PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Immunomagnetic Separation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Immunomagnetic separation of subpopulations of apolipoprotein A-I.

OBJECTIVE: This study was undertaken to measure the subfractions of high-density lipoprotein (HDL) in patients with diabetes or coronary artery disease and in normal control subjects. DESIGN: A new immunomagnetic separation technique was used to characterize the lipid profile in four groups: (1) control subjects, (2) patients with diabetes but no coronary artery disease (CAD), (3) those with CAD only, and (4) those with both diabetes and CAD. MATERIAL AND METHODS: To study the individual roles of the two discrete HDL subpopulations of particles--LpAI/AII (apolipoprotein [apo] A-I associated with A-II) and LpAI (apo A-I without A-II)--in lipoprotein metabolism, we developed an immunomagnetic separation technique using magnetic beads coated with antibodies to human apo A-II. The beads bind particles that contain both apo A-II and apo A-I and are precipitated by a magnetic field. LpAI levels were measured in the supernatant by performing an apo A-I radioimmunoassay. LpAI/AII levels were determined by subtracting the LpAI levels from total plasma apo A-I. RESULTS: In comparison with control subjects, patients with diabetes, CAD, or both had significantly decreased levels of LpAI/AII. LpAI levels were normal in patients with diabetes without CAD but significantly lower than control values in those with diabetes and CAD. CONCLUSION: Our findings suggest that both subpopulations of HDL particles have implications in the development of atherosclerosis in patients with and without diabetes.

Adult↗

Isolation of large and pure samples of human erythroid precursors at different stages of maturation using immunomagnetic separation of cells from liquid cultures.

The two-phase liquid culture, which supports the development of human erythroid progenitors into hemoglobin-containing orthochromatic normoblasts, provides high yield of erythroblasts with synchronized development. However, other cell types are also present in the culture. In the present report, we used immunomagnetic separation for the purification of the developing erythroid precursors. At different stages of the culture, aliquots of the cells were incubated with anti-glycophorin A, B monoclonal antibodies, followed by anti-mouse IgG-coated magnetic beads, and separated by a magnet. In mature cultures, all isolated glycophorin-positive cells contained hemoglobin, as indicated by their staining with benzidine. All glycophorin-negative cells were benzidine negative. In earlier cultures, morphological examination and measurements of hemoglobin content showed that the erythroid precursors could be isolated at different stages of maturation. Thus, the combination of the liquid culture procedure with the immunomagnetic separation technique permitted to obtain large samples of pure erythroid cells, which were synchronized at subsequent stages of maturation. The method enables comprehensive studies of developing erythroid cells from normal donors as well as from patients with various disorders of erythropoiesis.

Blood Proteins↗

Detection and enumeration of Cryptosporidium sp. oocysts in sewage sludge samples from the city of Florianópolis (Brazil) by using immunomagnetic separation combined with indirect immunofluorescence assay.

In the last few decades, agricultural reclamation of sewage sludge has increased in many countries. However, this practice must be adopted under recommended conditions to limit the risks associated with the presence of potential pathogens, including protozoan parasites such as Cryptosporidium. In the present work, we evaluated immunomagnetic separation (IMS) combined with an indirect immunofluorescence assay (IFA) in order to detect Cryptosporidium oocysts in sewage sludge samples obtained from the Municipal Wastewater Treatment Plant (MWTP) operating in the city of Florianópolis, State of Santa Catarina, Brazil. Integrated application of spontaneous sludge sedimentation and centrifugation of the supernatant, purification and concentration of oocysts through immunomagnetic separation as well as detection and quantification by means of indirect immunofluorescence using highly specific monoclonal antibodies, proved to be an effective multiple-analysis tool for monitoring the presence of Cryptosporidium oocysts in urban sewage sludge samples. Among 27 samples collected from MWTP, 20 (74.07%) were positive for Cryptosporidium sp. The efficiency of recovery by using the internal control ColorSeed (Biotechnology Frontiers Inc., Sydney, NSW, Australia) was medially 39.96 +/- 11.20%. Actually, oocysts were recovered from 100% of the positive samples tested and the number of Cryptosporidium oocysts found in the samples ranged from one to four. These results demonstrated a high recovery rate of Cryptosporidium oocysts in sewage sludge samples by using IMS-IFA analysis. In conclusion, such an approach can be applied to monitor the presence of the parasite and to determine the potential contamination of sludge destined for soil application.

Agriculture↗

Detection of Escherichia coli using immunomagnetic separation and bacteriophage amplification coupled with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

The application of whole cell analysis by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has emerged as a valuable tool for rapidly identifying/detecting bacteria. This technique requires minimal sample preparation and is simple to perform, but is generally limited to purified samples of bacteria at concentrations greater than 1.0 x 10(6) cells/mL. In this paper, we describe a bacterial detection method that integrates immunomagnetic separation with bacteriophage amplification prior to MALDI-MS analysis. The developed method consists of three main stages: (1) isolation of a target bacterium by immunomagnetic separation; (2) infection of the immuno-captured bacterium with a lytic bacteriophage; and (3) assay of infected medium for bacteriophage progeny using MALDI-MS to produce a molecular weight signal for the virus capsid protein. With this technique, the presence of Escherichia coli in broth was determined in less then 2 h total analysis time at a concentration of approximately 5.0 x 10(4) cells/mL.

Bacteriophages↗

Comparison of the sensitivity of manual and automated immunomagnetic separation methods for detection of Shiga toxin-producing Escherichia coli O157:H7 in milk.

AIM: To determine the sensitivity of methods for detection of injured and uninjured Escherichia coli O157:H7 (E. coli O157) in raw and pasteurized milk. METHODS AND RESULTS: Raw milk, pasteurized milk with 1.5% fat content and pasteurized milk with 3.5% fat content were spiked with E. coli O157 at low levels. The samples were enriched in modified tryptone soya broth with novobiocin (mTSBn) at 37 degrees C. Aliquots of the enriched culture were analysed either by manual immunomagnetic separation (MIMS) and culturing on sorbitol MacConkey agar with or without cefixime and potassium tellurite (SMACct or SMAC), or by automated immunomagnetic separation and integrated ELISA (EiaFosstrade mark). Uninjured E. coli O157 organisms were detected in milk by both methods at 1 cfu 10 ml-1 sample). Injured organisms were detected at levels of about 4 cfu 10 ml-1 sample. Direct enrichment in mTSBn (22 h incubation) showed better sensitivity for injured cells than enrichment in buffered peptone water (BPW, 22 h incubation), or in a two-step enrichment consisting of BPW (6 h, 37 degrees C) and mTSBn (16 h, 37 degrees C), successively. CONCLUSIONS: The methods showed equal sensitivity in that they were both able to detect 1 cfu 10 ml-1 milk sample. Injured organisms can be detected and isolated at a level almost as low as this. A resuscitation step is not recommended for the detection and isolation of injured and non-injured E. coli O157 from milk. SIGNIFICANCE AND IMPACT OF THE STUDY: Due to the dilution of contamination in the bulk tank, analysis of milk for the presence of E. coli O157 requires a very sensitive method. Both methods described here are useful for such analysis.

Animals↗

Improved isolation of Escherichia coli O157 using large enrichment volumes for immunomagnetic separation.

The recovery of low numbers of Escherichia coli O157 in foods by immunomagnetic separation (IMS) was improved, on average, ninefold by increasing the enrichment volume tested from 1 to 10 ml while maintaining the volume of immunobeads constant at 0.02 ml. Although 50 ml volumes also gave improved recoveries (approximately threefold), the 50 ml volume cannot be recommended until a suitable magnetic separation apparatus has been developed. By testing 10 ml volumes, the improved sensitivity of the IMS procedure will reduce false-negative E. coli O157 tests and help improve epidemiological studies of this pathogen.

Animals↗

Serodiagnosis of human plague by a combination of immunomagnetic separation and flow cytometry.

BACKGROUND: Plague is a severe, highly communicable bacterial disease caused by Yersinia pestis. It is still endemic in more than 20 countries worldwide. Although known as a devastating disease for centuries, laboratory confirmation of clinical suspected cases is still problematic. No standardized and internationally approved test system is commercially available. The aim of this study was the introduction and evaluation of a combination of immunomagnetic separation and flow cytometry for the serodiagnosis of human plague. METHODS: Paramagnetic polystyrene beads were coated with purified F1 capsular antigen (F1 CA) and reacted with sera from plague patients, from 26 laboratory personnel vaccinated against plague and from 102 healthy blood donors (HBD). After incubation with fluorescein isothiocyanate-conjugated anti-human rabbit IgG, particle-associated fluorescence was detected by flow cytometry. RESULTS: Anti-F1 CA antibodies could be demonstrated in all patients with bacteriologically confirmed plague and in 22 sera (84.6%) from vaccinees. Only one serum in the HBD group showed a weakly positive reaction. The total assay time was less than 2 h. CONCLUSIONS: Compared with a recently published combination of an anti-F1 CA enzyme-linked immunosorbent assay (ELISA) and immunoblot, the new assay showed the same sensitivity as the ELISA and almost the same specificity (99.0 versus 100%) as the immunoblot. Allowing a rapid, reliable, and quantitative analysis, immunomagnetic separation combined with flow cytometry might replace both conventional immunoassays.

Antibodies↗

Evaluation of immunomagnetic separation for recovery of infectious Cryptosporidium parvum oocysts from environmental samples.

Two commercial immunomagnetic separation (IMS) kits for Cryptosporidium were compared for recovery of oocysts from environmental samples. Oocyst recovery efficiencies with the Dynal and Crypto-Scan kits ranged from 62 to 100% and 34 to 74%, respectively, for seeded environmental water concentrates (turbidity of 210 to 11,480 nephelometric turbidity units). Recovery efficiencies were dependent on the mechanism of agitation during the magnetic capture procedure. An assay combining in vitro cell culture and reverse transcriptase PCR demonstrated that oocysts recovered by IMS retained their infectivity.

Animals↗

Evaluation of immunomagnetic separation method for detection of Giardia for different reaction times and reaction volumes.

Immunomagnetic separation (IMS) has been specified as a standard method for the measurement of Giardia. In this study, Dynal IMS was evaluated on the basis of recovery efficiencies of Giardia cysts for various IMS operational conditions. The average recoveries for Giardia in deionized, treated and raw water samples were 82.6 +/- 12.2% (n = 6), 75.6 +/- 15.2% (n = 3), and 70.6 +/- 18.2% (n = 3), respectively. Significant changes in recovery were observed by altering the debris ratio and the debris components of water samples. Changing the reaction volume within the same vessel had no significant effect on cyst recovery efficiencies. However, prolonging the reaction time did increase recovery efficiencies.

Animals↗

Evaluation of an automated immunomagnetic separation method for the rapid detection of Salmonella species in poultry environmental samples.

Automated immunomagnetic separation (AIMS), using Dynabeads anti-Salmonella (Dynal, Oslo), was evaluated for its ability to detect Salmonella spp. in poultry environmental samples in comparison with standard, culture-based method (Health Canada, Health Protection Branch, MFHPB-20). AIMS was found to be more reliable in detecting Salmonella from artificially inoculated enrichment broths at low levels and exhibited a 15.5% higher sensitivity value than the culture method.

Animals↗

Detection of pathogenic Yersinia enterocolitica in foods and water by immunomagnetic separation, nested polymerase chain reactions, and colorimetric detection of amplified DNA.

A two-step polymerase chain reaction (PCR) procedure with two nested pairs of primers specific for the yadA gene of Yersinia enterocolitica was developed. The PCR assay identified all common pathogenic serogroups (O:3, O:5,27, O:8, O:9, O:13, and O:21) from three continents and differentiated pathogenic Y. enterocolitica from Y. pseudotuberculosis and from a variety of nonpathogenic yersiniae representing 25 serogroups and four species. The performance of the method was evaluated with seeded food and water samples. We compared two procedures for sample preparation prior to PCR: one was based on immunomagnetic separation of the target bacteria from the sample, using magnetic particles coated with immunoglobulin antibodies to Y. enterocolitica serogroup O:3, and the other method consisted of a series of centrifugation steps combined with proteinase treatment. Regardless of the method used, the PCR assay was capable of detecting 10 to 30 CFU/g of meat in 10(6)-fold excess of indigenous bacteria. When the samples were enriched overnight in a nonselective medium, the sensitivity was increased to approximately 2 CFU/g, except for samples with an extremely high background flora (> 10(7) CFU/g). We compared gel electrophoretic detection of PCR products with a colorimetric detection method designated DIANA (detection of immobilized amplified nucleic acids), which enabled easy visualization of amplified fragments in a microtiter plate format with an optical density reader. DIANA and gel electrophoresis showed complete concordance in their discrimination between positive and negative samples. The combination of immunomagnetic separation, nested PCR, and DIANA makes possible the development of a fully automated analytic process which requires a minimum of laboratory manipulations.

Adhesins, Bacterial↗

Isolation of Actinobacillus pleuropneumoniae serotype 2 by immunomagnetic separation.

In Denmark porcine pleuropneumonia is most frequently caused by Actinobacillus pleuropneumoniae serotype 2 (60%). Isolation of A. pleuropneumoniae from nasal cavities or tonsils from carrier animals is complicated due to the mixed bacterial flora present. An immunomagnetic separation technique (IMS) using immunomagnetic beads (Dynabeads((R))) was developed for isolation of A. pleuropneumoniae serotype 2 from pure cultures and from heterogeneous suspensions. Different coating and washing procedures were evaluated in pure and mixed cultures using polyclonal (PAb) and monoclonal antibodies. The highest reisolation yield was achieved when the beads were coated with 1.5 microg PAb IgG/10(7) beads. After washing the beads for four times 9-24% of the bacteria could be reisolated depending on the amount of IgG attached to the beads and the number of beads used. The recovery was increased to 19-61% when only two washing steps were performed. The IMS was further evaluated using dilutions of A. pleuropneumoniae with added Pasteurella multocida (10(9) CFU/ml). After two washing steps 15% of the A. pleuropneumoniae cells and no P. multocida was reisolated. A detection limit of 10 CFU/ml was found in this heterogeneous suspension. No significant difference was observed when comparing the recovery of A. pleuropneumoniae from pure culture, from mixed cultures and from artificially inoculated tonsils. From 12 pigs inoculated with an aerosol of A. pleuropneumoniae serotype 2 the bacterium could not be detected from the nasal cavity or tonsils by cultivation or PCR 6 weeks later. By using IMS A. pleuropneumoniae serotype 2 could be reisolated from the tonsils of three pigs. The IMS method represents a valuable tool for isolation of A. pleuropneumoniae from tissue samples.

Actinobacillus Infections↗

An immunomagnetic separation polymerase chain reaction assay for rapid and ultra-sensitive detection of Cryptosporidium parvum in drinking water.

A sensitive and rapid method was developed to detect Cryptosporidium parvum oocysts in drinking water. This molecular assay combined immunomagnetic separation with polymerase chain reaction amplification to detect very low levels of C. parvum oocysts. Magnetic beads coated with anti-cryptosporidium were used to capture oocysts directly from drinking water membrane filter concentrates, at the same time removing polymerase chain reaction inhibitory substances. The DNA was then extracted by the freeze-boil Chelex-100 treatment, followed by polymerase chain reaction. The immunomagnetic separation-polymerase chain reaction product was identified by non-radioactive hybridization using an internal oligonucleotide probe labelled with digoxigenin. This immunomagnetic separation-polymerase chain reaction assay can detect the presence of a single seeded oocyst in 5-100-1 samples of drinking water, thereby assuring the absence of C. parvum contamination in the sample under analysis.

Animals↗

Detection of Cryptosporidium parvum oocysts in sediment and biosolids by immunomagnetic separation.

A method for the detection of Cryptosporidium parvum oocysts in sediment and wastewater biosolids has been developed using immunomagnetic separation kits that were designed for use with water. This method requires no pretreatment of the sediment or biosolids samples before the commercial kit application. Oocyst recovery efficiencies from sediment and biosolids using the modified Dynal (Lake Success, New York) and Crypto-Scan commercial methods (Immucell Corporation, Portland, Maine) ranged from 20 to 60%. While the sensitivity of the method is dependent on the amount of sediment processed and the equivalent volume examined under the microscope, it was able to detect 0.48 oocysts per gram dry weight sediment. Using this method, Cryptosporidium parvum oocysts were found at levels as high as 97 oocysts/g of primary biosolids and at levels up to 4 oocysts/g in polluted sediment.

Animals↗

[Coupling of immunomagnetic separation and polymerase chain reaction for the rapid detection of salmonellae in minced meat and chicken giblets].

Coupling of immunomagnetic separation and polymerase chain reaction was used after preenrichment for the rapid detection of salmonellae in minced meat and chicken giblets. The primers used are specific to the origin of DNA replication (oriC) on the Salmonella chromosome and produce a 163 bp DNA fragment. The method allowed a screening of Salmonella free samples within 24 hours. It detected 5 serovars when inoculated in minced meat at a contamination level of 1 to 4 cfu/g. Compared with the method L 00.00-20 of the Official Collection of Methods of Analysis according to section 35 of the German Law on Food and Commodities it showed a sensitivity of 94% and a specificity of 87.5% for the examination of chicken giblets (n = 45) and a specificity of 100% for the examination of minced meat (n = 63).

Animals↗

[A comparison of sensitivity between direct plate culture, immunomagnetic separation and polymerase chain reaction for the isolation of enterohemorrhagic Escherichia coli O157].

Sensitivities of direct plate culture (DPC) method, immunomagnetic separation (IMS) method, and polymerase chain reaction (PCR) assay for successful detection Escherichia coli O157 in the food samples were compared. Three lots of minced beef and three lots of radish sprout, both of which were commercially retailed, were enriched with non-selective broth media at 36 degrees C for 6 h. After enrichment, the cultures of the minced beef and those of the radish sprout were found to have background microflora at ca.10(5)-10(7) CFU/ml and ca.10(8) CFU/ml, respectively. The cultures were then experimentally inoculated with E. coli O157 strains at various final concentrations ranging from ca.10 to 10(7) CFU/ml. The samples thus prepared were subjected to the above three methods to evaluate their detection limits. For the samples of minced beef, the detection limits of the DPC method was 10(2) CFU/ml whilst that of the IMS method was ca.10 CFU/ml. For the samples of radish sprout, the detection limits of the DPC method, the IMS method, and the PCR assay were ca.10(4) CFU/ml, ca.10(2) CFU/ml, and ca.10(6) CFU/ml, respectively. There results strongly suggest that the IMS method is most sensitive method for the detection of O157 from food samples among the methods currently available.

Bacteriological Techniques↗

Optimizing enrichment conditions for the isolation of Escherichia coli O157 in soils by immunomagnetic separation.

AIMS: To compare a range of enrichment broths and enrichment temperatures for the isolation of Escherichia coli O157 by immunomagnetic separation (IMS) from sandy, loam and clay soils. METHODS AND RESULTS: Soils were spiked with cocktails of four atoxigenic strains of E. coli O157 and four strains of commensal E. coli. The organisms were stressed by subjecting soils to cycles of freeze/thawing, followed by drying at 20 degrees C for up to 4 days. Nine enrichment broths were trialled based on buffered peptone water, tryptone soya broths and EC broths supplemented with a range of selective additions. Enrichments were incubated for 6 h and assessed by target recovery after IMS on cefixime tellurite sorbitol MacConkey agar (CTSMAC) incubated at 37 degrees C for 24 h. A comparison of enrichment temperatures (37 and 42 degrees C) was also performed. Buffered peptone water (with or without vancomycin) and tryptone soya broth (with or without novobiocin) gave significant increases in recovery of E. coli O157 compared to others tested. In addition, broths incubated at 42 degrees C were superior to those at 37 degrees C for the recovery of E. coli O157. SIGNIFICANCE AND IMPACT OF THE STUDY: This study showed that sub-lethally damaged E. coli O157 surviving in soil can be sensitive to antimicrobial additions. The choice and concentration of these additions is vitally important to optimize target recovery. Some IMS protocols, established for the isolation of E. coli O157, may be unsuitable for the examination of soil samples.

Bacteriological Techniques↗

Rapid detection of stressed Salmonella spp. in dairy and egg products using immunomagnetic separation and PCR.

The rapid detection of an average of 5.9 stressed Salmonella cells in 25 g of food product using immunomagnetic separation (IMS) and PCR is described. For pasteurised egg yolk, egg yolk powder, ice-cream, whole egg, egg white and cheeses made from pasteurised milk PCR was applied after 16 h of preenrichment in buffered peptone water (BPW) using IMS and alkaline lysis as sample preparation method. For whole egg and egg white the BPW was supplemented with iron. For milk powder, and raw milk cheeses, the 16-h preenrichment in BPW was followed by IMS and a 4-h enrichment in Rappaport-Vassiliadis broth. In the latter case, PCR was applied on the enrichment medium after centrifugation and alkaline lysis. For PCR the primers ST11 and ST15 (Aabo et al., 1993) producing a fragment of 429 bp were used. An internal PCR control, designed to be co-amplified with the target DNA using the same primers but producing a smaller fragment of 240 bp, was used.

Base Sequence↗