PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “RADIATION PROTECTION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

[Non-ionizing radiation protection in medicine].

Non-ionizing radiation is extensively used in medicine for diagnostic and therapeutic purposes. Health risks from exposure to different sources of non-ionizing radiation are still not well known. High exposure to non-ionizing radiation produces acute effects on sensitive organs, mostly depending on radiation intensity, frequency and exposure duration. Prolonged low-level occupational exposure may also be hazardous. It is therefore necessary for the medical personnel to be aware of their occupational risk and to know how to apply protective measures in order to protect own health as well as that of the patients.

Health Personnel↗

[Status of radiation protection courses for physicians--plea for a change in paradigm].

The purpose of this study was to evaluate the acceptance of the statutory course of radiation protection, which is attended by physicians. As a first step towards problem based quality management, an anonymous questionnaire was used to assess the participants' opinions. The present methods in teaching, practice-orientation of the educational objectives, the prize and efficiency of the course were judged poor. Neither valid indicators of quality nor a quality management of the course exists. Facing the status quo and future demands within the medical community and society there is a serious need for reshaping radiology. It is emphasized that instead of marginal corrections only a strategic and fundamental approach to a paradigmatic reorganization will meet success.

Attitude of Health Personnel↗

Difficulties encountered with some intermediate-atomic-number radiation-protection dosimeters irradiated on-phantom in low-energy photon beams.

During a measurement-assurance study done with a particular type of radiation-protection dosimeter, we obtained unexpectedly poor results when several of the dosimeters were irradiated simultaneously on-phantom in a low-energy bremsstrahlung beam. The dosimeters incorporated low- and intermediate-atomic-number (Z) thermoluminescence dosimeter elements with the intermediate-Z elements under Pb filters. The response of the low-Z elements was in good agreement with the predicted response regardless of dosimeter location on the phantom, while agreement for the intermediate-Z elements was poor for some locations not coinciding with the phantom center. We have since studied the behavior of this dosimeter type and of four other types in detail by irradiating them, one at a time, on- and off-phantom, with their geometric centers displaced up to 10 cm along the vertical and horizontal axes through the center of the beam cross section. Two low-energy bremsstrahlung beams and a 137Cs gamma-ray beam were used. Variation of response to low-energy photons with on-phantom location was observed to some degree in all intermediate-Z dosimeter elements covered with high-Z filters. The reason for the observed dependence of response upon on-phantom location seems to be insufficient side shielding against phantom and filter albedo, as proved in one case, in which added shielding removed this dependence for the element immediately adjacent to the added shield. Since the effective dose equivalent to the human body is lower for lateral incidence of low-energy photons than for the same photons incident from the front or back, dosimeters incorporating high-Z filters without side shielding (and thus expected to exhibit the phenomenon) do not lend themselves to the determination of the effective dose equivalent or any quantity proportional to it by currently employed methods. A detailed study of the angular dependence of dosimeter response performed on a suitable phantom should aid in eliminating such inadequate dosimeters from practical use.

Calibration↗

ALARA and an integrated approach to radiation protection.

Exposures of individuals to ionizing radiation have been restricted for many years by a number of guidelines and rules developed by various advisory and regulatory groups. Accompanying these restrictions has been an evolving principle that exposures to individuals and groups should be kept "as low as reasonably achievable" (ALARA), consistent with provision of the benefits of radiation use to society. Although the ALARA concept is a laudable goal in principle, its implementation in a clinical facility has not been a straightforward process. Problems of implementing ALARA have been confounded further by the efforts of regulatory agencies to incorporate the ALARA concept into regulations governing radiation exposures. To facilitate the implementation of ALARA as a workable construct in a clinical facility, guidelines are needed for its application to both individual and collective exposures to radiation. The provision of such guidelines, including action and inaction levels for both individual and collective exposures, are presented here.

Dose-Response Relationship, Radiation↗

Leveraging bioinformatics approaches for drug repositioning in space radiation protection.

The health effects of space radiation, primarily Galactic Cosmic Rays (GCRs), on humans remain largely unknown, with potential cardiovascular consequences posing a significant threat to astronauts on long-duration spaceflight missions. Currently, there are no established pharmacological countermeasures for GCR exposure. Drug repositioning offers a promising strategy to accelerate pharmaceutical research in space medicine. This study leverages existing bioinformatics techniques to identify and prioritize potential drug candidates associated with proteomic perturbations following simulated GCR exposure using previously published murine cardiac proteomic data. A protein-protein interaction (PPI) network was constructed using the top differentially expressed proteins (DEPs) from murine heart tissue following exposure to 5-ion GCRs as seed nodes, focusing on experimentally supported interactions. Network topology, Markov clustering, and functional enrichment analyses were used to characterize biologically relevant proteins and pathways. Drug-protein interactions were predicted using Drugst.One and mapped to PPI clusters of interest to identify candidate drugs. Selected drug-macromolecule interactions were further explored using CB-Dock2 molecular docking and short-duration molecular dynamics simulations as hypothesis-generating structural assessments. Analysis of a key PPI network cluster consisting of several ATP synthase proteins identified 23 unique drug candidates. These analyses demonstrate a systematic approach for leveraging bioinformatics techniques to identify candidate molecular targets and generate pharmacological hypotheses in the context of space radiation countermeasures. Ultimately, this strategy introduces a hypothesis-generating framework for the prioritization of potential drug candidates for future computational characterization and experimental investigation against spaceflight stressors.

Animals↗

On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levels.

The possibility of using the specific responses of the high temperature Peaks 6 and 7 and Peaks 4 and 5 to different LET radiations was mentioned in the past mainly for very high doses. The applicability of the two regions method for thermal neutrons--gamma ray mixed field dosimetry was investigated by analysing the response of LiF:Mg,Ti dosemeters irradiated to different ratios of thermal neutrons and gamma rays at radiation protection dose levels encountered in routine work conditions, up to approximately 50 mSv. The Region of Interest method was used to define the areas of the Peaks 4 + 5 and 6 + 7. We found that a simple algorithm can be used to determine with good accuracy the separate contributions of neutron and gamma doses.

Computer Simulation↗

[Radiation protection in the operation of accelerator and plasma equipment].

Relatively great problems of radioprotection can be caused by accelerator units, above all in the field of science, because all kinds of ionizing radiation and radioactive substances can be produced in all states of aggregation. Furthermore, activities with relatively long half-lives are induced by high particle streams with energies beyond the thresholds of many nuclear reactions, so that the conditions of a control zone, even of a prohibited zone exist at many points after having switched off the accelerator. Not all of these radioprotective problems can be solved by constructive or technical measures. A sufficient skill of the persons responsible for radioprotection is very important in this connection. Efficient radioprotective measures are only possible by a close cooperation between the radiation protection officer, the competent authority, and the expert.

Germany, West↗