PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Finite Element Analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Biomechanical study of the resurfacing hip arthroplasty: finite element analysis of the femoral component.

Finite element analysis was performed using 3-dimensional models to examine the biomechanical characteristics of the femoral component in resurfacing hip arthroplasty. Stress concentration was observed in the cortical bone adjacent to the rim of the prosthesis. Stress shielding was observed in the anterosuperior regions on the cancellous bone cross-sections near the cup rim. These biomechanical characteristics may lead to complications such as femoral neck fractures in patients with osteopenic bone and long-term loosening.

Arthroplasty, Replacement, Hip↗

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗

Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.

PURPOSE: A 3-dimensional finite element analysis was performed to evaluate the influence of implant type and length, as well as that of bone quality, on the stress/strain in bone and implant. MATERIALS AND METHODS: Two types (screw and cylinder) and 4 lengths (9.2, 10.8, 12.4, and 14.0 mm) of titanium implants were buried in 4 types of bone modeled by varying the elastic modulus for cancellous bone. Axial and buccolingual forces were applied to the occlusal node at the center of the abutment. RESULTS: Regardless of load direction, maximum equivalent stress/strain in bone increased with a decrease in cancellous bone density. Under axial load, especially in the low-density bone models, maximum equivalent strain in cancellous bone was lower with the screw-type implant than with the cylinder-type implant. It was also lower with the longer implants than with the shorter implants. Under buccolingual load, equivalent stress/strain was influenced mainly by bone density. DISCUSSION: This study confirms the importance of bone quality and its presurgical diagnosis for implant long-term prognosis. Implant length and type can also influence bone strain, especially in low-density bone. CONCLUSIONS: The results of this study suggest that cancellous bone of higher rather than lower density might ensure a better biomechanical environment for implants. Moreover, longer screw-type implants could be a better choice in a jaw with cancellous bone of low density.

Biomechanical Phenomena↗

Biomechanical comparison of instrumented posterior lumbar interbody fusion with one or two cages by finite element analysis.

STUDY DESIGN: Using finite element models to study the biomechanics of lumbar instrumented posterior lumbar interbody fusion (PLIF) with one or two cages. OBJECTIVE: Analyzing the biomechanics of instrumented PLIF with one or two cages as to evaluate whether a single cage is adequate for instrumented PLIF. SUMMARY OF BACKGROUND DATA: Implantation of a single cage in instrumented PLIF of lumbar spine is still controversial. METHODS: Three validated finite element models of L3-L5 lumbar segment were established [intact model (INT), one cage model (LS-1), and two cages model (LS-2)]. The available finite element program ANSYS 6.0 (Swanson Analysis System Inc., Houston, TX) was applied. To analyze the biomechanics of these models, 10 Nm flexion, extension, rotation, and lateral bending moment with 150 N of preload were respectively imposed on the superior surfaces of the L3. RESULTS: Compared with the INT model, the decrease of ROM in the LS-1 and LS-2 models were exaggerated from 0.67 degrees to 3.73 degrees and ranged from 37.2% to 86.1% in all motions. The mean subsidence was found to be slightly higher in the LS-1 model. Most of the cage dislodgement in both models was less than 0.03 mm. The mean dislodgement was slightly higher in the LS-1 model. The stress of cage was found to be high in the LS-2 model. The mean stress of screw was raised to 4.5% to 9.7% in the LS-1, which was higher than that in the LS-2 model. In general, stress of adjacent disc was more pronounced in the LS-2 model. The most stress distributed at the anterior portion of the adjacent disc, which could be used to interpret the clinical findings of the early adjacent disc degeneration. CONCLUSIONS: A single cage inserted in an instrumented PLIF gains approximate biomechanical stability, slight greater subsidence, and a slight increase in screw stress but less early degeneration in adjacent disc. Adjusting these factors, instrumented PLIF with one cage could be encouraged in clinical practice.

Biomechanical Phenomena↗

The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.

STUDY DESIGN: A finite-element study of posterior alone or anterior/posterior combined instrumentation following total spondylectomy and replacement with a titanium mesh cage used as an anterior strut. OBJECTIVES: To compare the effect of posterior instrumentation versus anterior/posterior instrumentation on transmission of the stress to grafted bone inside a titanium mesh cage following total spondylectomy. SUMMARY OF BACKGROUND DATA: The most recent reconstruction techniques following total spondylectomy for malignant spinal tumor include a titanium mesh cage filled with autologous bone as an anterior strut. The need for additional anterior instrumentation with posterior pedicle screws and rods is controversial. Transmission of the mechanical stress to grafted bone inside a titanium mesh cage is important for fusion and remodeling. To our knowledge, there are no published reports comparing the load-sharing properties of the different reconstruction methods following total spondylectomy. METHODS: A 3-dimensional finite-element model of the reconstructed spine (T10-L4) following total spondylectomy at T12 was constructed. A Harms titanium mesh cage (DePuy Spine, Raynham, MA) was positioned as an anterior replacement, and 3 types of the reconstruction methods were compared: (1) multilevel posterior instrumentation (MPI) (i.e., posterior pedicle screws and rods at T10-L2 without anterior instrumentation); (2) MPI with anterior instrumentation (MPAI) (i.e., MPAI [Kaneda SR; DePuy Spine] at T11-L1); and (3) short posterior and anterior instrumentation (SPAI) (i.e., posterior pedicle screws and rods with anterior instrumentation at T11-L1). The mechanical energy stress distribution exerted inside the titanium mesh cage was evaluated and compared by finite-element analysis for the 3 different reconstruction methods. Simulated forces were applied to give axial compression, flexion, extension, and lateral bending. RESULTS: In flexion mode, the energy stress distribution in MPI was higher than 3.0 x 10 MPa in 73.0% of the total volume inside the titanium mesh cage, while 38.0% in MPAI, and 43.3% in SPAI. In axial compression and extension modes, there were no remarkable differences for each reconstruction method. In left-bending mode, there was little stress energy in the cancellous bone inside the titanium mesh cage in MPAI and SPAI. CONCLUSIONS: This experiment shows that from the viewpoint of stress shielding, the reconstruction method, using additional anterior instrumentation with posterior pedicle screws (MPAI and SPAI), stress shields the cancellous bone inside the titanium mesh cage to a higher degree than does the system using posterior pedicle screw fixation alone (MPI). Thus, a reconstruction method with no anterior fixation should be better at allowing stress for remodeling of the bone graft inside the titanium mesh cage.

Aged, 80 and over↗

The hind wing of the desert locust (Schistocerca gregaria Forskål). III. A finite element analysis of a deployable structure.

Finite element analysis is used to model the automatic cambering of the locust hind wing during promotion: the umbrella effect. It was found that the model required a high degree of sophistication before replicating the deformations found in vivo. The model has been validated using experimental data and the deformations recorded both in vivo and ex vivo. It predicts that even slight modifications to the geometrical description used can lead to significant changes in the deformations observed in the anal fan. The model agrees with experimental data and produces deformations very close to those seen in free-flying locusts. The validated model may be used to investigate the varying geometries found in orthopteran anal fans and the stresses found throughout the wing when loaded.

Animals↗

Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis.

The three-dimensional finite element analysis method was used to assess stress in bone around titanium implants using three treatment designs for a partially edentulous mandible, under axial (AX), buccolingual (BL), or mesiodistal (MD) loads. For each of these loads, highest stress was calculated in the model with a cantilever prosthesis supported by two implants (M2). Less stress was found in the model with a conventional fixed partial denture on two implants (M3), and lowest stress was calculated in the model with three connected crowns supported by three implants (M1). When BL load was applied to M3, cortical bone stress was high, comparable to that calculated for M2 under the same load. When AX or MD load was applied to M3, the cortical bone stress was low, similar to that found in M1 under each of these loads.

Bicuspid↗

Finite element analysis of nanostructures with roughness and scratches.

Finite element analysis facilitates optimal design of MEMS/NEMS devices for reliability. A finite element method (FEM) was developed to analyze the effect of types of surface roughness and scratches on stresses of nanostructures. Beams with surface roughness in the form of semicircular and grooved asperities in varying numbers in the longitudinal direction were considered. In the transverse direction semicircular asperities and scratches in varying numbers and with different pitch were modeled. Furthermore semicircular asperities were truncated both in longitudinal and transverse direction and analyzed. It was observed that the asperities and scratches increase the bending tensile stresses which could lead to failure of MEMS/NEMS devices. The beam material was assumed to be purely elastic, elastic-plastic and elastic-perfectly plastic to observe the variations in the bending stresses and displacements for both smooth nanobeam and nanobeam with defined roughness. The results of the analysis can be useful to designers to develop the most suitable geometry for nanostructures.

Journal Article↗

Constitutive model of brain tissue suitable for finite element analysis of surgical procedures.

Realistic finite element modelling and simulation of neurosurgical procedures present a formidable challenge. Appropriate, finite deformation, constitutive model of brain tissue is a prerequisite for such development. In this paper, a large deformation, linear, viscoelastic model, suitable for direct use with commercially available finite element software packages such as ABAQUS is constructed. The proposed constitutive equation is of polynomial form with time-dependent coefficients. The model requires four material constants to be identified. The material constants were evaluated based on unconfined compression experiment results. The analytical as well as numerical solutions to the unconfined compression problem are presented. The agreement between the proposed theoretical model and the experiment is good for compression levels reaching 30% and for loading velocities varying over five orders of magnitude. The numerical solution using the finite element method matched the analytical solution very closely.

Algorithms↗

Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis.

OBJECTIVES: Three-dimensional finite element (FE) models of splinted prosthetic crowns were studied and stress analyses were evaluated with different types of implant support, including standard, wide or two implant(s) for partial, posterior edentulous restorations. MATERIAL AND METHODS: The FE models were constructed based on a cadaver mandible containing the 2nd premolar and the 1st molar. The crowns of these two teeth were modeled as connected and disconnected to mimic the splinted and non-splinted designs, respectively. One standard implant was placed at the premolar region, while three types of implant support, one at a time (the standard implant, wide implant and two implants), were used to support the molar crown. A 100 N oblique load was applied to the buccal cusp on each crown. The FE simulation was validated experimentally via strain gauge measurement. RESULTS: The experimental data were well correlated with the FE predictions (r(2)=0.97). When compared with the standard implant used in the molar area, the wide implant and two implants reduced the peak stress in crestal bone by 29-37% for both splinted and non-splinted cases. Inserting the standard implant into both the premolar and molar area, the bone stresses were identical for splinted and non-splinted designs. However, splinting the adjacent crowns has shown to decrease the bone stresses at the premolar region by 25%, while the wide implant or two implants were placed at the molar region. CONCLUSION: The biomechanical advantages of using the wide implant or two implants are almost identical. The benefit of load sharing by the splinted crowns is notable only when the implants on the premolar and molar regions have different supporting ability.

Alveolar Process↗

Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.

PURPOSE: This finite element analysis was conducted to determine the magnitude of stress in the supporting bone when implants were arranged in either a straight-line or an offset configuration. In addition, the effects of axial and nonaxial loading and changes in prosthesis height were assessed. MATERIALS AND METHODS: An 8-node hexahedral solid-element 3-dimensional finite element analysis model of the mandible was created using PATRAN software. Three titanium endosseous implants were placed in the model 7 mm apart. The center implant was placed on the line from the centers of the terminal implants (no offset), 1.5 mm lateral to this line (1.5-mm offset), or 3.0 mm lateral to this line (3.0-mm offset). Forces of 200 N were applied to a point corresponding to the center of the middle implant when the implants were in a straight-line configuration. Forces were applied in a straight vertical direction or in 15-degree increments to the vertical to a maximum of 60 degrees. Simulated type IV gold prostheses were made to simulate heights of 6 and 12 mm. RESULTS: The least stress in the supporting bone was found with vertical loading of the no-offset implants with the 6-mm prosthesis (3.12 MPa) followed by the same alignment with the 12-mm prosthesis (3.86 MPa). Changing the angle of force application by 15 degrees resulted in increased stress to the underlying bone, and the creation of an offset did not fully compensate for this increased stress. DISCUSSION: In contrast to previous studies, this study examined 3 elements not previously studied together in a single finite element analysis, using the maximum offset defined by normal anatomic contours of mandibular premolar and molar teeth, thereby describing the relative importance of clinically relevant methods for stress reduction. CONCLUSIONS: Vertical loading of an implant-supported prosthesis produced the lowest stress to the supporting bone. Changes in the angle of force application resulted in greater stress to supporting bone. Reduction in prosthesis height or use of an offset implant location for the middle implant reduced stress, but the reduction did not compensate for the increase found with off-axis loading.

Alveolar Process↗

Microvascular stress analysis. Part I: simulation of microvascular anastomoses using finite element analysis.

PURPOSE OF THE STUDY: To develop a finite element model (FEM) to study the effect of the stress and strain, in microvascular anastomoses that result from the geometrical mismatch of anastomosed vessels. MATERIAL AND METHODS: FEMs of end-to-end and end-to-side anastomoses were constructed. Simulations were made using finite element software (NISA). We investigated the angle of inset in the end-to-side anastomosis and the discrepancy in the size of the opening in the vessel between the host and recipient vessels. The FEMs were used to predict principal and shear stress and strain at the position of each node. RESULTS: Two types of vascular deformation were predicted during different simulations: longitudinal distortion, and rotational distortion. Stress values ranged from 151.1 to 282.4MPa for the maximum principal stress, from -122.9 to -432.2MPa for the minimum principal stress, and from 122.1 to 333.1MPa for the maximum shear stress. The highest values were recorded when there was a 50% mismatch in the diameter of the vessels at the site of the end-to-end anastomosis. CONCLUSION: The effect of the vessel's size discrepancy on the blood flow and deformation was remarkable in the end-to-end anastomosis. End-to-side anastomosis was superior to end-to-end anastomosis. FEM is a powerful tool to study vascular deformation, as it predicts deformation and biomechanical processes at sites where physical measurements are likely to remain impossible in living humans.

Anastomosis, Surgical↗

Finite element analysis applied to cornea reshaping.

A 2-D finite element model of the cornea is developed to simulate corneal reshaping and the resulting deformation induced by refractive surgery. In the numerical simulations, linear and nonlinear elastic models are applied when stiffness inhomogeneities varying with depth are considered. Multiple simulations are created that employ different geometric configurations for the removal of the corneal tissue. Side-by-side comparisons of the different constitutive laws are also performed. To facilitate the comparison, the material property constants are identified from the same experimental data, which are obtained from mechanical tests on corneal strips and membrane inflation experiments. We then validate the resulting models by comparing computed refractive power changes with clinical results. Tissue deformations created by simulated corneal tissue removal using finite elements are consistent with clinically observed postsurgical results. The model developed provides a much more predictable refractive outcome when the stiffness inhomogeneities of the cornea and nonlinearities of the deformations are included in the simulations. Finite element analysis is a useful tool for modeling surgical effects on the cornea and developing a better understanding of the biomechanics of the cornea. The creation of patient-specific simulations would allow surgical outcomes to be predicted based on individualized finite element models.

Computer Simulation↗

Finite element analysis as a tool for parametric prosthetic foot design and evaluation. Technique development in the solid ankle cushioned heel (SACH) foot.

In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed based upon loading conditions obtained from the gait analysis of an amputee and validated experimentally using mechanical testing. The model was then used to address effects of viscoelastic heel performance numerically. This is just one example of the type of parametric analysis and design enabled by this approach. More importantly, by incorporating the unique gait characteristics of the amputee, these parametric analyses may lead to prosthetic feet more appropriately representing a particular user's needs, comfort and activity level.

Amputation, Surgical↗

The tympanic membrane in cross section: a finite element analysis.

This paper applies the technique of finite element analysis to the tympanic membrane. A two-dimensional cross-sectional model of the tympanic membrane and malleus is described. A variety of experiments have been performed on this model, and the displacements under a uniform load are analysed. The shape of the displaced membrane and the movement of the umbo were found to be sensitive to a number of factors. These include the elastic modulus of the membrane, the presence and position of the axis or rotation of the malleus, and the size of the pars flaccida. Some implications of these results are discussed.

Humans↗

[A finite element analysis system for two-demension morphological analysis of the soft tissue in orthognathic surgery].

OBJECTIVE: To evaluate a finite element method (FEM) for analysis of the cranial-facial morphology. METHODS: The two-dimensional finite element analysis system was established and used to analysis the lateral side morphology of the soft tissue by the change of each finite unit of the soft tissue in a X-ray cranial-facial lateral cepholometrics film. RESULTS: The finite element analysis system was showing very well in the figures and data made by the system. CONCLUSION: Finite element analysis system may be a good supplement of the traditional X-ray cephalometrics to the soft tissue of orthognatics.

Cephalometry↗

Two dental implants designed for immediate loading: a finite element analysis.

PURPOSE: The aim of this study was to evaluate by finite element analysis the influence of the design of 3 different dental implants on micromovements, cervical shearing stress intensity, and stress distribution after occlusal loading. MATERIALS AND METHODS: The first investigated implant was a classical cylinder, the second was reinforced by 2 bicortical locking pins, and the third was an expanding dental implant. The parameters analyzed were the implant's geometry, the quality of the cancellous bone, and the orientation of occlusal loading. RESULTS: It was found that initial stability of the locking pin implant was greater than the initial stability of the other investigated implant designs, regardless of the quality of cancellous bone and orientation of occlusal loading; in low-rigidity cancellous bone, under a horizontal load (500 N), decreasing displacement compared to those of the other investigated implants was 16 microm. The apical expansion and locking pin implants exhibited favorable behavior regarding the distribution and intensity of cervical shearing stresses; in low-rigidity cancellous bone, under horizontal load, decreasing cervical stresses compared with those of the cylindric implant were 10 MPa for the apical expansion implant and 150 MPa for the locking pin implant. DISCUSSION: For the cylindric implant, stresses were concentrated in the neck region; for the apical expansion implant, stresses were evenly distributed from the neck to the apex of the implant. For the locking pin implant, stresses around the neck were moderate and appeared concentrated around the pins. CONCLUSIONS: Initial stability of the pin implant was greater than that of the expanding implant, but the expanding implant showed the most favorable stress distribution.

Bite Force↗