PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Pupil dynamics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

[A method for studying the dynamic mental work capacity of pupils from upper grades].

The presented methods include mechanical studies of the changes in the vision-movement reaction, the stability of the attention and mental activity; subjective evaluation of the tiredness, self-esteem, activity and temper as well as of some individual features. The methods have been approbated on students at XI, XII grade of SOU and present possibilities for evaluation of the correspondence between strain and physiologic and psychologic changes in the students during training.

Adolescent↗

Pupil diameter and light reaction during cardiac arrest and resuscitation.

OBJECTIVE: Traditionally, both pupil diameter and reaction to light have been examined to confirm the diagnosis of death. In the present study, we investigated quantitative changes in pupil diameter and light reaction for assessing the efficacy of cardiopulmonary resuscitation (CPR) and as a predictor of outcome. DESIGN: Controlled experimental study. SETTING: Animal research laboratory at a university-affiliated research institute. SUBJECTS: Fifteen domestic male pigs weighing between 33 and 40 kg. INTERVENTIONS: Ventricular fibrillation was induced with an alternating current delivered to the right ventricular endocardium. After 7 mins of untreated ventricular fibrillation, chest compression and mechanical ventilation were initiated and maintained for 6 mins. Restoration of spontaneous circulation then was attempted by electrical defibrillation. MEASUREMENTS AND MAIN RESULTS: Spontaneous circulation was reestablished in 9 of 15 animals. Pupils were fully dilated, and pupillary reaction to light was absent in 7 of the 9 resuscitated animals during untreated cardiac arrest. Progressive decreases in pupil diameter were observed together with restoration of light reaction during CPR, in each animal that was successfully resuscitated. When the pupils remained dilated and unreactive after 6 mins of CPR, resuscitation efforts were uniformly unsuccessful. A highly significant linear correlation between coronary perfusion pressure generated during precordial compression and pupil diameter was documented. Both were predictive of outcome. CONCLUSIONS: Dynamic changes of pupil diameter and reactions to light during cardiac arrest and resuscitation were correlated with coronary perfusion pressure, and both predicted the likelihood that spontaneous circulation and cerebral function would be restored.

Animals↗

A binocular pupil model for simulation of relative afferent pupil defects and the swinging flashlight test.

Many important intracranial neural pathways are involved in the control of the two muscles of the human pupil and the observation and analysis of pupil responses to light or other stimuli is of great interest in many clinical procedures. The binocular pupil model presented in this document has a topology encompassing much of the complexity of the pupil system neurophysiology. The dynamic parameters of the model were matched against pupil experiments under multiple conditions. It is employed here to simulate responses to the swinging flashlight test, a procedure which is routinely practiced in ophthalmology to diagnose different degrees of relative afferent pupil defects often a consequence of severe optic nerve diseases or retinal dysfunctions. Other, not light-dependent, pupil stimuli are briefly discussed.

Computer Simulation↗

Luminance detectors in the olivary pretectal nucleus and their relationship to the pupillary light reflex in the rat. II. Studies using sinusoidal light.

The luminance detectors in the olivary pretectal nucleus, which are likely candidates mediating the pupillary light reflex, responded to all frequencies of sinusoidally modulated light up to 12-25 Hz. At low frequencies (0.05-4.0 Hz) the luminance detectors responded with modulated firing to different stimulation rates. The modulation depth of the cell response increased with the increase in stimulation frequency up to 20 Hz, then rapidly fell. There was a delay between the peak intensity of the stimulus and the peak firing of cell response of about 30-40 ms. The amplitudes of the consensual pupil responses to the same sinusoidal stimulus, on the other hand, decreased with an increase in frequency and no discernible response was recorded above 2 Hz. The pupil responses were little affected by sympathectomy. The differences in the frequency response characteristics of luminance detectors and the pupil were attributed to the sluggish dynamic properties of the pupil muscles. This was demonstrated using an electronic model of the iris muscle which modified the responses of the luminance detectors giving output waveforms broadly resembling pupil responses to square and sinusoidally modulated lights.

Animals↗

Dynamic pupillary response controlled by the pupil size effect.

Pupillary escape has been described as an initial contraction followed by a slow redilatation, occurring in response to a step stimulus of low-intensity light. When the initial pupil size is small, the response to the same step stimulus is pupillary capture, a steady and sustained contraction. In this experiment a comparison was made between three modes of controlling pupil size and thereby of regulating the pupillary response: contralateral light background level, ipsilateral light background level, and accommodative level with which there is no change in retinal adaptation. All three level setting modes showed similar results in illustrating the pupil size effect. In addition, an inhibitory effect was found with both ipsilateral and contralateral light backgrounds that is independent of Weber's Law in the contralateral case. Our results lead to the formulation of a binocular model, featuring an internal parameter control whereby a signal dependent on the static pupil size regulates the gains of the parallel phasic and tonic pathways, the former responsive to transient changes of light, and the latter to background levels of light and accommodative levels. Our findings also raise interesting questions concerning the loci of these complex interactions in the simple neuroanatomy of the pupillary pathways.

Humans↗

Pupil adjustments in the eye of the common backswimmer

The pupil mechanism in the acone apposition eye of the semi-aquatic common backswimmer Notonecta glauca (Hemiptera) was investigated with infrared reflectometry of the pseudopupil. This method allows non-invasive continuous measurements of pupil responses in the living animal. The dynamic range of the pupil sensitivity is about 7 log units during daytime and 6 log units at night. During the day, the sensitivity range of the pupil covers the normal daylight intensities in the animal's habitat, just under the water surface (I50=10(19.2) photons m-2 sr-1 s-1). At night, the sensitivity is 1 log unit lower (I50=10(20.2) photons m-2 sr-1 s-1), ensuring that the pupil is maximally open when light intensities are low. During daytime, light adaptation is completed in slightly less than 40 min, and dark adaptation takes approximately 50 min. The pupil response is only slightly slower at night. The speed of the response as well as the pupil sensitivity are dependent on the preceding adaptation history. An endogenous circadian rhythm determines the control range of the pupil aperture. However, the rhythm is easily disturbed, especially within a 3 h period before dusk and dawn. The results are compared with corresponding results from other insects with the same type of pupil mechanism.

Journal Article↗

Effects of viewing distance on accommodative and pupillary responses following a three-dimensional task.

We have investigated accommodation and pupil responses after viewing stereoscopic images related to the resting position of accommodation. After a 10-min visual task viewing stereoscopic three-dimensional images, measurements of dynamic accommodation and pupil response were made using an infrared optometer and a pupil analyser. Four conditions were given for the viewing distance: 0.4 m (closer than the subjects' resting position), 1 m (approximating to their resting state), and 1.5 and 3 m (farther than the resting position). For the 0.4- and 1-m groups, a delay in the accommodation response for near-to-far movement was shown after the task, from 817 to 1120 ms and from 830 to 898 ms, respectively, but there was no change in the pupillary response. In the 1.5- and 3-m groups, on the other hand, a significant delay in the accommodation response for far-to-near movement was shown, from 827 to 912 ms and from 857 to 1150 ms, respectively, and greater miosis was found, from 7.2 to 9.2 mm2 and from 8.0 to 10.4 mm2. The data reveal that there are different after-effects on accommodation and pupillary functions when subjects perform the task within their accommodative resting position, than when the task is performed outside the resting position.

Accommodation, Ocular↗

Effects of oxazepam on performance and event-related brain potentials in vigilance tasks with static and dynamic stimuli.

Eighteen males performed two vigilance tasks with static and dynamic stimuli under the influence of oxazepam (20 and 40 mg) in a placebo-controlled, double blind, crossover design. Oxazepam (40 mg) caused impaired performance in the early part of a task with stimuli inducing frequent saccadic eye movements (dynamic task), relative to a task in which the stimuli remained at the same location (static task). This could not be explained by effects of the drug on oculomotor behavior. A larger diameter of the pupil in the dynamic task indicated that performance on this task may have required more effort. Stimulus processing requirements were higher in the dynamic task, as suggested by event-related brain potentials (ERPs), in particular the P3 wave; i.e., more resources had to be allocated in this task. This (additional) investment of resources appeared impossible after administration of oxazepam (40 mg). The conclusion was that tasks eliciting frequent eye movements require more effort and processing resources.

Adult↗

Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor.

A newly released commercial autorefractor, the Shin-Nippon SRW-5000 (Japan), has been found to be valid compared to subjective refraction and repeatable over a wide prescription range. Its binocular open field-of-view allows the accommodative state to be monitored while a natural environment is viewed. In conventional static mode, the device can take up to 45 readings in 1 min using digital image analysis of the reflected retinal image of a measurement ring. Continuous on-line analysis of the ring provides high (up to 60 Hz) temporal resolution of the refractive state to an accuracy of < 0.001 D. Pupil size can also be analysed to a resolution of < 0.001 mm. The measurement of accommodation and pupil size was relatively unaffected by eccentricity of viewing up to +/- 10 degrees and instrument focusing inaccuracies of +/- 5 mm. The resolution properties of the analysis are shown to be ideal for measurement of dynamic accommodation and pupil responses.

Accommodation, Ocular↗

A pilot evaluation of alfentanil-induced miosis as a noninvasive probe for hepatic cytochrome P450 3A4 (CYP3A4) activity in humans.

OBJECTIVE: The opioid alfentanil is a CYP3A4 substrate whose plasma clearance depends exclusively on hepatic CYP3A4 activity. Alfentanil clearance is an excellent in vivo probe for hepatic CYP3A4 activity and drug interactions in humans. However, such pharmacokinetic studies are invasive and time-consuming, and they require extensive analytical effort. This investigation tested the hypothesis that alfentanil-induced miosis (drug effect) can be used as a surrogate measure for alfentanil plasma concentrations and that alfentanil effect clearance will reflect plasma clearance; thus alfentanil can serve as a noninvasive probe for hepatic CYP3A4. METHODS: Six healthy volunteers were studied in a 3-way randomized crossover design. Each volunteer received 1 mg intravenous midazolam, followed 1 hour later by 15 microg/kg intravenous alfentanil, after CYP3A4 induction (rifampin [INN, rifampicin]), CYP3A4 inhibition (troleandomycin), and control. Dark-adapted pupil diameter and dynamic light response were measured coincident with venous blood sampling for up to 8 hours. Midazolam and alfentanil were quantified by gas chromatography-mass spectrometry. Plasma concentrations of alfentanil and midazolam (an additional CYP3A4 probe) and pupil diameter versus time data were analyzed by use of noncompartmental modeling. Pupil diameter change was analyzed analogously to determine the area under the alfentanil effect (miosis)-time curve (AUEC), effect clearance (CL(miosis)), and effect half-time. RESULTS: Compared with control, CYP3A4 induction and inhibition significantly altered the clearances of alfentanil (2.8 +/- 1.4, 5.3 +/- 1.0, and 0.42 +/- 0.1 ml/kg/min, respectively; P <.05 versus control) and midazolam. Dark-adapted resting diameter (in millimeters) was the best measure of alfentanil pupil effects. Alfentanil-dependent miosis was significantly altered by CYP3A4 modulation, and log(diameter(0) - diameter(t)) versus time curves resembled alfentanil plasma disposition. AUEC(infinity) values after control, CYP3A4 induction, and inhibition were 280 +/- 150, 120 +/- 22, and 1030 +/- 240 mm x min, respectively (P <.05 versus control). Effect clearances (CL(miosis)) were 4.2 +/- 1.3, 8.8 +/- 2.4, and 1.2 +/- 0.8 microg/mm x min, respectively, and effect half-times were 62 +/- 23, 34 +/- 27, and 211 +/- 35 minutes, respectively (P <.05 versus control). CL(miosis) was significantly correlated with plasma clearances of alfentanil (r = 0.77, P <.001) and midazolam (r = 0.80; P <.001). CONCLUSIONS: Alfentanil effect (miosis) may be a sensitive and reliable surrogate for plasma alfentanil concentrations. Alfentanil effect kinetics may be used as a noninvasive surrogate for conventional pharmacokinetics. CL(miosis) appears to be a suitable noninvasive in vivo probe for hepatic CYP3A4 activity, and it merits further investigation.

Adult↗

Comparison of dynamic digital pupillometry and static measurements of pupil size in determining scotopic pupil size before refractive surgery.

PURPOSE: To compare 2 digital infrared pupillometers. SETTING: Anterior Segment Service, Moorfields Eye Hospital, London, England. METHODS: Eighty-eight eyes of 44 healthy subjects were recruited into the study. The scotopic pupil size was measured with 2 instruments, a digital pupillometer (Procyon) and a Hartman-Shack wavefront aberrometer (Visx WaveScan). Agreement between the instruments was assessed. RESULTS: There were 21 men and 23 women with a mean age 38.1 years +/- 9.2 (SD) (range 23 to 62 years). The mean scotopic pupil diameter was significantly larger with the WaveScan (6.61 +/- 0.92 mm) than with the Procyon pupillometer (6.40 +/- 0.90 mm), P<.001. CONCLUSIONS: There was good agreement in measurement of scotopic pupil size between the two instruments. The larger pupil diameter found with the Visx WaveScan than with the Procyon digital pupillometer probably represents the different illumination level used by each instrument, the effects of accommodation, and target fogging.

Adult↗

Characteristics of pupil responses during far-to-near and near-to-far accommodation.

The static and dynamic aspects of the pupil response associated with various amplitudes of far-to-near (accommodation) and near-to-far (disaccommodation) focusing responses were evaluated in this study. Dynamic refractive and pupillary changes were measured simultaneously during focusing responses to targets at real distances in 12 young (23-26 years) emmetropic subjects. The targets were presented alternately at far (6 m) and at one of six near positions from 1 D (1 m) to 6 D (16.7 cm) in 1 D steps. The latency, magnitude and peak velocity of pupil changes associated with accommodation and disaccommodation responses were calculated. The latency of refractive changes was shorter than that of pupillary changes. In general, the pupil constricted with accommodation and started dilating while accommodation was still maintained, resulting in reduced pupil dilation with disaccommodation. The magnitude of the pupil response increased linearly with that of accommodation and disaccommodation. The amount of pupil change per dioptre of refractive change was invariant with various amplitudes of refractive change. The peak velocity of pupil constriction was greater than that of pupil dilation for corresponding amplitudes. The pupil response is more closely associated with accommodation than with disaccommodation.

Accommodation, Ocular↗

Simultaneous continuous recording of accommodation and pupil size using the modified Shin-Nippon SRW-5000 autorefractor.

The internal optics of the recent models of the Shin-Nippon SRW-5000 autorefractor (also marketed as the Grand Seiko WV-500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field-of-view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW-5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root-mean-square of model eye measures was least (0.017 +/- 0.002 D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on-line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001 D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to +/-10 degrees from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses.

Accommodation, Ocular↗

Infrared video pupillometry: a method used to measure the pupillary effects of drugs in small laboratory animals in real time.

Pupillometry in clinical investigation and in basic research often requires dynamic measurement of pupil size. Static methods, i.e. direct observation and still photography, are often used because of the high cost of commercial infrared pupillometers and problems with pupil-iris contrast in small animals. This report describes an improved infrared video pupillometer (IVP) which accurately measures the pupil area of small animals in real time (30 samples/sec). Two components of the pupillometer were designed and built by the authors: a "bright-pupil" infrared illumination system and a digital video signal processor (VSP). The use of a standard closed-circuit television camera to produce the pupil image signal results in a device that is relatively economical to construct. The IVP is sensitive enough to accurately track pupil are in the study of the pupil light reflex or pupillary oscillations. Several applications for the IVP are illustrated, including analysis of the transient response to light flashes and intravenous injections of drug, and analysis of the spontaneous and drug-induced pupillary fluctuation. Pupillography has been applied in the bioassay of various psychopharmacologic compounds and in the assessment of narcotic dependency. This IVP is being used in this laboratory to study the pupillary action of opiates in the rabbit and rat.

Animals↗