PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Ion-Selective Electrodes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

[A potentiometric determination of iodide in milk by use of the iron--selective electrode (author's transl)].

A method for quantitative determination of iodide in milk by use of the ion-selective electrode is described. The proposed method is rapid and simple. No sample pretreatment is required exept for sample ionic strength adjustment. It was possible to determine iodide concentrations down to 40 microgram/l with average relative standard deviation of 3,4%. The concentration of iodide in milk samples determined by this method ranged from 61,5 microgram J-/l to 190,8 microgram J-/l.

Animals↗

A simplified method for measurement of Ca++-activity in serum, using serum-monovettes and a Ca++-selective disk-electrode.

A simplified method for the anaerobic measurement of ionized calcium in serum of venous blood by use of ion-selective electrodes--the monovette-technique--is described. For estimation of Ca++ a new electrode type--the disk-electrode (11, 12, 13, 14)--charged with a synthetic, electrically neutral Ca++-carrier of the octandioic acid-type (1), is tested.

Blood Chemical Analysis↗

Continuous-flow analysis of ammonia in perchloric acid supernate of blood or plasma using an ammonia-selective electrode.

A simple automated method for the estimation of ammonia in perchloric acid supernate of blood or plasma using an ion-selective electrode (Orion Ammonia-selective electrode, Model 95-10) is described. The reliability of the proposed method has been checked against an ion-exchange resin procedure, which has been chosen as a standard procedure. Regression equation and correlation coefficient for the proposed method are y = 0.7 X + 10 and 0.945, respectively, as compared with the chosen standard method. Within-run and between-run precision are 2.1% and 3.5% respectively. The average percent recovery is 97.5% and a tentative range is 13-73 microgram/dl (9-52 micronmol/l) ammonia nitrogen.

Adult↗

Interaction of amino acids with silver(I) ions.

The reactivity of silver(I) ions towards twenty amino acids has been studied in aqueous unbuffered solutions using an ion-selective electrode as a highly sensitive monitor. Contrary to general belief, silver ions are not completely specific for cysteine, but also react with lysine, arginine, methionine and, to a minor extent, cystine. Nevertheless the interaction with all of these species except cysteine is too weak to affect significantly the determination of thiol in proteins by the customary argentometric titration method. The possible origin of errors arising in such titrations is discussed.

Amino Acids↗

Pathophysiological mechanisms of brain edema development: role of tissue factors.

In experiments carried out on adult rabbit "chest-head" preparations the volume changes of the exposed brain (BrV) were determined in repeated tests during a controlled increase of the systemic venous pressure (SVP) of about 13 mm Hg. The changes of both SVP and BrV were usually parallel at the onset of the experiments, but when the brains became preedematous hysteresis appeared in the plots of their relationships. The hysteresis increased gradually (sometimes with periods of partial decrease) thus indicating a delay in the draining of blood from the brain's venous system and in the removal of excess extracellular fluid from the cebral tissue. Evidence for water filtration through the capillary walls during increase of the SVP, and, thus, of brain intravascular pressure, was obtained by detecting the dynamics of [Na+] and [K+] in the extracellular fluid of the cerebral cortex by ion-selective electrodes. This process appeared reversible in normal brains while in the preedematous ones the excessive water filtration resulted in brain edema. The preedematous state of the brain is believed to be caused by changes of the mechanical properties of brain tissue and/or by changes in osmolarity.

Animals↗

Measurement of ionised calcium in body fluids-a review.

This paper reviews the techniques available to the clinical biochemist for measuring ionised calcium concentrations in biological fluids with particular reference to serum. At present ionised calcium may be measured colorimetrically, using tetramethyl murexide, or potentiometrically, using a calcium ion-selective electrode. These techniques compare favourably in terms of precision with existing methods for measuring total calcium. Advantages of measuring ionised calcium in preference to total calcium are (a) that there is no effect of venous occlusion or change of posture on the ionised fraction of the effect on total calcium, (b) that ionised calcium is the physiologically active form of the element, and (c) that the ionised calcium concentration is a more reliable indicator of the calcium status of patients in certain clinical conditions. The main problem in the measurement of ionised calcium is the marked dependence of the ionised fraction of the pH of the sample. Extreme care must be taken to avoid loss of CO2 or build-up of acid during the handling of the blood sample.

Blood Specimen Collection↗

Calcium measurements in serum and plasma--total and ionized.

This article will review the methods currently employed for measuring the concentrations of total and ionized calcium in serum or plasma. As far as total calcium is concerned, various techniques such as atomic absorption spectrometry, spectrophotometry, fluorometry, complexometric titration, and flame photometry will be described and compared. Particular emphasis will be given to the accuracy and precision of each technique. Possible sources of error and interfering agents will be identified and the various procedures for the taking and handling of blood samples evaluated. Inter-laboratory variation in the measurement of calcium will be studied. An assessment will be made of a new reference method for measuring total calcium in serum using isotope-dilution mass spectrometry. The usefulness of the total calcium measurement in clinical medicine will be briefly discussed. Within the last decade the refinement of spectrophotometric techniques and the improvements in ion-selective electrode technology have revolutionized the measurement of ionized calcium in serum, such that it may now be possible to replace total calcium measurements with ionized calcium measurements on a routine basis. The various techniques currently in use for measuring ionized calcium will be described and evaluated. Particular attention will be paid to the preparation of standards, the procedures for taking blood samples, and the handling of the samples prior to and during measurement. An assessment of the relative value of measuring total and ionized calcium will be presented.

Calcium↗

[Coupled transport of K+, Cl-, H+ and OH- ions in a liposome suspension].

By means of the system of ion-selective electrodes the coupling transport of K+, H+ and Cl- ions in liposome suspension was studied. Nigericin and tributyl tin (TBT) were used as inductors of cation and anion exchange. Effect of pH gradient created on the membrane on ionic transport was studied. The latter was shown to control the antiport exchange of both, cations and anions. At the joint effect of nigericin and TBT the yield of K+ and Cl- ions from liposomes independent of the pH gradient was observed.

Biological Transport↗

Measurement of free calcium ion in capillary blood and serum.

We describe a new calcium ion-selective electrode for measurement of the substance concentration of free calcium ion [Ca2+] in the plasma phase of whole blood and in serum at 37 degrees C. A sample volume of 50 microliter suffices to obtain simultaneous values of pH and [Ca2+]. We found the within-series analytical standard deviation for serum to be 0.013 mmol/litre (CV, 1.1%) and day-to-day precision to be 0.022 mmol/litre (CV, 1.7%). The reference interval for [Ca2+] (at pH 7.40) in serum was found to be 1.184 +/- 0.054 mmol/litre (2 SD) from measurements on sera from 121 healthy blood donors. Measurements on capillary blood from 29 healthy volunteers gave a mean (+/- 2 SD) value for [Ca2+] (at pH 7.40) of 1.22 +/- 0.072 mmol/litre.

Bicarbonates↗

[New diagnostic examinations in patients with urinary calculi, taking into consideration primary hyperparathyroidism].

The serum levels of total calcium and anorganic phosphate have been the leading parameters in the diagnosis of primary hyperparathyroidism. In addition to these, it is now possible to measure ionized calcium (Ca++) by an ion-selective electrode and parathormone (PTH) by C- and N-terminal radioimmunoassays (RIA). Whereas Ca++ determination and C-terminal PTH RIA represent a diagnostic progress, this can not be claimed for the N-terminal PTH RIA in peripheral venous blood especially in border-line cases.

Calcium↗

[K-strophanthin-beta complexing with calcium, magnesium and dysprosium ions].

Nuclear magnetic resonance, microcalorimetry and the use of the ion-selecting electrode evidenced that k-strophanthine-beta forms complexes with the calcium, magnesium and disprosium ions. Changes in the position of the k-strophanthine-beta carbohydrate parts and aglycones signals bear witness to their participation in the complexing.

Calcium↗

On-line continuous potentiometric measurement of potassium concentration in whole blood during open-heart surgery.

We describe a flow-through system with an ion-selective electrode for measurement of blood potassium ion concentration, continuously and on-line off the extracorporeal blood circulation in an operating theater during human open-heart surgery. Comparison measurements were made with the SMA flame photometer (blood plasma) and an Orion SS 30 sodium/potassium analyzer (whole blood). The potassium concentration values obtained with the flow-through system agree well with the ones determined with the flame photometer. The time delay of the measurement with the flow-through system was relatively long (2 min) but delays of only 10--20 s seem feasible. Short time delays can deepen insight and simplify rational treatment under surgery conditions.

Autoanalysis↗

Differential effects of cortical speading depression on epileptic foci induced by various convulsants.

Interaction between epileptic foci and spreading depression (SD) was studied in the cerebral cortex of rats anesthetized with Nembutal. At comparable discharge rates, picrotoxin and penicillin caused complete and partial SD blockade respectively, strychnine and Metrazol were ineffective and Aldactone facilitated SD. Conversely, the duration of SD-induced blockade of epileptic activity was maximal for Aldactone and minimal for picrotoxin. Treatment of the picrotoxin focus with tetrodotoxin (10(-4)M) reduced the discharge rate and reinstated SD propagation into the focus. [K+]e measured with ion-selective K+ electrodes 1 mm below the cortical surface increased to 8 mM in penicillin foci blocking SD and remained below 5 mM in Aldactone foci. It is concluded that the differential effect of various convulsants on SD propagation depends on the potassium concentration in the depth of the focus rather than on the discharge rate or on the mechanism of the the epileptogenic effect.

Animals↗

[Ammonium-selective disc-electrode with the carrier-antibiotic nonactin. A method for the continuous enzymatic, electrochemical determination of urea, I (author's transl)].

An ammonium-selective disc-electrode is described; the membrane consists of a polyvinylchloride-matrix with an active phase of nonactin in tris (2-ethylhexyl)phosphate and diphenyl ether as the ion-selective plastic. One side of the membrane is in contact with the solution to be measured and the other with the front surface of a platinum wire, which is enclosed in acrylic glass. This arrangement results in a very low drift potential.

Anti-Bacterial Agents↗

Physicochemical properties of a liquid ion exchanger microelectrode and its application to biological fluids.

Double-barreled potassium or chloride ion-selective microelectrodes were constructed using a liquid ion exchanger. Technical details of the fabrication of double-barreled microelectrodes, having a PD sensor as one barrel and an ionic sensor as the other, are described. The sensitivity of K+ or CI- ion-selective microelectrodes exhibited an approximately Nernstian response over a temperature range of 7 degrees-37 degrees C, and the electromotive force (EMF) was stable within +/- mV for a few hours. The rise time was less than 1 sec. The effect of pH on the electrode response was negligible over a physiological range of pH 5.6 to 7.8. The selectivity constants of the K+ microelectrode to other cations were 0.011 for Na+, 0.200 for NH+4, and less than 0.002 and 0.001 for Ca++ and Mg++, respectively, while that of the CI- microelectrode was 0.067 for HCO-3. Glucose or urea has no effect on the EMF. Protein has a significant effect on ion exchanger membrane only when the concentration of the tested ion is low and protein is high. On the basis of this background the determination of K+ and CI- activity was carried out both in vivo and in vitro on several biological samples, such as serum, tissue and cellular fluids, and other protein-containing fluids. The values obtained with the microelectrode were consistent with those obtained with the other conventional methods or with the current theory on electrolyte solutions. These results were taken to assure the practical application of these electrodes to biological studies in many fields.

Animals↗

Intracellular gradients of ion activities in the epithelial cells of the Necturus gallbladder recorded with ion-selective microelectrodes.

In Necturus gallbladder epithelial cells the intracellular electrical potential, as recorded with microelectrodes, varied from -28 mV in the mucosal end to about -50 mV in the serosal end of the transporting cell. The Na+ activity varied concurrently from about 39 mM to between 8 and 19 mM. Thus, within the cell both the recorded electrical and chemical gradients caused Na+ to move towards the serosal end. Serosal addition of ouabain (5 X 10(-4) M) caused the intracellular Na+ activity to attain electrochemical equilibrium within 30 min. However, the intracellular electrical potential gradient was only slowly affected. In cells from animals stored at 5 degrees C, the Cl- activity varied from about 55 mM in the mucosal end to 28 mM in the serosal end, and the K+ activity from 50 mM to between 95 and 131 mM. Both ions were close to electrochemical equilibrium within the cytoplasm but were too concentrated to be in equilibrium with the mucosal solution. Bubbling CO2 through the mucosal solution caused the intracellular gradients to vanish. When Na+ in the bathing solutions was exchanged for K+, the intracellular electrical potential became roughly constant at about -5 mV. The Cl- activity became constant in 65 mM, and the K+ activity became constant at 109 mM, both close to equilibrium with the mucosal solution. The Na+ activity was reduced to about 1 mM. The ratio of cytoplasmic resistivities between cells bathed in K+-rich saline to cells bathed in Na+-rich saline was measured by means of triple-barreled electrodes and compared to the same ratio as assessed from the activity measurements. The two values were equal only if one assumes the mobility of Na+ inside the cell to be less than 1/10 of the mobility of K+ or Cl-. The same conclusion was reached by comparing the intracellular Na+ flux calculated from the gradient of electrochemical potential to that flux assess from the net solute absorption. Animals kept at 15 degrees C had lower intracellular Na+ activities, higher Cl- and K+ activities, and higher rates of absorption than animals stored at 5 degrees C. Finally, the degree to which the intracellularly recorded electrical and chemical potentials could reflect an electrode artefact is discussed.

Animals↗