PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isothermal amplification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Real-time quantitative LAMP (loop-mediated isothermal amplification of DNA) as a simple method for monitoring ammonia-oxidizing bacteria.

Loop-mediated isothermal amplification (LAMP) of DNA is a novel technique for the amplification of DNA under isothermal conditions. For the first time, we applied this method to develop a simple and quantitative monitoring method for environmental microorganisms targeting amoA gene in ammonia-oxidizing bacteria. Quantitative analysis was performed first by measuring fluorescence derived from an intercalation dye using a real-time thermal cycler, and then by measuring the turbidity of the reaction solution using a real-time turbidimeter. As a result, it was possible to quantify the initial amoA DNA concentration from an environment with a sensitivity down to 10(2) DNA copies of target DNA and a dynamic range of 7-9 orders in magnitude. Background DNA from nontargeted bacteria (Pseudomonas denitrificans) that does not encode amoA gene did not affect the quantitative capability of LAMP. Over results suggested that the real-time LAMP is effective for monitoring microorganisms and their gene expression in environments.

Ammonia↗

Rapid and reliable diagnosis of mucormycosis using colorimetric loop-mediated isothermal amplification.

Current diagnostic approaches for mucormycosis are often limited by low sensitivity and prolonged turnaround times, which result in delayed treatment and poor clinical outcomes. We developed a novel diagnostic method utilizing a colorimetric loop-mediated isothermal amplification (LAMP) assay for the rapid and sensitive detection of mucormycosis. The assay incorporates specifically designed primers capable of detecting as low as 0.001 picograms (pg) of spiked genomic DNA from Mucorales fungi. This LAMP assay demonstrated a high sensitivity of 98% and a 100% specificity of detecting fungal ribosomal DNA (rDNA) in bronchoalveolar lavage (BAL) samples collected from mice infected with Mucorales fungi (n = 48) or from an uninfected control group (n = 15). To align the assay with clinical antifungal therapy, a subset of infected mice was treated with either liposomal amphotericin B (LAMB) or a combination of LAMB and a humanized monoclonal antibody (VX-01) targeting the Mucorales-specific surface protein CotH3. Consistent with the treatment efficacy, the LAMP assay detected significantly lower fungal burdens in BAL samples from mice receiving the combination therapy compared to those treated with LAMB alone or placebo. Further validation was conducted using BAL samples from patients diagnosed with mucormycosis (n = 24) or aspergillosis (n = 17). The assay demonstrated a sensitivity of 79% and a specificity of 94%. These findings highlight the diagnostic potential of this LAMP-based assay as a point-of-care. Its high sensitivity, specificity, and rapid turnaround time position this assay as a promising tool for early and accurate detection of mucormycosis, with the potential to improve patient management and clinical outcomes.IMPORTANCEMucormycosis is a rapidly progressive and fatal fungal infection. Timely diagnosis is critical for effective treatment, yet current diagnostic tools are slow, insensitive, or require complex laboratory procedures. In this study, we developed and validated a colorimetric loop-mediated isothermal amplification (LAMP) assay that enables rapid and reliable detection of Mucorales DNA directly from bronchoalveolar lavage (BAL) specimens. The assay demonstrated high sensitivity and specificity in both experimental mouse models and clinical samples, producing results within 1 h without the need for sophisticated equipment. This simple, robust, and cost-effective molecular diagnostic tool holds great potential for early detection of mucormycosis, facilitating prompt antifungal therapy and improving patient survival.

Mucormycosis↗

Development of loop-mediated isothermal amplification (LAMP) method for diagnosis of equine piroplasmosis.

Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid method whereby DNA is amplified with high specificity, efficiency, and rapidity under isothermal conditions using a set of four specifically designed primers and a DNA polymerase with strand displacement activity. In this study, we used LAMP primer sets designed from EMA-1 and Bc 48 genes for detection of Theileria equi and Babesia caballi infections, respectively. These primer sets specifically amplified DNA of the respective parasites. Both primer sets amplified T. equi and B. caballi up to 10(-6) dilution of 10-fold serially diluted samples. Furthermore, DNA extracted from blood collected from a horse experimentally infected with T. equi was amplified by a T. equi LAMP primer set from days 2 to 35 post-infection, demonstrating the high sensitivity of these primers. Of 55 samples collected from China, 81.8% and 56.3% were positively detected by LAMP for T. equi and B. caballi infections, respectively. In contrast, 91.8% and 45.9% of the 37 samples collected from South Africa were LAMP positive for T. equi and B. caballi, respectively. These results suggest that LAMP could be a potential diagnostic tool for epidemiological studies of equine piroplasmosis.

Animals↗

Loop-mediated isothermal amplification for the rapid detection of Salmonella.

Loop-mediated isothermal amplification (LAMP) assay detected Salmonella within 60 min. The 220 strains of 39 serotypes of Salmonella subsp. enterica and 7 strains of Salmonella enterica subsp. arizonae were amplified, but not 62 strains of 23 bacterial species other than Salmonella. The sensitivity of the LAMP assay was found to be >2.2 cfu/test tube using nine serotypes. The specificity was similar to that of a PCR assay, but the sensitivity of LAMP was greater. Both fluorescence and turbidity were able to detect the products in the LAMP assay. S. enteritidis in a liquid egg sample artificially inoculated with the organism was detected by the LAMP assay at 2.8 cfu/test tube, although negative by PCR assay. These results indicate that the LAMP assay is a rapid, specific and sensitive detection method for Salmonella.

Bacteriological Techniques↗

Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection.

We developed a rapid and sensitive diagnosis system for H5N1 highly pathogenic avian influenza (HPAI) virus infection using an unique gene amplification method, reverse transcriptase loop-mediated isothermal amplification (RT-LAMP). The sensitivity of the system was found to be 100-fold higher than that of ordinary one-step RT-PCR. Moreover, by using viral RNAs extracted from influenza viruses of all 15 HA subtypes, the RT-LAMP system was confirmed to amplify only the RNA of H5 subtype virus. In the surveillance of H5N1 virus infection of wild birds, we detected two positive cases from dead crows found near the affected area with H5N1-HPAI by using RT-LAMP system, although one of two positive cases was missed by RT-PCR. These results suggested that our newly developed RT-LAMP system specific for H5 virus would be a beneficial diagnostic tool for surveillance of recent outbreaks caused by H5N1-HPAI viruses.

Animals↗

Loop-mediated isothermal amplification of DNA.

We have developed a novel method, termed loop-mediated isothermal amplification (LAMP), that amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions. This method employs a DNA polymerase and a set of four specially designed primers that recognize a total of six distinct sequences on the target DNA. An inner primer containing sequences of the sense and antisense strands of the target DNA initiates LAMP. The following strand displacement DNA synthesis primed by an outer primer releases a single-stranded DNA. This serves as template for DNA synthesis primed by the second inner and outer primers that hybridize to the other end of the target, which produces a stem-loop DNA structure. In subsequent LAMP cycling one inner primer hybridizes to the loop on the product and initiates displacement DNA synthesis, yielding the original stem-loop DNA and a new stem-loop DNA with a stem twice as long. The cycling reaction continues with accumulation of 10(9) copies of target in less than an hour. The final products are stem-loop DNAs with several inverted repeats of the target and cauliflower-like structures with multiple loops formed by annealing between alternately inverted repeats of the target in the same strand. Because LAMP recognizes the target by six distinct sequences initially and by four distinct sequences afterwards, it is expected to amplify the target sequence with high selectivity.

Base Sequence↗

Detection of human influenza A viruses by loop-mediated isothermal amplification.

Here we describe the use of the loop-mediated isothermal amplification (LAMP) method to detect human influenza viruses (H1 to H3). Our results were correlated 100% with results deduced from routine clinical diagnostic tests. In addition, we also developed a LAMP assay specific for human beta-actin cDNA as a quality control test.

Actins↗

Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of Mycoplasma pneumoniae.

A loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Mycoplasma pneumoniae was developed and evaluated. The assay specifically amplified only M. pneumoniae sequences, and no cross-reactivity was observed for other Mycoplasma species or respiratory bacterial species. The detection limit for this assay was found to be 2 x 10(2) copies, corresponding to 2-20 colour changing units of M. pneumoniae in 1 h, as observed in a real-time turbidimeter and electrophoretic analysis. The accuracy of the LAMP reaction was confirmed by restriction endonuclease analysis as well as direct sequencing of the amplified product. The assay was applied to 95 nasopharyngeal swab samples collected from patients or from healthy individuals, and compared to a real-time PCR assay in-house. A concordance of 100% was observed between the two assays. The LAMP assay is easy to perform, shows a rapid reaction and is inexpensive. It may therefore be applied in the routine diagnosis of M. pneumoniae infection in the clinical laboratory.

Adolescent↗

Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M. avium, and M. intracellulare in sputum samples.

Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method in which reagents react under isothermal conditions with high specificity, efficiency, and rapidity. We used LAMP for detection of Mycobacterium tuberculosis complex, Mycobacterium avium, and Mycobacterium intracellulare directly from sputum specimens as well as for detection of culture isolates grown in a liquid medium (MGIT; Nippon Becton Dickinson Co., Ltd., Tokyo, Japan) or on a solid medium (Ogawa's medium). Species-specific primers were designed by targeting the gyrB gene, and their specificities were validated on 24 mycobacterial species and 7 nonmycobacterial species. The whole procedure is quite simple, starting with the mixing of all reagents in a single tube, followed by an isothermal reaction during which the reaction mixture is held at 63 degrees C. The resulting amplicons are visualized by adding SYBR Green I to the reaction tube. The only equipment needed for the amplification reaction is a regular laboratory water bath or heat block that furnishes a constant temperature of 63 degrees C. The assay had a detection limit of 5 to 50 copies of purified DNA with a 60-min incubation time. The reaction time could be shortened to 35 min for the species identification of M. tuberculosis complex, M. avium, and M. intracellulare from a solid-medium culture. Residual DNA lysates prepared for the Amplicor assay (Roche Diagnostics GmbH) from 66 sputum specimens were tested in the LAMP assay. Although the sample size used for the latter assay was small, 2.75 micro l of the DNA lysates, it showed a performance comparable with that of the Amplicor assay, which required 50 micro l of the lysates. This LAMP-based assay is simple, rapid, and sensitive; a result is available in 35 min for a solid-medium culture and in 60 min for a liquid-medium culture or for a sputum specimen that contains a corresponding amount of DNA available for testing.

Animals↗

[Development and evaluation of novel loop-mediated isothermal amplification for rapid detection of bla(IMP-1) and bla(VIM-2) genes].

Loop-mediated isothermal amplification (LAMP) amplifies a target gene with high specificity and rapidity under isothermal conditions. LAMP assays were developed for the rapid detection of metallo-beta-lactamase (MBL) genes such as bla(IMP-1)) and bla(VIM-2). We initially designed specific primers to detect MBL genes for LAMP assays and evaluated the specificity and sensitivity of these assays. LAMP assays amplified MBL genes under a constant temperature of 63 degrees C within 1 hour, and were compared to PCR in MBL-producing strains. The results of MBL genes typing by LAMP assays agree completely with PCR results. The lower detection limits of bla(IMP-1)- and bla(VIM-2)-LAMP assays using real-time turbidimeters were 30cfu/test and 3cfu/test. After amplification, products were directly observed by the naked eye with a fluorescent detection reagent. In conclusion, LAMP assays are convenient, rapid, and fully feasible for detecting MBL genes in ordinary clinical microbiology laboratories without special apparatus.

Gene Amplification↗

Rapid detection of varicella-zoster virus infection by a loop-mediated isothermal amplification method.

The reliability of varicella-zoster virus (VZV) loop-mediated isothermal amplification (LAMP) was evaluated for rapid diagnosis of viral infection. VZV-specific primers only amplified VZV DNA; no LAMP products were observed in reactions performed with other viral DNA templates. The specificity of this method was confirmed by two independent determinations, agarose gel electrophoresis and a turbidity assay. The sensitivity of VZV LAMP, determined by agarose gel electrophoresis, were 500 copies/tube. Detection using the turbidity assay, however, gave a sensitivity of 1,000 copies/tube. After these initial validation studies, reliability of VZV LAMP was evaluated for the detection of viral DNA in clinical specimens. Thirty-two swab samples collected from patients with vesicular skin eruptions were tested for VZV DNA. VZV was confirmed in sample numbers 10-32 by VZV real-time PCR, a previously established technique. VZV LAMP products were detected using turbidity from samples 13 to 32 (sensitivity; 87.0%, specificity; 100%, positive predictive value; 100%, negative predictive value; 75%). Although low levels of VZV DNA could be detected in the three samples exhibiting divergent results (samples numbers 10-12), no VZV LAMP product was detected in these samples, indicating a higher detection limit for this assay. Requirement of a DNA extraction step in the VZV LAMP method was examined in next experiment. The turbidity assay detected a VZV LAMP product in all of the 20 positive swab samples (samples numbers 13-32), regardless of DNA extraction.

Chickenpox↗

Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation.

The loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method that uses only one type of enzyme. One of the characteristics of the LAMP method is its ability to synthesize extremely large amount of DNA. Accordingly, a large amount of by-product, pyrophosphate ion, is produced, yielding white precipitate of magnesium pyrophosphate in the reaction mixture. Judging the presence or absence of this white precipitate allows easy distinction of whether nucleic acid was amplified by the LAMP method. Since an increase in the turbidity of the reaction mixture according to the production of precipitate correlates with the amount of DNA synthesized, real-time monitoring of the LAMP reaction was achieved by real-time measurement of turbidity.

Base Sequence↗

Rapid sex chromosomal chimerism analysis in heterosexual twin female calves by Loop-mediated Isothermal Amplification.

We attempted to apply an embryo sexing kit with Loop-mediated Isothermal Amplification (LAMP) to sex chromosomal chimerism analysis in heterosexual twin female calves. Peripheral blood was used for the amplification of male-specific DNA, derived from XY leukocytes. When blood samples were diluted 1:1000 in LAMP reaction mixture, hemoglobin or blood coagulation did not influence the turbidity measurement of the reaction mixture for detection of amplified DNA. This procedure detected the existence of XY leukocytes of 0.01% in female blood. Furthermore, all heterosexual twin female calves, bearing sex chromosomal chimerism based on karyotyping and PCR, showed male-specific DNA from peripheral blood by LAMP. These results indicated that the embryo sexing kit with LAMP was available for sensitive detection of sex chromosomal chimerism. This procedure made it possible to detect easily Y-chromosome specific DNA in a short interval compared with PCR, and was convenient for field application of freemartin diagnosis.

Animals↗

Development of the loop-mediated isothermal amplification method for rapid detection of cytomegalovirus DNA.

Cytomegalovirus (CMV) loop-mediated isothermal amplification (LAMP) was performed on DNA extracted from CMV (AD-169)-, herpes simplex virus (HSV) 1 (KOS)-, HSV-2 (186)-, varicella-zoster virus (Oka-vaccine)-, human herpesvirus (HHV)-6 A (U1102)-, HHV-6 B (Z29)-, and HHV-7 (RK)-infected cells. Although amplified CMV demonstrated typical ladder patterns, no LAMP product was detected in reactions performed with other viral DNAs. The sensitivity of the CMV LAMP was 500 copies/tube, as determined by either agarose gel electrophoresis or turbidity assay. To determine whether CMV LAMP could be used for quantitative analysis of viral DNA, threshold times, defined as the time (in seconds) to reach the threshold level (0.1), were measured by amplification of serial dilutions of the plasmid DNA. The standard curve exhibited a correlation coefficient of 0.944, a slope of -208.1, and a y-intercept of 3261.4. Following these initial validation experiments, we analyzed 180 samples collected serially from 20 pediatric hematopoietic stem cell transplant recipients. Detection of CMV DNA in whole blood (WB) was tested by CMV LAMP and real-time polymerase chain reaction (PCR). When >500 copies/tube (>5000 copies/200 microl of WB) was defined as positive for CMV infection, the sensitivity, specificity, positive predictive value, and negative predictive values of the CMV LAMP were 80.0, 98.9, 66.7, and 99.4%, respectively.

Child↗

Rapid detection and typing of influenza A and B by loop-mediated isothermal amplification: comparison with immunochromatography and virus isolation.

A reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay was established for the detection of influenza A virus H1 and H3 subtype strains and influenza B virus strains specifically. The total procedure from RNA extraction to virus typing was completed within 3h. In terms of specificity, the representative AH1, AH3 and B strains were detected only by strain-specific primers respectively. No cross-detection was observed. In terms of sensitivity, virus was detected at a minimum concentration of 10 ffu/ml. Eighty-three nasopharyngeal aspirates obtained from children diagnosed clinically with influenza were tested by the RT-LAMP assay, along with commercially available immunochromatography rapid diagnostic tests and by virus isolation. Virus was isolated from 78 samples (94%) and the subtype was determined by the hemagglutination inhibition test. Although it took at least 3 days, the detection sensitivity was the best of the three methods. With two rapid assays, the detection sensitivity of the RT-LAMP assay (85.5%) was higher than that of immunochromatography tests (75.9%). In addition, the RT-LAMP assay can be used to differentiate emerging influenza virus subtypes by selecting appropriate primer sets.

Animals↗

Rapid detection and quantification of Japanese encephalitis virus by real-time reverse transcription loop-mediated isothermal amplification.

We established a rapid, quantitative real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay targeting the envelope gene of Japanese encephalitis virus. The RT-LAMP enabled us to detect the target product within 1 hr by only reacting reverse transcriptase and Bst DNA polymerase in a single tube at an isothermal temperature. The detection sensitivity of the RT-LAMP for Japanese encephalitis virus was 1 PFU, similar to that of conventional reverse transcription-polymerase chain reaction (RT-PCR). Flaviviruses of the Japanese encephalitis virus group, such as Dengue virus and West Nile virus, could not be detected. This confirmed the specificity of the RT-LAMP assay for Japanese encephalitis virus. A standard curve was constructed by plotting viral titer against the time for virus detection by the RT-LAMP, validating the quantitative accuracy of the assay. In addition, the amount of virus estimated by RT-LAMP was strongly correlated (r = 0.902) with that determined by plaque assay, a conventional method for virus quantification. These results indicate that the RT-LAMP assay established in this study is specific for Japanese encephalitis virus, and allows more rapid detection and quantification of the virus.

Animals↗

Sensitive and rapid detection of edwardsiellosis in fish by a loop-mediated isothermal amplification method.

Here we report a rapid and sensitive method (using loop-mediated isothermal amplification [LAMP]) for the diagnosis of edwardsiellosis, a fish disease caused by Edwardsiella tarda, in Japanese flounder. A set of four primers was designed, and conditions for the detection were optimized for the detection of E. tarda in 45 min at 65 degrees C. No amplification of the target hemolysin gene was detected in other related bacteria. When the LAMP primers were used, detection of edwardsiellosis in infected Japanese flounder kidney, and spleen and seawater cultures was possible. We have developed a rapid and sensitive diagnostic protocol for edwardsiellosis detection in fish. This is the first report of the application of LAMP for the diagnosis of a fish pathogen.

Animals↗

Rapid diagnosis of herpes simplex virus infection by a loop-mediated isothermal amplification method.

Primers for herpes simplex virus type 1 (HSV 1)-specific loop-mediated isothermal amplification (LAMP) method amplified HSV-1 DNA, while HSV-2-specific primers amplified only HSV-2 DNA; no LAMP products were produced by reactions performed with other viral DNAs. The sensitivities of the HSV-1- and HSV-2-specific LAMP methods, determined by agarose gel electrophoresis, reached 500 and 1,000 copies/tube, respectively. The turbidity assay, however, determined the sensitivity of the HSV-1- and HSV-2-specific LAMP methods to be 1,000 and 10,000 copies/tube, respectively. After initial validation studies, 18 swab samples (in sterilized water) collected from patients with either gingivostomatitis or vesicular skin eruptions were examined. HSV-1 LAMP products were detected by agarose gel electrophoresis in the 10 samples that also demonstrated viral DNA detection by real-time PCR. Nine of these 10 samples exhibited HSV-1 LAMP products by turbidity assay. Furthermore, both the agarose gel electrophoresis and the turbidity assay directly detected HSV-1 LAMP products in 9 of the 10 swab samples collected in sterilized water. Next, we examined the reliability of HSV type-specific LAMP for the detection of viral DNA in clinical specimens (culture medium) collected from genital lesions. HSV-2 was isolated from all of the samples and visualized by either agarose gel electrophoresis or turbidity assay.

DNA, Viral↗