days after treatment. Permanent destruction was confirmed by absence of regrowth by week 3. Exposure of normal peritoneum to ALA-PDT resulted in initial necrosis, with complete recovery by day 16. Adhesions were present on day 16 in 50% of cases after electrosurgery and in 100% of cases after resection. No adhesions were present in ALA-PDT-treated animals. CONCLUSION(S): Systemic ALA followed by exposure to photoactivating light at relatively low power densities for periods as brief as 10 minutes resulted in ablation of endometriotic explants. Exposure of normal peritoneum to ALA-PDT resulted in complete resurfacing. Both electrosurgery and surgical resection resulted in a greater incidence of surface adhesions.

Aminolevulinic Acid↗

Electrosurgical methods for arthroscopic meniscectomy: A review of the literature.

PURPOSE: To outline the development of electrosurgical (radiofrequency) devices, explain the basic principles, and review the current orthopaedic literature regarding the application of electrosurgery to arthroscopic partial meniscectomy. MATERIALS AND METHODS: The history and principles of electrosurgery were obtained from various pertinent texts and journal articles. A literature search was performed using MEDLINE; reviewed articles consisted of articles in the English language cataloged between 1966 and January 1999. RESULTS: The history and principles of electrosurgery are reviewed. The articles pertaining to arthroscopic electrosurgical meniscectomy are discussed with a separate discussion on the potential complications of using radiofrequency energy for meniscal ablation, including articular cartilage damage, osteonecrosis, and damage caused by irrigant. CONCLUSION: Electrosurgery has been shown to be an effective tool in arthroscopic meniscectomy. Further research and refinement is warranted because it may show superiority to other methods in certain situations.

Arthroscopy↗

Current electrosurgical practice: hazards.

The beneficial aspects of electrosurgical cutting and coagulating techniques are nearly too numerous to list. The major contribution and electrosurgery has been to drastically reduce both blood loss and operative time resulting in reduced morbidity and mortality. There are, as well, procedures which would not be possible without electrosurgery. Nonetheless, as a source of high energy in the operating theatre, there are hazards attendant to the use of electrosurgery. Moreover, since high frequency signals are involved, the nature of the machine-patient interactions creating a potentially hazardous situation many not be easily identifiable. The significant hazards of electrosurgery in use are: explosions of combustible mixtures including anaesthesia gas and bowel gas; interference with instruments and pacemakers; stimulation of excitable tissues which on occasion has apparently caused ventricular fibrillation; and accidental radio frequency burns. Though the rate of incidents is low--in terms of the number per 100 000 procedures--individual accidents tend to be fairly catastrophic and traumatic to both the patient and surgical team. Frequently, litigation results from these accidents. Though the hazards cannot be eliminated, the probability of an incident can be minimized by careful technique.

Burns↗