PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “reflection”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Interpretation of principal components of the reflectance spectra obtained from multispectral images of exposed pig brain.

The spatial variation in reflectance such as the blood-vessel pattern can be observed in the image of cerebral cortex. This spatial variation is mainly caused by the difference in concentrations of oxy- and deoxyhemoglobin in the tissue. We analyze the reflectance spectra obtained from multispectral images of pig cortex by principal component analysis to extract information that relates to physiological parameters such as the concentrations of oxy- and deoxyhemoglobin and physical parameters such as mean optical path length. The light propagation in a model of exposed pig cortex is predicted by Monte Carlo simulation to estimate the interpretation of physiological and physical meanings of the principal components. The spatial variance of reflectance spectra of the pig cortex can be approximately described by the first principal component. The first principal component reflects the spectrum of hemoglobin in the cortical tissue multiplied by the mean optical path length. These results imply that the wavelength dependence of mean optical path length can be experimentally estimated from the first principal component of the reflectance spectra obtained from multispectral image of cortical tissue.

Animals↗

Combined reflectance and fluorescence spectroscopy for in vivo detection of cervical pre-cancer.

Optical technologies, such as reflectance and fluorescence spectroscopy, have shown the potential to provide improved point-of-care detection methods for cervical neoplasia that are sensitive, specific, and cost-effective. Our specific goals are to analyze the diagnostic potential of reflectance and fluorescence spectra, alone and in combination, to discriminate normal and precancerous cervical tissue in vivo and to identify which classification features contain significant diagnostic information. Reflectance spectra are measured at four source-detector separations and fluorescence emission spectra are measured at 16 excitation wavelengths, from 324 sites in 161 patients. These 20 spectral features are permuted in all possible combinations of one, two, and three; and classification algorithms are developed to evaluate the diagnostic performance of each combination. Algorithms based on fluorescence spectra alone yield better diagnostic performance than those based on reflectance spectra alone. The combination of fluorescence and reflectance do not significantly improve diagnostic performance compared to fluorescence alone, except in the case of discriminating high-grade precancers from columnar normal tissue. In general, fluorescence emission spectra at 330- to 360-nm and 460- to 470-nm excitation provide the best diagnostic performance for separating all pairs of tissue categories.

Algorithms↗

Transcranial measurement of diffuse light reflectance from cold-injured brains in rats.

Diagnosis of brain edema is important to manage severe head injuries and diseases, but there is no method of noninvasive bedside monitoring of brain edema. We speculate that brain edema changes the optical properties of brain tissue. To verify this speculation, we perform transcranial measurement of diffuse light reflectance from cold-injured brains in rats. To induce edema, a liquid nitrogen-cooled copper probe of 3 mm diameter was applied to the right parietal bone for 60 s under anesthesia. The rat skull was irradiated with 633-nm HeNe laser light and 532-nm Nd:YVO4 laser light, which were used to investigate changes in light scattering and blood flow, respectively. Reflectance intensity was measured as functions of time and position on the skull. We found that reflectance intensities were significantly decreased around the cold injury at both 633 and 532 nm, while reflectance was increased in the cold injury at 532 nm, indicating that cerebral blood volume was decreased in the cold injury. Under the condition of decreased cerebral blood volume, the decrease in reflectance intensity around the injury suggests that the scattering coefficient of brain tissue was reduced due to edema formation in this area.

Animals↗

Spatially resolved reflectance spectroscopy for diagnosis of cervical precancer: Monte Carlo modeling and comparison to clinical measurements.

We present Monte Carlo modeling studies to provide a quantitative understanding of contrast observed in spatially resolved reflectance spectra of normal and highly dysplastic cervical tissue. Simulations have been carried out to analyze the sensitivity of spectral measurements to a range of changes in epithelial and stromal optical properties that are reported to occur as dysplasia develops and to predict reflectance spectra of normal and highly dysplastic tissue at six different source-detector separations. Simulation results provide important insights into specific contributions of different optical parameters to the overall spectral response. Predictions from simulations agree well with in vivo measurements from cervical tissue and successfully describe spectral differences observed in reflectance measurements from normal and precancerous tissue sites. Penetration depth statistics of photons detected at the six source-detector separations are also presented to reveal the sampling depth profile of the fiber-optic probe geometry simulated. The modeling studies presented provide a framework to meaningfully interpret optical signals obtained from epithelial tissues and to optimize design of optical sensors for in vivo reflectance measurements for precancer detection. Results from this study can facilitate development of analytical photon propagation models that enable inverse estimation of diagnostically relevant optical parameters from in vivo reflectance measurements.

Biomarkers, Tumor↗

Reflection of drill-string extensional waves at the bit-rock contact.

Downward propagating extensional waves are partially reflected at the bit-rock contact. The evaluation of the reflection coefficient is important to obtain while drilling information about the acoustic properties of the formations. The scope of this work is to estimate the bit-rock reflection coefficient, assuming a flat drill bit in perfect contact with the formation. Using the low-frequency approximation, which holds when the wavelength is much larger than the lateral dimensions of the borehole, the drill-string is assumed to be a laterally free rod, and the formation an homogeneous and isotropic medium. This work shows that the reflection coefficient of the extensional waves depends, along with the elastic properties of the formation, on the ratio of the cross sections of the drill-string and borehole. The impedance of the drilled rock can be calculated from the measured reflection coefficient, which is related to the amplitude of waves produced in the string and in the formation by a working drill-bit.

Journal Article↗

The low-frequency reflection and scattering of the S0 Lamb mode from a circular through-thickness hole in a plate: Finite Element, analytical and experimental studies.

A study of the interaction of the S0 Lamb wave with a circular through-thickness hole in a plate is presented. The study is limited to the nondispersive frequency range of this wave, in which the distributions of stress and displacement are simple. This allows a Finite Element analysis to be undertaken using a two-dimensional membrane discretization. Predictions of the direct reflection of the S0 mode and the lateral scattering of the SH0 mode are made for a range of diameters of the hole. At the same time, an analytical solution based on modal superposition is developed, and this is also used to predict the reflection and scattering coefficients. Both sets of predictions are validated by experimental measurements. It is found that the trends of the reflection coefficients for different hole diameters, frequencies and distances from the hole satisfy a simple normalization. On a detailed scale, the functions exhibit undulations which are shown to result from the interference of the direct reflection with secondary reflections which arrive slightly later.

Journal Article↗

Multiple internal reflections in the cochlea and their effect on DPOAE fine structure.

In recent years, evidence has accumulated in support of a two-source model of distortion product otoacoustic emissions (DPOAEs). According to such models DPOAEs recorded in the ear canal are associated with two separate sources of cochlear origin. It is the interference between the contributions from the two sources that gives rise to the DPOAE fine structure (a pseudoperiodic change in DPOAE level or group delay with frequency). Multiple internal reflections between the base of the cochlea (oval window) and the DP tonotopic place can add additional significant components for certain stimulus conditions and thus modify the DPOAE fine structure. DPOAEs, at frequency increments between 4 and 8 Hz, were recorded at fixed f2/f1 ratios of 1.053, 1.065, 1.08, 1.11, 1.14, 1.18, 1.22, 1.26, 1.30, 1.32, 1.34, and 1.36 from four subjects. The resulting patterns of DPOAE amplitude and group delay (the negative of the slope of phase) revealed several previously unreported patterns in addition to the commonly reported log sine variation with frequency. These observed "exotic" patterns are predicted in computational simulations when multiple internal reflections are included. An inverse FFT algorithm was used to convert DPOAE data from the frequency to the "time" domain. Comparison of data in the time and frequency domains confirmed the occurrence of these "exotic" patterns in conjunction with the presence of multiple internal reflections. Multiple internal reflections were observed more commonly for high primary ratios (f2/f1 > or = 1.3). These results indicate that a full interpretation of the DPOAE level and phase (group delay) must include not only the two generation sources, but also multiple internal reflections.

Acoustic Stimulation↗

Active control of acoustic reflection, absorption, and transmission using thin panel speakers.

This paper explores the development of thin panels that can be controlled electronically so as to provide surfaces with desired reflection coefficients. Such panels can be used as either perfect reflectors or absorbers. They can also be designed to be transmission blockers that block the propagation of sound. The development of the control system is based on the use of wave separation algorithms that separate incident sound from reflected sound. In order to obtain a desired reflection coefficient, the reflected sound is controlled to appropriate levels. The incident sound is used as an acoustic reference for feedforward control and has the important property of being isolated from the action of the control system speaker. In order to use a panel as a transmission blocker, the acoustic pressure behind the panel is driven to zero. The use of the incident signal as a reference again plays a key role in successfully reducing broadband transmission of sound. The panels themselves are constructed using poster board and small rare-earth actuators. Detailed experimental results are presented showing the efficacy of the algorithms in achieving real-time control of reflection or transmission. The panels are able to effectively block transmission of broadband sound. Practical applications for these panels include enclosures for noisy machinery, noise-absorbing wallpaper, the development of sound walls, and the development of noise-blocking glass windows.

Journal Article↗

On the importance of early reflections for speech in rooms.

This paper presents the results of new studies based on speech intelligibility tests in simulated sound fields and analyses of impulse response measurements in rooms used for speech communication. The speech intelligibility test results confirm the importance of early reflections for achieving good conditions for speech in rooms. The addition of early reflections increased the effective signal-to-noise ratio and related speech intelligibility scores for both impaired and nonimpaired listeners. The new results also show that for common conditions where the direct sound is reduced, it is only possible to understand speech because of the presence of early reflections. Analyses of measured impulse responses in rooms intended for speech show that early reflections can increase the effective signal-to-noise ratio by up to 9 dB. A room acoustics computer model is used to demonstrate that the relative importance of early reflections can be influenced by the room acoustics design.

Adult↗

Ear canal reflectance in the presence of spontaneous otoacoustic emissions. I. Limit-cycle oscillator model.

Allen et al. [Abstract in Eighteenth Midwinter Research Meeting of the Association for Research in Otolaryngology, Des Moines, IA (1995)] have found that the ear canal reflectance passes through a minimum around the frequency of a spontaneous otoacoustic emission (SOAE). They considered this result to constitute evidence against active nonlinear cochlear function as the basis for SOAEs. In order to investigate theoretically the expected behavior of ear canal reflectance in the neighborhood of a SOAE associated with an active-nonlinear cochlea, we use a simplified model in which the ear drum end of the ear canal is effectively terminated by a nonlinear-active element. Under the influence of a sinusoidal driver at the entrance of the ear canal, this element will, to a good approximation, either (1) oscillate at both the frequency of the driver (at which the reflectance is determined) and the SOAE (at a suppressed level, corresponding to nonentrainment), or (2) be entrained and only oscillate at the driving frequency. The magnitude of the nonlinear ear canal reflectance is found to exceed unity only at sufficiently low stimulus levels, and occurs under conditions of entrainment and nonentrainment of the spontaneous emission. Otherwise, the reflectance is less than unity and, as a function of frequency, has a minimum around the SOAE frequency.

Ear Canal↗

Bright Spots, Structure, and Magmatism in Southern Tibet from INDEPTH Seismic Reflection Profiling

INDEPTH seismic reflection profiling shows that the decollement beneath which Indian lithosphere underthrusts the Himalaya extends at least 225 kilometers north of the Himalayan deformation front to a depth of approximately 50 kilometers. Prominent reflections appear at depths of 15 to 18 kilometers near where the decollement reflector apparently terminates. These reflections extend north of the Zangbo suture to the Damxung graben of the Tibet Plateau. Some of these reflections have locally anomalous amplitudes (bright spots) and coincident negative polarities implying that they are produced by fluids in the crust. The presence of geothermal activity and high heat flow in the regions of these reflections and the tectonic setting suggest that the bright spots mark granitic magmas derived by partial melting of the tectonically thickened crust.

Journal Article↗

The left paratracheal reflection.

The left paratracheal reflection, which is found medial to the left subclavian artery reflection, was sought in 302 normal posteroanterior (PA) chest radiographs, 93 conventional chest tomograms, and 113 thoracic computed tomographic (CT) scans. The left paratracheal reflection was visible on 31% of normal PA chest radiographs. Conventional tomography and CT showed that this finding is produced by contact of the lung with the mediastinum anterior to the left subclavian artery. The CT scans studied showed that the left paratracheal reflection actually represents contact of the lung with left paratracheal mediastinal fat 94% of the time, with the proximal 1-2 cm of the lateral wall of the left common carotid artery 5% of the time, and with the left tracheal wall 1% of the time. A variety of entities may alter the left paratracheal reflection.

Adult↗

Measurement of redox states of mitochondrial cytochrome aa3 in regions of liver lobule by reflectance microspectroscopy.

To evaluate the sublobular distribution of oxygen tension, the redox states of mitochondrial cytochrome aa3 were assessed in local regions of the liver lobule by reflectance microspectroscopy. The reflected light from two focused microspots (20 microns in diam) on the surface of the perfused liver, placed on the stage of microscope, was conducted to the spectrophotometer with two separate light guides, giving the reflectance spectra. The redox state of cytochrome aa3 was calculated from the difference in reflectance between 603 and 630 nm. The degree of cytochrome reduction increased with the stepwise decline of the influent or effluent oxygen concentrations. The local oxygen concentration in periportal region for the half-maximal reduction of cytochrome aa3 was higher than that in pericentral region. In addition, the degree of cytochrome aa3 reduction increased with the distance from the periportal region, reflecting a physiological gradient of oxygen tension along the sinusoidal flow, although with an intersinusoidal heterogeneity within liver lobule.

Animals↗

Propagation velocity and reflection of pressure waves in the canine coronary artery.

In this study the pressure wave velocity in the anterior descending branch of the left coronary artery (LADC) of the dog was measured by determining the delay time between pressure pulses along this artery. This method can only be applied if reflections of the pressure wave distal to the sites of pressure measurement are insignificant. From araldite casts of the coronary arteries the following relation between the diameter proximal to (dprox) and distal to (ddist 1, ddist 2) a bifurcation was found: dprox2.55 = ddist12.55 + ddist 22.55, indicating that reflections at a bifurcation areminimal. In dogs reflections were studied by inducing during diastole a pressure pulse in the aorta and measuring pressure and volume flow proximal to and pressure distal to a segment of the LADC at various levels of the coronary peripheral resistance. Reflection of high-frequency components (greater than 7 Hz) was found to be insignificant, allowing application of the above-mentioned method for measuring the wave-front velocity, which is insensitive to low-frequency reflection. At a pressure in the LADC of 13.3 kPa this velocity was 8.6 +/- 1.4 m.s-1 (mean +/- SD). The calculated dynamic cross-sectional stiffness (deltaP/(deltaA/A)) of the LADC was 97 +/- 11 kPa (mean +/- SE) at an arterial pressure of 13.3 kPa.

Animals↗

Reflectance measurements of hematocrit and oxyhemoglobin saturation.

Fiberoptic oximeters measure oxyhemoglobin saturation from the optical reflectance of whole blood, but the calibration of such oximeters is hematocrit dependent. Therefore, using photon-diffusion theory and an empirical approach, we have developed a new reflectance method that determines hematocrit and correspondingly corrects the oxyhemoglobin-saturation measurement. Our method employs four fiber-optic light guides, a photodetector, and three inexpensive light-emitting diodes (one with emissions at 660 nm and two at 813 nm). Hematocrit is determined from the ratio of reflectances from the differently spaced emitting fibers at 813 nm and is used to correct the 813-660 nm measurement of oxyhemoglobin saturation. In red cell suspensions, the mean difference between reflectance measurements of hematocrit and conventional determinations was only 2.09% (r = 0.99), and when compared with conventional gasometric measurements of oxyhemoglobin saturation, the reflectance method yielded the same calibration curve for different hematocrits and gave a mean difference of only 2.67%. Although the technique is demonstrated with a cuvette appropriate for an extracorporeal circulation in animal experiments, it could possibly be further developed for fiber-optic catheter oximeters.

Animals↗

Nonhuman primate model for regional wave travel and reflections along aortas.

Arterial pulse transmission and wave reflections were studied in five mature anesthetized baboons (Papio anubis) using multisensor micromanometry. Simultaneous pressures were recorded from the left ventricle and every 10 cm along the aorta and its terminal branches, and flow velocity was measured in the aortic root. Aortic input impedance and regional foot-to-foot and apparent phase velocities were calculated. Aortography provided dimensional data for local reflection coefficients. Regional foot-to-foot wave speeds were somewhat lower than corresponding segments in humans. Proximal aortic pressure waveforms and characteristic impedance (110 +/- 29 dyn X s X cm-5) were not characteristic of middle-aged humans. Reflection coefficients at the terminal aortic bifurcation (0.06) at the level of the renal artery branches (0.09) were less than those found in humans. We conclude that the junction of the renal artery branches and the aorta in the baboon is closely matched and represents much less of a discrete reflection site than in humans. Although the baboon may be used to study pulse transmission characteristics in the baboon, this species is not a good model for the proximal systemic reflective characteristics of normal middle-aged humans.

Animals↗

Role of arterial design on pulse wave reflection in a fractal pulmonary network.

A novel interpretation of pulmonary arterial input impedance was evaluated for the lung as a fractal vascular network. We hypothesized that local sources of reflection introduce trends of global reflection into the input impedance spectra. These trends are related to the network topology, geometry, and design according to Rb = Rdx, where Rb is the branching ratio, Rd is the diameter ratio, and x is the fractal dimension quantifying design. Simulations using values of Rd and x, which were derived morphometrically, confirmed two patterns of global reflection: a continuous trend attributed to a single effective site of reflection caused by frequency-dependent sources of impedance contrast and a discrete trend arising from a longitudinal distribution of frequency-independent sources of reflection. The continuous trend depended only on the network parameter Rd, whereas the discrete trend depended on Rd and x. Our results indicate that the impedance-matching properties of a deterministic pulmonary fractal network encode arterial geometry and topology via function and that typical values of Rd and x for the pulmonary circulation facilitate shear stress amplification in its peripheral vessels. Thus, inasmuch as shear forces may be involved in the endothelial mechanisms for pathological, or physiological, vascular remodeling, broadband input impedance analysis may reveal interactions between network organization and vascular function.

Animals↗

Neonatal and adult rabbit renal brush border membrane vesicle solute reflection coefficients.

The interaction between solute and water in epithelial transport is represented by the solute reflection coefficient. Because the osmotic water transport process changes in the rabbit proximal tubule during maturation, there is a potential for the solute reflection coefficients to also undergo maturational changes. In the present study, we directly examined solute reflection coefficients in neonatal and adult brush border membrane vesicles (BBMV) using the stop-flow light-scattering technique. Reflection coefficients for NaCl, KCl, NaHCO3 and urea were found to be identical in the neonatal and adult BBMV and were not different from 1. Thus, although the water transport pathway undergoes changes in the proximal tubule during maturation, there is no evidence for changes in solute and water interaction. Because the reflection coefficients are not different from 1, there is no evidence for solvent drag in the proximal tubule apical membrane in either the neonatal or adult tubule.

Aging↗