PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Program Design--changes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3Linked to original sources

Clinical efficacy and design changes of "fine bore" nasogastric feeding tubes: a seven-year experience involving 809 intubations in 403 patients.

We report here our clinical experiences of "fine bore" nasogastric feeding tubes. Data have been collated over a 7-year period (1978-1985). A total of 403 patients were intubated on 809 occasions. In the first retrospective study, the clinical use of 491 unweighted tubes was compared with that of fifty 3.5-g weighted tubes. No advantage was found in the use of the weighted tubes. In the second prospective controlled clinical trial, these results were confirmed. Forty-six patients were intubated on 76 occasions with an 85-cm open-ended, unweighted nasogastric feeding tube (Prima, Portex UK), and 57 patients were intubated on 79 occasions with a 91-cm 3.0-g weighted tube (Entriflex, Biosearch, Raritan, NJ). Mean duration of placement was similar in each case, and 62% of both types of tubes were inadvertently removed. Without exception, all the tubes remained in the stomach throughout. Disappointed with the similar and overall performance of both types of tubes, we initiated a design program which resulted in the development of two new nasogastric tubes, one weighted and one unweighted. The tubes were manufactured with polyurethane, rather than polyvinylchloride (PVC), which permitted an increase in diameter of the internal lumen which, in turn, was coated with water-activated lubricant to ease removal of the introducer wire. A specially modeled outflow port was incorporated into the tips of both tubes. The performance of the two new polyurethane nasogastric feeding tubes was assessed under controlled trial conditions; as a reference, a widely used PVC unweighted open-ended tube was used.(ABSTRACT TRUNCATED AT 250 WORDS)

Clinical Trials as Topic↗

Screening for Giardia/Cryptosporidium infections using an enzyme immunoassay in a centralized regional microbiology laboratory.

CONTEXT: Stool parasitologic testing for Giardia and Cryptosporidium (G/C) previously relied on staining (ie, modified iron hematoxylin-kinyoun), ethyl acetate concentration procedures, and microscopy (the stool ova and parasite method). In April 1999, a microplate enzyme immunoassay (EIA) (ProSpecT G/C, Remel, Inc, Lenexa, Kan) for routine screening of all stool specimens was implemented. OBJECTIVE: To determine the clinical and laboratory impact of this service change. DESIGN: Changes were made to the regional microbiology requisition so that physicians could order either a G/ C EIA screen or stool ova and parasite examination. During a 3-year period (May 1999 through April 2002), changes in physician ordering practice, the rate of detection of G/ C infections, and test turnaround times were monitored. The economic outcomes have also been studied and compared annually since implementation and up to the current fiscal year (2004). RESULTS: The following effects have been noted since G/ C EIA screening was implemented: (1) 70% of all stool parasite tests ordered were converted to G/C EIA screens versus stool ova and parasite tests, (2) stool parasitologic volumes decreased by up to 30% because of physicians ordering a single test per patient, (3) most stool parasite results (70%-80%) were reported within 24 hours of specimen receipt, and (4) the screening assay has improved detection of cryptosporidiosis cases. Although the G/C EIA tests cost more than stool ova and parasite examination, the equivalent of 1.8 full-time employees have been freed up to perform other duties. CONCLUSIONS: Routine stool G/C EIA screening in our region is not only clinically relevant but also improves the timeliness and efficiency of detection of these important enteric parasite infections.

Alberta↗

How surveys are changing at the U.S. Bureau of the Census.

"This article describes the survey activities of the U.S. Census Bureau and recent efforts by the bureau to move toward a more fully automated environment....[It] focuses on four areas in which the Census Bureau is changing its approach to surveys: (1) redesigning the questionnaire for the Current Population Survey to better reflect current labor force conditions; (2) redesigning the same questionnaire to gain advantages from computer-assisted interviewing; (3) redesigning the samples for household surveys to be used during the next decade, a task undertaken after every decennial census; and (4) progress in changing to a computer-assisted survey information collection (CASIC) system and developing a data management network for all Census Bureau surveys."

Americas↗

Family planning field research projects: balancing internal against external validity.

This report discusses the experience of a two-year family planning and maternal/child health project in Nepal. Although the project was planned as an experimental field research endeavor, a series of unanticipated events repeatedly compromised the internal validity of the project and forced design changes. While unexpected events are common in the history of most field projects, they present the research evaluator with the fundamental dilemma of trying to maintain a high degree of internal validity without sacrificing external validity. Rigid research designs with tight control over the introduction and measurement of experimental variables may serve to increase internal validity but they may also create an atypical and artificial situation that fails to mirror real field conditions and thus threatens external validity.

Community Health Services↗

[Evaluation and improvement of quality during practical training in primary health care at health centers of Murcia].

BACKGROUND: To describe the Public Health in Primary Health Care practice for medical students Program objectives, quality of training evaluation method, and implementation results. METHODS: 6 learning objectives were designed and training implemented in 3 Health Centers in the 90-91 academic course. Evaluation included the objectives level of difficulty, and homogeneity in achievement rates between objectives, within Centres and between Centres. Evaluation results were analyzed and used to design changes to increase homogeneity and achievement rates. Same evaluation was performed in the 91-92 academic course to document improvement. RESULTS: In the first evaluation there were highly significant differences in overall (p. < 0.00005) and by objectives (p. > 0.01) achievement rates between centers. Within centres between objectives difficulty was not homogeneous either (p. > 0.001). After implementing remedial actions, differences in difficulty and achievement rates within and between centres decreased. Increased homogeneity affected mostly to two previously less homogeneous objectives. CONCLUSIONS: Quality assurance methods can be successfully applied to improve training of clearly defined and quantified Primary Health Care learning objectives.

Health Services↗