PubMed HealthSearch

SEARCH · PubMed Health

Results for “Pulsatile Flow”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Adrenocortical hormone levels during cardiopulmonary bypass with and without pulsatile flow.

To determine the effect of hypothermic pulsatile and nonpulsatile cardiopulmonary bypass (CPB) with hemodilution on adrenocortical function we measured plasma levels of adrenocorticotropic hormone (ACTH), cortisol, aldosterone, and renin in two groups of patients. Group I, comprising 11 patients had routine CPB (nonpulsatile), and Group II, comprising 12 patients, had pulsatile flow during CPB (pulsatile). Both groups demonstrated comparable increases in cortisol, ACTH, and aldosterone with operation. Levels for all three hormones appeared to decline during CPB and then rose again in the post-CPB period. There were no significant differences between groups. Plasma renin activity gradually declined in a comparable manner in both groups. In the post-CPB period, renin activity was slightly higher in the nonpulsatile group (1.7 +/- 0.5 versus 0.8 +/- 0.2 ng/ml/hr, p less than 0.05). Correction for the effect of hemodilution demonstrated no decrease in cortisol and a slight increase in ACTH in both groups during CPB. Significant increases occurred in both groups during CPB in urinary Na+ excretion rate and urinary Na+/K+ ratio, more so for the nonpulsatile group. There was no correlation between urinary Na+/K+ ratios and either plasma cortisol or aldosterone levels. Thus routine CPB demonstrates no evidence of adrenocortical hypofunction and the addition of pulsatile flow produces little improvement.

Adrenal Cortex Hormones

Instantaneous cross-sectional flow velocity profiles: a comparative study of two ultrasound Doppler methods applied to an in vitro pulsatile flow model.

Two methods based on different techniques for construction of cross-sectional flow velocity profiles from Doppler ultrasound signals were compared: an intraluminal method using pulsed-wave Doppler echocardiography and an extraluminal method using two-dimensional (color) Doppler ultrasound. The methods were applied to an in vitro pulsatile flow model. With the intraluminal method, pulsed Doppler recordings obtained throughout several flow pulses at different positions across a tube were digitized, and cross-sectional flow velocity profiles were obtained by matching the onset of flow velocity at the various positions. With the extraluminal method, cross-sectional flow velocity profiles were obtained by time interpolation between the digital flow velocity data obtained from several flow velocity maps. The first flow velocity map was recorded at onset of flow and the following maps were incrementally delayed with 20 msec from one flow pulse to the next. The time lag caused by the time needed to update each of the flow velocity maps was compensated for by time interpolation between the sequentially recorded flow velocity maps. The cross-sectional flow velocity profiles obtained with the two methods were compared at identical positions within the tube model at equal flow settings and throughout the pulsatile flow periods. At three different flow settings with peak flow velocity of 0.3, 0.5, and 0.7 m/sec, the difference (mean +/- SD) between the obtained velocities were 0.01 +/- 0.04, -0.01 +/- 0.05, and -0.03 +/- 0.07 m/sec, respectively. The findings suggest that cross-sectional flow velocity profiles from pulsatile flow velocity recordings can be obtained equally well with both methods.

Blood Flow Velocity

[Clinical and experimental study of the production of renal hemodynamic effects of IABP-assisted pulsatile flow extracorporeal circulation].

Renal hemodynamics during IABP-assisted pulsatile flow extracorporeal circulation was assessed in terms of measurement values for intraoperative renal blood flow obtained by the local thermodilution method in human clinical patients. In addition, the effect of IABP on renal hemodynamics was investigated in an animal model of renal denervation in a study undertaken to elucidate the action mechanism of IABP. Eighteen patients with acquired heart disease were involved in the study and measured for the renal blood flow (RBF), cardiac output (CO), renal-systemic partition coefficient for blood flow (RBF/CO), renal vascular resistance (RVR) and perfusion pressure. In the pulsatile flow group, the RBF/CO increased as the number of pump runs increased, whole the RVR was conversely reduced with increasing pump runs. The experimental study without extracorporeal circulation was conducted on 19 mongrel dogs. During IABP runs RBF/CO increased, while the RVR decreased. After renal denervation, no noticeable influence of IABP upon renal hemodynamics was observed. Following a loading dose of noradrenaline (Norad), the RVR increased in a Norad concentration-dependent fashion, independently of IABP and renal denervation. These results indicate that IABP reduces the RVR and thereby exerts a favorable action on renal hemodynamics during pump times. The study thus warrants us to surmise that a mechanism involving the renal sympathetic nerves might play an important role in the production of favorable renal hemodynamic effects of IABP-assisted pulsatile flow extracorporeal circulation.

Animals

Plasma vasopressin levels and urinary flow during cardiopulmonary bypass in patients with valvular heart disease: effect of pulsatile flow.

The effect of pulsatile flow on plasma vasopressin levels during cardiopulmonary bypass (CPB) was studied in 20 patients undergoing open valve replacement. Routine bypass was used in 10 patients and the AVCO pulsatile bypass pump was utilized in the other 10. In Group I (nonpulsatile) during CPB, the vasopressin level was markedly elevated (3.1 +/- 2 to 80 +/- 22 pg/ml) as was urine flow (0.6 +/- 0.2 to 5.9 +/- 2 ml/min) and urine Na+ concentration (69 +/- 19 to 116 +/- 7 mEq/L). In Group II (pulsatile) during CPB, the vasopressin level (3.8 +/- 3 to 54 +/- 14 pg/ml), urine flow (0.6 +/- 0.1 to 16.2 +/- 4.8 ml/min), and urine Na+ concentrations (61 +/- 13 to 97 +/- 10 mEq/L) were also elevated. The rise in vasopressin and urine Na+ was less in the pulsatile group (p less than 0.05) whereas the urine flow was higher (p less than 0.05). To maintain comparable blood pressure, the pulsatile flow group required significantly higher flows (4.5 +/- 0.2 compared to 3.8 +/- 0.2; p less than 0.05). These data suggest that CPB produces a marked vasopressin stress response which is beyond the physiological range for an antidiuretic effect on the kidney. At these levels vasopressin can exert a vasopressor effect to maintain resistance and affect renal blood flow, as well as producing an Na+ diuresis. The addition of pulsatile flow creates a more physiological situation attenuating the vasopressin response and producing a decrease in systemic resistance and a less pronounced Na+ diuresis.

Arginine Vasopressin

Magnetic resonance imaging kappa-space segmentation using phase-encoding groups the accuracy of quantitative measurements of pulsatile flow.

The use of phase-encode grouping (PEG) allows acquisition of a complete cardiac cine in a single breath hold, eliminating respiratory artifacts and improving edge definition. One approach to quantitative magnetic resonance (MR) flow measurements in pulmonary, coronary, and renal arteries uses phase velocity mapping with a PEG, single breath-hold, cine technique. Phantom studies were designed to evaluate the accuracy of MR phase velocity mapping (MRV) with PEG in continuous and pulsatile flow measurements in small vessels. Experiments were performed on a 1.5-T MRI system and results were compared with those obtained by timed volume measurements and a transit-time ultrasound flowmeter. Flow velocity, pulsatile flow wave form, pulsing rate, and PEG size were varied. For continuous flow, MRV measured velocities correlated well with those calculated from timed volume measurements (r > 0.998) under mean spatial velocities ranging from 20-100 cm s-1. The temporal mean velocity difference between MRV and ultrasound flowmeter measurements was less than +/- 2.9 cms-1 under pulsatile flow conditions with PEG sizes of 5 or less, however, the mean velocity difference was > 7 cm s-1 for PEG sizes of 8 or more. Accurate MR velocity measurement with PEG in small vessels under conditions of pulsatile flow is possible if an appropriate PEG size is selected.

Artifacts

Factors determining aortic and umbilical blood flow pulsatility in fetal sheep.

The link between the flow pulsatility index (P.I.) and vascular resistance was examined by infusing vasoactive agents or by progressive embolization of the peripheral vascular bed. Experiments were performed on fetal sheep near term, 3 days after implantation of a flow probe, catheter-tip pressure transducers, and fluid-filled catheters to monitor hemodynamics in the umbilical artery and the descending thoracic aorta. Increasing placental and hind limb resistance by embolization with microspheres caused a progressive increase in flow P.I. whereas altering resistance with vasoactive agents had variable results. Results showed that flow P.I. was sensitive to impedance to pulsatile flow and pressure pulsatility in addition to vascular resistance. We conclude it is hazardous to use the flow P.I. to detect changes in vascular resistance particularly when these changes are induced by physiological adjustments or vasoactive agents.

Animals

Laser anemometry measurements of pulsatile flow past aortic valve prostheses.

Experimental results are presented on physiological pulsatile flow past caged ball and tilting disc aortic valve prostheses mounted in an axisymmetric chamber incorporated in a mock circulatory system. The measurements of velocity profiles and turbulent normal stresses during several times in a cardiac cycle were obtained using laser-Doppler anemometry. Our results show that with increased angle of opening for the tilting disc valves, a large but locally confined vortex is observed along the wall in the minor flow region throughout most of the cardiac cycle. The turbulent normal stresses measured downstream to the tilting disc in the minor flow region parallel to the tilt axis were found to be larger than those measured downstream to the caged ball valves. Comparison of measurements with steady flow at flow rates comparable to peak pulsatile flow rate show that the turbulent normal stresses are larger by a factor of two in pulsatile flow with a frequency of 1.2 Hz.

Aortic Valve

Pulsatile flow during cardiopulmonary bypass speeds thermal energy transfer: a possible explanation for the reduced afterdrop.

The instantaneous thermal energy balance and rates of thermal energy transfer during hypothermic cardiopulmonary bypass were measured for a group of patients receiving continuous flow and compared with a group receiving pulsatile flow. Cooling was more rapid and the rate of thermal energy delivery during rewarming significantly greater in the pulsatile flow group despite similar rewarming times. The final thermal energy balance at the end of cardiopulmonary bypass was larger and the period of postoperative hypothermia shorter in those receiving pulsatile flow. The greater rate of thermal energy transfer may explain the reduced afterdrop.

Body Temperature Regulation

Retrograde cerebral perfusion using pulsatile flow under conditions of profound hypothermia.

We investigated the effects of pulsatile flow for retrograde cerebral perfusion under profound hypothermia. Total cardiopulmonary bypass was carried out in adult mongrel dogs to induce hypothermia. One hour of total circulatory arrest was then performed at 20 degrees C in the control group of 6 dogs. In another group of 6 dogs, after cardiac arrest was obtained at 20 degrees C, retrograde cerebral perfusion with nonpulsatile flow was performed through both sides of the internal maxillary vein for 60 minutes; in a third group of 6 dogs, retrograde pulsatile perfusion was continued for 60 minutes. At the end of either retrograde perfusion or total circulatory arrest for 60 minutes, cerebrospinal fluid pressure and blood flow in the cerebral tissues were measured, and cerebral tissues were collected to measure water and adenosine triphosphate content. A significant difference was found for water content between the group undergoing retrograde perfusion with pulsatile flow as opposed to nonpulsatile flow. Cerebral tissues in the group perfused retrogradely with nonpulsatile flow contained more water than in the group perfused with pulsatile flow. Cerebrospinal fluid pressure was lower in the group perfused retrogradely with pulsatile flow when compared with nonpulsatile flow, but no significant difference could be found. As for cerebral flow and adenosine triphosphate content, no significant differences could be found between the groups perfused retrogradely with pulsatile or with non-pulsatile flow. Values were always higher, nonetheless, in the groups perfused with pulsatile flow. We conclude that retrograde cerebral perfusion with pulsatile flow, when used under conditions of profound hypothermia, possesses more cerebroprotective effects than does non-pulsatile perfusion or circulatory arrest.

Adenosine Triphosphate

Effect of pulsatile flow on microvascular resistance in adult rabbit lungs.

We have determined the effect of pulsatile flow on segmental vascular resistance in lungs from 29 adult rabbits. In group I (n = 4), II (n = 8), and III (n = 8) lungs were isolated. In group IV (n = 9) rabbits were anesthetized, their chests were opened, and lungs were studied in vivo. Group I and II lungs had steady-flow perfusion: group I with intact vasotonus and group II with papaverine treatment. Group III lungs (papaverine treated) were perfused for two consecutive 45-min periods with steady and pulsatile flow. In all isolated lungs and in lungs of five anesthetized rabbits, we measured pressures in subpleural 20- to 50-microns-diam arterioles and venules by use of the micropipette servo-nulling method. Measurement of distribution of blood flow in lungs of four anesthetized rabbits by use of radiolabeled microspheres revealed no abnormality of blood flow to the micropunctured lobe. We found that total and segmental vascular resistances were similar in group I and II lungs, with microvessels representing 55% of total resistance. In group III lungs, total resistance was 30% lower during pulsatile flow than during steady flow because of a lower microvascular resistance. Lungs in vivo (group IV) had a significantly lower total vascular resistance than isolated lungs and had a low fractional resistance in microvessels (approximately 28%). We conclude that, in isolated perfused adult rabbit lungs, vascular resistance is very high, particularly in the microvascular segment, and that pulsatile flow decreases microvascular resistance.

Animals

Does pulsatile flow improve glucose tolerance during extracorporeal circulation.

The present study was designed to determine the effect of pulsatile glow on glucose tolerance during cardiac surgery. Twenty patients were divided into two equal groups; ten patients receiving non-pulsatile bypass and the remaining patients receiving pulsatile flow. Patients receiving pulsatile flow had significantly lower systemic resistance in the intensive care unit. Glucose tolerance, however, was similar in both patient groups. Insulin secretion was impaired and serum glucose remained elevated throughout the period of extracorporeal circulation. We conclude from this study that glucose tolerance is unaffected by pulsatile flow.

Blood Glucose

Pulsatile flow visualization in the abdominal aorta under differing physiologic conditions: implications for increased susceptibility to atherosclerosis.

The infrarenal abdominal aorta is a common site for clinically significant atherosclerosis. As has been shown in other susceptible locations, vessel geometry, flow division rates, and pulsatility may result in hemodynamic conditions which influence the preferential localization of disease in the abdominal aorta segment. Pulsatile flow visualization was performed in a glass model of the aorta constructed from measurements of angiograms and cadaver aortas. Flow rates and pulsatile waveforms were varied to reflect typical physiological conditions. Under normal resting conditions, the flow patterns in the infrarenal aorta were more complex than those in the suprarenal location. Time varying vortex patterns appeared at the level of the renal arteries and propagated through the infrarenal aorta into the common iliac arteries. A region of oscillating velocity direction extended from the renal arteries to the aortic bifurcation along the posterior wall. Dye became trapped along the posterior wall, requiring several cardiac cycles for clearance. In contrast, there was rapid clearance of the dye in the anterior aorta. Under postprandial conditions, the flow patterns in the aorta were basically unchanged. Simulated exercise conditions created laminar hemodynamic features very different from the resting conditions, including a decrease in dye residence time. This study reveals significant time-dependent variations in the hemodynamics of the abdominal aorta under differing physiologic conditions. Hemodynamic factors such as low wall shear stress, oscillating shear direction, and high particle residence time may be related to the clinically seen preferential plaque localization in the infrarenal aorta.

Angiography

Short-term effects of levobunolol on ocular pulsatile flow.

In a randomized, double-masked, placebo-controlled study, we evaluated the effect of levobunolol 0.5%, a nonselective beta-blocker, on intraocular pressure, volume amplitude, and ocular pulsatile flow in healthy individuals and patients with glaucoma. Volume amplitude and ocular pulsatile flow were derived from measurements of pulse amplitude with a pneumatonometer. Two hours after instillation of levobunolol, intraocular pressure decreased from 26.0 +/- 5.1 mm Hg to 17.8 +/- 3.9 mm Hg (28.3%) (P less than .001) in glaucomatous eyes and 20.2 +/- 3.6 mm Hg to 14.5 +/- 4.2 mm Hg (29.6%) (P less than .001) in healthy eyes. Ocular pulsatile flow was increased after treatment with levobunolol from 482.1 +/- 133.3 microliter/minute to 548.5 +/- 180.3 microliter/minute (13.3%) (P less than .006) in glaucomatous eyes and 457.6 +/- 178.2 microliter/minute to 528 +/- 223.8 microliter/minute (12.3%) (P greater than .05) in healthy eyes. There was no significant change in intraocular pressure, volume amplitude, or ocular pulsatile flow in placebo-treated eyes. The implication of these data for glaucoma therapy is not clear. Although we used an instrument that supposedly measures total pulsatile flow, it may be that optic nerve blood flow is dependent on total, both pulsatile and nonpulsatile, flow. Further, even though retinal blood flow is a small component of total ocular blood flow, it may be equally or more important than choroidal flow because of the necessity to maintain the perfusion of the retinal ganglion cells.

Adult

Anesthetic and supportive management during experimental pulsatile flow perfusion studies in calves.

The purpose of this study was to determine the factors influencing successful experimental cardiopulmonary bypass studies using pulsatile flow perfusion and the medications and methodology necessary to produce successful bypass in calves. In six calves showing no cardiopulmonary pathology prior to bypass procedures, successful anesthesia and surgical intervention was accomplished. Animals were maintained on 5 hours of pulsatile flow bypass perfusion. Successful recovery from the procedures was accomplished. In two calves with pre-existing pulmonary pathology, anesthetic and surgical intervention was accomplished with the utilization of extensive anesthetic management and cardiac supportive medications until the animals could be initiated into 5 hours of pulsatile flow bypass perfusion, in spite of major pulmonary dysfunction. In these two animals, attempts to resuscitate upon termination of pulsatile flow perfusion were unsuccessful due to pre-existing excessive lesions in the lungs. This study shows a contrast between complete success of a pulsatile flow system in normal subjects versus the ultimate failure in experimental animals with pre-existing pulmonary pathology. The inability of experimental calves with a diseased lung to resume spontaneous cardiopulmonary function after the challenges of thoracic intervention indicates the unsuitability of animals with marked pre-existing pulmonary disease status for use in cardiopulmonary bypass studies.

Anesthesia, General

Visualization and finite element analysis of pulsatile flow in models of the abdominal aortic aneurysm.

Pulsatile flows in glass models simulating fusiform and lateral saccular aneurysms were investigated by a flow visualization method. When resting fluid starts to flow, the initial fluid motion is practically irrotational. After a short period of time, the flow began to separate from the proximal wall of the aneurysm. Then the separation bubble or vortex grew rapidly in size and filled the whole area of the aneurysm circumferentially. During this period of time, the center of the vortex moved from the proximal end to the distal point of the aneurysm. The transient reversal flow, for instance, which may occur at the end of the ejection period, passed between the wall of the aneurysm and the centrally located vortex. When the rate and pulsatile frequency of flow were high, the vortex broke down into highly disturbed flow (or turbulence) at the distal portion of the aneurysm. The same effect was observed when the length of the aneurysm was increased. A reduction in pulsatile amplitude made the flow pattern close to that in steady flow. A finite element analysis was made to obtain velocity and pressure fields in pulsatile flow through a tube with an axisymmetric expansion. Calculations were performed with the pulsatile flows used in the visualization experiment in order to study the effects of change in the pulsatile wave form by keeping the time-mean Reynolds number and Womersley's parameter unchanged. Calculated instantaneous patterns of velocity field and stream lines agreed well with the experimental results. The appearance and disappearance of the vortex in the dilated portion and its development resulted in complex distributions of pressure and shear fields. Locally minimum and maximum values of wall shear stress occurred at points just upstream and downstream of the distal end of the expansion when the flow rate reached its peak.

Aorta, Abdominal

Determination of principal reynolds stresses in pulsatile flows after elliptical filtering of discrete velocity measurements.

The purpose of this study was to develop a method to accurately determine mean velocities and Reynolds stresses in pulsatile flows. The pulsatile flow used to develop this method was produced within a transparent model of a left ventricular assist device (LVAD). Velocity measurements were taken at locations within the LVAD using a two-component laser Doppler anemometry (LDA) system. At each measurement location, as many as 4096 realizations of two coincident orthogonal velocity components were collected during preselected time windows over the pump cycle. The number of realizations was varied to determine how the number of data points collected affects the accuracy of the results. The duration of the time windows was varied to determine the maximum window size consistent with an assumption of pseudostationary flow. Erroneous velocity realizations were discarded from individual data sets by implementing successive elliptical filters on the velocity components. The mean velocities and principal Reynolds stresses were determined for each of the filtered data sets. The filtering technique, while eliminating less than 5 percent of the original data points, significantly reduced the computed Reynolds stresses. The results indicate that, with proper filtering, reasonable accuracy can be achieved using a velocity data set of 250 points, provided the time window is small enough to ensure pseudostationary flow (typically 20 to 40 ms). The results also reveal that the time window which is required to assume pseudostationary flow varies with location and cycle time and can range from 100 ms to less than 20 ms.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity

The calibration of gas volume measuring devices at continuous and pulsatile flows.

A gas circuit that was capable of passing continuous or pulsatile flows via a 350 L Collins chain-compensated gasometer was built and evaluated. Various turbine volume transducers and dry gas meters were tested with gas compositions and flows that mimicked: a) inspired pulsatile flow over the physiological range and, b) mixed expirate being withdrawn from a Douglas bag. We found the Collins gasometer to be very accurate throughout its elevation, but its mixing fan is not required and atmospheric air should be left to saturate and the added water vapour calculated. Dry gas meters can be accurate to within 1% when calibrated (60 to 150 L/min), but require at least 25 L to be passed through them. The Morgan Ventilometer is an extremely reproducible device (coefficient of variation 0-0.2%, n = 60), but an increase in calibration syringe rate will elevate the calibration factor and reduce the percentage accuracy (one unit increase in calibration factor reduces accuracy by 0.6 - 1.0%). The optimal calibration syringe rate appears to be 30 - 45 b/min. Entrainment through the attached respiratory tubing can also alter the validity of the Ventilometer's calibration procedure.

Equipment Design

Comparison of steady and pulsatile flow near the ventral and dorsal walls of casts of human aortic bifurcations.

Steady and pulsatile flows were passed through casts of human aortic bifurcations and, by means of a laser Doppler anemometer, fluid velocities were measured at selected sites near the ventral and dorsal walls. At these sites, in the vicinity of the bifurcation, the influence of secondary flow is significant and therefore an appreciation of the phasic variation of secondary flow patterns is important. Results are presented comparing the flow direction in both steady and pulsatile flow at sites in three casts. The common features of the flow at these sites were the persistence of the flow direction during the accelerating and decelerating phases of the pulsatile cycle, and the consistently smaller angle (measured from the inlet centerline) of the pulsatile flow direction as compared to the angle of the flow direction in steady flow.

Aorta