PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PM2.5”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Windblown dust contributes to high PM2.5 concentrations.

The revised National Ambient Air Quality Standards for PM include fine particulate standards based upon mass measurements of PM2.5. It is possible in arid and semi-arid regions to observe significant coarse mode intrusion in the PM2.5 measurement. In this work, continuous PM10, PM2.5, and PM1.0 were measured during several windblown dust events in Spokane, WA. PM2.5 constituted approximately 30% of the PM10 during the dust event days, compared with approximately 48% on the non-dusty days preceding the dust events. Both PM10 and PM2.5 were enhanced during the dust events. However, PM1.0 was not enhanced during dust storms that originated within the state of Washington. During a dust storm that originated in Asia and impacted Spokane, PM1.0 was also enhanced, although the Asian dust reached Washington during a period of stagnation and poor dispersion, so that local sources were also contributing to high particulate levels. The "intermodal" region of PM, defined as particles ranging in aerodynamic size from 1.0 to 2.5 microns, was found to represent a significant fraction of PM2.5 (approximately 51%) during windblown dust events, compared with 28% during the non-dusty days before the dust events.

Air Pollution↗

Determination of source contributions to ambient PM2.5 in Kaohsiung, Taiwan, using a receptor model.

Ambient particulates of PM2.5 were sampled at three sites in Kaohsiung, Taiwan, during February and March 1999. In addition, resuspended PM2.5 collected from traffic tunnels, paved roads, fly ash of a municipal solid waste (MSW) incinerator, and seawater was obtained. All the samples were analyzed for twenty constituents, including water-soluble ions, organic carbon (OC), elemental carbon (EC), and metallic elements. In conjunction with local source profiles and the source profiles in the model library SPECIATE EPA, the receptor model based on chemical mass balance (CMB) was then applied to determine the source contributions to ambient PM2.5. The mean concentration of ambient PM2.5 was 42.69-53.68 micrograms/m3 for the sampling period. The abundant species in ambient PM2.5 in the mass fraction for three sites were OC (12.7-14.2%), SO4(2-) (12.8-15.1%), NO3- (8.1-10.3%), NH4+ (6.7-7.5%), and EC (5.3-8.5%). Results of CMB modeling show that major pollution sources for ambient PM2.5 are traffic exhaust (18-54%), secondary aerosols (30-41% from SO4(2-) and NO3-), and outdoor burning of agriculture wastes (13-17%).

Agriculture↗

Design of a cost-effective weighing facility for PM2.5 quality assurance.

The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods (Document 2.12) requires conditioning of PM2.5 filters at 20-23 degrees C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed +/-2 degrees C and +/-5% RH during the conditioning period. The quality assurance team at EPA Region 2's regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements. The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA's Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, +/-0.2 degrees C and +/-0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 microg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.

Air Pollutants↗

Analysis of a summertime PM2.5 and haze episode in the mid-Atlantic region.

Observations of the mass and chemical composition of particles less than 2.5 microm in aerodynamic diameter (PM2.5), light extinction, and meteorology in the urban Baltimore-Washington corridor during July 1999 and July 2000 are presented and analyzed to study summertime haze formation in the mid-Atlantic region. The mass fraction of ammoniated sulfate (SO4(2-)) and carbonaceous material in PM2.5 were each approximately 50% for cleaner air (PM2.5< 10 microg/m3) but changed to approximately 60% and approximately 20%, respectively, for more polluted air (PM2.5>30 microg/m3). This signifies the role of SO4(2-) in haze formation. Comparisons of data from this study with the Interagency Monitoring of Protected Visual Environments network suggest that SO4(2-) is more regional than carbonaceous material and originates in part from upwind source regions. The light extinction coefficient is well correlated to PM2.5 mass plus water associated with inorganic salt, leading to a mass extinction efficiency of 7.6 +/- 1.7 m2/g for hydrated aerosol. The most serious haze episode occurring between July 15 and 19, 1999, was characterized by westerly transport and recirculation slowing removal of pollutants. At the peak of this episode, 1-hr PM2.5 concentration reached approximately 45 microg/m3, visual range dropped to approximately 5 km, and aerosol water likely contributed to approximately 40% of the light extinction coefficient.

Air Movements↗

Particulate matter in California: part 2--Spatial, temporal, and compositional patterns of PM2.5, PM10-2.5, and PM10.

Geographic and temporal variations in the concentration and composition of particulate matter (PM) provide important insights into particle sources, atmospheric processes that influence particle formation, and PM management strategies. In the nonurban areas of California, annual-average PM2.5 and PM10 concentrations range from 3 to 10 microg/m3 and from 5 to 18 microg/m3, respectively. In the urban areas of California, annual-averages for PM2.5 range from 7 to 30 microg/m3, with observed 24-hr peaks reaching levels as high as 160 microg/m3. Within each air basin, exceedances are a mixture of isolated events as well as periods of elevated PM2.5 concentrations that are more prolonged and regional in nature. PM2.5 concentrations are generally highest during the winter months. The exception is the South Coast Air Basin, where fairly high values occur throughout the year. Annual-average PM2.5 mass, as well as the concentrations of major components, declined from 1988 to 2000. The declines are especially pronounced for the sulfate (SO4(2-)) and nitrate (NO3-) components of PM2.5 and PM10) and correlate with reductions in ambient levels of oxides of sulfur (SOx) and oxides of nitrogen (NOx). Annual averages for PM10-2.5 and PM10 exhibited similar downwind trends from 1994 to 1999, with a slightly less pronounced decrease in the coarse fraction.

Aerosols↗

Analysis of PM2.5 and PM10 in the atmosphere of Mexico City during 2000-2002.

During the last 10 years, high atmospheric concentrations of airborne particles recorded in the Mexico City metropolitan area have caused concern because of their potential harmful effects on human health. Four monitoring campaigns have been carried out in the Mexico City metropolitan area during 2000-2002 at three sites: (1) Xalostoc, located in an industrial region; (2) La Merced, located in a commercial area; and (3) Pedregal, located in a residential area. Results of gravimetric and chemical analyses of 330 samples of particulate matter (PM) with an aerodynamic diameter less than 2.5 microm (PM2.5) and PM with an aerodynamic diameter less than 10 microm (PM10) indicate that (1) PM2.5/PM10 average ratios were 0.42, 0.46, and 0.52 for Xalostoc, La Merced, and Pedregal, respectively; (2) the highest PM2.5 and PM10 concentrations were found at the industrial site; (3) PM2.5 and PM10 concentrations were lower at nighttime; (4) PM2.5 and PM10 spatial averages concentrations were 35 and 76 microg/m3, respectively; and (5) when the PM2.5 standard was exceeded, nitrate, sulfate, ammonium, organic carbon, and elemental carbon concentrations were high. Twenty-four hour averaged PM2.5 concentrations in Mexico City and Sao Paulo were similar to those recorded in the 1980s in Los Angeles. PM10 concentrations were comparable in Sao Paulo and Mexico City but 3-fold lower than those found in Santiago.

Aerosols↗

Loss of PM2.5 nitrate from filter samples in central California.

Evaporative loss of particulate matter (with aerodynamic diameter < 2.5 microm, [PM2.5]) ammonium nitrate from quartz-fiber filters during aerosol sampling was evaluated from December 3, 1999, through February 3, 2001, at two urban (Fresno and Bakersfield) and three nonurban (Bethel Island, Sierra Nevada Foothills, and Angiola) sites in central California. Compared with total particulate nitrate, evaporative nitrate losses ranged from < 10% during cold months to > 80% during warm months. In agreement with theory, evaporative loss from quartz-fiber filters in nitric acid denuded samplers is controlled by the ambient nitric acid-to-particulate nitrate ratio, which is determined mainly by ambient temperature. Accurate estimation of nitrate volatilization requires a detailed thermodynamic model and comprehensive chemical measurements. For the 14-month average of PM2.5 acquired on Teflon-membrane filters, measured PM2.5 mass was 8-16% lower than actual PM2.5 mass owing to nitrate volatilization. For 24-hr samples, measured PM2.5 was as much as 32-44% lower than actual PM2.5 at three California Central Valley locations.

Aerosols↗

What is responsible for the carcinogenicity of PM2.5?

AIMS: To test whether exposure to known chemical carcinogens in the atmosphere is capable of explaining the association between concentrations of PM2.5 and lung cancer mortality observed in the extended ACS Cohort Study. METHODS: Taking account of possible cancer latency periods, lung cancer rates due to exposure to As, Cr(VI), Ni, and polycyclic aromatic hydrocarbons (PAHs) were calculated based on a review of historic measurements from the United States and the use of unit risk factors. The predicted rates were compared with rates of cancer attributable to PM2.5 derived from data in the ACS study. RESULTS: Despite many uncertainties, the lung cancer rates predicted due to exposure to US urban concentrations of the carcinogenic substances arsenic, nickel, chromium, and PAHs measured in 1960 and earlier (and hence allowing for a latency period) were within the range predicted on the basis of the ACS Cohort Study due to exposure of PM2.5. There are, however, many caveats, most particularly that for the chemical carcinogens to be responsible for the effects attributed to PM2.5 by Pope and colleagues, the concentrations of chemical carcinogens at the time of relevant exposures would need to be correlated with the concentrations of PM2.5 in US urban areas measured between 1979 and 2000 and used in the ACS study. CONCLUSIONS: While many uncertainties remain, it appears plausible that known chemical carcinogens are responsible for the lung cancers attributed to PM2.5 exposure in the extended ACS Cohort Study. However, the possibility should not be ruled out that particulate matter is capable of causing lung cancer independent of the presence of known carcinogens.

Carcinogens↗

Laboratory and field evaluation of measurement methods for one-hour exposures to O3, PM2.5, and CO.

While researchers have linked acute (less than 12-hr) ambient O3, PM2.5, and CO concentrations to a variety of adverse health effects, few studies have characterized short-term exposures to these air pollutants, in part due to the lack of sensitive, accurate, and precise sampling technologies. In this paper, we present results from the laboratory and field evaluation of several new (or modified) samplers used in the "roll-around" system (RAS), which was developed to measure 1-hr O3, PM2.5, and CO exposures simultaneously. All the field evaluation data were collected during two sampling seasons: the summer of 1998 and the winter of 1999. To measure 1-hr O3 exposures, a new active O3 sampler was developed that uses two nitrite-coated filters to measure O3 concentrations. Laboratory chamber tests found that the active O3 sampler performed extremely well, with a collection efficiency of 0.96 that did not vary with temperature or relative humidity (RH). In field collocation comparisons with a reference UV photometric monitor, the active O3 sampler had an effective collection efficiency ranging between 0.92 and 0.96 and a precision for 1-hr measurements ranging between 4 and 6 parts per billion (ppb). The limits of detection (LOD) of this method were 9 ppb-hr for the chamber tests and approximtely 16 ppb-hr for the field comparison tests. PM2.5 and CO concentrations were measured using modified continuous monitors--the DustTrak and the Langan, respectively. A size-selective inlet and a Nafion dryer were placed upstream of the DustTrak inlet to remove particles with aerodynamic diameters greater than 2.5 microm and to dry particles prior to the measurements, respectively. During the field validation tests, the DustTrak consistently reported higher PM2.5 concentrations than those obtained by the collocated 12-hr PM2.5 PEM samples, by approximately a factor of 2. After the DustTrak response was corrected (correction factor of 2.07 in the summer and 2.02 in the winter), measurements obtained using these methods agreed well with R2 values of 0.87 in the summer and 0.81 in the winter. The results showed that the DustTrak can be used along with integrated measurements to measure the temporal and spatial variation in PM2.5 exposures. Finally, during the field validation tests, CO concentrations measured using the Langan were strongly correlated with those obtained using the reference method when the CO levels were above the LOD of the instrument [approximately 1 part per million (ppm)].

Carbon Monoxide↗

[Study on mouse pulmonary acute injury induced by air-borne PM2.5].

OBJECTIVE: In order to study the acute toxicity of PM2.5 and to explore the role of immunoreaction and oxidative stress in mouse pulmonary acute injury induced by PM2.5. METHODS: Kunming mice were randomly divided into five groups including blank control group, saline control group, three level PM2.5 (low, middle and high) groups. Three level PM2.5 groups were inoculated with suspensions of PM2.5 via trachea for 24 hours and saline control group were inoculated saline, Pulmonary pathological injury and bronchoalveolar lavage fluid (BALF) of all mice were later examined, including the level of LDH, AKP, ACP, ALB, NO, NOS, MDA, SOD, activities of TNF-alpha, IL-1 and phagocytosis of Alveolar macrophages (AM). RESULTS: The amount of LDH, AKP, ACP, ALB, NO, NOS, MDA and activities of TNF-alpha, IL-1 in exposed groups were significantly higher than those in control(P < 0.05), and at the same time the amount of SOD and phagocytosis of AM decreased significantly (P < 0.05). Dose-response relationships were observed in all indexes. CONCLUSION: Air-borne PM2.5 could have acute toxic effects on mouse pulmonary cells and membrane tissues via immunotoxicity and oxidative stress injury.

Air Pollutants↗

Characteristics of PM2.5 in rural areas of southern Jiangsu Province, China.

To understand pollution level and possible sources of atmospheric fine particulates in rural areas of southern Jiangsu Province of China, samples of PM2.5 were collected and analyzed in Xueyan Town and Taihu Lake Station over three seasons from July 2002 to January 2003. The mass concentrations of PM2.5 and 14 principal component elements were obtained. The results showed that pollution of PM2.5 was serious and the concentration levels of S, Zn, Pb and As were similar to city. There are different seasonal distribution laws of pollutant elements in PM2.5 between two sampling sites, probably due to contribution of local sources, medium or long distance transportation of fine particulates and complicated meteorological conditions. The enrichment levels of S, Zn, Pb, As, K were high, reflecting the influence of anthropogenic activities. Particularly enrichment level of S was much higher in summer, which was probably related to meteorological condition. The result of principal components analysis showed major sources of PM2.5 included crustal resuspension, coal burning, metal processing industry or waste incineration, vehicular emission, which suggests anthropogenic activities is of important influence on PM2.5 in rural areas of southern Jiangsu Province.

Air Pollutants↗

[Applications of a rat model of chronic bronchitis on toxicity of PM2.5].

OBJECTIVE: To study the acute toxicity of PM2.5 to the rats with chronic bronchitis and the control rats and the difference between the model rats and the control rats on PM2.5 toxicity. METHODS: With the use of an intratracheal instillation, both groups were exposed to suspensions of PM2.5. After three times, the levels of ALB, LDH, AKP, MDA and GSH in bronchoalveolar lavage fluid (BALF) were analyzed. RESULTS: PM2.5 could induce the acute toxicity to both model rats and control rats, and dose-response relationships were observed in all indexes. In model rats, the levels of ALB, LDH, AKP, and MDA were higher in control rats( P < 0.05), while the levels of GSH were lower in control rats (P < 0.05). CONCLUSION: PM2.5 could have acute toxic effects on both model rats and health rats, and the rats with chronic bronchitis are more susceptible to PM2.5 than health rats.

Air Pollutants↗

Estimating fine particulates less than 2.5 microns in aerodynamic diameter (PM2.5) from airport visibility data in California.

Methods were developed for estimating fine particulates less than 2.5 microns in aerodynamic diameter (PM2.5) from airport visibility data which detected seasonality and allowed for possible site- and season-specific regressions of PM2.5 on visibility. The methods were applied to nine airports in California in order to produce estimates of PM2.5 for the years 1966-1986 based on 1,767 paired PM2.5/visibility data points where PM2.5 had been measured at a monitoring station near the airport. General F-tests indicated that site- and season-specific regression equations resulted in a statistically significant reduction in residual error. The split halves correlation for estimating PM2.5 from visibility over all areas was 0.82. The methods were used to estimate long-term concentrations of ambient PM2.5 for an epidemiological cohort of 1,868 individuals.

Air Pollutants↗

Collection and characterization of a bulk PM2.5 air particulate matter material for use in reference materials.

A contemporary PM2.5 (particulate matter smaller than 2.5 microns aerodynamic diameter) aerosol material from an urban site has been collected for the production of a new standard reference material that will be made available for the development of new PM2.5 air quality standards. Air particulate matter corresponding to the PM2.5 fraction was collected at an established Environmental Protection Agency monitoring site in Baltimore, Maryland. The air-sampling system that has been constructed for this collection separates fine particles with a cyclone separator and deposits them onto an array of Teflon membrane filters. The fine air particulate material is removed by ultrasonication or by mechanical means and collected for further preparation of standards. The composition of the collected PM2.5 aerosol, as well as the composition of the deposited PM2.5 aerosol, are determined by instrumental nuclear activation analysis and other techniques.

Air Pollutants↗

First assessment of the PM10 and PM2.5 particulate level in the ambient air of Belgrade city.

INTENTION, GOAL, SCOPE, BACKGROUND: As the strong negative health effect of exposure to the inhalable particulate matter PM10 in the urban environment has been confirmed, the study of the mass concentrations, physico-chemical characteristics, sources, as well as spatial and temporal variation of atmospheric aerosol particles becomes very important. OBJECTIVE: This work is a pilot study to assess the concentration level of ambient suspended particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade central urban area. Average daily concentrations of PM10 and PM2.5 have been measured at three representative points in the city between June 2002 and December 2002. The influence of meteorological parameters on PM10 and PM2.5 concentrations was analyzed, and possible pollution sources were identified. METHODS: Suspended particles were collected on Pure Teflon filters by using a Mini-Vol low-volume air sampler (Airmetrics Co., Inc.; 5 l min(-1) flow rate). Particle mass was determined gravimetrically after 48 h of conditioning in a desiccator, in a Class 100 clean room at the temperature T = 20 degrees C and at about 50% constant relative humidity (RH). RESULTS AND DISCUSSION: Analysis of the PM10 data indicated a marked difference between season without heating--(summer; mean value 56 microg m(-3)) and heating season--(winter; mean value 96 microg m3); 62% of samples exceeded the level of 50 microg m(-3). The impact of meteorological factors on PM concentrations was not immediately apparent, but there was a significant negative correlation with the wind speed. CONCLUSIONS: The PM10 and PM2.5 mass concentrations in the Belgrade urban area had high average values (77 microg m(-3) and 61 microg m(-3)) in comparison with other European cities. The main sources of particulate matter were traffic emission, road dust resuspension, and individual heating emissions. When the air masses are coming from the SW direction, the contribution from the Obrenovac power plants is evident. During days of exceptionally severe pollution, in both summer and winter periods, high production of secondary aerosols occurred, as can be seen from an increase in PM2.5 in respect to PM10 mass concentration. RECOMMENDATION AND OUTLOOK: The results obtained gave us the first impression of the concentration level of particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade ambient air. Due to measured high PM mass concentrations, it is obvious that it would be very difficult to meet the EU standards (EEC 1999) by 2010. It is necessary to continue with PM10 and PM2.5 sampling; and after comprehensive analysis which includes the results of chemical and physical characterization of particles, we will be able to recommend effective control measures in order to improve air quality in Belgrade.

Aerosols↗

Assaying particle-bound polycyclic aromatic hydrocarbons from archived PM2.5 filters.

Airborne particulate matter contains numerous organic species, including several polycyclic aromatic hydrocarbons (PAHs) that are known or suspected carcinogens. Existing methods for measuring airborne PAHs are complex and costly, primarily because they are designed to collect both gas-phase and particle-phase PAH constituents. Here, we report an assay for measuring particle-bound PAHs in archived filters from the network of U.S. monitoring stations for particles less than 2.5 microm in diameter (PM2.5), without the need for deploying specialized samplers. PAHs are extracted from Teflon filters with dichloromethane, concentrated, and measured at trace levels using gas chromatography-mass spectrometry. Although PAHs with 3-6 aromatic rings can be assayed, results are only unambiguously accurate for compounds with 5- or 6-rings, due to variable vaporization losses of the more volatile 3- and 4-ring compounds during sampling and/or storage. The method was evaluated for sensitivity, recovery, precision, and agreement of paired air samples, using PM2.5 samplers locally in Chapel Hill, NC. Additionally, three sets of archived samples were analyzed from a study of PM2.5 in the Czech Republic. Levels of some 4-ring and all 5- and 6-ring PAHs in both the local and Czech samples were consistent with published results from investigations employing PAH-specific air samplers. This work strongly suggests that assessment of particle-bound 5- and 6-ring PAHs from archived PM2.5 filters is quantitatively robust. The assay may also be useful for selected 4-ring compounds, notably chrysene and benzo(a)anthracene, if PM2.5 filters are stored under refrigeration.

Filtration↗

Oxidative potential of fresh vs. O&#x2083;-aged PM2.5 across urban and rural sources in China.

Fine particulate matter (PM2.5) is a major health risk, yet its impacts are still largely assessed using mass concentration, which does not capture toxicity. Recently, oxidative potential (OP) has emerged as a more relevant metric, reflecting the ability of particles to generate reactive oxygen species. A current challenge, especially in China, is understanding how emission sources and ozone (O3) aging affect PM2.5 toxicity, given that O3 is an increasingly important pollutant there. A work by Ma and co-workers published in J. Environ. Sci. (doi.org/10.1016/j.jes.2024.04.023) addressed this by evaluating the OP of fresh and O3-aged PM2.5 from multiple sources in China using the dithiothreitol (DTT) assay. Biomass burning particles exhibited the highest OP, up to 35 times greater than suburban PM2.5, driven by water-soluble organics and transition metals. While O3 aging generally reduced OP, it also induced complex chemical transformations. These findings highlight that PM2.5 toxicity is dynamic and source-dependent, underscoring the need to move beyond mass-based air quality metrics.

Particulate Matter↗

Characterization of atmospheric mineral components of PM2.5 in Beijing and Shanghai, China.

Weekly PM2.5 samples were collected for one year in Beijing and Shanghai and the crustal elements analyzed to investigate the concentration levels and temporal variations of ambient fine mineral dust. The mass concentrations of Al, Si, Ca, Mg, and Fe exhibited similar significant weekly variations in both Beijing and Shanghai. The annual average PM2.5 concentrations of major crustal elements ranged from 0.27 microg m-3 Mg to 2.48 microg m-3 Si in Beijing, which were 1.40-2.24 times higher than those in Shanghai. Their PM-weighted values were comparable between the two cities. A distinct seasonal pattern was present for these crustal elements with the highest concentrations during the spring in Beijing and during the winter in Shanghai, and the lowest concentrations during the summer in both cities. During the dusty spring of 2000 in Beijing, soil dust was the second most abundant PM2.5 constituent with a contribution as high as 18.6%, over twice that in the winter. The highest fine soil concentration (37.8 microg m-3) and mass percentage (41.6%) occurred in the same week of intensive dust events impacting Beijing. The impact of dust storms complicates the goal of reducing PM2.5 in Beijing. Ca originating from construction activities appears to be a significant PM2.5 contributor as well.

Air Pollutants↗