PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polystyrenes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Deposition of Oral Bacteria and Polystyrene Particles to Quartz and Dental Enamel in a Parallel Plate and Stagnation Point Flow Chamber.

The aim of this paper is to determine to what extent (i) deposition of oral bacteria and polystyrene particles, (ii) onto quartz and dental enamel with and without a salivary conditioning film, (iii) in a parallel plate (PP) and stagnation point (SP) flow chamber and at common Peclet numbers are comparable. All three bacterial strains showed different adhesion behaviors, and even Streptococcus mitis BMS, possessing a similar cell surface hydrophobicity as polystyrene particles, did not mimic polystyrene particles in its adhesion behavior, possibly as a result of the more negative zeta potentials of the polystyrene particles. The stationary endpoint adhesion of all strains, including polystyrene particles, was lower in the presence of a salivary conditioning film, while also desorption probabilities under flow were higher in the presence of a conditioning film than in its absence. Deposition onto quartz and enamel surfaces was different, but without a consistent trend valid for all strains and polystyrene particles. It is concluded that differences in experimental results exist, and the process of bacterial deposition to enamel surfaces cannot be modeled by using polystyrene particles and quartz collector surfaces. Copyright 1999 Academic Press.

Journal Article↗

Molecular dynamics of a polymer in mixed solvent: atactic polystyrene in a mixture of cyclohexane and N,N-dimethylformamide.

Local structural and dynamic properties of atactic polystyrene in a mixed solvent of cyclohexane (CH) and N,N-dimethylformamide (DMF) have been investigated using molecular dynamics simulations. We measure local conformations in the polymer and classify them by distance and angle distribution histograms. End-to-end distances and structure factors are employed to describe the static structure of polystyrene chains. Polystyrene concentration, including 1.6%, 4.8%, and 14% (by weight), and solution temperatures of 300, 330, or 360 K are used to elucidate the concentration and temperature dependencies of the solvation by the two solvents. Both solvent molecules preferentially approach the phenyl rings. At lower temperatures, polystyrene dissolves more favorably in cyclohexane. With rising temperature DMF molecules approach more closely with the oxygen oriented toward the phenyl rings. Additionally, the global and segmental relaxation times of the chains decrease and the system becomes more homogeneous. The segmental and global dynamics of polystyrene show different concentration behaviors: the reorientation times of solvent molecules and segments of polystyrene increase with concentration while the global dynamics of polystyrene decelerates as the concentration is changed from 1.6% to 4.8% but accelerates when the concentration rises to 14%. We conclude that the change of concentration from 4.8% to 14% qualitatively marks the change from a dilute to a semidilute solution. The diffusion constants of the small molecules and corresponding activation energies have also been measured. Our simulation data are compared with available experimental results and we find a satisfactory agreement.

Journal Article↗

Direct adsorption of ssDNA to polystyrene for characterization of the DNA/anti-DNA interaction, and immunoassay for anti-DNA autoantibody in New Zealand White mice.

DNA was adsorbed directly to polystyrene in concentrated NaCl (1.2 M) during simultaneous denaturation to single stranded form by high pH (12.0). Adsorption of single stranded DNA to polystyrene under these conditions (HsDNA) was complete within 15 min. DNA was not dissociated from polystyrene by NaCl concentrations as high as 5.0 M, nor by Tween 20 concentrations up to 50%. The method was ineffective for dT15 adsorption to polystyrene. HsDNA adsorption to polystyrene was compared to an indirect method in which methylated bovine serum albumin (mBSA) was adsorbed to polystyrene after which DNA was electrostatically bound to mBSA. DNA/mBSA interaction was affected by as low as 0.3 M NaCl. Using the DNA/mBSA assay, sera obtained from New Zealand White (NZW) mice showed IgG anti-DNA activity in approximately 50% of mice tested. HsDNA assay found greater than 62% of NZW mice have 10 micrograms anti-ssDNA or more per ml serum. Complex formation involving C1q complement and ssDNA in HsDNA assay were shown to be negligible. Anti-DNA autoantibody production by NZW implicated the NZW parental strain in autoimmunity of F1 progeny obtained from the New Zealand Black X NZW cross.

Adsorption↗

Polystyrene as an affinity chromatography matrix for the purification of antibodies.

Affinity chromatography is used for the purification of diagnostic polyclonal antibodies in order to ensure specificity. Most commonly, activated bead-formed agarose or its derivatives are used as gel matrices. Alternative matrix materials have been described, but as yet they do not appear to offer important advantages. In this study, pulverized polystyrene (PS 158K, BASF, Mannheim, Germany) was used as a solid phase for the immobilisation of bovine immunoglobulins (Ig). Affinity chromatography was performed using these coated polystyrene beads as the column matrix material in the purification of anti-bovine Ig. The polystyrene binding capacity for the different bovine Ig classes was compared using the Mancini single radial immunodiffusion technique, and ELISA procedures were used to monitor the antibody reactivity of purified and unpurified antibodies. The degree of purification was comparable to the most commonly used procedure using gel matrices from activated bead-formed agarose (e.g. CNBr-activated Sepharose 4B, Pharmacia/LKB Biotechnology, Uppsala, Sweden), but the antibody yield per ml column volume was distinctly lower. In order to raise the yield, such polystyrene bead columns with immobilized antigen can be re-used without loss of activity or larger column volumes can be used to raise the binding capacity. The polystyrene material is quite durable, chemically and immunologically inert and has a long shelf life. We conclude that polystyrene based affinity chromatography is efficient, simple and cheap.

Adsorption↗

Effect of the carbohydrate side-chain on the conformation of a glycoconjugate polystyrene in aqueous solution.

An oligomaltose-carrying polystyrene "glycoconjugate polystyrene" was synthesized by the homopolymerization of 4-vinylbenzylamine oligomaltonic amides, derived from maltose, maltotriose, maltopentaose, and maltoheptaose. The resultant amphiphilic glycoconjugate polystyrenes were dissolved in 0.1 M aqueous urea, and their structures characterized by small-angle X-ray scattering and molecular modeling. "Glycoconjugate polystyrene" was found to behave as a "molecular bottle brush", composed of a large pseudo-helical polystyrene backbone and carbohydrate brushes. A large pseudo-helical polystyrene backbone is formed by a random sequence of TT, TG, and/or TTGG. The results indicate that the cross-section of a backbone chain with smaller oligosaccharide side-chains is obliged to expand more than that with longer side-chains. Even with rigid hydrophilic pendant oligosaccharide chains, the larger pseudo-helix of the main chain could orient the side-chains so as to envelop the hydrophobic backbone in aqueous solution. Thus the conformation of the main chain is determined not only by the chemical nature of an oligosaccharide chain but also by its length.

Computer Simulation↗

AFM study of the behavior of polystyrene and glass particles during the electrodeposition of copper.

In this paper, the behavior of polystyrene and glass particles on a copper electrode during the electrodeposition of copper was studied using an atomic force microscope (AFM). Polystyrene or glass particles glued to the tip of the AFM cantilever were kept in contact with the surface of the electrode. The surface forces between the polystyrene or glass particle and the copper electrode were measured before, during, and after electrodeposition. These experiments revealed that glass particles do not make contact with the electrode, probably due to the repulsive hydration force. Polystyrene particles, on the other hand, make contact with the electrode, due to the attractive hydrophobic force. The AFM experiments were correlated with sedimentation co-deposition experiments of polystyrene and glass particles with copper. It was found that 80% of the polystyrene particles added to the plating solution incorporated with copper, while only 0.25% of the glass particles co-deposited under the same conditions.

Copper↗

Comparative efficacy of thallium adsorption by activated charcoal, prussian blue, and sodium polystyrene sulfonate.

BACKGROUND: Although Prussian blue is considered the antidote of choice for thallium poisoning, the lack of a Food and Drug Administration-approved pharmaceutical formulation has led to the search for other adsorbents. Activated charcoal has been demonstrated to adsorb thallium in vitro, and the similarity between thallium and potassium has led some authors to consider the use of sodium polystyrene sulfonate as a potential adsorbent. This experiment was designed to compare the relative thallium binding efficacy of these agents in a standard isotherm model. METHODS: A standard aqueous solution of thallium acetate buffered to pH 7.0 was agitated at 25 degrees C with activated charcoal, Prussian blue, or sodium polystyrene sulfonate at adsorbent:thallium ratios ranging from 1.5:1 to 100:1. In order to further simulate physiologic conditions, all trials were repeated in a solution containing 4 mmol/L potassium phosphate. After thorough agitation, the mixtures were allowed to settle and were centrifuged and filtered through a 0.22-micron filter. Supernatant thallium concentrations were measured by atomic absorption spectrophotometry. Langmuir isotherms were used to calculate the maximal adsorptive capacity of each adsorbent, using linear regression with Pearson's correlation coefficients (r). Maximal adsorptive capacities were compared statistically with a p < 0.05 considered significant. RESULTS: The maximal adsorptive capacities defined as milligrams of thallium per gram of adsorbent (shown with linear regression p and r values) were as follows: activated charcoal, 59.7 mg/g (p = 0.005, r = 0.995); Prussian blue, 72.7 mg/g (p = 0.004, r = 0.996); and sodium polystyrene sulfonate, 713 mg/g (p = 0.049, r = 0.951). All three values were statistically different from each other. At a physiologic potassium concentration, the maximal adsorptive capacities for activated charcoal and Prussian blue were essentially unchanged (58.3 mg/g and 69.8 mg/g, respectively, p > 0.05 for each vs trials without potassium), while the maximal adsorptive capacity for sodium polystyrene sulfonate fell to 39.1 mg/g (p = 0.003, r = 0.997, p = 0.005 vs sodium polystyrene sulfonate without potassium). CONCLUSIONS: This in vitro study confirms the utility of Prussian blue and activated charcoal as thallium adsorbents. Although sodium polystyrene sulfonate demonstrates exceptional in vitro adsorption of thallium, its greater affinity for potassium probably renders it clinically ineffective.

Adsorption↗

"Nonisolated-sensor" solid polystyrene absorbed dose measurements.

A "nonisolated-sensor" solid polystyrene calorimeter was constructed to test the role of thermal diffusion in limiting the length of irradiation time during which temperature measurements with nonisolated sensors could be made sufficiently free of drift for determining dose with radiation fields such as gamma rays, x rays, and high-energy electrons. From measured ratios of dose at 5.0 and 0.5 cm in polystyrene and comparisons to dose measurements with a polystyrene parallel-plate (pancake) ion chamber, it was shown that thermal diffusion is sufficiently small in polystyrene to permit accurate measurements for irradiation periods of less than 20 min. Comparison of the absorbed dose measurements and depth dose ratios with pancake ion chambers and calorimeter showed, that within the precision and accuracy of the two measuring systems, there is close agreement. The nonisolated-sensor solid polystyrene calorimeter has the interesting features of (i) simplicity of construction, (ii) simplicity of operation without vacuum or feedback for temperature control, (iii) capability of simultaneous measurements at several depths and off-axis positions, (iv) the very small thermal defect correction with polystyrene, and (v) operation with the calorimeter in any orientation.

Calorimetry↗

Nanoalloys based on clays: intercalated semicrystalline blends of syndiotactic polystyrene with poly(2,6-dimethyl-p-phenylene oxide).

Nanoalloys of syndiotactic polystyrene with poly(2,6-dimethyl-p-phenylene oxide) clay were prepared by a solution intercalation technique using 1,1,2,2-tetrachloroethane. A mixed intercalated/exfoliated morphology in the nanoalloys containing organo-clays is evinced by transmission electron microscopy. Thermal stability is found to improve with 5% by weight of organo-clays, but a reverse trend is observed by increasing the concentration of clay. The influence of montmorillonite clays in isothermal melt-crystallization behavior of blends was thoroughly investigated by using differential scanning calorimetry and wide-angle X-ray diffraction. A considerable change in polymorphic behavior of syndiotactic polystyrene is observed by the incorporation of different clays into the blends, and the temperature window of isothermal crystallization for the formation of a-crystals of syndiotactic polystyrene is found to broaden in the presence of organo-clays. In contrast, the pristine clay is found to induce only the beta-crystal of syndiotactic polystyrene at all the crystallization temperatures studied in this work. The amorphous component poly(2,6-dimethyl-p-phenylene oxide) affects the crystallinity of syndiotactic polystyrene adversely and favors the beta-form of syndiotactic polystyrene in blends; a-crystals are observed in the nano-alloys containing 20 wt% of poly(2,6-dimethyl-p-phenylene oxide). The crystalline morphology, as characterized by polarized optical microscopy, clearly indicates rapid formation of the alpha-form induced by the nanoscale dispersion of organo-clays in spherulites of smaller dimension.

Alloys↗

Use of sodium polystyrene sulfonate for reduction of plasma lithium concentrations after chronic lithium dosing in mice.

OBJECTIVES: Previous studies have shown that oral sodium polystyrene sulfonate lowers plasma lithium concentrations after acutely administered oral doses of lithium chloride. However, a significant proportion of lithium overdose cases resulting in morbidity and mortality are those in which exposure to lithium is chronic. This study was designed to determine whether multiple oral doses of sodium polystyrene sulfonate are effective in reducing plasma lithium concentrations after chronic dosing. DESIGN: Placebo-controlled animal study. INTERVENTIONS: One hundred thirty mice were given 75 mM lithium chloride in their drinking water for a period of 14 days. At the end of that period, half of the animals were given orogastric sodium polystyrene sulfonate at 5 g/kg/dose 0, 60, 120, 180, and 360 minutes after the cessation of lithium chloride; the remaining half received orogastric water at equivalent times. Subgroups of each group were sacrificed at 90, 150, 330, 480, 1440, and 2880 minutes after lithium chloride cessation and plasma analyzed for lithium content. Lithium concentrations were compared by analysis of variance and single degree of freedom contrasts. Significance was set at an alpha level of 0.05. RESULTS: Lithium concentration was lower overall in the animals treated with sodium polystyrene sulfonate (p < .0001) and specifically at 150, 330, and 480 minutes after lithium chloride cessation (p < .05). CONCLUSIONS: Repetitive oral doses of sodium polystyrene sulfonate effectively lowered plasma lithium concentrations. Further study may ultimately define a role for the use of sodium polystyrene sulfonate in the treatment of patients with chronic lithium toxicity.

Administration, Oral↗

Human plasma fibrinogen adsorption and platelet adhesion to polystyrene.

The purpose of this study was to further investigate the role of fibrinogen adsorbed from plasma in mediating platelet adhesion to polymeric biomaterials. Polystyrene was used as a model hydrophobic polymer; i.e., we expected that the role of fibrinogen in platelet adhesion to polystyrene would be representative of other hydrophobic polymers. Platelet adhesion was compared to both the amount and conformation of adsorbed fibrinogen. The strategy was to compare platelet adhesion to surfaces preadsorbed with normal, afibrinogenemic, and fibrinogen-replenished afibrinogenemic plasmas. Platelet adhesion was determined by the lactate dehydrogenase (LDH) method, which was found to be closely correlated with adhesion of 111In-labeled platelets. Fibrinogen adsorption from afibrinogenemic plasma to polystyrene (Immulon I(R)) was low and <10 ng/cm2. Platelet adhesion was absent on surfaces preadsorbed with afibrinogenemic plasma when the residual fibrinogen was low enough (<60 microg/mL). Platelet adhesion was restored on polystyrene preadsorbed with fibrinogen-replenished afibrinogenemic plasma. Addition of even small, subnormal concentrations of fibrinogen to afibrinogenemic plasma greatly increased platelet adhesion. In addition, surface-bound fibrinogen's ability to mediate platelet adhesion was different, depending on the plasma concentration from which fibrinogen was adsorbed. These differences correlated with changes in the binding of a monoclonal antibody that binds to the Aalpha chain RGDS (572-575), suggesting alteration in the conformation or orientation of the adsorbed fibrinogen. Platelet adhesion to polystyrene preadsorbed with blood plasma thus appears to be a strongly bivariate function of adsorbed fibrinogen, responsive to both low amounts and altered states of the adsorbed molecule.

Adsorption↗

Interactions of proteins in human plasma with modified polystyrene resins.

Investigations are reported on the composition of protein layers adsorbed from plasma to various modified polystyrene resins. As well as polystyrene itself, polystyrene bearing sulfonate groups in the benzene rings, and polystyrene sulfonate in which the sulfonate groups were converted to amino acid sulfamide, were investigated. Some of these resins were shown in previous work to have anticoagulant properties. To study the adsorption of proteins from plasma, the resins were exposed to citrate anticoagulated human plasma for 3 h. Adsorbed proteins were then eluted sequentially by 1M Tris buffer and 4% SDS solution, and examined by SDS-PAGE. The gel patterns were similar on all resins except polystyrene. From the MWs of the gel bands, the major protein component appeared to be fibrinogen. Smaller amounts of plasminogen, transferrin, albumin, and IgG were also present. In addition, Ouchterlony immunoassay of the eluates from one resin gave positive identification of complement C3, fibronectin, IgG, and IgM. Many other minor gel bands remain unidentified. A consistent finding for all resins was the presence of plasmin-type fibrinogen degradation products though the amounts varied with resin type. It is concluded from this (and from experiments showing FDP formation when fibrinogen was absorbed to the resins, from buffer containing a trace of plasminogen) that the functional groups in these materials promote the adsorption of plasminogen and its activation to a plasmin-like molecule. It appears from the substantial quantities of fibrinogen adsorbed to these materials after 3 h exposure to plasma that the Vroman effect (giving transient adsorption of fibrinogen) is not operative on these materials. It is hypothesized that specific interactions occur between fibrinogen and sulfonate groups.

Adsorption↗

Enhanced mineralized tissue adhesion to titanium over polystyrene assessed by the nano-scratch test.

The critical load determined by the scratch test is regarded to be a representative measure of coating adhesion in the field of engineering. This study aimed to evaluate the method for its usefulness for assessing the mineralized tissue-titanium interface strength. Osteoblastic cells derived from rat bone marrow were cultured on polystyrene, titanium-coated polystyrene, and titanium disks with either a machined or dual-acid etched surface. Nano-scratch testing was performed on mineralized tissue specimens at culture day 28. The scratch path was monitored by light microscopy until complete delamination of mineralized tissue from the substrate occurred, and the required force was recorded as the critical load. Energy-dispersive spectroscopic analysis was used to verify the delamination. The mean critical load values (+/- standard deviations) were as follows: polystyrene 31 mN (+/-1), titanium-coated polystyrene 67 mN (+/-4), machined titanium 76 mN (+/-4), DAE titanium 107 mN (+/-3), with statistical differences (P < 0.05; ANOVA). No elemental calcium and phosphorous were observed in the delaminated areas. The nano-scratch test applied to cultured mineralized tissue differentiated the critical load from various culture conditions: polystyrene vs. titanium; titanium with different surface topographies. Culturing mineralized tissue on titanium, especially on roughened surfaces, increased the tissue critical load. The nano-scratch test may be useful to evaluate mineralized tissue adhesion properties in titanium cultures.

Animals↗

Effect of polystyrene particles on lung microvascular permeability in isolated perfused rabbit lungs: role of size and surface properties.

The aim of this study was to investigate the role of particle number, total surface area, mass and surface chemical groups in (K(f,c)) changes. The lung effects of four different fine (110 nm) and ultrafine (24 nm) polystyrene particles have been tested in an isolated perfused rabbit lung model. Pulmonary microvascular permeability (K(f,c)) modifications were measured in response to intratracheal particle challenge. Polystyrene particles, mainly located in alveolar spaces and macrophages, induced a K(f,c) increase that was related to the total surface area and number of particles rather than to the instilled mass. Moreover, the positively charged amine-modified polystyrene particles were more effective in the K(f,c) response than the negatively charged carboxylate-modified polystyrene particles. We concluded that particle number and diameter that mathematically equally determined total surface area do not have the same importance in explaining the biological effects observed and that particle number could be an alternative to total surface area to describe the particle exposure. Furthermore, surface properties of polystyrene particles need to be considered to investigate the microvascular permeability changes measured in our model.

Animals↗

Interrelationships between soil microorganisms and polystyrene.

Transmission and scanning electron microscopy along with autoradiographic procedures were used for evaluating the interrelationship between soil microorganisms and polystyrene. Two hypotheses, allowing to explain the properties of polystyrene as a soil conditioner, were investigated: the first is concerned with a possible action of soil microorganisms on the compound; the second, reciprocally, with the polystyrene interference on microorganisms. Radioactivity translocation of 14C-Ecolyte-polystyrene along fungal hyphae and asexual fructification of strains, isolated from soil, as well as cytological modification at the cell wall level of the same microfungi, cultivated in the presence of polystyrene have been ascertained.

Cladosporium↗

New routes to the synthesis of amylose-block-polystyrene rod-coil block copolymers.

Hybrid block copolymers amylose-block-polystyrene were synthesized by covalent attachment of maltoheptaose derivatives to end-functionalized polystyrene and subsequent enzymatic grafting from polymerization. The maltoheptaose derivatives were attached by reductive amination or hydrosilation to amino- or SiH-terminated polystyrene (synthesized by anionic polymerization), respectively. The enzymatic polymerization could be started even though the primer-modified polystyrenes were insoluble in the medium of polymerization, i.e., citrate buffer. The polymerization kinetics show an interesting dependence on the molecular weight of polystyrene due to the micellar structure of the primer in water.

Amination↗

Modification of jute fibers with polystyrene via atom transfer radical polymerization.

Atom transfer radical polymerization (ATRP) was investigated as a method of covalently bonding polystyrene to jute (Corchorus capsularis) and as a possible approach to fiber composites with enhanced properties. Jute fibers were modified with a brominated initiator and subsequently ATRP modified to attach polystyrene and then examined using SEM, DSC, TGA, FTIR, XPS, elemental analysis, and Py-GC-MS. These techniques confirmed that polystyrene had been covalently bound to the fibers and consequently ATRP-modified jute fiber mats were used to prepare hot-pressed polystyrene composites. Composite specimens were tensile tested and fracture surfaces examined using SEM. Although SEM examination suggested different fracture modes between unmodified fiber and ATRP-modified samples, the tensile strength of modified samples was slightly lower on average than that of unmodified samples. For fiber composite applications, we conclude that further optimization of the ATRP method is required, possibly targeting higher and more uniform loading of polystyrene on the fibers.

Biocompatible Materials↗

A two step chemo-biotechnological conversion of polystyrene to a biodegradable thermoplastic.

A novel approach to the recycling of polystyrene is reported here; polystyrene is converted to a biodegradable plastic, namely polyhydroxyalkanoate (PHA). This unique combinatorial approach involves the pyrolysis of polystyrene to styrene oil, followed by the bacterial conversion of the styrene oil to PHA by Pseudomonas putida CA-3 (NCIMB 41162). The pyrolysis (520 degrees C) of polystyrene in a fluidized bed reactor (Quartz sand (0.3-0.5 mm)) resulted in the generation of an oil composed of styrene (82.8% w/w) and low levels of other aromatic compounds. This styrene oil, when supplied as the sole source of carbon and energy allowed for the growth of P. putida CA-3 and PHA accumulation in shake flask experiments. Styrene oil (1 g) was converted to 62.5 mg of PHA and 250 mg of bacterial biomass in shake flasks. A 1.6-fold improvement in the yield of PHA from styrene oil was achieved by growing P. putida CA-3 in a 7.5 liter stirred tank reactor. The medium chain length PHA accumulated was comprised of monomers 6, 8, and 10 carbons in length in a molar ratio of 0.046:0.436:1.126, respectively. A single pyrolysis run and four fermentation runs resulted in the conversion of 64 g of polystyrene to 6.4 g of PHA.

Biodegradation, Environmental↗