PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Power”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK.

OBJECTIVE: To compare methods of calculating intraocular lens (IOL) power for cataract surgery in eyes that have undergone myopic LASIK. DESIGN: Noncomparative case series. PARTICIPANTS: Eleven eyes of 8 patients who had previously undergone myopic LASIK (amount of LASIK correction [+/-standard deviation], -5.50+/-2.61 diopters [D]; range, -8.78 to -2.38 D) and subsequently phacoemulsification with implantation of the SA60AT IOLs (Alcon Surgical, Inc., Fort Worth, TX) were included (refractive error after cataract surgery, -0.61 +/- 0.79 D; range, -2.0 to 1.0 D). METHODS: We evaluated the accuracy of various combinations of: (1) single-K versus double-K (in which pre-LASIK keratometry is used to estimate effective lens position) versions of the IOL formulas; the Feiz-Mannis method was also evaluated; (2) 4 methods for calculating corneal refractive power (clinical history, contact lens overrefraction, adjusted effective refractive power [EffRP(adj)], and Maloney methods); and (3) 4 IOL formulas (SRK/T, Hoffer Q, Holladay 1, and Holladay 2). The IOL prediction error was obtained by subtracting the IOL power calculated using various methods from the power of the implanted IOL, and the F test for variances was performed to assess the consistency of the prediction performance by different methods. MAIN OUTCOME MEASURES: Mean arithmetic IOL prediction error, mean absolute IOL prediction error, and variance of the IOL prediction error. RESULTS: Compared with double-K formulas, single-K formulas predicted lower IOL powers than the power implanted and would have left patients hyperopic in most cases; the Feiz-Mannis method had the largest variance. For the Hoffer Q and Holladay 1 formulas, the variances for EffRP(adj) were significantly smaller than those for the clinical history method (0.43 D2 vs. 1.74 D2, P = 0.018 for Hoffer Q; 0.75 D2 vs. 2.35 D2, P = 0.043 for Holladay 1). The Maloney method consistently underestimated the IOL power but had significantly smaller variances (0.19-0.55 D2) than those for the clinical history method (1.09-2.35 D2; P<0.015). There were no significant differences among the variances for the 4 formulas when using each corneal power calculation method. CONCLUSIONS: The most accurate method was the combination of a double-K formula and corneal values derived from EffRP(adj). The variances in IOL prediction error were smaller with the Maloney and EffRP(adj) methods, and we propose a modified Maloney method and second method using Humphrey data for further evaluation.

Adult↗

Mechanical energy and power flow of the upper extremity in manual wheelchair propulsion.

OBJECTIVE: To investigate the characteristics of mechanical energy and power flow of the upper limb during wheelchair propulsion. DESIGN: Mechanical energy and power flow of segments were calculated. BACKGROUND: Very few studies have taken into account the mechanical energy and power flow of the musculoskeletal system during wheelchair propulsion. Mechanical energy and power flow have proven to be useful tools for investigating locomotion disorders during human gait. METHODS: Twelve healthy male adults (mean age, 23.5 years) were recruited for this study. Three-dimensional kinematic and kinetic data of the upper extremity were collected during wheelchair propulsion using a Hi-Res Expert Vision system and an instrumented wheel, respectively. RESULTS: During the initiation of the propulsion phase, joint power is generated in the upper arm or is transferred from the trunk downward to the forearm and hand to propel the wheel forward. During terminal propulsion, joint power is transferred upward to the trunk from the forearm and upper arm. The rate of change of mechanical energy and power flow for the forearm and hand have similar patterns, but the upper arm values differ. CONCLUSIONS: Joint power plays an important role in energy transfer as well as the energy generated and absorbed by muscles spanning the joints during wheelchair propulsion. RELEVANCE: Energy and power flow information during wheelchair propulsion allows us to gain a better understanding of the coordination of the movement by the musculoskeletal system.

Adult↗

Market power in the United States red meatpacking industry.

The basic question asked in the beginning of this article was whether the evidence from research is persuasive enough to conclude that competition in the meatpacking industry is deficient. The literature review led to the conclusion that the answer is no. Research varies widely in terms of data and methodologic approaches. The research, however, clearly finds evidence of market power. Many SCP studies indicated the existence and exercise of market power, but the failure of the paradigm makes definitive conclusions dangerous. The NEIO studies showed a persistent gap between the price of livestock and marginal costs but the studies did not incorporate sufficient detail to prove specific behavior. Azzam and Anderson [4] conducted an extensive review of competition in meatpacking. In their summary, they offered criticisms of the SCP approach and the conduct parameter approach. These investigators concluded that the body of empiric evidence was insufficient to persuasively argue that the meatpacking industry was not competitive. Sexton [69] discussed more recent critiques of the conduct parameter appraoch. Despite its weaknesses, he concluded that market power estimates in meatpacking are modest but that structural changes on balance are beneficial, from an efficiency viewpoint. Examining the evidence either by data aggregation, methodology, or time period results in little difference in the qualitative interpretation. The research community has done what Nicholls [2] said was needed. The need remains relevant. The research leaves us with a clear picture and nagging questions. Azzam and Anderson [4] recommended that further research focus on the process of competition or the rivalrous interaction between competitors, and on competitors' strategies for responding to technologic and market forces, as the business history of the industry suggests. Specifically, they recommended two approaches. First, to develop empiric pricing models for short-term monitoring. Such models infer conduct from spatial price linkages rather than from concentration as do SCP studies or estimation of conduct parameters as do NEIO studies. Second, to study the dynamics of the competitive process, making use of data describing changes at the firm and plant level, to better understand the effect of market and technologic forces on the evolution of firm behavior and industry structure. After discussing existing research quality and future research needs, two practical things remain to do. The first centers on the following question: How important are the relatively small measures of market power? Most believable price distortions are found to be 3% or less. These distortions are below the 5% regulatory standards related to mergers used by the US Department of Justice and US Federal Trade Commission [70]. These standards, however, are guidelines and not law. Antitrust laws state that the exercise of market power is illegal. Courts and regulatory agencies also have not defined how much market power is significant and for how long a firm or firms must maintain significant market power [71]. From the viewpoint of public welfare, small impacts on price make a substantial difference to livestock producers and rival meatpacking firms. In relatively low-profit commodity businesses, small degrees of market power have significant profit implications. Small price or percentage impacts represent large total dollar amounts, especially over long time periods. To some, the evidence of market power provides clear reasons for antitrust lawsuits, conclusive evidence of weak and disinterested antitrust enforcement, and undeniable grounds for corrective legislation. If we conclude that action is needed, then the second issue emerges: What should be done and will our actions result in a net improvement? The research reviewed in the article by MacDonald elsewhere in this issue clearly shows the economic benefits of large meat processing firms. Likewise, some of the research reviewed here shows that increased concentration benefits producers and consumers. Some of the benefits of lower costs are passed on to producers through improved prices. The clear problems seen in the 1910s and 1920s--the pools and trusts--are not present in the 1990s and 2000s. Legislative action requiring the restructuring of the meatpacking industry or limiting behavior (similar to the Packer Consent Decree of 1920) will come at a large cost to the industry and society. So what should be done? Some people want to do nothing and allow the market to function unencumbered by political action. This approach ignores the problems seen in research. Some people want to go back in time, forgetting the economic incentives for change. They would legislate change in the market structure where they perceive problems, break up large meatpacking firms, restrict supposed problematic conduct, and eliminate contracting and vertical integration. Some people want to treat agriculture as a unique sector of society and create laws and regulations applicable to agriculture alone, regardless of whether the issues driving these actions apply to other sectors of the economy. Little, if any, thought is given to public and private costs or public and private benefits. Structural changes are clear. Research findings on the impacts and consequences are robust. What should be done, however, is not clear or robust. We are in the realm of second-best choices. The fact that we are in a realm of second-best choices is not satisfying to me nor will it likely be to agricultural producers and policy makers. What to do from here is not an economic decision (i.e., economics cannot provide a clear best answer). Rather, it is a political and public choice question that has economic implications: What do we want our livestock and meat industry to look like?

Animals↗

Intraocular lens power calculations in patients with extreme myopia.

PURPOSE: To determine the variables that might contribute to improved intraocular lens (IOL) power calculations preoperatively in cataract patients with extreme myopia. METHODS: This retrospective study included 50 patients with extreme myopia and axial lengths longer than 27.0 mm. All patients had clear corneal phacoemulsification by the same surgeon and implantation of the Domilens SiFlex 1 IOL (power range -6.0 to +5.0 diopters [D]). The performances of the SRK/T, Hoffer Q, Holladay 1, and Holladay 2 formulas in predicting an IOL power that would meet the target refraction of +/-1.00 D were compared. RESULTS: The formulas tended to suggest underpowered IOLs, more severe in eyes with axial lengths greater than 30.00 mm. These eyes accounted for most of the minus-power IOLs implanted. Back calculations of axial lengths in patients with minus-power IOLs showed that, on average, emmetropia could have been predicted by choosing shorter axial lengths (up to 2.72 mm shorter) than those used in the original IOL power calculations. Preoperative B-scan ultrasonography demonstrated the presence of a posterior pole staphyloma temporal to the optic nerve in several patients who required minus-power IOLs, which suggests that axial length measurement problems were a major source of IOL calculation errors in these patients. CONCLUSIONS: In eyes with axial lengths longer than or equal to 27.0 mm, current third- and fourth-generation lens calculation formulas have a tendency to over minus patients between -1.0 and -4.0 D. The formulas appear to perform better for plus-power IOL implantation than for minus-power IOL implantation. The use of B-scan ultrasonography to locate posterior pole staphylomas may improve the accuracy of IOL calculations in eyes with extreme myopia.

Accommodation, Ocular↗

Effect of keratometer and axial length measurement errors on primary implant power calculations.

Analytical predictions of primary implant power using presumptive errors in keratometer and axial length measurements were performed using the modified Binkhorst, modified Colenbrander, Holladay, Hoffer, and SRK II equations. These predictions demonstrate that the contributions to primary implant power error resulting from inaccurate axial length and keratometer measurements are algebraically additive. In eyes with a normal axial length, the resulting implant power determination error can be larger than differences in implant power prediction among these five IOL equations. Calculations using measurement errors of 0.2 mm in axial length and 0.50 diopter (D) in corneal curvature predicted a worst case primary implant power error of +/- 1.17 D. These calculations were performed using an axial length and corneal curvature near the population mean. In contrast, implant equation variability was determined to be +/- 0.19 D by calculating the standard deviation of the five implant power formulas with the measurement errors set to zero. Implant power prediction errors were increased when a flat cornea was paired with an axial hyperopic or an axial myopic eye. These combinations maximize the implant power error resulting from both implant formula variation and inaccurate measurements. Primary implant power error prediction tables are presented for emmetropic, axial hyperopic, and axial myopic eyes, as a function of presumed errors in axial length and corneal curvature. These error predictions clearly show that inaccuracy in axial length measurements and keratometer readings can be first order determinants of postoperative spherical refractive error.

Biometry↗

Verification of the vertex powers of varifocal rigid contact lenses.

INTRODUCTION: Increasingly aspherical optics are used in contact lens designs to produce a varifocal effect to correct presbyopia. Whilst no current ISO standard describes a method to verify these products, the vertex power needs to be verified by the manufacturer and optometrist. Visionix claim that the VC2001 instrument is able to resolve the vertex power of complex contact lenses and that it has been adopted by contact lens manufacturers as their "gold standard" method of measure. Practitioners rely on the focimeter for contact lens verification and accept that it has poorer resolution. This raises the question of whether practitioners can verify the vertex powers of varifocal contact lenses to a sufficient sensitivity. The purpose of this study is to determine whether a focimeter can differentiate between various vertex powers incorporating differing degrees of asphericity that are used in contact lens designs. METHODS: A range of varifocal contact lenses were used with single vision contact lenses as controls. Three types of focimeters were used: a manual focimeter, a projector focimeter and a computerised focimeter (standard and contact lens modes). The VC2001 assessed the vertex powers over the optical zone and was used as a reference for the focimeters. The measures from the VC2001 and the focimeters were analysed by discrepancy analysis. RESULTS: All discrepancy measures fell outside two standard deviations for either the varifocal contact lenses or the single vision contact lenses when the focimeters were compared to the VC2001. This raises the issue of whether the focimeters are measuring the same parameter as the VC2001. Only the analysis of the repeated measurements from the manual focimeter for single vision contact lenses demonstrated an acceptable measure of precision (+/-0.21, 2S.D.) with a very small degree of bias (mean difference -0.024, +/-0.02 [2S.E.]). CONCLUSION: These results suggest that the manual focimeter can measure the vertex powers for single vision contact lenses to an acceptable degree of precision. The vertex powers of varifocal lenses cannot be verified using standard practice equipment. The VC2001 has poor precision for power measurements and may not be measuring the same parameter as the focimeters and therefore questions the validity of the VC2001 as the "gold standard" for vertex power measurement.

Journal Article↗

Increased power generation in a continuous flow MFC with advective flow through the porous anode and reduced electrode spacing.

The maximum power generated in a single-chamber air-cathode microbial fuel cell (MFC) has previously been shown to increase when the spacing between the electrodes is decreased from 4 to 2 cm. However, the maximum power from a MFC with glucose (500 mg/L) decreased from 811 mW/ m2 (R(ex) = 200 omega, Coulombic efficiency of CE = 28%) to 423 mW/m2 (R(ex) = 500 omega, CE = 18%) when the electrode spacing was decreased from 2 to 1 cm (batch mode operation, power normalized by cathode projected area). This decrease in power was unexpected as the internal resistance decreased from 35 omega (2-cm spacing) to 16 omega (1-cm spacing). However, providing advective flow through the porous anode toward the cathode substantially increased power, resulting in the highest maximum power densities yet achieved in an air-cathode system using glucose or domestic wastewater as substrates. For glucose, with a 1-cm electrode spacing and flow through the anode with continuous flow operation of the MFC, the maximum power increased to 1540 mW/m2 (51 W/m3) and the CE increased to 60%. Using domestic wastewater (255 +/- 10 mg of COD/L), the maximum power density was 464 mW/m2 (15.5 W/m3; CE = 27%). Although flow through the anode could lead to plugging, especially for particulate substrates such as domestic wastewater, the system was operated using glucose for over 42 days without clogging. These results show that power output in this air-cathode single-chamber MFC can be increased by reducing the electrode spacing if the reactors are operated in continuous flow mode with advective flow through the anode toward the cathode.

Electrochemistry↗

Design and power of a population pharmacokinetic study.

PURPOSE: This paper investigated the influence of critical design factors on the power of a population pharmacokinetic (PK) study for identifying subpopulations that have different drug clearance than the typical population. METHODS: A study simulation approach was used for the power estimation. The design factors included the number of subjects, sampling scheme, and compliance. RESULTS: The false positive rates of incorrectly identifying a subpopulation were estimated for several scenarios. The false positive rates of the population PK study was relatively low, except when the numbers of subjects with full profiles and the subjects with troughs were distributed between populations in an unbalanced manner. The total number of subjects did not seem to have as much influence on study power as the number of subjects in the subpopulation, as long as the total number of subjects was significantly larger than the subpopulation. The variability of sampling time played an important role in both the statistical power and the accuracy of the estimated difference in clearance. Taking three samples provided greater power and better accuracy than taking two samples per subject. Taking only trough samples provided little power and poor estimation of clearance difference. Adding subjects with full profiles to a study with only trough samples taken in other subjects did not satisfactorily improve the clearance estimation. It was critical to account for dosing record in the population PK analysis to achieve appropriate power and accuracy. If the variability in dosing time was accounted for in the analysis, it improved the accuracy of the estimated difference in clearance. Missing dose administrations reduced the study power and resulted in deviation of estimated clearance difference. CONCLUSIONS: The power of a study should be determined prospectively to ensure appropriate study design for specific study objectives.

Absorption↗

Power of QTL detection using association tests with family controls.

The power of testing for a population-wide association between a biallelic quantitative trait locus and a linked biallelic marker locus is predicted both empirically and deterministically for several tests. The tests were based on the analysis of variance (ANOVA) and on a number of transmission disequilibrium tests (TDT). Deterministic power predictions made use of family information, and were functions of population parameters including linkage disequilibrium, allele frequencies, and recombination rate. Deterministic power predictions were very close to the empirical power from simulations in all scenarios considered in this study. The different TDTs had very similar power, intermediate between one-way and nested ANOVAs. One-way ANOVA was the only test that was not robust against spurious disequilibrium. Our general framework for predicting power deterministically can be used to predict power in other association tests. Deterministic power calculations are a powerful tool for researchers to plan and evaluate experiments and obviate the need for elaborate simulation studies.

Analysis of Variance↗

Recent temporal trend monitoring of mercury in Arctic biota--how powerful are the existing data sets?

The goal of this paper is to describe and discuss statistical power with respect to mercury in Arctic biota, using data gathered during the past two or three decades, mostly under the auspices of AMAP Phases I and II. It will describe the current levels of power of existing data sets to detect temporal trends of Hg concentrations. If the desired power is fixed to an appropriate magnitude, the minimum size of a detectable trend within a specified time period or the number of years that is required to detect a certain trend could be estimated provided that the random between-year variation for the current time-series is known. These various measures of performance of the AMAP mercury time-series, derived from the power analysis, are discussed in some detail. The number of years required to detect a certain trend at a particular power at a specific Type I error rate (alpha) is compared with the actual number of years available when the AMAP Phase II assessment was carried out. In general the investigated time-series were too short to possess an acceptable statistical power. The effect of varying the Type-I error rate, the slope of a trend and the desired power is investigated to rank the importance of the various components regulating the statistical power. The consequence of sampling less frequently than once a year is considerable loss of power.

Animals↗

Impact of changes in respiratory frequency and posture on power spectral analysis of heart rate and systolic blood pressure variability in normal subjects and patients with heart failure.

1. Autonomic dysfunction is a major feature of congestive cardiac failure and may have an important role in determining progression and prognosis. The low-frequency/high-frequency ratio derived from power spectral analysis of heart rate variability has been proposed as a non-invasive method to assess sympatho-vagal balance. However, the effects of different respiratory rates or posture are rarely accounted for, but may be relevant in patients with heart failure in whom clinical improvement is accompanied by a fall in respiratory rate and an increased proportion of the day in the upright position. 2. We have assessed the effect of controlled respiration at different rates (10, 15, 20 breaths/min or 0.17, 0.25 and 0.33 Hz), while supine and standing, on power spectral analysis of heart rate and blood pressure variability in 11 patients with heart failure and 10 normal subjects. 3. Heart rate variance and low-frequency power (normalized units) were reduced in patients with heart failure (absent in six). During controlled breathing while supine, the power of the high-frequency component was significantly greater at 10 breaths/min than at 20 breaths/min in patients with heart failure, whether expressed in absolute units (P = 0.005) or percentage of total power (P = 0.03). 4. On standing, controlled breathing in patients with heart failure produced less change in high-frequency power (P = 0.054), but the low-frequency/high-frequency ratio at lower respiratory rates was reduced (P = 0.05). In normal subjects, as expected, respiratory rate had a highly significant effect on high-frequency power. Also, in normal subjects there was the expected increase in heart rate low-frequency power (P = 0.04) moving from supine to standing with an increase in the low-frequency/high-frequency ratio (P = 0.003), while in the patients with heart failure this was absent, reflecting blunted cardiovascular reflexes. 5. Systolic blood pressure low- and high-frequency components and their ratio were significantly affected by respiration (P < 0.03) and change in posture (P < 0.03) in both patients with heart failure and normal subjects, with a significant increase in the low-frequency/high-frequency ratio (P = 0.03) on standing in patients with heart failure, indicating that autonomic modulation of blood pressure is still operating in heart failure. 6. Thus, respiratory rate and changes in posture have a significant effect on measurements derived from spectral analysis of heart rate and blood pressure variability. Studies that use power spectral analysis as a measure of sympatho-vagal balance should control for these variables.

Adult↗

Fronto-occipital EEG power gradients in human sleep.

The brain topography of power spectra along the antero-posterior (A-P) axis was studied in the all-night human sleep EEG. Spectra (0.25 - 25.0 Hz) were computed for an anterior (A; F3-C3), a middle (M; C3-P3) and a posterior (P; P3-O1) bipolar derivation, and the spectral gradients between two adjacent derivations were expressed by power ratios (A/M and M/P). At NREM-REM sleep transitions a power shift from A to M was present over almost the entire frequency range, while the direction of shifts between M and P differed between frequency bands. Within NREM sleep, frequency specific power gradients were present: In the low delta band power in both A (0.25 Hz bin) and P (0.25-1.0 Hz bins) was higher than in M. In the 4-9 Hz range the relation was A > M > P, and in the 15 - 25 Hz range power was largest in M. Power in the spindle frequency range was highest at 11.75 Hz in M, and at 13.5 - 13.75 Hz in A. Topographical differences were seen also in the temporal changes of power across and within NREM sleep episodes. Whereas NREM sleep power in the 2-Hz bin was higher in A than in M in the first episode, this difference vanished in the course of the night. This result points to a specific involvement of frontal parts of the cortex in sleep homeostasis. The regional differences in sleep EEG spectra indicate that sleep is not only a global phenomenon but also a local brain process with a different regional involvement of neuronal populations.

Adult↗

High-velocity resistance training increases skeletal muscle peak power in older women.

OBJECTIVES: Peak power declines more precipitously than strength with advancing age and is a reliable measure of impairment and a strong predictor of functional performance. We tested the hypothesis that a high-velocity resistance-training program (HI) would increase muscle power more than a traditional low-velocity resistance-training program (LO). DESIGN: Randomized controlled trial. SETTING: University-based human physiology laboratory. PARTICIPANTS: Thirty women with self-reported dis-ability (aged 73 + 1, body mass index 30.1 + 1.1 kg/mn). INTERVENTION: We conducted a randomized trial comparing changes in skeletal muscle power and strength after 16 weeks of HI or LO. Training was performed three times per week, and subjects completed three sets (8-10 repetitions) of leg press (LP) and knee extension (KE) exercises at 70% of the one-repetition maximum (IRM). MEASUREMENTS: One-repetition maximum (1 RM) and peak power for KE and LP. RESULTS: LP and KE relative training force and total work were similar between groups (P > .05). However, HI generated significantly higher power during training sessions than LO for LP (3.7-fold greater, P < .001) and KE (2.1-fold greater, P < .001). Although LP and KE 1RM muscle strength increased similarly in both groups asa result of the training (P < .001), LP peak power increased significantly more in HI than in LO (267 W vs 139 W, P < .001). Furthermore, HI resulted in a significantly greater improvement in LP power at 40%, 50%, 60%,70%, 80%, and 90% of the 1 RM than did LO (P <.05). CONCLUSIONS: HI improved 1RM strength similarly and was more effective in improving peak power than was traditional LO in older women. Improvements in lower extremity peak power may exert a greater influence on age-associated reductions in physical functioning than other exercise interventions.

Aged↗

[3D vascular imaging with power mode in planning and controlling percutaneously implanted abdominal aortic stent grafts].

PURPOSE: Evaluation of the reliability of vascular ultrasound with power mode and 3D-power mode for preinterventional planning before endovascular treatment of abdominal aortic aneurysms and postoperative follow-up after endografting. MATERIAL AND METHOD: A new real-time 3D technique with power mode flow imaging was used in a prospective study of 75 patients with infrarenal aortic aneurysms, in 25 cases before and in 50 cases after stentgraft implantation. The results of vascular ultrasound with color-coded duplex sonography (CCDS), power mode and 3D power mode were compared with CTA and DSA in all cases. RESULTS: Only the length and diameter of the aneurysm could be reliably measured by sonography. Additional 3D reconstructions could show flow parameters in the aneurysm more clearly, but imaging of the proximal and distal anchoring zone was only achieved insufficiently. After stentgraft implantation, possible complications like thrombus formation in the graft (4/50) and endoleaks (15/50) were clearly seen by power sonography. 9 anchoring leaks and 6 side-branch endoleaks were found. 3D power mode made localizing and imaging of aneurysm reperfusion easier. Detection of the origin of side-branch endoleaks was achieved only by DSA. Stent frame fractures (4/50) were difficult to see by ultrasound. CONCLUSIONS: Vascular ultrasound with power mode and 3D power mode makes the imaging of complications after endoaortic stentgraft implantation like endoluminal thrombus formation or endoleaks and the documentation of aneurysm reperfusion easier compared to CCDS. 3D reconstructions show the dimensions of the aneurysm but are not able to substitute CTA and DSA with measuring catheter for preinterventional planning.

Aged↗

Aerobic and anaerobic power characteristics of competitive cyclists in the United States Cycling Federation.

The purpose of this study was to characterize the aerobic and anaerobic capabilities of United States Cycling Federation cyclists in different categories. To determine aerobic and anaerobic power, 38 competitive road cyclists (32 males, 6 females) performed a VO2max test and a Wingate anaerobic test, respectively. Male cyclists in category II had the highest VO2max, both in absolute and relative terms. Their VO2max was 6% and 10% higher than category III and IV cyclists, respectively (4.98 +/- 0.14 vs 4.72 +/- 0.15 vs 4.54 +/- 0.12 l/min). A significant difference existed between category II and IV male cyclists (p < 0.05). VO2max for female cyclists (3.37 +/- 0.13 l/min) was significantly (p < 0.05) lower than those for males. The Wingate anaerobic test revealed that male cyclists in category II also had the highest anaerobic power output. The peak power output in category II, III and IV was 13.86 +/- 0.23, 13.55 +/- 0.25, and 12.80 +/- 0.41 W/kg, respectively. The mean power output in category II, III, and IV was 11.22 +/- 0.18, 11.06 +/- 0.15, and 10.40 +/- 0.30 W/kg, respectively. The difference in the mean power output between category II and IV was significant (p < 0.05). Female cyclists recorded significantly less peak and mean power output than their male counterparts (p < 0.05). However, when expressed relative to lean body mass, anaerobic power was similar for both sexes. No inter-correlation was found in any measurement between the aerobic and anaerobic power values. On the whole, category II male cyclists were characterized by higher aerobic and anaerobic power outputs.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Factors affecting anaerobic power output in the Margaria-Kalamen test.

The purpose of this study was to determine the effect of three approach distances and two vertical ascent methods on approach velocity, vertical velocity and power output of the Margaria-Kalamen test. Male (n = 43) and female (n = 53) university students were tested using a traditional and a modified (ramp) Margaria-Kalamen test with approaches of 2, 6 and 10m. The average of five trials for each approach distance was used to calculate anaerobic power. Males averaged 14.0% greater approach velocity, 28.8% greater vertical velocity and 41.1% greater power output than females, regardless of approach distance or vertical ascent method. Anaerobic power output was not significantly different between the sexes for any method when the effects of the percentage of fat and lean body mass were removed by the covariance technique. The 2m approach produced significantly slower approach velocity, vertical velocity and power output than the other approaches. The ramp method resulted in significantly greater approach velocity (11.5%), vertical velocity (9.6%) and anaerobic power output (9.4%) than the stair method. Males averaged 8.4% higher power output using the ramp, while females averaged 11.0% higher than the conventional stair method. Females appeared to benefit more than males from using a ramp in the anaerobic power test. Anaerobic power measurement from the Margaria-Kalamen method can be maximized using a ramp method.

Adult↗

Power motivation, stress and physical illness.

College students reporting a large number of life change events in the past six months also reported significantly more frequent and more severe instances of physical illness and more affective symptoms in the same time period. These relationships, however, were modified in an interesting way by type of life change and by individual differences. Life change events were classified as involving power, affiliative or other stresses. Individuals scoring high in the need for Power (n Power), in inhibition, and in the number of power stresses (HHH subjects), reported more severe physical illness and affective symptoms than all other subjects or, in particular, subjects low in n Power, power stress and inhibition (LLL subjects). Individuals scoring high in Power and high in either inhibition or power stress also reported significantly more severe physical illness than other subjects. Among subjects high in inhibition, affiliative stress in combination with high n Power was associated with more severe physical illness, but, among subjects low in inhibition, affiliative stress in combination with high n Affiliation was associated with more physical illness. Affiliative stress was unrelated to affective symptoms. Other stress was unrelated either alone or in combination with other variable to physical illness or affective symptoms. The findings are interpreted as consistent with the hypothesis that subjects in the HHH category compared with other subjects are characterized by chronically high sympathetic activity which has immunosuppressive effects, making them more illness prone.

Affective Symptoms↗

Bilateral arm power imbalance in swim bench exercise to exhaustion.

We examined the supposition that swimmers may exhibit an imbalance in bilateral arm power output during simulated swimming exercise. Ten competitive front crawl swimmers (5 males, 5 females; age 20.5+/-2.3 years; height 1.74+/-0.09 m; body mass 72.0+/-16.7 kg; 400 m freestyle swim time 278+/-20.5 s; mean +/- s) performed four incremental (10 W x min(-1)) swim ramp tests on a computer-interfaced biokinetic swim bench ergometer. External power output from each arm was measured continuously to exhaustion. The results showed that, throughout the course of the simulated swim, external power output clearly favoured the left arm (F1,9 = 12.5, P= 0.006). This was especially evident in the final 30 s to exhaustion, when 54.0+/-3.87% of external power output was derived from the left arm versus 46.0+/-3.87% from the right arm. The disparity in external power output was further highlighted when the participants were grouped into unilateral and bilateral breathers. Unilateral breathers (n = 5) produced 57.1+/-2.62% of external power output from the left armversus 42.9+/-2.62% from the right arm (P= 0.001). Bilateral breathers (n = 5) exhibited a more balanced external power output of 51.0+/-1.82% from the left arm and 49.0+/-1.82% from the right arm (P = 0.177). Evidence of power imbalance in the simulated swimming stroke may have important implications for optimizing swim performance. The observed power imbalance may be reduced when a bilateral breathing technique is adopted.

Adult↗