PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Software”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Quantification of video-taped images in microcirculation research using inexpensive imaging software (Adobe Photoshop).

BACKGROUND: Study end-points in microcirculation research are usually video-taped images rather than numeric computer print-outs. Analysis of these video-taped images for the quantification of microcirculatory parameters usually requires computer-based image analysis systems. Most software programs for image analysis are custom-made, expensive, and limited in their applicability to selected parameters and study end-points. METHODS AND RESULT: We demonstrate herein that an inexpensive, commercially available computer software (Adobe Photoshop), run on a Macintosh G3 computer with inbuilt graphic capture board provides versatile, easy to use tools for the quantification of digitized video images. Using images obtained by intravital fluorescence microscopy from the pre- and postischemic muscle microcirculation in the skinfold chamber model in hamsters, Photoshop allows simple and rapid quantification (i) of microvessel diameters, (ii) of the functional capillary density and (iii) of postischemic leakage of FITC-labeled high molecular weight dextran from postcapillary venules. We present evidence of the technical accuracy of the software tools and of a high degree of interobserver reliability. CONCLUSION: Inexpensive commercially available imaging programs (i.e., Adobe Photoshop) provide versatile tools for image analysis with a wide range of potential applications in microcirculation research.

Animals↗

Specialized spring design in segmented edgewise orthodontics: further verification of dedicated software.

A software program for use in the investigation of specialized springs used in the segmented arch technique has previously been developed and an example of its clinical application has been shown. The purpose of this study was to further assess the reliability of the software in 4 tests using T-loop springs. A numerical simulation of a determined experimental condition relative to a T-loop spring was carried out in each test. Numerical and experimental results were compared, and the precision of the analytical tool was assessed relative to a variety of parameters of the spring. Since the comparison between numerical and experimental results showed good agreement along the entire range of activation of the spring, the reliability of the software is sufficient for the clinical purposes of the segmented arch technique.

Computer Simulation↗

Open source software for experiment design and control.

The purpose of this paper is to describe a software package that can be used for performing such routine tasks as controlling listening experiments (e.g., simple labeling, discrimination, sentence intelligibility, and magnitude estimation), recording responses and response latencies, analyzing and plotting the results of those experiments, displaying instructions, and making scripted audio-recordings. The software runs under Windows and is controlled by creating text files that allow the experimenter to specify key features of the experiment such as the stimuli that are to be presented, the randomization scheme, interstimulus and intertrial intervals, the format of the output file, and the layout of response alternatives on the screen. Although the software was developed primarily with speech-perception and psychoacoustics research in mind, it has uses in other areas as well, such as written or auditory word recognition, written or auditory sentence processing, and visual perception.

Humans↗

Measurement of body surface area in atopic dermatitis using specific PC software (ScoradCard).

In skin diseases, evaluation of involved surface area is a crucial factor in grading the degree of severity. We examined the reliability of body surface area assessment and relative inter-observer and intra-observer variability using new software (ScoraCard), specifically designed to evaluate automatically the extension of the involved area in the SCORAD index. Twenty pediatricians, untrained in the evaluation of skin disease, estimated the percentage of surface area involved in photo-tests of two children with artificial well-delimited lesions, at first by sight and then through software. As "gold standard" the exact amount of pixels was counted for the whole body surface of the children, for the different body zones and for the painted artificial lesions, expressed as percentage of the respective zone. For photo 1, gold standard was 38.06% and median percentage was 43.44% (95% CI 40.7-46.21) by sight (p = 0.002) and 37.99% (95% CI 36.04-39.94) by ScoradCard (p = 0.79). For photo 2, gold standard was 27.84%, median percentage was 30.44% (95% CI 28.25-32.63) by sight (p = 0.047) and 27.8% (95% CI 26.55-29.04) by ScoradCard (p = 0.79). The level of agreement (kappa statistic), cumulative for the two photo tests, was 0.38 (fair agreement) by sight method and 0.67 (good agreement) by ScoradCard. Among the 10 pediatricians who repeated the computer aided evaluation 3 months apart, the intra-observer variability was not significantly different: the median percentage was 31.5% (95% CI 27.0-49.4) at time 0 and 29.0% (95% CI 26.7-47.2) 3 months later (p = 0.76). This new software could be a useful tool in evaluating skin lesions extension, minimizing inter- and intra-observer variability, which is an important goal in multi-centre studies.

Adolescent↗

Automated three-dimensional analysis of particle measurements using an optical profilometer and image analysis software.

The automated collection of topographic images from an optical profilometer coupled with existing image analysis software offers the unique ability to quantify three-dimensional particle morphology. Optional software available with most optical profilers permits automated collection of adjacent topographic images of particles dispersed onto a suitable substrate. Particles are recognized in the image as a set of continuous pixels with grey-level values above the grey level assigned to the substrate, whereas particle height or thickness is represented in the numerical differences between these grey levels. These images are loaded into remote image analysis software where macros automate image processing, and then distinguish particles for feature analysis, including standard two-dimensional measurements (e.g. projected area, length, width, aspect ratios) and third-dimensional measurements (e.g. maximum height, mean height). Feature measurements from each calibrated image are automatically added to cumulative databases and exported to a commercial spreadsheet or statistical program for further data processing and presentation. An example is given that demonstrates the superiority of quantitative three-dimensional measurements by optical profilometry and image analysis in comparison with conventional two-dimensional measurements for the characterization of pharmaceutical powders with plate-like particles.

Glass↗

Model of data structure and flow in general practice: a guide to evaluation of practice management software.

Despite its benefits, the computerisation of Australian general medical practices has been delayed, partly due to user concerns about the format of data dictated by available software and the portability of such data. This article proposes certain essential criteria for practice management software, which may provide a framework for its evaluation by users. A set of simple guidelines for database maintenance is also proposed. The author believes that users should become familiar with basic software architecture and drive the market to develop packages that conform to these minimal criteria.

Family Practice↗

Statistical process monitoring of WBC-reduced blood components assessed by two types of software.

BACKGROUND: Statistical process control is required for monitoring of the WBC-reduction process. This study focused on some factors that may influence the outcomes of statistical process monitoring, such as WBC-reduction technologies, the anticoagulant used, and WBC-counting technologies, by using two types of software. STUDY DESIGN AND METHODS: Data were collected from January to September 1999, before the implementation of universal WBC reduction. The effects of three major factors were investigated: methods of preparation, the addition of EDTA to the sample, and the WBC-counting technologies used (microvolume fluorimetry, flow cytometry, and Nageotte chamber). The WBC-reduction process capability was assessed by two types of software, EZQC (Gambro BCT) and NWA (Northwest Analytical). In addition, the differences between various sets of results were compared by the t test or ANOVA. RESULTS: There was no statistical difference (at the 0.05 level of significance) in WBC content when the three types of platelets in citrate samples were compared with EDTA samples. In general, the Nageotte chamber appeared to count the lowest, and microvolume fluorimetry appeared to count lower than flow cytometry. There were minor but significant methodologic differences between the software packages. However, these differences had negligible effects on the percentage of conforming components at both <1 x 10(6) and <5 x 10(6) WBCs per unit. CONCLUSION: Only the counting technologies were sufficiently different to warrant consideration. This difference may make unacceptable the interchange of results obtained from various counting methods.

Anticoagulants↗

[New design concept to improve medical application software].

Up to now, there has been no software model available that adequately addresses the growing importance of flexibility in using different information tools. Based on Java, Jini technology provides distributed and therefore robust software architecture. In case of an application crash, Jini is able to minimize the damage by adding functions that reverse the effects of the crash. Owing to increasing user mobility, it is necessary to be able to receive location-independent information. The growing use of powerful telecommunications suggests the application of 'wireless application protocol' (WAP) mobile telephones also for medical purposes. This paper presents the application of these new software trends (Jini and wireless application protocol).

Database Management Systems↗

Evolving a lingua franca and associated software infrastructure for computational systems biology: the Systems Biology Markup Language (SBML) project.

Biologists are increasingly recognising that computational modelling is crucial for making sense of the vast quantities of complex experimental data that are now being collected. The systems biology field needs agreed-upon information standards if models are to be shared, evaluated and developed cooperatively. Over the last four years, our team has been developing the Systems Biology Markup Language (SBML) in collaboration with an international community of modellers and software developers. SBML has become a de facto standard format for representing formal, quantitative and qualitative models at the level of biochemical reactions and regulatory networks. In this article, we summarise the current and upcoming versions of SBML and our efforts at developing software infrastructure for supporting and broadening its use. We also provide a brief overview of the many SBML-compatible software tools available today.

Biochemistry↗

Follow-up study of treatment of orbital floor fractures: relation of clinical data and software-based CT-analysis.

This retrospective study quantifies isolated orbital floor fractures using software-based CT-analysis and compares the clinical outcome across surgical and non-surgical treatment groups. Depending on the surgeon's interpretation of the clinical and radiological appearance, 10 fractures were treated non-surgically and 20 fractures surgically, either with antral balloon catheter alone or in combination with an orbital implant. Ophthalmologic findings were evaluated until 12 weeks after injury. Fracture area, and volume of displaced tissue (VDT) were assessed by software-based CT-analysis. VDT was marginally significantly smaller in non-surgically than in surgically-treated patients (P=0.08). Ophthalmologic findings improved in all groups during follow-up and no statistical difference was found between the groups. Diplopia remained moderate in three patients with balloon catheter alone, and minimal in four patients in both surgical groups. In one patient with non-surgical treatment, diplopia remained minimal after 12 weeks. Although CT-analysis revealed no significant difference between both surgical groups, patients treated with balloon catheter alone presented more diplopia after 12 weeks. Using balloon catheters for fracture repair a combined approach should be performed when large fractures involve the orbital floor to achieve sufficient reduction of orbital content and placement of an orbital implant. Software-based CT-analysis is helpful for objective interpretation in managing of orbital fractures.

Adult↗

Comparison of an automated thrombolytic predictive instrument to both diagnostic software and an expert cardiologist for diagnosis of an ST elevation acute myocardial infarction.

Because the electrocardiograms (ECGs) of patients with symptoms suggesting an acute thrombotic coronary occlusion are typically read by physicians relatively inexperienced in this skill, it is important to develop automated decision support. A Thrombolytic Predictive Instrument (TPI) is now available along with the standard diagnostic software in a commercially available electrocardiograph. This study evaluates the performance of the predictive software in comparison to both an expert cardiologist and standard diagnostic software. True sensitivity and specificity cannot be determined because acute coronary angiography was not performed. The specificities determined by this study were excellent (98% and 99%), and the sensitivities were very good (72% and 78%). These results that the TPI will be only rarely applied to patients who do not indeed have an acute coronary thrombosis. However, the reasons for even this small number of presumably falsely TPI positive patients should be determined and analyzed. It is unlikely that alterations of the thresholds for TPI activation will significantly improve on this very good level of sensitivity, without prohibitively decreasing specificity.

Clinical Competence↗

[Fully automatic detection and quantification of emphysema on thin section MD-CT of the chest by a new and dedicated software].

PURPOSE: Introduction of a novel software tool (YACTA -- yet another CT analyzer) for detection and quantification of pulmonary emphysema in thin-slice chest MDCT data sets. MATERIALS AND METHODS: Consisting of grey-level threshold-based algorithms (e. g., region-growing), expert rules and morphological image postprocessing YACTA segments the tracheobronchial tree prior to the detection and quantification of pulmonary emphysema. In addition to general parameters, such as the mean lung density (MLD) and the emphysema index (EI -- also described as pixel index PI), the previously described bullae index (BI) is transformed into a three-dimensional parameter for a morphological description of emphysema. A first evaluation of chest MDCT data sets of 11 patients was performed as well as a comparison of MLD, lung volume (LV), emphysema volume (EV) and PI calculated with two established commercial tools of Siemens Medical Solutions (Volume and Pulmo). Furthermore, the BI was calculated with YACTA. RESULTS: YACTA processed the image data without manual interaction and demonstrated more user-comfort than Volume and Pulmo software, which require manual correction especially for lung segmentation at the hilar regions to separate central airways from lung parenchyma. MLD, LV, and EV values calculated with YACTA were systematically higher (Pulmo: + 50 HU/+ 597 ml/+ 159 ml; Volume: + 32 HU/+ 110 ml/+ 155 ml). Different segmentation algorithms are responsible for this: YACTA includes areas not assessed by mere threshold-based techniques. Constantly lowered LV values of Pulmo are caused by a missing dilatation algorithm. The error correction as a special feature of YACTA results in increased emphysema volumes and indices. The segmentation of the tracheobronchial tree lowers the part of airways falsely classified as emphysema. CONCLUSION: The new developed software shows higher user comfort as established by semi-automated tools. RESULTS: of LV, EV, MLD and PI are comparable or moderately different. Automatic calculation of a BI is possible, providing information about bullous morphology of pulmonary emphysema. Further studies are necessary to correlate data with clinical or pathological parameters.

Adult↗

[Evaluation of a new software tool for the automatic volume calculation of hepatic tumors. First results].

PURPOSE: Computed tomography has become the preferred method in detecting liver carcinomas. The introduction of spiral CT added volumetric assessment of intrahepatic tumors, which was unattainable in the clinical routine with incremental CT due to complex planimetric revisions and excessive computing time. In an ongoing clinical study, a new software tool was tested for the automatic detection of tumor volume and the time needed for this procedure. MATERIALS AND METHODS: We analyzed patients suffering from hepatocellular carcinoma (HCC). All patients underwent treatment with repeated transcatheter chemoembolization of the hepatic arteria. The volumes of the HCC lesions detected in CT were measured with the new software tool in HepaVison (MeVis, Germany). The results were compared with manual planimetric calculation of the volume performed by three independent radiologists. RESULTS: Our first results in 16 patients show a correlation between the automatically and the manually calculated volumes (up to a difference of 2 ml) of 96.8 %. While the manual method of analyzing the volume of a lesion requires 2.5 minutes on average, the automatic method merely requires about 30 seconds of user interaction time. CONCLUSION: These preliminary results show a good correlation between automatic and manual calculations of the tumor volume. The new software tool requires less time for accurate determination of the tumor volume and can be applied in the daily clinical routine.

Algorithms↗

[Teleradiology according to the x-ray ordinance--exemplary application of the open source software SecTelMed].

PURPOSE: Establishing a teleradiology connection according to the Rontgenverordnung (RoV) between a peripheral hospital and a university clinic will contribute to improve the radiological emergency treatment on weekends, holidays and at night. It will also better the medical care for patients and help to lower the costs. MATERIALS AND METHODS: By using the open source software SecTelMed, the radiological picture is transferred via an internet-linked SSH communication server. The integration of the teleradiological data transfer into the actual workflow is attained by using the already existing PACS infrastructure. While its installation is still under construction, it is actually employed for transferring a patient's preliminary investigations and obtaining second opinions. RESULTS: The project proves a reliable and affordable teleradiology according with RoV by using open source software. The applied infrastructure ensures an unproblematical teleradiological treatment as well as a safe picture transfer for medical consulting (second opinion) even for large CT examinations of 1,000 pictures and more. CONCLUSION: The implementation of the technical requirements on teleradiology according with the Rontgenverordnung can be reliably attained by applying the open source software SecTelMed.

Computer Communication Networks↗

Three-dimensional endorectal ultrasound using a new freehand software program: results in 35 patients with rectal cancer.

BACKGROUND AND STUDY AIMS: This paper describes experience in the staging of rectal cancer using a new software program for three-dimensional endoscopic ultrasonography (EUS) that works without electromagnetic sensors and can be used even with electronic radial or linear rectal probes. MATERIALS AND METHODS: From May 2003 to March 2004, 35 three-dimensional endorectal ultrasound (ERUS) examinations were carried out using this program. The indication for ERUS was local staging of rectal cancer in all cases. The three-dimensional software imaging program forms part of a new ultrasound scanning system (Hitachi 6500 or 8000) and allows reconstruction of the two-dimensional EUS images in six different scans. RESULTS: Thirty-five rectal cancers were assessed using two-dimensional and three-dimensional EUS. Using two-dimensional imaging, it was not possible to assess precisely the degree of involvement of the mesorectum (more or less than 50%). No differences were evident with three-dimensional EUS for superficial tumors (T1 and T2N0), but in six of 15 patients classified as having T3N0 lesions, three-dimensional EUS revealed malignant lymph nodes, a finding that was confirmed surgically in five of the six cases. Three-dimensional EUS also made it possible to assess the degree of infiltration of the mesorectum precisely in all cases, demonstrating complete invasion of the mesorectum in eight cases. These findings were confirmed in all cases by the surgical data. Two-dimensional EUS correctly assessed 25 of the 35 rectal tumors (71.4%) in relation to the T and N classifications, and three-dimensional EUS increased this figure to 31 correct evaluations out of 35 (88.6%). CONCLUSION: Three-dimensional ERUS is easy to carry out using this new software program. There is no need for an external sensor mounted at the tip of the probe, and manipulation of the rectal probe is facilitated. Three-dimensional ERUS can be carried out using linear and radial electronic probes with the same ultrasound equipment. Three-dimensional ERUS allows more precise staging of lesions and better definition of the mesorectal margins, and this has a direct impact on therapeutic decision-making in patients with rectal cancer.

Endosonography↗

[Apple-Macintosh compatible software for documentation, management and evaluation of ultrasound findings in obstetrics].

The advantage of using a computer to automate routine calculations and print out charts of the obstetrical ultrasound examination is obvious. This report describes a software designed to simplify the documentation and analysis of ultrasound data in obstetrics. The system is easy to use, even for persons with little computer knowledge. The programme was written in FoxBase+/Mac (Fox Software, Inc., USA). FoxBase+/Mac takes full advantage of the easy-to-learn, easy-to-use Macintosh interface and is also very fast. Another advantage of this software is that it can be used in teaching. Non-experienced examinators can double-check the correctness of their scanning planes by observing the ultrasound pictures with the markers indicating the right measurement sites and the lists of standard values of biometrical parameters for the corresponding gestational age on the screen. In routine obstetrical ultrasound examinations it takes less than 5 min to enter the foetal biometry data and print out reports. These reports are informative and easy to interpret.

Female↗

A software suite for the generation and comparison of peptide arrays from sets of data collected by liquid chromatography-mass spectrometry.

There is an increasing interest in the quantitative proteomic measurement of the protein contents of substantially similar biological samples, e.g. for the analysis of cellular response to perturbations over time or for the discovery of protein biomarkers from clinical samples. Technical limitations of current proteomic platforms such as limited reproducibility and low throughput make this a challenging task. A new LC-MS-based platform is able to generate complex peptide patterns from the analysis of proteolyzed protein samples at high throughput and represents a promising approach for quantitative proteomics. A crucial component of the LC-MS approach is the accurate evaluation of the abundance of detected peptides over many samples and the identification of peptide features that can stratify samples with respect to their genetic, physiological, or environmental origins. We present here a new software suite, SpecArray, that generates a peptide versus sample array from a set of LC-MS data. A peptide array stores the relative abundance of thousands of peptide features in many samples and is in a format identical to that of a gene expression microarray. A peptide array can be subjected to an unsupervised clustering analysis to stratify samples or to a discriminant analysis to identify discriminatory peptide features. We applied the SpecArray to analyze two sets of LC-MS data: one was from four repeat LC-MS analyses of the same glycopeptide sample, and another was from LC-MS analysis of serum samples of five male and five female mice. We demonstrate through these two study cases that the SpecArray software suite can serve as an effective software platform in the LC-MS approach for quantitative proteomics.

Amino Acid Sequence↗

Healthcare information systems: analysis of healthcare software.

The need to manage medical information in healthcare delivery requires that information technology be optimized in diagnosing disease; in planning and administering treatment; and in monitoring patient outcomes, services, and costs. The goals of this article are twofold: (1) to identify healthcare-specific software that addresses specific parameters set forth by the World Health Organization (WHO) for healthcare information systems and (2) to identify issues that managers should keep in mind when choosing an integrated information systems software package. For our analysis, we gathered, through Internet research, information about more than 400 software products from more than 200 companies.

Decision Making, Organizational↗