PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “HEXYLAMINES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Tresyl activation of a hydroxyalkyl ligand for coupling to a hydrazide gel: stable immobilization of T-2 toxin for affinity purification of T-2 antibody.

A stable T-2 hydrazide gel is prepared by activating T-2 toxin with tresyl chloride followed by coupling to agarose-adipic acid hydrazide. Utilized as an affinity chromatography column, this T-2 hydrazide gel purifies a monoclonal antibody for T-2 in high yield directly from ascites fluid. Specific antibody trapped on the column is eluted either with excess T-2 or at pH 11.6. Much less successful are two other T-2 affinity columns that were prepared and evaluated: T-2 bovine serum albumin Affi-Gel 15 and T-2 hexylamine Sepharose.

Antibodies↗

Determination of (S)-(-)-cathinone and its metabolites (R,S)-(-)-norephedrine and (R,R)-(-)-norpseudoephedrine in urine by high-performance liquid chromatography with photodiode-array detection.

A high-performance liquid chromatographic (HPLC) procedure with photodiode-array detection (DAD) is described for the determination of (S)-(-)-cathinone (S-CA) and its metabolites (R,S)-(-)-norephedrine (R-NE) and (R,R)-(-)-norpseudoephedrine (R-NPE) in urine. Extraction and clean-up of 1-ml urine samples were performed on a cyano-bonded solid-phase column using (+/-)-amphetamine as internal standard. The concentrated extracts were separated on a 3-microns ODS-1 column with acetonitrile-water-phosphoric acid-hexylamine as the mobile phase. Peak detection was done at 192 nm. The detection limits for S-CA and R-NE/R-NPE in urine were 50 and 25 ng/ml, respectively. The differentiation of the enantiomers of cathinone and norephedrine was achieved by derivatization with (S)-(-)-1-phenylethyl isocyanate to the corresponding diastereomers followed by HPLC-DAD on a 5-microns normal-phase column. The R and S enantiomers of norpseudoephedrine were determined by gas chromatography-mass spectrometry after on-column derivatization with (S)-(-)-N-trifluoroacetylprolyl chloride. Following a single oral dose of 0.5 mg/kg of S-CA, the concentrations found in urine ranged from 0.2 to 3.8 micrograms/ml of S-CA, from 7.2 to 46.0 micrograms/ml of R-NE and from 0.5 to 2.5 micrograms/ml of R-NPE.

Alkaloids↗

Determination of psychotropic phenylalkylamine derivatives in biological matrices by high-performance liquid chromatography with photodiode-array detection.

Several procedures using high-performance liquid chromatography with photodiode-array detection have been developed to create phytochemical and toxicological profiles of phenylalkylamine derivatives in biological samples (e.g. plant materials and urine). Mescaline-containing cactus samples were extracted with basic methanol, using methoxamine as internal standard; the extraction and clean-up of urine samples were performed on cation-exchange solid-phase extraction columns. The extracts were separated on a 3-micron ODS column with acetonitrile-water-phosphoric acid-hexylamine as the mobile phase. Peak detection was performed at 198 or 205 nm; peak identity and homogeneity were ascertained by on-line scanning of the UV spectra from 190 to 300 nm. The detection limit of phenylalkylamine derivatives in urine and cactus material was 0.026-0.056 micrograms/ml and 0.04 micrograms/mg, respectively. Following a single oral dose of 1.7 mg/kg methylenedioxymethylamphetamine (MDMA) the concentrations found in urine ranged from 1.48 to 5.05 micrograms/ml MDMA and 0.07-0.90 micrograms/ml methylenedioxyamphetamine (a metabolite of MDMA). The mescaline content of the cactus Trichocereus pachanoi varied between 1.09 and 23.75 micrograms/mg.

Amphetamines↗

Homogeneous substrate-labeled fluorescent immunoassay for IgG in human serum.

A homogeneous substrate-labeled fluorescent immunoassay for IgG has been developed. Purified IgG was covalently labeled with 6-(7-beta-galactosylcoumarin-3-carboxamido)-hexylamine to form a stable conjugate, GU-IgG. The galactosyl residue was hydrolyzed from GU-IgG by beta-galactosidase and the progress of the hydrolysis was monitored by the increase in fluorescence emission at 450 nm with excitation at 400 nm. Antibody to IgG diminished the activity of GU-IgG as a substrate for beta-galactosidase. Competitive binding immunoassays were conducted by allowing added IgG and GU-IgG to compete for a limited number of antibody binding sites. Hence, the fluorescence produced by enzymic hydrolysis increased with the level of added IgG. This method provides a simple and reliable immunoassay for IgG and is applicable to other proteins.

Antibodies↗

6-Oxygenation of 3-oxo-4-ene-steroids in high yields after 3-imine-formation.

3-Imine formation between primary amines and 3-oxo-4-ene-steroids, followed by hydrolysis of the imines (either spontaneously during work up or induced by acetic acid) has been shown to cause 6-oxygenation of the steroids tested (17 beta-hydroxy-4-androsten-3-one, 4-androstene-3,17-dione, 4-pregnene-3,20-dione and 4-cholesten-3-one). The main products are the 6 beta-hydroxy- and the 6-oxo-derivatives of the respective steroid. These derivatives were identified by chromatographic mobilities and by gas chromatography-mass spectrometry. The formation of 6 beta-hydroperoxy-derivatives is suggested and these derivatives were tentatively identified. The highest yields of 6-oxygenated products (30-50%) were found when cadaverine and spermine were reacted with the steroids. The addition of reduced glutathione during hydrolysis of the steroid 3-imines of cadaverine, hexylamine and ethanolamine as well as addition of ascorbic acid during the hydrolysis of the steroid 3-imines of cadaverine substantially reduced the 6-oxygenation. Steroid 3-imine formation and hydrolysis which yields 6-oxygenated derivatives has also been shown to occur during work up (evaporation) of organic solvent extracts of rat liver microsomes (105,000 g sediments) to which 17 beta-hydroxy-4-androsten-3-one, 4-androstene-3,17-dione, 4-pregnene-3,20-dione or 4-cholesten-3-one respectively had been added. It is concluded that there is a risk that these organic reactions are mistaken for enzymatic conversions during in vitro investigations of 3-oxo-4-ene-steroids.

Animals↗

Micromolar Ca2+ requiring protease from human platelets: purification, partial characterization and effect on the cytoskeletal proteins.

A calcium-activated neutral protease (CANP) has been purified 2,800 fold, to near homogeneity, from human platelets. The purification procedure involved ammonium sulfate fractionation of the platelet cytosol followed by chromatography on Sephacryl S-200, DEAE-Sephacel, Agarose-Hexylamine, Agarose-Octylamine and alpha-casein-Sepharose 4B affinity gel. The protease consisted of two polypeptides of Mr = 74,000 and 28,000 as judged on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. It hydrolyzed [methyl-14C] alpha-casein at a significant rate of 37 degrees C which was, therefore, used as an exogenous substrate. Microtubules and intermediate filament proteins were also susceptible to hydrolysis by the purified protease. It attained maximum activity at 0.06 uM CaCl2 and displayed two pH maxima: one at 5.5 and the other at 6.5. The protease was fully active in the presence of MnCl2 and was about 75% active with BaCl2 and SrCl2. Among the actinomycete protease inhibitors, leupeptin, antipain and pepstatin, the order of inhibition was: leupeptin greater than antipain greater than pepstatin. The protease was also inhibited by sulfhydryl modifying agents.

Blood Platelets↗

The use of fluorescent probes as markers for sheep lymphocyte subpopulations.

Sheep blood lymphocytes were labelled with fluorescent probes and examined under the fluorescence microscope and by the fluorescence-activated cell sorter. A novel probe using fluorescamine, coupled to hexylamine, detected 22.9% of cells, apparently of the B-cell series, counted by fluorescence microscopy. Substitution of fluorescein isothiocyanate (FITC) for the fluorescamine did not label the same subpopulation of cells although the lymphocytes could then be examined in the cell sorter. A larger number of cells (38.8%) formed the brighter cluster but did not behave as B cell when separated on nylon-wool columns. Improvement in discrimination of the cell populations was obtained with FITC-hexadecylamine (C16). This probe detected 38% of cells in the smallest cluster, 44% of cells in the intermediate cluster and 19% of cells in the brightest cluster. The proportion of cells in each cluster appeared to parallel closely the "null", erythrocyte (E) rosette-forming T cells and the B cells detected by conventional markers for blood lymphocytes. Other fluorescent probes, formed from FITC and other amines and amino acids, labelled lymphocyte membranes. Probes with a terminal charge labelled the small cluster particularly well, whereas those that were terminally non-polar labelled the larger cells brigthly, but not to the same intensity as the charged probes in the small cells.

Animals↗

A new and potent 2-5A analogue which does not require a 5'-polyphosphate to activate mouse L-cell RNase L.

In order to explore the possibility of supplanting the requirement of a 5'-triphosphate moiety for the activation of the 2-5A-dependent endonuclease (RNase L) of mouse L-cells, two new tetrameric analogues of 2-5A were synthesized. The first tetramer, obtained by both a modified prebiotic synthetic approach as well as a phosphite triester solid phase oligonucleotide synthesis method, was p5'A2'p5'A2'p5'(br8A)2'p5'(br8A). The second oligonucleotide was derived from the former by a sequence involving periodate oxidation, reaction with n-hexylamine, and cyanoborohydride reduction, resulting in conversion of the 2'-terminal adenosine residue to 9-(3'-aza-4'-hexyl-1',2',3',4'-tetradeoxyhexopyranos-1(1)-yl)-8-++ +bromoadenine. Both of these oligomers, bearing only 5'-monophosphate groups, were found to be as potent as 2-5A itself as activators of the RNase L of mouse L-cells.

Adenine Nucleotides↗

Cyclohexylamine inhibits the adhesion of lymphocytic cells to human syncytiotrophoblast.

We have previously shown that lymphocytic cells adhere to cultured syncytiotrophoblast and that this may be important in the lymphocyte-mediated infection of trophoblast with the human immunodeficiency virus (HIV). During the course of studies aimed at investigating the role of cell surface carbohydrates in adhesion, it was discovered that a contaminant of commercial fucose-1-phosphate, dicyclohexylamine, inhibited MOLT-trophoblast adhesion. Dicyclohexylamine and the related compounds, cyclohexylamine and hexylamine, inhibited adhesion in a dose-responsive manner with half-maximal inhibition seen at about 4 mM. While the pressor effects of cyclohexylamine, the principal metabolite of cyclamate, are well known, this is the first report of an effect of this and related compounds on cell adhesion activity. The inhibitory effect was reversible and, at concentrations less than 25 mM, did not result in loss of cell viability. Several possible mechanisms of action of cyclohexylamine were examined in an attempt to explain the effect on adhesion. No evidence was found to suggest that the effects of cyclohexylamine were due to inhibition of polyamine synthesis, increase in intracellular Ca2+ concentration or to a lysosomotropic effect. The concentrations of cyclohexylamine used are within the range of plasma concentrations attainable in humans, raising the possibility that the in vitro effects described here may also occur in vivo. The results also suggest that caution should be used in the interpretation of results obtained from experiments where cell adhesion is blocked using exogenous monosaccharides that are in the form of dicyclohexylammonium salts. Appropriate controls must be included or, if possible, sodium, potassium or barium salts should be chosen.

Cell Adhesion↗

Hyperthermia enhances the in vitro activity of 1-hexylcarbamoyl-5-fluorouracil compared to that of 5-fluorouracil.

The synergic effects on HeLa cells between 1-hexylcarbamoyl-5-fluorouracil (HCFU), a lipophilic masked compound of 5-fluorouracil (5-FU), and hyperthermia were investigated, with the following results: (1) After the cells had been exposed to the drug at 77 microM for 1, 2 or 3 days, with or without heat (43 degrees C) for 2 h, treatment with HCFU and heat inhibited cell growth by 9.2% on day 3, compared to control cells, HCFU alone, heat alone or the combined treatment with 5-FU plus heat. (2) The cells were exposed to the drugs at 77 microM or heat (43 degrees C) for 15-45 min and the colonies counted on day 14. Combined treatment with HCFU plus heat inhibited the clonogenicity of HeLa cells to 22.4% of findings in the control cells and as compared to findings with other treatments. The combination of 5-FU, n-hexylamine and heat had much the same effect as the combined effect of the treatment of HCFU plus heat. (3) Intracellular levels of the drugs did not increase with hyperthermic treatment. Our findings suggest that it is the hexylcarbamoyl structure of HCFU that relates to the synergic effect between HCFU and hyperthermia. This combination is expected to have positive effects for treating patients with malignancy.

Antineoplastic Agents↗

Comparison of high-performance and thin-layer chromatographic methods for the assay of lidocaine.

Reversed-phase high-performance liquid chromatographic (HPLC) and thin-layer chromatographic (TLC)-UV densitometric methods were developed for the quality control of lidocaine hydrochloride bulk drug and its injection solutions. The HPLC method used an RP-18 reversed-phase column with methanol-water-1% phosphoric acid-hexylamine (30:70:100:1.4, v/v/v/v) as the mobile phase and detection at 254 nm, with a capacity factor k' = 0.8. The TLC-UV densitometric method was performed on silica gel plates using diisopropyl ether-acetone-diethylamine (85:10:5, v/v/v) as the developing solvent and UV detection at 254 nm. The response was linear up to 10 micrograms ml-1 (HPLC) and 8 mg ml-1 (TLC). The RSD of the peak areas was 1.71% for HPLC and 0.55% for TLC, with recoveries in the range 99.6-100.2% for HPLC and 99.2-100.7% for TLC.

Chromatography, High Pressure Liquid↗

Effects of KCl-EGTA solution on the isolated Mytilus smooth muscle: a method for denervation.

The ABRM of M. edulis was immersed in KCl-EGTA solution (540 mM KCl + 5 mM EGTA) for 30 min. Then the muscle was returned to normal ASW, effects of the KCl-EGTA solution being examined on the ultrastructure of the neuromuscular junctions and also on the mechanical responses of the muscle to several kinds of stimuli. By the KCl-EGTA treatment of the muscle, synaptic vesicles in the nerve terminals at the junctions were found to be markedly deformed in shape and materially reduced in number. In most of the muscles tested, the contractile response to ACh and catch-relaxing responses to serotonin and dopamine were not depressed by the present treatment, though in some other muscles those responses were depressed a little. Contractile and catch-relaxing responses to repetitive electrical pulses of stimulation were markedly depressed or almost blocked by the treatment. All of the catch-relaxing responses to hexylamine (10(-3)M), phenylethylamine (10(-4)M), Na+-free ASW and 8-bromo-cyclic GMP (10(-3)M) were also markedly depressed or almost completely blocked. These results indicate that the function of intramuscular nerve fibres in the ABRM is markedly impaired by treating the muscle with KCl-EGTA solution while that of muscle fibres is little impaired. The treatment seems to be a useful method for denervation in the isolated ABRM.

8-Bromo Cyclic Adenosine Monophosphate↗

Application of polymethacrylate resin as stationary phase in liquid chromatography with UV detection for C1-C7 aliphatic monocarboxylic acids and C1-C7 aliphatic monoamines.

The application of unfunctionized polymethacrylate resin (TSKgel G3000PWXL) as a stationary phase in liquid chromatography with UV detection for C1-C7 aliphatic monocarboxylic acids (formic acid, acetic acid, propionic acid, butyric acid, isovaleric acid, valeric acid, 3,3-dimethylbutyric acid, 4-methylvaleric acid, hexanoic acid, 2-methylhexanoic acid, 5-methylhexanoic acid and heptanoic acid) and C1-C7 aliphatic monoamines (methylamine, ethylamine, propylamine, isobutylamine, butylamine, isoamylamine, amylamine, 1,3-dimethylbutylamine, hexylamine, 2-heptylamine and heptylamine) was carried out. Using dilute sulfuric acid as the eluent, the TSKgel G3000PWXL, resin acted as an advanced stationary phase for these C1-C7 carboxylic acids. Excellent simultaneous separation and symmetrical peaks for these C1-C7 carboxylic acids were achieved on a TSKgel G3000PWXL column (150 mm x 6 mm i.d.) in 60 min with 0.25 mM sulfuric acid containing 1 mM 2-methylheptanoic acid at pH 3.3 as the eluent. Using dilute sodium hydroxide as the eluent, the TSKgel G3000PWXL resin also behaved as an advanced stationary phase for these C1-C7 amines. Excellent simultaneous separation and good peaks for these C1-C7 amines were achieved on the TSKgel G3000PWXL column in 60 min with 10 mM sodium hydroxide containing 0.5 mM 1-methylheptylamine at pH 11.9 as the eluent.

Amines↗

Separation and conductimetric detection of C1-C7 aliphatic monocarboxylic acids and C1-C7 aliphatic monoamines on unfunctionized polymethacrylate resin columns.

The application of unfunctionized polymethacrylate resin (TSKgel G3000PWXL) as a stationary phase in liquid chromatography with conductimetric detection for C1-C7 aliphatic monocarboxylic acids (formic acid, acetic acid, propionic acid, butyric acid, isovaleric acid, valeric acid, 3,3-dimethylbutyric acid, 4-methylvaleric acid, hexanoic acid, 2-methylhexanoic acid, 5-methylhexanoic acid and heptanoic acid) and C1-C7 aliphatic monoamines (methylamine, ethylamine, propylamine, isobutylamine, butylamine, isoamylamine, amylamine, 1,3-dimethylbutylamine, hexylamine, 2-heptylamine and heptylamine) was attempted with C8 aliphatic monocarboxylic acids (2-propylvaleric acid, 2-ethylhexanoic acid, 2-methylheptanoic acid and octanoic acid) and C8 aliphatic monoamines (1,5-dimethylhexylamine, 2-ethylhexylamine, 1-methylheptylamine and octylamine) as eluents, respectively. Using 1 mM 2-methylheptanoic acid at pH 4.0 as the eluent, excellent separation and relatively high sensitive detection for these C1-C7 carboxylic acids were achieved on a TSKgel G3000PWXL column (150 mm x 6 mm i.d.) in 60 min. Using 2 mM octylamine at pH 11.0 as the eluent, excellent separation and relatively high sensitive detection for these C1-C7 amines were also achieved on the TSKgel G3000PWXL column in 60 min.

Amines↗

Retention behavior of C1-C6 aliphatic monoamines on anion-exchange and polymethacrylate resins with heptylamine as eluent.

Retention behavior of C1-C6, aliphatic monoamines (methylamine, ethylamine, propylamine, butylamine, amylamine and hexylamine) on columns (150 mm x 6 mm i.d.) packed with various anion-exchange resins (styrene-divinylbenzene (PS-DVB) copolymer-based strongly basic anion-exchange resin: TSKgel SAX, polymethacrylate-based strongly basic anion-exchange resin: TSKgel SuperQ-5PW and polymethacrylate-based weakly basic anion-exchange resin: TSKgel DEAE-5PW) and unfunctionized polymethacrylate resins (TSKgel G5000PW and TSKgel G3000PWXL) was investigated with basic solutions (sodium hydroxide and heptylamine) as the eluents. Due to strongly electrostatic repulsion (ion-exclusion effect) between these anion-exchange resins and these amines, peak resolution between these amines on these anion-exchange resin columns was unsatisfactory with both sodium hydroxide and heptylamine as the eluents. In contrast, these polymethacrylate resins were successfully applied as the stationary phases for the separation of these C1-C6 amines with heptylamine as eluent, because of both small hydrophobicity and small cation-exchange ability of these resins. Excellent simultaneous separation, highly sensitive conductimetric detection and symmetrical peaks for these C1-C6 amines were achieved on the TSKgel G3000PWXL column in 35 min with 5 mM heptylamine at pH 11.1 as the eluent.

Amines↗

Sensitive determination of aliphatic amines in water by high-performance liquid chromatography with chemiluminescence detection.

A sensitive method has been developed for liquid chromatographic determination of short aliphatic amines in water samples. Analytes are preconcentrated and dansylated on solid sorbents (C18 solid-phase extraction cartridges). The dansyl derivatives are chromatographed and post-column mixed with peroxyoxalate (TCPO) and H2O2 in order to perform chemiluminescence detection. Optimal results have been obtained using a sample volume of 5 ml. The method has been applied to the quantification or screening of several aliphatic amines: methylamine, ethylamine, butylamine, diethylamine, pentylamine and hexylamine. The screening procedure has been developed including also polyamines (putrescine, cadaverine, spermidine and spermine). The results obtained by using chemiluminescence (CL) detection have been compared with other detection systems (fluorescence and UV). The sensitivity can increase from 3 to 75 times respect UV detection and from 2 to 10 times respect fluorescence detection depending on the amine. The detection limits achieved were between 0.15 and 0.9 microg/l.

Amines↗

Determination of aliphatic amines in mineral flotation liquors and reagents by high-performance liquid chromatography after derivatization with 4-chloro-7-nitrobenzofurazan.

The method described here fulfils the need for a suitable analytical method to determine the concentrations of single and mixed aliphatic amines in the range from hexylamine (C6) to octadecylamine (C18) in flotation test solutions and in commercial flotation collectors. Amines do not have a UV-vis spectrum in aqueous solution but by reacting an amine-containing solution with 4-chloro-7-nitrobenzofurazan solution (chloro-NBD), derivatized products (amino-NBDs) are formed which have absorbance maxima at 470nm. Excess chloro-NBD and the amino-NBDs can be separated from each other by high-performance liquid chromatography (HPLC) and their concentrations measured with a UV-vis detector. Important variables in the derivatization stage are pH, temperature, chloro-NBD concentration, and reaction time, all of which interact with each other. A three-stage statistical procedure was used to determine the optimum conditions. In each stage, an 8-test design was used in which a high and low limit was set for each variable, and the chromatogram peak area of the derived amino-NBD was measured. The optimum derivatization conditions established were pH 8.9, chloro-NBD concentration 0.20% (w/v), temperature 70 degrees C, and reaction time 60 min. Optimum elution conditions for chromatography were an eluent containing 80% (v/v) acetonitrile in aqueous solution containing 40mM acetic acid at pH 4.5. With a flow rate of 2.0 ml/min, dodecylamine had a retention time of about 3 min, whereas octadecylamine had a retention time of 44 min. Straight-line calibration curves were obtained up to at least 200 ppm of amine in solution. The lower limit of detection was estimated to be 0.05 microM (10ppb) with a signal to noise ratio of 3. No interfering substances were found. The method was successfully applied to the analysis of solutions from an actual flotation test and to a solid commercial amine.

4-Chloro-7-nitrobenzofurazan↗

Identification and quantification of (polymeric) hindered-amine light stabilizers in polymers using pyrolysis-gas chromatography-mass spectrometry and liquid chromatography-ultraviolet absorbance detection-evaporative light scattering detection.

Direct analysis of polymers containing polymeric hindered amine light stabilizers (HALS) by using pyrolysis coupled to GC-MS is applied successfully for fast and straightforward identification of these HALS additives. Each of the HALS additives shows different pyrolysis gas chromatograms containing characteristic pyrolysis products. As a result, HALS additives with very similar chemical structures, e.g. Chimassorb 944 and Chimassorb 2020, can be distinguished. A HPLC method with both ultraviolet (UV) and evaporative light scattering detection (ELSD) is developed to quantify the various HALS additives in extracts of polymers. The critical factor of the HPLC method is the use of a basic amine, like n-hexylamine, as a solvent additive to facilitate the elution of HALS additives. The various HALS additives can be distinguished according to retention time and peak shape and by using different detection methods. The suitability of the developed methods is demonstrated by the analytical performance of the HPLC method and the identification and determination of the actual content of HALS additives in polyolefines using pyrolysis GC-MS and HPLC. The HPLC method can also be used for the determination of the specific migration of HALS additives from food contact materials.

Amines↗