PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tooth Apex”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Apical anatomy in mesial and mesiobuccal roots of permanent first molars.

The purpose of this in vitro study was to investigate the canal configuration types, and the prevalence and location of anatomical variations in the mesiobuccal (MB) and mesial roots of permanent maxillary and mandibular first molars after instrumentation. The number and the type of canals were determined before instrumentation using conventional methods. All root canals from the 47 MB roots and 42 mesial roots were then instrumented to size #30 with ProFile .04 taper rotary instruments in a crown-down method and then filled with a single gutta-percha cone and sealer. Transverse 1 mm-thick cross-sections at 2, 3, 4, and 5 mm from the apex were obtained, stained and examined using a stereomicroscope. The canal configuration types and the prevalence and location of isthmi and accessory canals in roots with two canals were evaluated. The prevalence of two canals was 80.8% in the maxillary MB roots and 95.2% in the mandibular mesial roots. There were six types of canal configurations in the instrumented root apices. The prevalence of anatomical variations was highest at the apical 4 mm level, and was more frequent in mandibular first molars, and in roots with Weine type III canal. chi test showed that the prevalence of the anatomical variations was statistically higher in the maxillary MB roots with Weine type III canals than in those with Weine type II canals (p < 0.05). Different canal configurations were often found at different levels in the same root. The results indicate that anatomical variations persist following instrumentation of roots with two canals in first molars. These anatomical variations should be considered during surgical or nonsurgical endodontic procedures of the permanent first molars.

Chi-Square Distribution↗

Effect of customization of master gutta-percha cone on apical control of root filling using different techniques: an ex vivo study.

AIMS: (i) To compare the prevalence of extrusion of root filling material when placed using different root filling techniques, with or without customization of the master gutta-percha (GP) cone; and (ii) to investigate the effects of some factors influencing root filling extrusion and presence of voids. METHODOLOGY: A total of 180 roots were selected, prepared and randomly allocated to three groups. Five general dental practitioners performed the root fillings; each filled one group of roots (n = 60) using each of three techniques; 'cold lateral compaction' (n = 20), 'warm vertical compaction' (n = 20) and 'continuous-wave' (n = 20) techniques. For each obturation technique, the master GP cone was customized using chloroform in 10 samples. Two groups of the roots were recycled to allow all five operators to fulfill their remit. Two observers, blind to operator and obturation technique, examined the radiographs (master apical file, post-obturation) to determine the presence of root filling extrusion and voids within the apical 5 mm, independently. Root filling extrusion was also confirmed by direct inspection of the root apex after obturation. The data were analysed using logistic regression models. RESULTS: A total of 300 root fillings were performed; nine were excluded from the analysis. Most of the root fillings (80%, n = 233) were placed within 0.5 mm of the working length; only 20% (n = 58) were placed >0.5 mm beyond the working length. The odds of prevalence of extrusion (>0.5 mm) were significantly reduced by about 50% when cold lateral compaction or customization of GP were used. One operator produced 2.5 times more extruded root fillings than others. Curvature & length of root canal, apical size of prepared canal, as well as operator's preferred obturation technique had no significant influence on the prevalence of extrusion. Customization of GP was the sole factor to significantly reduce the prevalence of voids within the apical 5 mm of working length. CONCLUSIONS: Root filling extrusion was significantly influenced by 'operator' and was reduced by cold lateral compaction and customization of the master cone. Customization of master cone was the only factor that reduced voids apically.

Clinical Competence↗

The evaluation of removal of calcium hydroxide paste from an artificial standardized groove in the apical root canal using different irrigation methodologies.

AIM: To evaluate the capacity to remove a calcium hydroxide (Ca(OH)2) paste from the root canal and to evaluate the efficacy of Ca(OH)2 removal during passive ultrasonic irrigation using either sodium hypochlorite (NaOCl) or water as an irrigant. METHODOLOGY: Sixteen mandibular premolars were used. Each root was prepared to the apical foramen using GT instruments of size 30, 0.06 taper. Each root was split longitudinally. In one half of the root, a groove was cut in the canal wall 2-6 mm from the apex which was then filled with a Ca(OH)2 paste. Subsequently the roots were reassembled. In group 1 (n = 16), the teeth were ultrasonically irrigated using 50 mL 2.0% NaOCl as the irrigant. Group 2 (n = 16) was treated in the same manner as group 1, but using 50 mL water in place of the NaOCl. In group 3 (n = 16), the teeth were irrigated by syringe injection of 50 mL 2.0% NaOCl. The quantity of remaining Ca(OH)2 in the groove was scored and the data analysed with Kruskal-Wallis and Mann-Whitney tests. RESULTS: The difference in remaining Ca(OH)2 between all groups was statistically significant (P < 0.001). Group 1 had significantly lower scores than group 2 (P < 0.001) and group 3 (P = 0.002), but there was no significant difference between groups 2 and 3 (P = 0.765). CONCLUSIONS: Passive ultrasonic irrigation with 2% NaOCl was more effective in removing Ca(OH)2 paste from artificial root canal grooves than syringe delivery of 2% NaOCl or water as irrigant.

Calcium Hydroxide↗

Evaluation of different methods for the root-end cavity preparation.

OBJECTIVE: The dentinal walls of root-end cavities were examined for the presence of cracks and debris in correlation with the area of the root surfaces that remained after the resection. STUDY DESIGN: One hundred extracted single-rooted teeth were endodontically treated, mounted in acrylic resin blocks, and the apical 2 mm of the root-apex was resected. According to the resected root surface area the teeth were divided into 2 groups having large (>2 mm(2)) or small (<2 mm(2)) surface area. For retrograde cavity preparation 4 devices were used: slow-speed handpiece, diamond coated stainless steel ultrasonic tip, smooth stainless steel ultrasonic tips, and sonic diamond-coated tips. Teeth were examined under a videomicroscope for the presence of fractures, dentin chips, and gutta-percha remnants on cavity walls. Preparation time was also recorded. RESULTS: Preparation with smooth stainless steel ultrasonic tips produced few intradentin cracks. Dentin debris was more frequently seen in rotary preparations whereas gutta-percha remnants were seen mainly at ultrasonically prepared teeth. CONCLUSIONS: Sonic and ultrasonic devices produced cleaner, well-centered, and more conservative root-end cavities than the rotary instrumentation. Cracks do not correlate directly with the surface area of the root-end surfaces but rather with the type of retrotip used to prepare the root-end cavity.

Apicoectomy↗

A simple mounting model for consistent determination of the accuracy and repeatability of apex locators.

AIM: To develop a precise and simple mounting model (MM) for evaluating apex locators and to compare the repeatability of the MM with a conventional visual method (VM). METHODOLOGY: Electronic working length determination was performed in 32 maxillary central incisors using two methods: (i) the MM method and (ii) a conventional VM. The MM utilizes a micrometer to determine the distance travelled by the measuring file during working length determination. In the VM, the length of the measuring file (representing the working length) is determined visually using a caliper and a microscope at 6x magnification. Each measurement was repeated once. The repeatability of each method was evaluated by calculating the coefficient of repeatability. RESULTS: The coefficient of repeatability, which includes 95% of the differences between repeated measurements, was 0.04 mm for MM compared with 0.9 mm for VM. The measurement error of MM was significantly lower than VM (0.02 and 0.4 mm respectively). There was a statistically significant difference between the means of absolute difference in repeated measurements: MM 0.01 mm (95% confidence interval (CI): 0.01; 0.02 mm) compared with VM 0.4 mm (95% CI: 0.3; 0.5 mm). CONCLUSION: The new MM had superior repeatability in comparison with the conventional method where visual interpretation is a source of inaccurate measurement.

Electronics, Medical↗

Radiographic technical quality of root canal treatment performed by dental students at the Dental Teaching Center in Jordan.

OBJECTIVES: The objective of this study was to evaluate radiographically the technical standard of root canal treatment performed by undergraduate dental students at the Dental Teaching Center in Jordan. METHODS: A random sample of 8500 records of dental patients was examined. A total of 542 endodontically treated teeth with 912 roots were evaluated. Periapical radiographs were used to assess the technical quality of the root canal filling. The length of each root canal filling was categorized as acceptable, short and overfilled based on their relationship with the radiographic apex. Density and taper of filling was evaluated based on the presence of voids and the uniform tapering of the filling, respectively. Chi-square analysis was used to determine statistically significant differences between adequacy of root canal filling in each group of teeth according to its location, position and curvature. RESULTS: Sixty-one percent of roots had fillings of acceptable length, while 34.5% were short and 4.2% were overfilled. The root canal fillings of 47.4% were found to be adequate. Adequate fillings were found more in maxillary than mandibular teeth (P < 0.005), anterior compared to posterior teeth (P < 0.05) and in straight canals compared to curved canals (P < 0.001). CONCLUSION: The technical quality of root canal treatment performed by undergraduate dental students using step-back preparation and lateral condensation was found to be less than 50%. Review of the endodontic curriculum requirements, specialized clinical supervision and increasing the time of training at the preclinical and clinical levels should improve this quality.

Adolescent↗

Percentage of canals filled in apical cross sections - an in vitro study of seven obturation techniques.

AIM: To compare the apical density of several obturation techniques when used in palatal roots of extracted maxillary molars. METHODOLOGY: Seventy extracted molars were randomly divided into seven groups with 10 teeth each. The palatal root canals were instrumented to size 60 MAF, coated with Kerr's Pulp Canal Sealer, and obturated using one of seven techniques. The palatal roots were separated from the crowns, decalcified, and sectioned horizontally at 2 and 4 mm from the apex. The cross-sections were photographed through a microscope, the photos were analysed, and the amount of area in the canal that was obturated with gutta-percha was measured. The means for the 20 sections per group were calculated and the means were compared using mixed analysis of variance test. RESULTS: Simplifill used in accordance with the manufacturer's directions and Thermafil had the greatest mean obturated area, but neither were statistically better than mechanical lateral or warm vertical compaction (WVC; Schilder Technique). Simplifill as recommended and Thermafil were statistically better than cold lateral (P = 0.0210 and 0.0433, respectively), WVC (continuous wave) (P = 0.0006 and 0.0015), and the modified Simplifill group (P = 0.0010 and 0.0012). In addition, mechanical lateral and WVC (Schilder) had statistically more obturated area than WVC (continuous wave) (P = 0.0054 and 0.0073) and modified Simplifill (P = 0.0015 and 0.0016). Cold lateral and WVC (continuous wave) had significantly more obturated area than modified Simplifill (P = 0.0040 and 0.0087). CONCLUSIONS: Simplifill as recommended, Thermafil, mechanical lateral and WVC (Schilder) obturation techniques created more complete obturation using gutta-percha at the 2 and 4 mm levels than cold lateral, WVC (continuous wave), and Simplifill not used as directed.

Analysis of Variance↗

Histological changes induced by CO2 laser microprobe specially designed for root canal sterilization: in vivo study.

OBJECTIVE: Until now, no suitable delivery fiber has existed for CO2 laser endodontic radiation in the apical region, where it is most difficult to eliminate the pulp tissue using conventional methods. To overcome this problem, we have designed a microprobe that reaches closer to the apex, distributing the energy density to a smaller area of the root canal and thus favorably increasing the thermal effects. METHODS: A CO2 laser microprobe coupled onto a special hand piece was attached to the delivery fiber of a Sharplan 15-F CO2 laser. The study was conducted on 30 vital maxillary or mandibulary, central, lateral, or premolar teeth destined for extraction due to periodontal problems. Twenty were experimentally treated with pulsed CO2 laser delivered by this newly developed fiber after conventional root canal preparation. Temperature measured at three points on the root surface during laser treatment did not exceed 38 degrees C. Ten teeth represented the control group, in which only root canal preparation was performed in the conventional method. RESULTS: Histological examination of the laser-treated teeth showed coagulation necrosis and vacuolization of the remaining pulp tissue in the root canal periphery. Primary and secondary dentin appeared normal in all cases treated with 15-F CO2 laser. Gram stain and bacteriologic examination revealed complete sterilization. These results demonstrate the unique capabilities of this special microprobe in sterilization of the root canal, with no thermal damage to the surrounding tissue. CONCLUSIONS: The combination of classical root canal preparation with CO2 laser irradiation using this special microprobe before closing the canal can drastically change the quality of root canal fillings.

Bacteriological Techniques↗

In vitro evaluation of apical sealing in root apex treated with demineralization agents and retrofiled with mineral trioxide aggregate through marginal dye leakage.

The purpose of this study was to evaluate the apical seal in root apex treated with different demineralization agents and retrofilled with mineral trioxide aggregate (MTA) using marginal dye leakage. Fifty-six, human single-rooted teeth were instrumented, filled, resected and had retrofilling cavities prepared with ultrasonic tips. Demineralizing agents were applied before the apical cavities were retrofilled with Pro Root MTA. The specimens were assigned to 4 groups (n=14), as follows: group 1 (no demineralizing agent); group 2 (35% phosphoric acid, for 15 s); group 3 (17% EDTA solution, pH 7, for 3 min); and group 4 (24% EDTA gel, pH 7, for 4 min). The extension of dye (2% rhodamine B, at 37 degrees C, for 24 h) penetration was measured in millimeters using a stereomicroscope. Results were statistically analyzed by ANOVA and Tukey's test at 5% significance level. Among the experimental groups, the least extension of dye penetration was observed in group 1 (1.89 mm), followed by groups 2 (2.18 mm), 4 (2.54 mm) and 3 (2.64 mm). No statistically significant differences (p<0.05) were found in marginal microleakage among groups 1, 2 and 4 and groups 2, 3 and 4. Based on the results obtained in this study, it may be concluded that the application of demineralizing agents cannot be recommended when MTA is used in periradicular surgeries.

Aluminum Compounds↗

Assessment of morphological changes and permeability of apical dentin surfaces induced by Nd:Yag laser irradiation through retrograde cavity surfaces.

The purpose of this in vitro study was to observe the morphological changes and apical dye penetration at apical dentin surfaces induced by Nd:YAG laser irradiation at different power settings with and without a laser initiator. Seventy five single rooted human maxillary anterior teeth were used. Following the establishment of the working lengths, the root canals were enlarged with step-back technique. The apex of each root was resected 3 mm perpendicular to its long axis. Standard Class I cavities of 2 mm depth and 2 mm width were prepared. The teeth were randomly divided into five groups with fifteen teeth in each. In Group 1, the retrograde cavity preparations were lased with Nd:YAG laser at 2 W and those in Group 2 preparations were lased with Nd:YAG laser at 3.2 W. In Group 3, the retrograde cavity surfaces were lased with Nd:YAG laser at 2 W following the application of India ink. Group 4 was lased with the same settings of Group 2 after an absorbent cotton point soaked with India ink was inserted into the cut dentinal surfaces and the inner walls of the apical preparations. Group 5 served as control. Five teeth from each group were examined using scanning electron microscopy (SEM). The amounts of smear layer, debris, and recrystalized dentin present were assessed and scored. Retrograde cavities of ten teeth from each group were filled with amalgam to examine apical dye penetration. The teeth were immersed in 2% basic fuscin and kept for 48 hours. Dye penetration was evaluated by stereomicroscope at a magnification of X10. The results showed the usage of India ink with Nd:YAG laser enhanced the amount of melting and recrystalization of dentin and the radiation and initiator increased the leakage.

Analysis of Variance↗

An evaluation of the quality of root fillings in mandibular incisors and maxillary and mandibular canines using different methodologies.

OBJECTIVES: To evaluate the quality of root fillings in mandibular incisors and maxillary and mandibular canines using different methodologies of evaluation, namely radiographs, the fluid transport test and the percentage of gutta-percha (PGP), and to determine if a correlation occurs between the results of the different methodologies used. METHODS: One group of mandibular incisors with oval canals (n=20) and one group of maxillary and mandibular canines (n=20) were instrumented and obturated by cold lateral compaction using AH 26 as the sealer. The filled roots were bucco-lingually and mesio-distally radiographed. Using a scoring system, the quality of each root filling was radiographically evaluated, the higher the score the poorer the quality. Fluid transport along the root filling was then measured using a fluid transportation device. Each root was horizontally sectioned 4 and 6mm from the apex. Images of the cross-sections were taken, using a microscope and a digital camera. Images were scanned into a PC as TIFF images. Using a KS 100 Imaging system the canal area and the gutta-percha filled areas were measured. The percentage of gutta-percha filled areas was calculated. RESULTS: Considering the radiographic scores of the two different projections together the score was significantly higher for the mandibular incisors than for the canines (P=0.039). The radiographic score was significantly higher for the mesio-distal radiograph in comparison with the bucco-lingual radiograph (P=0.0001), for the canines as well as the incisors. Using only the bucco-lingual radiograph there was no significant difference between the mandibular incisors and the canines (P=0.992). The mandibular incisors displayed significantly more fluid transport than the canines (P=0.049). A significantly greater percentage of gutta-percha filled areas was found in the cross-sections of canines as compared to the cross-sections of mandibular incisors (P=0.000001). The correlation between the radiographic score of the mesio-distal radiograph and the PGP 4 and 6mm was significant (P=0.013). There was no significant correlation between the FT and the radiograph or the FT and the PGP. CONCLUSIONS: The quality of the root fillings in oval canal-mandibular incisors may be compromised.

Bismuth↗

The influence of volume, type of irrigant and flushing method on removing artificially placed dentine debris from the apical root canal during passive ultrasonic irrigation.

AIM: To determine the influence of volume, irrigant and method of flushing on the removal of artificially-placed dentine debris from the apical part of root canals during passive ultrasonic irrigation. METHODOLOGY: Access cavities were prepared in 15 canine teeth and their root canals instrumented to size 20, 0.10 taper. Each root was split longitudinally, forming two halves. A groove was cut in the canal wall 2-6 mm from the apex in each half which was then filled with dentine debris prior to the roots being reassembled. All canals were ultrasonically irrigated, using a size 15, 0.02 taper smooth wire to a length of 21 mm that was placed in the canal to the apical foramen. In group 1 the canal was flushed with a continuous flow of 50 mL 2% sodium hypochlorite (NaOCl). In group 2 the continuous flow was not used but the canal was flushed with 12 mL 2% NaOCl, at a rate of 2 mL 30 s-1 using a syringe. Group 3 was treated in the same way as group 2 but the canal was flushed with 6 mL 2% NaOCl, at a rate of 2 mL min-1. Group 4 was treated in the same way as group 1 but water was used as the irrigant. Before and after irrigation, images of the grooves were captured and stored. The quantity of dentine debris in the groove was evaluated. The differences in debris scores between the experimental groups were analysed with the Kruskal-Wallis test and the Mann-Whitney U-test. The level of significance was set at P=0.05. RESULTS: The difference between all groups was statistically significant (K-W test P<0.001). Groups 1, 2 and 3 differed significantly from group 4 (P<0.001); there was no significant difference between groups 1, 2 and 3 (P=0.550). CONCLUSIONS: Syringe delivery of 2% NaOCl (6 and 12 mL) was as effective as a continuous flow of 2% NaOCl (50 mL). Water was not effective in removing dentine debris from grooves in the apical portion of root canals.

Cuspid↗

In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece.

AIM: The aim of this study was to assess the clinical perfomance of a cordless handpiece with a built-in apex locator - the Tri Auto ZX - designed for root canal preparation with nickel-titanium rotary files. METHODOLOGY: Twenty-five human maxillary incisor and canine teeth scheduled for extraction with mature apices were selected for the study. Informed written consent was obtained from each patient before treatment. After administration of local anaesthesia, the teeth were isolated and the pulp cavities accessed. The Tri Auto ZX along with a size 15 K-file was used in its electronic apex locating function based on the manufacturer's recommendations. A periapical radiograph with the file at the electronically determined constriction was taken, the file removed and the measurement registered as the electronic length (EL). To test the auto reverse function, a size 20 ProFile.04 taper NiTi rotary instrument was mounted in the handpiece. The point for the auto apical reverse function was preset on the panel at the 0.5 mm level. After the file was introduced into the canal and reached the predetermined level, the file automatically stopped and rotated in the opposite direction. A reference point was marked and this measurement was registered as the auto reverse length (ARL). All measurements were made twice by two different investigators. Teeth were then extracted and immersed in a 20% formalin solution for 48 h. After fixation, a size 15 file was inserted into the canal to measure the actual root canal length from the same reference point obtained with the Tri Auto ZX to the apical foramen, as seen in the stereo microscope. When the file tip was visible at the anatomical end of the canal it was withdrawn 0.5 mm and this measurement was registered as the actual length (AL). All measurements were expressed in mm and the measuring accuracy was set to 0.5 mm. The significance of the mean differences between EL and ARL and between EL and AL measurements at the 5% confidence level was evaluated. RESULTS: EL measurements were coincident to ARL in all instances. EL and ARL were coincident to AL in 10 (40%) canals, in the remaining 15 canals (60%) the AL measurements were longer than EL and ARL (+0.5 mm) in 14 instances and shorter (-0.5 mm) in one case. Overall, the AL was longer than the EL or ARL, the mean difference being -0.23 mm +/- 0.32 (P < 0.05). CONCLUSIONS: It was concluded that the Tri Auto ZX was useful and reliable. The Tri Auto ZX measurements protected against overpreparation.

Adult↗

Influence of cervical preflaring on determination of apical file size in maxillary molars: SEM analysis.

The purpose of this study was to investigate the influence of cervical preflaring on determination of the initial apical file in mesiobuccal roots of maxillary molars. Fifty first molars with degree of curvature of the mesiobuccal root between 10 degrees and 15 degrees were utilized. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm from the root apex. Five groups (n=10) were formed at random, according to the type of cervical preflaring performed. In group 1, the size of the initial apical file was determined without cervical preflaring. In groups 2 to 5, the cervical and middle thirds of the canals were preflared with Gates-Glidden drills, K3 Orifice Opener instruments, ProTaper instruments and LA Axxess burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The binding instruments were fixed into the canals at the WL with methylcyanacrylate. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between the canal diameter and the diameter of first file to bind at the WL were calculated using UTHSCSA ImageTool software. Data were analyzed statistically by ANOVA and multiple comparisons were done by Tukey's HSD post-hoc test. Significant differences (p<0.001) were found among the groups. The major discrepancy was observed for the group without preflaring (mean 0.1543 mm +/- 0.0216). Cervical preflaring with LA Axxess burs produced the least discrepancies between the canal size and the diameter of the initial apical instrument (mean 0.026 mm +/- 0.0037), followed by ProTaper files (mean 0.0567 mm +/- 0.0354). Canals preflared with Gates-Glidden drills and K3 Orifice Opener instruments showed statistically similar discrepancy results to each other (p>0.05) (means 0.1167 mm +/- 0.0231 and 0.1313 mm +/- 0.0344, respectively). In conclusion, preflaring of the cervical and middle thirds improved the determination of the initial apical instrument. Canals preflared with LA Axxess burs showed a more accurate binding of the files to the anatomical diameter at the WL in the mesiobuccal roots of maxillary first molars.

Cyanoacrylates↗

Evaluation of the accuracy of three electronic apex locators using glass tubules.

AIM: To evaluate the accuracy of three different electronic apex locators (EALs) using glass tubules. METHODOLOGY: Forty-eight glass tubules with different diameters and an agar model were used to mimic root canals. A size 15 stainless steel K-file was used as the measuring electrode. The Root ZX, Propex and Neosono Ultima EZ were used to measure the tubule length with tubules dry, or filled with 0.9% NaCl, 3% H(2)O(2), 2.5% NaOCl or 17% EDTA. The distance between the real length (RL) and measured length (ML) of the tubules was recorded. The range of RL +/- 0.5 mm and RL +/- 1 mm was used to evaluate the accuracy of the EALs. Results were subject to correlation analysis and Friedman's test. RESULTS: In dry tubules, the accuracy of Root ZX was 75-91.7% for RL +/- 0.5 mm and 100% for RL +/- 1 mm, whilst the measurements of the other two EALs were all within the RL +/- 0.5 mm. No influence from the increase in tubule diameter on the accuracy of all three EALs was observed in dry tubules. In tubules filled with electrolyte, the accuracy of the Root ZX decreased as tubule diameter increased (R(d) > 0, P < 0.05). The RL-ML distance recorded by Propex was inversely related to the tubule diameter (R(d) < 0, P < 0.05). The accuracy of Propex was 75-100% for RL +/- 0.5 mm and 100% for RL +/- 0.5 mm when the tubule diameter was not more than 0.80 mm, but decreased in tubules with diameter over 0.80 mm and filled with 2.5% NaOCl or 17% EDTA. Nearly, all the measurements (except for six tubules) using Neosono Ultima EZ were within 1 mm shorter than RL despite the contents in tubules and the increase of tubule diameter. CONCLUSIONS: The accuracy of the Root ZX decreased as the tubule diameter increased when tubules were filled with electrolytes. The electrolytes in the tubules decreased the accuracy of Propex when the tubule diameter was large. The electrolytes in tubules and tubule diameter had no influence on the accuracy of Neosono Ultima EZ. The Propex and Neosono Ultima EZ were more accurate than the Root ZX under various conditions in this laboratory study.

Chelating Agents↗

Sealing properties of different resin-based root canal sealers.

In this study, a comparison of the sealing properties of three different resin-based sealers, AH26, Diaket, and EndoREZ with those of the root canal sealer zinc oxide-eugenol-based U/P Root Canal Sealer was performed. Eighty extracted single-rooted human mandibular first premolar teeth were used. The coronal part of each tooth was removed at the apical 17-mm of roots. The root canals were prepared to a size 7 with ProFile 0.06 taper Series 29 rotary instruments in a crown-down manner before lateral condensation of gutta-percha with the tested sealers (n = 20). A fluid filtration method was used for quantitative evaluation of apical leakage. Statistical analysis revealed that there were no significant differences between the resin-based sealers groups (AH26, Diaket, and EndoREZ) (p > 0.05). U/P Root Canal Sealer, zinc oxide-eugenol-based sealer, leaked significantly more than other tested groups (p < 0.05). Under the limitations of this study, resin-based root canal sealers were found more effective in sealing root canals than the zinc oxide-eugenol-based sealer.

Biocompatible Materials↗

Radiographic evaluation of apical root resorption with 2 different types of edgewise appliances. Results of a randomized clinical trial.

The purpose of this paper was to compare radiographically the prevalence and degree of apical root resorption after treatment with a fully programmed edgewise appliance (FPA) and a partly programmed edgewise appliance (PPA) in a randomized multipractice clinical trial. Two groups of patients with Class II malocclusions were treated orthodontically. The type of treatment was randomly assigned by a computer program. During fixed appliance therapy, one group was treated according to the precepts of the straight wire concept (FPA; n = 32) while the other was treated with conventional full edgewise mechanics (PPA; n = 29). Treatment times were recorded. Radiographs of the maxillary incisors were made before and after active treatment with fixed appliances using the bisecting angle technique. To correct for different projecting angles the pairs of radiographs were digitally reconstructed. The prevalence and degree of root resorption were assessed. The mean treatment time was 1.8 years and 1.6 years for treatment with FPA and PPA, respectively. The mean amount of loss of tooth length was 8.2% for the patients treated with FPA and 7.5% for the patients treated with PPA. No statistically significant differences could be assessed between both groups at the end of active treatment. The mean prevalence of apical root resorption was 75% for the patients treated with FPA and 55% for the patients treated with PPA. Statistical evaluation showed no significant differences. We concluded that the prevalence and degree of root resorption is independent of the appliances as used in this study.

Adolescent↗

Surgically assisted rapid palatal expansion. An acoustic rhinometric, morphometric and sonographic investigation.

This study aimed to evaluate the effect of surgically assisted rapid palatal expansion on the skeletal structures of the midface. Ten patients (mean age 28.5 years) were investigated by means of acoustic rhinometry, study model analysis and sonography before and after the procedure of surgically assisted rapid palatal expansion. The measurements revealed that surgically assisted rapid palatal expansion not only resulted in transverse expansion of the maxilla, providing dental arch space for lining up the teeth; the procedure also caused a substantial enlargement of the maxillary apical base and of the palatal vault, providing space for the tongue for correct swallowing and thus preventing relapse. There was a distinct subjective improvement in nasal breathing associated with enlargement of the nasal valve towards normal values and with an increase of nasal volume in all compartments. The measurements showed a marked influence of surgically assisted rapid palatal expansion on the skeletal structures of the midface. The significant widening can be demonstrated by non-invasive examination. Success of the osteotomy procedure can be readily monitored by sonographic examination of the expansion and the subsequent ossification, which allows individually adjusted retention periods and avoids frequent radiation exposure.

Acoustic Impedance Tests↗