PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Multiplex”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Multiplexed analysis of biomarkers related to obesity and the metabolic syndrome in human plasma, using the Luminex-100 system.

BACKGROUND: The complex pathology of disease has sparked the development of novel protein expression profiling techniques that require validation in clinical settings. This study focuses on multiplexed analyses of adipocytokines and biomarkers linked to the metabolic syndrome, diabetes, and cardiovascular disease. METHODS: Multiplexed immunoassays using fluorescent microspheres and the Luminex-100 system were performed on plasma from 80 obese patients (40 with the metabolic syndrome) before and after 6-8 weeks of diet-induced weight loss. Leptin, insulin, C-peptide, monocyte chemoattractant protein-1 (MCP-1), eotaxin, interleukin-8 (IL-8), tumor necrosis factor-alpha (TNF-alpha), and IL-6 concentrations measured with multiplex panels from 3 different manufacturers were compared with results from commercial ELISAs. Detection limits and between- and within-run imprecision were determined for each analyte. Bland-Altman analysis was used to determine agreement between multiplexed immunoassays and ELISAs. RESULTS: Correlation between the Luminex multiplexed assays and ELISAs was good for leptin (Linco), insulin (Linco), MCP-1 (Biosource and Upstate), and eotaxin (Biosource) with correlation coefficients of 0.711-0.895; fair for eotaxin (Upstate) and C-peptide (Linco) with correlation coefficients of 0.496-0.582; and poor for TNF-alpha, IL-8, and IL-6 (Linco, Biosource, Upstate, and R&D) with correlation coefficients of -0.107 to 0.318. Within- and between-run imprecision values for the multiplex method were generally <15%. Relative changes in plasma leptin and insulin concentrations after diet-induced weight loss were similar whether assessed by multiplex assay or ELISA. CONCLUSION: Although this technology appears useful in clinical research studies, low assay sensitivity and poor correlations with conventional ELISA methods for some analytes with very low plasma concentrations should be considered when using the Luminex platform in clinical studies.

Adipose Tissue↗

Fragment size difference between multiplex and singleplex PCR products and their practical implications.

By simultaneously amplifying several loci in the same reaction, multiplex PCR has been used in gene mapping and DNA typing with polymorphic short tandem repeat loci. Previous studies have discussed in detail the various parameters and conditions that influence the quantity of individual products generated by multiplex PCR. In practice, when a primer pair fails to amplify in a multiplex PCR for some individuals, singleplex PCR is often employed as a supplement to amplify the primer pair. However, the reliability of this procedure is unknown. In this study, we used six primer pairs from ABI PRISM Linkage Mapping Set version 2 to perform multiplex and singleplex reactions. The fluorescence-labeled amplification products were separated and detected on ABI PRISM 310 Genetic Analyzer. We found that for the marker D1S468, multiplex and singleplex reactions for the majority of individuals yielded reactions of different sizes. Therefore, the potential size difference between multiplex and singleplex reactions needs to be investigated. This investigation is essential to employ multiplex PCR supplemented with singleplex PCR in gene mapping and DNA typing.

DNA↗

Multiplex polymerase chain reaction for diagnosis of viral and chlamydial keratoconjunctivitis.

PURPOSE: To develop a multiplex polymerase chain reaction (PCR) for the detection of adenovirus, herpes simplex virus, and Chlamydia trachomatis in conjunctival swabs. METHODS: Oligonucleotide primers for detection of the 3 agents were combined in one reaction and evaluated for optimal performance using control DNAs of adenovirus type 2, herpes simplex virus, and C. trachomatis plasmid. The multiplex PCR was evaluated prospectively against its corresponding uniplex PCRs, virus isolation, Chlamydia Amplicor PCR, and an immunoassay technique (immune dot blot test) in a total of 805 conjunctival swabs from patients with suspected viral and chlamydial keratoconjunctivitis. RESULTS: The multiplex PCR was as sensitive as uniplex PCRs for the detection of the agents in clinical specimens. In the prospective study, 48 of 49 (98%) clinical specimens were positive for adenovirus by the multiplex PCR compared with 26 of 49 (53%) by adenovirus isolation. For herpes simplex virus detection, the multiplex PCR had a sensitivity of 92% (34/37) compared with 94.5% (35/37) by cell culture. The multiplex PCR produced identical results to the Amplicor PCR (21/21; 100%) compared with 71% (15/21) by the immune dot blot test. CONCLUSIONS: With clinical specimens the multiplex PCR was as sensitive as its respective uniplex PCRs but more sensitive than adenovirus isolation and as sensitive as herpes simplex virus isolation or C. trachomatis Amplicor PCR. It has the potential to replace several diagnostic tests with consequent savings in cost. The test also reduces the risk of misdiagnosis by the clinicians.

Adenovirus Infections, Human↗

Mononeuritis multiplex: the yield of evaluations for occult rheumatic diseases.

We identified 35 patients who had electrodiagnostic evidence of mononeuritis multiplex and did not have diabetes or multiple nerve compressions. Their charts were reviewed to determine the etiologies of the mononeuritis multiplex and to determine how often the laboratory examination revealed a rheumatic disease in patients whose initial history and physical examination did not suggest that a rheumatic disease was present. In 11/35 (31%; CI = 17-49) a disorder capable of causing mononeuritis multiplex was diagnosed before the symptoms of mononeuritis multiplex began. Ten had a rheumatic disease; 1 had lymphoma. Nine of the other patients were suspected, on the basis of the history and physical examination, of having new onset of a rheumatic disease. Subsequent laboratory evaluation showed that 5/9 (56%; CI = 21-86) had a rheumatic disease, and 4/9 (44%; CI = 14-79) were unknowns. In 15/35 (43%; CI = 26-61) patients with mononeuritis multiplex, no rheumatic disease was suspected on the basis of the initial history and physical examination. The subsequent laboratory examination revealed an underlying rheumatic disease in 0/15 (0%; CI = 0-18). Mean clinical follow-up of 16 +/- 16 months in the patients with mononeuritis multiplex of unknown cause also failed to identify a rheumatic disease. Overall 19/35 (54%; CI = 37-71) did not have a rheumatic disease or any other known cause. Of the 14 patients with mononeuritis multiplex associated with a rheumatic disease, 5/14 (36%; CI = 13-15) had systemic lupus erythematosus; an additional patient had both lupus and the CREST syndrome.(ABSTRACT TRUNCATED AT 250 WORDS)

Biopsy↗

Validation of a diagnostic multiplex polymerase chain reaction assay for infectious posterior uveitis.

OBJECTIVE: To validate a multiplex polymerase chain reaction (PCR) assay capable of simultaneously screening vitreous biopsy specimens for a panel of common pathogens in posterior uveitis. METHODS: A multiplex PCR assay using novel primer sets for cytomegalovirus (CMV), herpes simplex virus (HSV), varicella zoster virus (VZV), and Toxoplasma gondii was developed. The sensitivity of the assay was determined for purified pathogen DNA. Twenty-one vitreous specimens from patients with posterior uveitis were tested by both multiplex and monoplex PCR. RESULTS: Fewer than 10 genomes of VZV and fewer than 100 genomes of HSV, CMV, and T gondii could be detected using the new primer sets. When used in multiplex, the assay lost less than 1 log of sensitivity. Monoplex PCR detected pathogen DNA in 18 of 21 patient samples; multiplex PCR detected pathogen DNA in 15 of the 18 samples positive by monoplex PCR. None of 10 negative control samples were positive for pathogen DNA. CONCLUSIONS: Multiplex PCR has adequate sensitivity to simultaneously screen a substantial differential diagnosis for posterior uveitis in a single reaction, without loss of specificity. This assay may reduce the time and cost involved in PCR-based molecular diagnostics of infectious pathogens. CLINICAL RELEVANCE: Mutiplex PCR may allow rapid diagnosis of infectious posterior uveitis.

Animals↗

Fluorescence-intensity multiplexing: simultaneous seven-marker, two-color immunophenotyping using flow cytometry.

BACKGROUND: Conventional immuno-based multiparameter flow cytometric analysis has been limited by the requirement of a dedicated detection channel for each antibody-fluorophore set. To address the need to resolve multiple biological targets simultaneously, flow cytometers with as many as 10-15 detection channels have been developed. In this study, a new Zenon immunolabeling technology is developed that allows for multiple antigen detection per detection channel using a single fluorophore, through a unique method of fluorescence-intensity multiplexing. By varying the Zenon labeling reagent-to-antibody molar ratio, the fluorescence intensity of the antibody-labeled cellular targets can be used as a unique identifier. Although demonstrated in the present study with lymphocyte immunophenotyping, this approach is broadly applicable for any immuno-based multiplexed flow cytomety assay. METHODS: Lymphocyte immunophenotyping of 38 clinical blood specimens using CD3, CD4, CD8, CD16, CD56, CD19, and CD20 antibodies was performed using conventional flow cytometric analysis and fluorescence-intensity multiplexing analysis. Conventional analysis measures a single antibody-fluorophore per photomultiplier tube (PMT). Fluorescence-intensity multiplex analysis simultaneously measures seven markers with two PMTs, using Zenon labeling reagent-antibody complexes in a single tube: CD19, CD4, CD8, and CD16 antibodies labeled with Zenon Alexa Fluor 488 Mouse IgG(1) labeling reagent and CD56, CD3, and CD20 antibodies labeled with Zenon R-Phycoerythrin (R-PE) Mouse IgG(1) or IgG(2b) labeling reagents. RESULTS: The lymphocyte immunophenotyping results from fluorescence-intensity multiplexing using Zenon labeling reagents in a single tube were comparable to results from conventional flow cytometric analysis. CONCLUSIONS: Simultaneous evaluation of multiple antigens using a single fluorophore can be performed using antibodies labeled with varying ratios of a Zenon labeling reagent. Labeling two sets of antibodies with different Zenon labeling reagents can generate characteristic and distinguishable multivariate patterns. Combining multiple antibodies and fluorescent labels with fluorescence intensity multiplexing enables the resolution of more cellular targets than detection-channels, allowing sophisticated multiparameter flow cytometric studies to be performed on less complex 2- or 3-detection-channel flow cytometers. For typical biological samples, approximately 2-4 cellular targets per detection channel can be resolved using this technique.

Antigens, CD19↗

Sensitive and simultaneous analysis of five transgenic maizes using multiplex polymerase chain reaction, capillary gel electrophoresis, and laser-induced fluorescence.

The benefits of using multiplex polymerase chain reaction (PCR) followed by capillary gel electrophoresis with laser-induced fluorescence (CGE-LIF) for the simultaneous detection of five transgenic maizes (Bt11, T25, MON810, GA21, and Bt176) are demonstrated. The method uses a hexaplex PCR protocol to amplify the five mentioned transgenic amplicons plus the zein gene used as reference, followed by a CGE-LIF method to analyze the six DNA fragments. CGE-LIF was demonstrated very useful and informative for optimizing multiplex PCR parameters such as time extension, PCR buffer concentration and primers concentration. The method developed is highly sensitive and allows the simultaneous detection in a single run of percentages of transgenic maize as low as 0.054% of Bt11, 0.057% of T25, 0.036% of MON810, 0.064% of GA21, and 0.018% of Bt176 in flour obtaining signals still far from the detection limit (namely, the signal/noise ratios for the corresponding DNA peaks were 41, 124, 98, 250, 252, and 473, respectively). These percentages are well below the minimum threshold marked by the European Regulation for transgenic food labeling (i.e., 0.5-0.9%). A study on the reproducibility of the multiplex PCR-CGE-LIF procedure was also performed. Thus, values of RSD lower than 0.67 and 6.80% were obtained for migration times and corrected peak areas, respectively, for the same sample and three different days (n = 12). On the other hand, the reproducibility of the whole procedure, including four different multiplex PCR amplifications, was determined to be better than 0.66 and 23.3% for migration times and corrected peak areas, respectively. Agarose gel electrophoresis (AGE) and CGE-LIF were compared in terms of resolution and sensitivity for detecting PCR products, demonstrating that CGE-LIF can solve false positives induced by artifacts from the multiplex PCR reaction that could not be addressed by AGE. Moreover, CGE-LIF provides better resolution and sensitivity. To our knowledge, these results demonstrate for the first time that multiplex PCR-CGE-LIF is a solid alternative to determine multiple genetically modified organisms in maize flours in a single run.

DNA Primers↗

Detection of Plasmodium falciparum and Wuchereria bancrofti infected blood samples using multiplex PCR.

A rapid and sensitive multiplex PCR has been developed for the diagnosis of multiple parasitic infection in human blood. Infection is detected by a single multiplex PCR reaction containing two pairs of oligonucleotide primers whereby each primer is specific for each parasite species. These primer sets amplified 400 and 450-bp fragments for Wuchereria bancrofti and 208-bp fragment for Plasmodium falciparum. The PCR products derived from each parasite species were visualized in ethidium bromide-stained agarose gels, therefore allowing the rapid identification of any, or all, of the two human parasites, if present, in a single amplification reaction. This multiplex PCR was very sensitive with the ability to detect the presence of as little as 10 pg of parasite DNA. The primers used in this multiplex PCR also showed highly specific amplification of each respective parasite DNA without the presence of non-specific and non-target PCR products. This multiplex PCR system was used to analyse 36 human blood samples of Myanmar workers in the endemic area at Tak Province, Thailand. Two samples showed the multiple infection, 27 samples were either infected with W. bancrofti or P. falciparum and seven samples were negative for both methods. The high sensitivity, specificity and rapidity of this multiplex PCR method make it suitable for large-scale epidemiological studies and following of drug treatment.

Adolescent↗

Multiplex PCR design strategy used for the simultaneous amplification of 10 Y chromosome short tandem repeat (STR) loci.

The simultaneous amplification of multiple regions of a DNA template is routinely performed using the polymerase chain reaction (PCR) in a process termed multiplex PCR. A useful strategy involving the design, testing, and optimization of multiplex PCR primer mixtures will be presented. Other multiplex design protocols have focused on the testing and optimization of primers, or the use of chimeric primers. The design of primers, through the close examination of predicted DNA oligomer melting temperatures ( T(m)) and primer-dimer interactions, can reduce the amount of testing and optimization required to obtain a well-balanced set of amplicons. The testing and optimization of the multiplex PCR primer mixture constructed here revolves around varying the primer concentrations rather than testing multiple primer combinations. By solely adjusting primer concentrations, a well-balanced set of amplicons should result if the primers were designed properly. As a model system to illustrate this multiplex design protocol, a 10-loci multiplex (10plex) Y chromosome short tandem repeat (STR) assay is used.

Base Sequence↗

Development of the AmpFISTR SEfiler PCR amplification kit: a new multiplex containing the highly discriminating ACTBP2 (SE33) locus.

The AmpFISTR SEfiler kit co-amplifies 11 short tandem repeat loci including SE33 in a single multiplex. After establishing the optimum in primer titration studies, the primer concentrations of all loci in the multiplex were chosen such that the heterozygote peak height ratios of each of the loci were balanced. The combined primer set was then tested to determine the robustness of the multiplex under various conditions. Different MgCl(2) concentrations were evaluated to establish the optimum concentration for the multiplex. The amplification of the various loci in the multiplex was tested at several annealing temperatures (55-63 degrees C). Additionally, DNA from primates, non-primates and microorganisms were amplified to investigate the specificity of the kit. The stability of the AmpFISTR SEfiler kit was determined by addition of hematin, to simulate inhibition, and the use of degraded DNA. Population studies revealed a probability of identity of 6.47x10(-15) for African Americans and 7.46x10(-14) for US Caucasians. To assess the ability of the multiplex to analyze forensic samples, testing on blood, oral swabs and mixtures was performed. Based on the various studies, it was determined that the AmpFISTR SEfiler PCR amplification kit can be used to successfully analyze a variety of forensic, databasing and paternity samples.

Animals↗

Development of a whole-virus multiplex flow cytometric assay for antibody screening of a specific pathogen-free primate colony.

Our goal was to determine if a multiplex technique using a fluorescent bead-based flow cytometric assay could yield results comparable to traditional enzyme-linked immunosorbent assay (ELISA) in terms of sensitivity, specificity, cross-reactivity, and throughput. We applied both techniques to serologic screening of specific pathogen-free macaques, for type D simian retrovirus, simian T-lymphotropic virus, Cercopithicine herpesvirus 1, and simian immunodeficiency virus, and found a high correlation between the bead-based multiplex assay and ELISA. The multiplex assay demonstrated greater sensitivity with no loss in specificity when compared to the ELISA. A lower false-positive rate with the multiplex assay decreased the number of confirmatory Western blots required. Using the multiplex assay, we were able to screen samples for 4 viruses simultaneously in the time it took to perform a single-virus ELISA, resulting in a faster turnaround time and higher throughput. The multiplexed assay provided greater sensitivity, increased stability, and better performance than ELISA.

Animals↗

New multiplexes for Europe-amendments and clarification of strategic development.

Recently, the ENFSI/EDNAP groups issued advice on the design of the next generation of STR multiplexes in order to encourage standardisation within Europe. As the result of collaborative experimentation within the EDNAP group, we demonstrated that the low molecular weight STRs had substantial benefits to detect degraded samples. We subsequently recommended adoption of three new mini-STR loci to improve the success rate of degraded DNA markers, concurrent with the reduction in size of the existing STR markers in current use. This also improves the discriminating power of the system which is important to improve the power of national DNA databases. Subsequent discussions have occurred with manufacturers and members of the ENFSI/EDNAP groups. Because significant time and investment is required to develop new multiplexes of 13+ STR loci, manufacturers indicated that it would be preferable to adopt a staged approach. Two differing, but parallel strategies have now emerged. The first strategy employs a 13 STR loci multiplex incorporating three mini-STRs into the current multiplex test. The second strategy employs a multiplex of six high molecular weight STRs (in current use), modified to provide smaller amplicons combined with an additional two loci of high discriminating power. Eventually, the two strategies will converge to provide a single multiplex of 15 STR loci. The process will be guided by the ENFSI/EDNAP groups.

DNA Fingerprinting↗

Multiplexed PCR genotyping of HPVs from plantaris verrucae.

BACKGROUND: Plantaris verrucae are a common diagnosis in childhood, consume a significant amount of health-care resources, have many painful treatment options and many recurrences. OBJECTIVES: The objective of this study was to design and test a single site-anchored, multiplexed and expandable PCR assay for common types of cutaneous HPVs. STUDY DESIGN: Common forward and unique reverse primers were selected from the E2 open reading frames of five cutaneous HPV genotypes. These were analyzed for sensitivity and selectivity using pHPV plasmids and several control DNAs in an optimized multiplexed assay. This standardized assay was used to analyze human verruca plantaris tissue for genome type and to evaluate the effect of a commonly used treatment protocol. RESULTS: A sensitive, multiplexed PCR assay for human cutaneous HPV genotypes 1a, 2a and 4 was developed. Specific-unique primers and a consensus anchor primer were selected within the HPV E2 region to produce amplicons varying by greater than 100bp. In analytical sensitivity studies, fewer than 100 genome copies of HPV1a and 2a were detected, and fewer than 1000 copies of HPV4 were detected. The multiplexed assay did not amplify regions of human placenta, calf thymus, CaSki or SiHa DNA and E. coli, pBR322 or non-HPV virus DNAs. In combination with a forensic DNA extraction procedure, the multiplexed HPV assay detected and identified HPV types in 23 of 51 (45%) deep plantaris verrucae. Two patients were found with two different genotypes in single deep plantaris verruca. Detection of the HPV genome was followed as a function of tissue ablation and Mediplast treatment in one patient. In healing tissue, the genome content was reduced but had not totally disappeared. CONCLUSIONS: The multiplexed HPV assay can be used to determine genotype prevalence that may correlate with treatment efficacy.

Genotype↗

Development, validation, and implementation of a multiplex immunoassay for the simultaneous determination of five cytokines in human serum.

Quantification of biomarkers can provide important information about the safety and efficacy of candidate drugs. Unfortunately, limited sample volume and excess costs often limit analysis of multiple biomarkers. We developed, optimized, validated, and implemented a multiplex immunoassay for simultaneous measurement of multiple circulating cytokines: IL-1beta, TNFalpha, IL-6, IL-8, and IL-10. Multiplex immuoassays were performed using the Luminex LabMAP instrument. Capture antibodies for each cytokine were covalently bound to distinct microsphere subsets distinguished by differing dye ratios. The concentration of each individual cytokine determined by measuring orange fluorescence produced by a complex of a biotinylated cytokine-specific antibody and streptavidin-phycoerythrin. The lower limit of quantification for all assays was 20 pg/mL with the exception of IL-8 which was 100 pg/mL. The inter-assay precision was less than 25%CV for all analytes at all control levels both pre-study and in-study. The percent recovery ranged from 83 to 108% pre-study and 90 to 125% in-study. In a linearity assessment, a 15,000 pg/mL multi-analyte control could be diluted 1:50 and maintain expected accuracy. We measured the cytokine concentrations in more than 2000 serum samples from patients with sepsis. Multiplex results for IL-6 were compared to a conventional commercially available ELISA kit. The degree of agreement between the two methods as measured by the concordance correlation coefficient was 84.5%. Multiplex results were 2.36-fold higher than ELISA values on the average. After adjusting for this mean difference, the 95% empirical limits of agreement for the ratio of individual sample values were 0.33, 2.65. This multiplex immunoassay provided simultaneous measurement of circulating cytokines using 80% less patient specimen compared to traditional approaches and at a significantly decreased cost. Efficient use of this platform requires process improvements to fully maximize the positive impact of multiplex assays in clinical drug development.

Cytokines↗

A simple and rapid single-step multiplex RT-PCR to detect Norovirus, Astrovirus and Adenovirus in clinical stool samples.

A single-step multiplex reverse transcription-polymerase chain reaction (RT-PCR) assay that detects and identifies Norovirus, Astrovirus and Adenovirus in clinical stool samples is described. Four hundred sixty stool samples were tested from patients with non-rotavirus acute gastroenteritis, that were either stored at -80 degrees C and tested retrospectively, or tested immediately after viral nucleic acid extraction in a prospective manner, including outbreaks of gastroenteritis that occurred in Germany during the winter of 2003. The multiplex RT-PCR was validated against simplex RT-PCR with published primers for Norovirus (JV12/JV13 and p289/p290) and Astrovirus (Mon340/348), and against simplex PCR for Adenovirus. In both retrospective and prospective settings, the multiplex RT-PCR was equally sensitive and specific in detecting non-rotavirus infections compared with simplex RT-PCR/PCR. The specificity of the multiplex RT-PCR was assessed by sequencing of the amplicons that showed high nucleotide identities to Norovirus genogroup I/1, I/4, II/2, or II/4 clades, as well as to Astrovirus serotypes 1, 2, 4, or 8. The multiplex RT-PCR was also more sensitive than Astrovirus and Norovirus antigen enzyme immunoassays (IDEIA, Dako), as well as Astrovirus isolation in cell culture. This novel multiplex RT-PCR is an attractive technique for the rapid, specific, and cost-effective laboratory diagnosis of non-rotavirus acute gastroenteritis.

Adenoviridae↗

Automated methods for multiplexed pathogen detection.

Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cycler where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides "live vs. dead" capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.

Automation↗

Damage formation and repair efficiency in the p53 gene of cell lines and blood lymphocytes assayed by multiplex long quantitative polymerase chain reaction.

We examined ultraviolet (UV) irradiation and cisplatin treatment damage formation and repair efficiency in the p53 tumor suppressor gene of various cultured cell lines and lymphocytes using a nonradioactive multiplex long quantitative polymerase chain reaction (QPCR) assay, which amplified a 7-kb fragment of the target gene and a 500-bp fragment of the template control to successfully increase the sensitivity and reliability of the assay. The multiplex long QPCR detected a lesion frequency of 0.63 lesions/10kb/10J/m(2) in the p53 gene of fibroblast cells. In addition, the multiplex long QPCR assay detected pronounced differences in the repair of UV damage in the p53 gene among repair-proficient CRL-1475 cells and repair-deficient XP-A and XP-C cells. The multiplex long QPCR assay was also evaluated as a sensitive assay for the detection of DNA damage induced by cisplatin. The data indicated that the lesion frequency in the p53 gene was 1.27-1.75 times higher in the H23 cisplatin-sensitive cell than in the H1435 cisplatin-resistant cell at the IC(70) dose. After 8-h and 24-h repair periods, only 13 and 75% of cisplatin-induced damage had been removed in the H23 cells, whereas these values were 92 and 100% in the H1435 cells. In addition, our data indicate that multiplex long QPCR is a sensitive method for validly estimating repair in freshly isolated lymphocytes. The results suggest that the current protocol of the multiplex long QPCR method can be used to assess the damage formation and repair efficiency of various agents at biologically relevant doses and to allow a more precise determination of gene-specific repair in disease susceptibility and drug resistance in epidemiological studies.

Autoradiography↗

Multiplexing and transmission of RF signals using an optical fiber

Ultrasonic non-destructive testing systems designed to control huge structures normally use several transducers in the reception stage. To avoid increasing the cost of electronics, a multiplexer is used to send all received signals to the same processing module. Traditionally, transmission of such signals is carried out using copper cables. For special applications (i.e. continuous monitoring of nuclear plants) metallic cables are not suitable because of their high sensitivity to electromagnetic perturbations. Moreover, the multiplexing is made electronically. When the distance between the transducers and the reception unit is large and/or electromagnetic noise is important, signal degradation takes place. The proposed system implements the transmission and multiplexing of ultrasonic electrical signals obtained by means of broadband transducers (up to 1 MHz), using an optical fiber. Optical fibers are made of dielectric materials (silica or plastic) so they are inherently passive to electromagnetic noise. Wavelength division multiplexing is utilized for adding channels to the system by means of fiber optic couplers and different light sources. The wavelengths of the optical signals utilized are located far apart in the optical spectrum in order to avoid serious crosstalk in transmission. The limit to the number of multiplexed channels depends on the optical fiber selected, the spectrum of the light sources and the wavelength division multiplexers or couplers utilized.

Journal Article↗