PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Lasers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

[Diagnostic laser in glaucoma: scanning laser polarimetry (GDx VCC) and confocal scanning laser tomography (HRT)].

Automated structural measurements of retinal nerve fibers and optic nerve head are possible with new lasers providing objective and reproductible data for analysis. Scanning laser polarimetry (GDx VCC), based on retardation of polarized light, assesses peripapillary nerve fiber layer thickness. Confocal scanning laser tomography yields precise topographic maps of the optic disc and peripapillary retina. The advantages, applications for glaucoma detection, both in a screening setting as well as for monitoring progression, limitations and pitfalls need to be well known and results should be analyzed with clinical data.

Disease Progression↗

[Laser therapy of diabetic maculopathy. A comparative study of the argon green laser and dye red laser].

One hundred eyes with (pre)-proliferative diabetic retinopathy underwent central laser treatment for macular involvement. Fifty eyes were treated with the dye red 630 nm, the other 50 with the argon green 514 nm laser. Eighty of the eyes had previously undergone panretinal photocoagulation; in the other 20 this was performed 1.5-3 months after treating the macula because the central retinal changes were predominant. In accordance with the clinical angiographic classification of diabetic maculopathy, into an exudative, an edematous, and an ischemic type, three photocoagulation techniques were employed as appropriate, i.e., focal coagulation, (modified) grid coagulation, and extensive centripetal panretinal coagulation. Neither postoperative visual acuity, nor the fluorescein angiogram, nor fundus color photography revealed any significant difference in the results obtained with the two laser wavelengths.

Diabetic Retinopathy↗

The Glaucoma Laser Trial (GLT). 2. Results of argon laser trabeculoplasty versus topical medicines. The Glaucoma Laser Trial Research Group.

The Glaucoma Laser Trial, a multicenter, randomized clinical trial involving 271 patients, was designed to assess the efficacy and safety of argon laser trabeculoplasty (ALT) as an alternative treatment with topical medication for controlling intraocular pressure (IOP) in patients with newly diagnosed, previously, untreated primary open-angle glaucoma (POAG). Each patient had one eye randomly assigned to ALT (the laser first [LF] eye) and the other eye assigned to timolol maleate 0.5% (the medication first [MF] eye). Medication was initiated or changed for either eye according to the same stepped regimen if the IOP was not controlled. Throughout the 2-year follow-up, LF eyes had lower mean IOPs than MF eyes (1-2 mmHg), and fewer LF eyes than MF eyes required simultaneous prescription of two or more medications to control IOP (P less than 0.001). After 2 years of follow-up, 44% of LF eyes were controlled by ALT, 70% were controlled by ALT or ALT and timolol, and 89% were controlled within the stepped medication regimen. After 2 years, 30% of MF eyes remained controlled by timolol, and 66% were controlled within the stepped regimen. There were no major differences between the two treatment approaches with respect to changes in visual acuity or visual field over the 2 years of follow-up.

Adult↗

[Laser trabeculotomy and laser iridectomy. 3 Years' experience with the Glaucoma Research Laser (Britt) (author's transl)].

This report presents a 3-year study of treatment of the anterior portion of the eye with the Glaucom Research Laser, Model 152, made by Britt Corp. Los Angeles. This study deals specifically with laser trabeculotomy and iridectomy. In this period of time 176 eyes were treated with trabeculotomy and 60 with iridectomy. All types of glaucoma were represented. The technique and the results are demonstrated. This pulsed Argon laser permits surgery with a high rate of success without any serious complications.

Anesthesia↗

[Treatment of inflammatory pyodestructive processes of the oral cavity, maxillofacial area, and neck by laser and magnetic-laser exposure of the carotid sinus using the Optodan laser apparatus].

This paper presents the priority original methods (patent No. 2101046, Russia) for the treatment of inflammatory pyodestructive processes in the oral cavity, maxillofacial area, and neck (odontogenic abscesses and phlegmons including those complicated by mediastinitis and sepsis), sinusitis, carbuncles and furuncles of face and neck skin, parotitis, sialadenitis, adenophlegmons, lymphadenitis, periotitis, alveolitis, arthritis, arthrosis of the temporomandibular joint, odontogenic and traumatic osteomyelitis, infected purulent traumas (including gunshot ones), fractures of the jaws, etc. making use of Optodan laser (patent No. 2014107, Russia) for laser and magnetic-laser therapy.

Carotid Sinus↗

Lactate dehydrogenase in laser incisions: a comparative analysis of skin wounds made with steel scalpel, electrocautery, superpulse--continuous wave mode carbon-dioxide lasers, and contact Nd:YAG laser.

A histochemical method for demonstrating lactate dehydrogenase activity was used in addition to standard Van Gieson stain to study early alterations near wounds made in pig skin by steel scalpel, electrocautery, two modes of CO2 laser (the rapid super-pulse mode and the continuous wave mode), and contact Nd:YAG laser. The enzyme-free zone near the wounds made using the thermal knives appeared to be twice as wide as the necrotic zone observed with Van Gieson stain. In polarized light, the enzyme-free area showed two zones of equal width with respect to birefringence of collagen fibers. The zone lacking birefringence correlated well with that observed with Van Gieson stain. The birefringent zone represented functionally damaged tissue with more or less normal structures by light microscopy. The damage to adjacent tissue caused with the thermal knives seems to be considerably larger than has usually been reported.

Animals↗

[Digital X-ray mammography: comparison of the image quality achievable with a wet laser imager, a dry infrared laser imager and a dry laser imager using direct thermography].

PURPOSE: To compare the image quality of digital X-ray mammographies obtained with wet imagers with that of standard dry imaging technology. MATERIAL AND METHODS: Beginning 03/08/2003, 200 X-ray mammographies with a digital fullfield mammography system (Lorad Selenia, Lorad/Hologic) were prospectively and consecutively documented with a wet laser imager (Scopix LR 5200, Agfa), a dry infrared laser imager (DryView 8610, Kodak) and a dry imager using the principle of direct thermography (Drystar 4500M, Agfa, N = 166). One X-ray exposure was systematically chosen from each examination and was presented in an anonymous and randomized form to three radiologists who evaluated the films using a structured questionnaire. RESULTS: The visualization of normal anatomic structures was considered being good to excellent for all imagers with the mean assessments 1.0 - 2.4 for the Drystar 4500M, 1.0 - 2.1 for the DryView 8610 and 1.1 - 2.0 for the Scopix LR 5200. The mean assessments were 0.1 - 0.6 points lower in dense than in normal parenchyma, thus, the parenchymal density is the predominant factor for image quality. CONCLUSION: In view of the comparable image quality obtained with the different imagers used in the study, individual decisions to purchase a specific imager will be based on economics rather than on diagnostic points of view.

Computer Peripherals↗

Laser surgery in gynecological oncology. Part I: Experimental results. Relapse and metastatic behaviour of the Lewis lung carcinoma subsequent to CO2 laser surgery of the primary tumor. An experimental model to compare the effectiveness of various CO2 laser application techniques.

The influence of various CO2 laser surgical techniques on tumor behaviour was examined in an experimental model on C56BL/6 mice (n = 106) with Lewis Lung carcinomas and compared with that of scalpel excised tumors. Comparisons were made between the healing procedure, the local recurrence rate, metastatic behaviour and the survival rate (n = 86) of mice after laser surgical excision of tumors, using the superpulsed and continuous wave techniques, with and without additional vaporisation of the wound, as well as after general vaporisation only.

Animals↗

Chemically-assisted fragmentation combined with multi-dimensional liquid chromatography and matrix-assisted laser desorption/ionization post source decay, matrix-assisted laser desorption/ionization tandem time-of flight or matrix-assisted laser desorption/ionization tandem mass spectrometry for improved sequencing of tryptic peptides.

Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.

Amino Acid Sequence↗

In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse nd:yag laser and the holmium:yag laser.

PURPOSE: The frequency doubled, double pulse Nd:YAG (FREDDY) laser (World of Medicine, Berlin, Germany) functions through the generation of a plasma bubble. Upon bubble collapse a mechanical shock wave is generated, causing stone fragmentation. This mechanism of action is in contrast to the holmium laser, which cause stone destruction by vaporization. Observed clinical stone retropulsion and fragmentation with the FREDDY and holmium lasers has prompted a series of in vitro experiments designed to compare laser induced retropulsion and fragmentation with those of a holmium laser and pneumatic lithotrite. MATERIALS AND METHODS: For retropulsion a hands-off underwater laboratory setup, including a horizontally oriented silicone tube 1.3 cm in diameter and a holder to keep the stone phantom in contact with the quartz laser fiber or pneumatic probe, was used. Previously weighed, cylindrical Bego stone phantoms (Bego USA, Smithfield, Rhode Island) were placed in the apparatus. Stone fragmentation was performed with the FREDDY or holmium laser, or the pneumatic lithotripter. The FREDDY and holmium lasers were tested at similar pulse energy and frequency settings. As a standard for comparison, a pneumatic lithotrite was tested with a semirigid probe and single pulse settings of 100, 200 and 300 kPa. Stone phantoms underwent 30 shocks per setting. Mean net retropulsion, defined as the final resting point of the stone, as determined by direct measurement, was recorded for each setting. For fragmentation plaster of Paris stone phantoms of known weights were used to compare the fragmentation ability of each laser. Stones phantoms were placed in a hands-off underwater setup, consisting of an inverted silicon syringe and holder immersed in tap water. The laser fiber (365 microm for the holmium and 280 microm for the FREDDY) was placed through the tip of the syringe in contact with the stone phantom. A total of 24 stones were divided into 4 groups of 6 per group. Two groups were fragmented with the FREDDY laser at 300 and 400 J total energy. The other 2 groups were fragmented using the holmium laser at 300 and 480 J total energy. Fragmentation efficiency was determined as percent weight loss. RESULTS: For retropulsion at 160 mJ the FREDDY laser caused stone retropulsion to a mean distance of 7.6, 8.1 and 6.8 cm at settings of 5, 10 and 15 Hz, respectively. At 0.8 J the holmium laser retropulsed the stone to a mean distance of 3.3 and 4.9 cm at settings of 5 and 10 Hz, respectively. The pneumatic device caused stone retropulsion a mean distance of 8.5, 9.9 and 13.8 cm at pressure settings of 100, 200 and 300 kPa, respectively. The FREDDY laser generally caused less retropulsion than the pneumatic device, although this difference was only significant at the highest pneumatic lithoclast setting (p <0.05). At clinically relevant settings the FREDDY laser caused significantly more retropulsion than the holmium laser (p <0.05). For fragmentation at total energy settings of 300 and 400 J the FREDDY laser resulted in 44.9% and 86.8% weight loss, respectively (p <0.05). At settings of 300 and 480 J the holmium:YAG laser resulted in 3.3% and 7.1% weight loss, respectively (p <0.05). CONCLUSIONS: At lower frequency settings stone retropulsion was significantly greater with the FREDDY laser compared with the holmium laser. However, retropulsion was significantly less than that caused by the pneumatic lithotripter at all settings. Therefore, we recommend the use of an occlusive device, such as the Stone Cone (Boston Scientific, Natick, Massachusetts) proximal to the calculus during intracorporeal ureteral lithotripsy and in the ureteropelvic junction during percutaneous laser nephrostolithotomy. In vitro stone fragmentation was significantly greater with the FREDDY laser than with the holmium:YAG laser, suggesting that the FREDDY may offer a low cost alternative to the holmium:YAG laser lithotrite in select patients.

Equipment Design↗

Myocardium tissue ablation with high-peak-power nanosecond 1,064- and 532-nm pulsed lasers: influence of laser-induced plasma.

BACKGROUND AND OBJECTIVES: We investigated the mechanism and characteristics of porcine myocardium tissue ablation in vitro with nanosecond 1,064- and 532-nm pulsed lasers at laser intensities up to approximately 5.0 GW/cm(2). Particular attention was paid to study the influence of the laser-induced plasma on the ablation characteristics. The applicability of these two lasers to transmyocardial laser revascularization (TMLR) was discussed. STUDY DESIGN/MATERIALS AND METHODS: Porcine myocardium tissue samples were irradiated with 1,064- and 532-nm, Q-switched Nd:YAG laser pulses, and the ablation depths were measured. The temporal profiles of the laser-induced optical emissions were measured with a biplanar phototube. For the ablated tissue samples, histological analysis was performed with an optical microscope and a polarization microscope. RESULTS: The ablation efficiency at 1,064 nm was higher than that at 532 nm. The ablation threshold at 1,064 nm (approximately 0.8 GW/cm(2)) was lower than that at 532 nm (approximately 1.6 GW/cm(2)), in spite of the lower absorption coefficient being expected at 1,064 nm. For the 1,064-nm laser-ablated tissues, thermal damage was very limited, while damage presumably caused by the mechanical effect was observed in most of the cases. For the 1,064-nm laser ablation, the ablation threshold was equal to the threshold of the laser-induced optical emission (approximately 0.8 GW/cm(2)), while for the 532-nm laser ablation, the optical emission threshold ( approximately 2.4 GW/cm(2)) was higher than the ablation threshold. CONCLUSIONS: We considered that for the 1,064-nm laser ablation, the tissue removal was achieved through a photodisruption process at laser intensities of > approximately 0.8 GW/cm(2). At laser intensities of > 3.0 GW/cm(2), however, the ablation efficiency decreased; this can be attributed to the absorption of incoming laser pulses by the plasma. For the 532-nm laser ablation, the tissue removal was achieved through a photothermal process at laser intensities of > approximately 1.6 GW/cm(2). At laser intensities of > 2.4 GW/cm(2), a photodisruption process may also contribute to the tissue removal, in addition to a photothermal process. With regard to the ablation rates, the 1,064-nm laser was more suitable for TMLR than the 532-nm laser. We concluded that the 1,064-nm Q-switched Nd:YAG laser would be a potential candidate for a laser source for TMLR because of possible fiber-based beam delivery, its compact structure, cost effectiveness, and easy maintenance. Animal trials, however, have to be carried out to evaluate the influence of the tissue damage.

Animals↗

[Optical properties of human normal bladder tissue at five different wavelengths of laser and their linearly polarized laser irradiation in vitro].

A double-integrating-spheres system, the basic principle of measuring technology of radiation, and an optical model of biological tissues were used for the study. Optical properties of human normal bladder tissue at 476.5, 488, 496.5, 514.5 and 532 nm of laser and their linearly polarized laser irradiation were studied. The results of measurement showed that total attenuation coefficient and scattering coefficient of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation increased with decreasing wavelengths. And these was an obvious distinction between the results at these wavelengths of laser and their linearly polarized laser irradiation. Absorption coefficient of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation was tardily increased with decreasing wavelengths. But there were a number of gurgitations. And these were independent of the wavelengths of laser or their linearly polarized laser irradiation. Mean cosine of scattering of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation also increased with decreasing wavelengths. And these was an obvious distinction with these wavelengths of laser and their linearly polarized laser irradiation. But penetration depth of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation also increased with increasing wavelengths. But there were a number of gurgitations. Refractive index of human normal bladder tissue at these wavelengths of laser ranged from 1.37 to 1.44. Absorption coefficient, scattering coefficient, total attenuation coefficient, and effective attenuation coefficients of human normal bladder tissue in Kubelka-Munk two-flux model at the same wavelength of laser and the linearly polarized laser irradiation do not exhibit prominent distinction (P > 0.05). Some absorption coefficient, scattering coefficient, total attenuation coefficient, and effective attenuation coefficient of human normal bladder tissue in Kubelka-Munk two-flux model at different wavelengths of laser and their linearly polarized laser irradiation exhibit obvious distinction.

Humans↗

Diode laser-pumped, frequency-doubled neodymium: YAG laser peripheral iridotomy.

BACKGROUND AND OBJECTIVE: The solid-state, continuous-wave, frequency-doubled neodymium: yttrrium-aluminum-garnet (Nd:YAG) laser pumped by a diode laser has several advantages, including air cooling, higher electrical to optical efficiency ratios, portability, and the use of standard 110-V AC electrical service. The authors wanted to evaluate the use of the frequency-doubled Nd:YAG laser for peripheral iridotomy and to compare the tissue interactions of this laser with those of the argon laser. MATERIAL AND METHODS: The authors developed a diode laser-pumped, solid-state, and portable frequency-doubled Nd:YAG laser with a wavelength of 532 nm. The effects of peripheral iridotomy with the frequency-doubled Nd:YAG laser and the argon laser were evaluated in pig eyes in vitro and in rabbit eyes in vivo. Specimens were prepared for light microscopy and scanning electron microscopy. RESULTS: The frequency-doubled Nd:YAG laser successfully created patent iridotomies in all animal eyes treated. The following parameters were used to create penetrating burns: duration of 0.1 second, spot size of 100 microns, and power of 500 mW. In rabbit eyes, the mean number of pulses (P = .16) and the total energy required (P = .21) for iridotomy were not significantly different for the argon laser compared with the frequency-doubled Nd:YAG laser. Gross and histologic evaluation showed similar thermal effects in iris tissues for both the frequency-doubled Nd:YAG laser and the argon laser. The mean zone of thermal damage was 178 +/- 19 microns for the frequency-doubled Nd:YAG laser and 163 +/- 24 microns for the argon laser (P = .14). Scanning electron microscopy showed less disruption of the surface of the lesion for the frequency-doubled Nd:YAG laser compared with the argon laser. CONCLUSIONS: Successful peripheral iridotomy can be performed with the frequency-doubled Nd:YAG laser. Coagulative effects with the frequency-doubled Nd:YAG were similar to those with the argon laser, and the thermal damage zones were comparable in size.

Animals↗

Characteristics of shock waves induced by pulsed lasers and their effects on arterial tissue: comparison of excimer, pulse dye, and holmium YAG lasers.

Shock waves were investigated using an excimer laser at 308 nm with 18.9 mjoules/pulse, a pulsed dye laser at 480 nm with 100 mjoules/pulse, and a holmium YAG (yttrium-aluminum-garnet) laser at 2.1 microns with 420 mjoules/pulse. At a distance from the target tissue, excimer lasing resulted in no shock waves in saline, while the other lasers produced smaller shock waves than those recorded when the laser was in contact with tissue (0.22 versus 2.0 mm Hg with the pulsed dye laser, 0 versus 0.23 mm Hg with the excimer laser, and 0.44 versus 6.9 mm Hg with the holmium YAG laser; p less than 0.001, respectively). In blood, excimer laser irradiation at a distance from the tissue produced shock waves as great as those produced when the laser was in contact with the tissue (0.19 versus 0.24 mm Hg with the excimer laser, 1.8 versus 3.0 mm Hg with the pulsed dye laser, and 3.1 versus 5.9 mm Hg with the holmium YAG laser; p less than 0.001 with the pulsed dye and holmium YAG lasers, respectively). When lasing was done at 60 mjoules/mm2, the pulsed dye and excimer lasers produced similar shock waves when the lasers were in contact with tissue; however, the holmium YAG laser did not produce shock waves. Thus pulsed lasers can produce shock waves of different characteristics according to the laser source.

Analysis of Variance↗

The theoretical vs. measured laser resection for laser in situ keratomileusis.

PURPOSE: To measure the excimer laser resection during and after laser in situ keratomileusis (LASIK) and to determine the rate of stromal ablation and factors predicting its measurement. METHODS: A retrospective, comparative, interventional case study of 6010 eyes undergoing LASIK surgery was performed. In vivo ultrasonic pachymetry was performed as a measure of the laser resection (1'MLR). The theoretical laser resection generated by one of three separate excimer lasers (Summit Apex Plus, Alcon LadarVision, VISX) was recorded. The change in central comeal thickness measured at enhancement surgery (2'MLR) and the change in the residual stromal thickness prior to the laser ablation at the primary and enhancement procedure (3'MLR) were recorded as separate measures of the laser resection. Paired sample t test and regression analysis was performed to determine the relationships and to develop a model predictive of laser resection for each laser. RESULTS: For all lasers, 1'MLR produced the highest estimate compared to 3'MLR. Laser-induced stromal desiccation, microkeratome effects, and change in measured flap thickness were the most likely causes for the differences. Laser resection was overestimated in the Alcon theoretical laser resection group, but underestimated in the Summit and VISX groups. The difference between 2'MLR and 3'MLR was due to epithelial hyperplasia, which measured 8.3, 17.8, and 10.8 microm in the Alcon, Summit, and VISX enhancement groups, respectively. Stromal ablation rates were 11.79, 8.26, and 12.71 microm per spherical equivalent diopter laser setting for the Alcon, Summit, and VISX lasers, respectively, when measured with 3'MLR. Multiple pre- and perioperative factors were associated with laser resection. CONCLUSIONS: To accurately predict residual corneal thickness, the expected laser resection for an attempted refractive change must be known. As the laser resection can be laser-specific, the surgeon needs to establish the mean and range of tissue removal for a given attempted correction.

Adult↗

Choice of lasers for laser angioplasty.

Thrombi in test-tube, intraarterial thrombi and pig aorta wall were in vitro irradiated with continuous CO2 laser, short pulsal and ultrashort pulsal YAG laser (with pulse-width of 10 ns and 40 ps, respectively) and their double frequency laser and excimer laser with a wave-length of 308 nm and pulse-width of 20 ns. Their effect of vaporizing and ablating (photodecomposing) thrombi and their thermal injuring effect on adjacent tissues were compared and assessed in order to select optimal laser with little thermal injuring and more rapid vaporizing or ablating thrombi effect for laser angioplasty. The experimental results showed that excimer laser, ultrashort pulsal YAG laser and its double frequency laser, and double frequency laser of short pulsal YAG laser, with laser beam and blood vessel kept in a coaxial position, can effectively vaporize or ablate thrombi without thermal injury to vessel wall. So they may be used for laser angioplasty. Of them, especially, excimer laser and double frequency laser of ultrashort pulsal YAG laser have short wave-length and high peak power, and more effectively ablate thrombi than others, so they proved to be optimal lasers for laser angioplasty.

Angioplasty, Balloon↗

[Comparative research on attenuation characteristics of human bladder cancer tissue at different wavelengths of laser and their linearly polarized laser in vitro].

In this paper, a double-integrating-spheres system, the basic principle of measuring technology of ray radiation, and the optical model of biological tissues were used for the study. Attenuation characteristics of human bladder cancer tissue at 467.5, 488, 496.5, 514.5 and 532 nm laser and their linearly polarized laser irradiation were studied. The results of measurement showed that the attenuation characteristics of human bladder cancer tissue in Kubelka-Munk two-flux model were different at different wavelengths of laser irradiation in the range of five different laser wavelengths. There were significant differences in the total attenuation or effective attenuation coefficients of human bladder cancer tissue at 476.5, 496.5, and 532 nm wavelengths of laser and their linearly polarized laser irradiation (P>0.05), and there were no significant differences at 488 and 514.5 nm wavelengths of laser and their linearly polarized laser irradiation in two-flux model (P>0.05). The total attenuation and effective attenuation coefficients of human bladder cancer tissue at 532 nm laser and its linearly polarized laser irradiation were obviously bigger than those at other four different wavelengths of laser and their linearly polarized laser irradiation in two-flux model. The total attenuation and effective attenuation coefficients of human bladder cancer tissue at five different wavelengths of laser and their linearly polarized laser irradiation increased with the decrease of these wavelengths, there were significant differences in those at 476.5, 496.5 and 514.5 nm wavelengths of laser and their linearly polarized laser irradiation (P<0.05), and there were no significant differences in those at 488 and 532 nm wavelengths of laser and their linearly polarized laser irradiation in light transport theory (P>0.05).

Cell Line↗

Prophylactic laser treatment hastens choroidal neovascularization in unilateral age-related maculopathy: final results of the drusen laser study.

PURPOSE: The Drusen Laser Study evaluated macular laser to prevent choroidal neovascularization (CNV) and vision loss in high-risk age-related maculopathy (ARM). DESIGN: Prospective, interventional, randomized, controlled clinical trial in five hospital centers. METHODS: Patients in the unilateral group had neovascular ARM and drusen in the study eye. Study eyes were randomized to laser-treated or no-laser groups. For patients in the bilateral drusen group, eyes were randomized to right eye, laser or no laser; and left eye, alternative. Laser treatment comprised 12 argon spots. Outcome was best-corrected visual acuity and CNV signs, which were monitored for 3 years. RESULTS: In the unilateral group, vision loss occurred in 21 (28.8%) of 73 patients in laser vs 13 (19.7%) of 66 no-laser patients (P=.214). Incidence of CNV was 27 (29.7%) of 91 in laser vs 15 (17.65%) of 85 no-laser patients (P=.061). CNV onset was approximately 6 months earlier in laser-treated compared with no-laser patients (P=.05). In the bilateral group, vision loss occurred in six (8.3%) of 72 laser-treated vs 10 (13.9%) of 72 fellow eyes (P=.3877). CNV incidence was 12 (11.6%) of 103 in laser-treated vs seven (6.8%) of 103 fellow eyes (P=.225). There was no difference in onset of CNV. CONCLUSIONS: Results do not support prophylactic laser of the fellow eye of patients with neovascular ARM. Its role in patients with bilateral drusen remains unclear.

Aged↗